Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 2/2022

19.03.2021 | Original Research

Emulation of the BIS engine

verfasst von: Christopher W. Connor

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 2/2022

Einloggen, um Zugang zu erhalten

Abstract

The operation of the BIS monitor remains undescribed, despite 20 years of clinical use and 3000 academic articles. The core algorithmic software (the BIS Engine) can be retrieved from the motherboard of the A-2000 monitor in binary form through forensic disassembly using debugging interfaces left in place by the original designers, opening the possibility of executing the BIS algorithms on contemporary computers through emulation. Three steps were required for emulation. Firstly, the monitor input stage monitor was disassembled to determine how EEG signals can be compatibly presented to the Engine. Secondly, the Digital Signal Processor on which the Engine executes was recreated in software. Thirdly, the Engine code was patched, allowing execution separated from monitor hardware. Code performance under noise load was evaluated. EEG signals and BIS variables were obtained from a 13-year-old child in normal physiological sleep using a modern BIS monitor. BIS values in sleeping children exhibit a wide dynamic range, including values nominally associated with clinical anesthesia, providing a risk-free technique to obtain empirical EEG data that broadly exercise the algorithms. Emulation demonstrated a correlation coefficient of R = 0.943, consistent with correlations between official Engine iterations. Additive white noise in the EEG caused a progressive lifting and flattening of BIS values. Emulation replicates BIS Engine behavior, allowing calculation upon existing EEG datasets or signals from other, potentially remote or wireless, devices. Emulation provides advantages for elucidating the mathematical expression of the algorithms, which remain important as practical constraints on any hypothetical mechanism of action of anesthetics.
Literatur
1.
Zurück zum Zitat Connor CW. A forensic disassembly of the BIS monitor. Anesth Analg. 2020;131(6):1923–33.CrossRef Connor CW. A forensic disassembly of the BIS monitor. Anesth Analg. 2020;131(6):1923–33.CrossRef
2.
Zurück zum Zitat Rampil IJ. A Primer for EEG Signal Processing in Anesthesia. Anesthesiology. 1998;89(4):980–1002.CrossRef Rampil IJ. A Primer for EEG Signal Processing in Anesthesia. Anesthesiology. 1998;89(4):980–1002.CrossRef
3.
Zurück zum Zitat Inose H, Yasuda Y, Murakami J. (1962) A telemetering system by code modulation - ∆Σ modulation. IRE Trans Space Electroni Telemetry 3:204–209. Inose H, Yasuda Y, Murakami J. (1962) A telemetering system by code modulation - ∆Σ modulation. IRE Trans Space Electroni Telemetry 3:204–209.
4.
Zurück zum Zitat Pavan S, Schreier R, Temes GC. The magic of delta-sigma modulation. In: Understanding delta-sigma data converters. 2nd ed. Hoboken: IEEE Press; 2017. Pavan S, Schreier R, Temes GC. The magic of delta-sigma modulation. In: Understanding delta-sigma data converters. 2nd ed. Hoboken: IEEE Press; 2017.
5.
Zurück zum Zitat Horowitz P, Hill W. Sect. 13.9.2: Demystifying the delta-sigma converter. In: The art of electronics. 3rd ed. Cambridge: Cambridge University Press; 2015. Horowitz P, Hill W. Sect. 13.9.2: Demystifying the delta-sigma converter. In: The art of electronics. 3rd ed. Cambridge: Cambridge University Press; 2015.
6.
Zurück zum Zitat Candy J. A use of double integration in sigma delta modulation. IEEE Trans Commun. 1985;33(3):249–58.CrossRef Candy J. A use of double integration in sigma delta modulation. IEEE Trans Commun. 1985;33(3):249–58.CrossRef
7.
Zurück zum Zitat Pavan S, Schreier R, Temes GC. Second-order delta-sigma modulation. In: Understanding delta-sigma data converters. 2nd ed. Hoboken: IEEE Press; 2017. Pavan S, Schreier R, Temes GC. Second-order delta-sigma modulation. In: Understanding delta-sigma data converters. 2nd ed. Hoboken: IEEE Press; 2017.
8.
Zurück zum Zitat Stroustrup B. The C++ programming language. 4th ed. Upper Saddle River: Addison-Wesley; 2013. Stroustrup B. The C++ programming language. 4th ed. Upper Saddle River: Addison-Wesley; 2013.
10.
Zurück zum Zitat Cooley JW, Tukey JW. An algorithm for the machine calculation of complex Fourier series. Math Comput. 1965;19(90):297–301.CrossRef Cooley JW, Tukey JW. An algorithm for the machine calculation of complex Fourier series. Math Comput. 1965;19(90):297–301.CrossRef
11.
Zurück zum Zitat Texas, Instruments. TMS320C3x general-purpose applications, vol. SPRU194. Dallas: Texas Instruments Design Support Technical Documents; 1998. Texas, Instruments. TMS320C3x general-purpose applications, vol. SPRU194. Dallas: Texas Instruments Design Support Technical Documents; 1998.
12.
13.
Zurück zum Zitat Commodore-Amiga Inc. Amiga hardware reference manual. Amiga technical reference series. 3rd ed. Reading: Addison-Wesley; 1991. Commodore-Amiga Inc. Amiga hardware reference manual. Amiga technical reference series. 3rd ed. Reading: Addison-Wesley; 1991.
14.
Zurück zum Zitat Sleigh JW, Andrzejowski J, Steyn-Ross A, Steyn-Ross M. The bispectral index: a measure of depth of sleep? Anesth Analg. 1999;88(3):659–61.CrossRef Sleigh JW, Andrzejowski J, Steyn-Ross A, Steyn-Ross M. The bispectral index: a measure of depth of sleep? Anesth Analg. 1999;88(3):659–61.CrossRef
17.
Zurück zum Zitat Aspect Medical Systems. (2001) A-2000 Commercial Software Cover Letter. In: A-2000 Bispectral Index (BIS) Monitoring System Operating Manual. Aspect Medical Systems, Newton. Aspect Medical Systems. (2001) A-2000 Commercial Software Cover Letter. In: A-2000 Bispectral Index (BIS) Monitoring System Operating Manual. Aspect Medical Systems, Newton.
18.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRef Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRef
20.
Zurück zum Zitat Taheri BA, Knight RT, Smith RL. A dry electrode for EEG recording. Electroencephalogr Clin Neurophysiol. 1994;90(5):376–83.CrossRef Taheri BA, Knight RT, Smith RL. A dry electrode for EEG recording. Electroencephalogr Clin Neurophysiol. 1994;90(5):376–83.CrossRef
22.
Zurück zum Zitat Hudson AE, Pryor KO. Integration and information: anesthetic unconsciousness finds a new bandwidth. Anesthesiology. 2016;125(5):832–4.CrossRef Hudson AE, Pryor KO. Integration and information: anesthetic unconsciousness finds a new bandwidth. Anesthesiology. 2016;125(5):832–4.CrossRef
Metadaten
Titel
Emulation of the BIS engine
verfasst von
Christopher W. Connor
Publikationsdatum
19.03.2021
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 2/2022
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-021-00676-2

Weitere Artikel der Ausgabe 2/2022

Journal of Clinical Monitoring and Computing 2/2022 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Häufigste Gründe für Brustschmerzen bei Kindern

06.05.2024 Pädiatrische Diagnostik Nachrichten

Akute Brustschmerzen sind ein Alarmsymptom par exellence, schließlich sind manche Auslöser lebensbedrohlich. Auch Kinder klagen oft über Schmerzen in der Brust. Ein Studienteam ist den Ursachen nachgegangen.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.