Skip to main content
Erschienen in: Radiological Physics and Technology 1/2020

25.11.2019

Evaluating the effectiveness of a single CT method for attenuation correction in stress-rest myocardial perfusion imaging with thallium-201 chloride SPECT

verfasst von: Mitsuha Fukami, Kiyoshi Tamura, Yuya Nakamura, Syoichi Nakatsukasa, Masayuki Sasaki

Erschienen in: Radiological Physics and Technology | Ausgabe 1/2020

Einloggen, um Zugang zu erhalten

Abstract

This study aimed to evaluate the effectiveness of a single computed tomography (CT) based attenuation correction method using thallium-201 chloride (201TlCl) in stress-rest myocardial perfusion imaging (MPI). The data of 106 patients who underwent MPI with single photon emission computed tomography (SPECT) using 201TlCl were retrospectively reviewed. MPI SPECT images were reconstructed using stress SPECT and stress CT (SIO), rest SPECT and rest CT (RIO), and rest SPECT and stress CT (RIA). The accuracy of alignment between the SPECT and CT images was evaluated with normalized cross-correlation (NCC) and visual examination. The summed rest score (SRS) was used to evaluate hypoperfusion at rest; washout rate (WO) was used to assess ischemia; and left ventricular ejection fraction (LVEF) was used to evaluate the left ventricle (LV) function. There was no significant difference in NCC and visual evaluation in all three dimensions. The SRS of both RIO and RIA (7.5 ± 7.7 and 7.7 ± 7.6, respectively) did not differ significantly. However, SRSs of RIO and RIA showed a strong correlation (r = 0.98). The WO was 39.0 ± 0.98% for both RIO and RIA, with a strong correlation between the two values (r = 1.00). LVEF was 61.1 ± 17.4% for RIO and 61.3 ± 17.4% for RIA, and a strong correlation was observed between the two values (r = 1.00). In conclusion, the single CT-based attenuation correction method with 201TlCl SPECT has an accuracy equivalent to that of the conventional two CT-based attenuation correction method.
Literatur
1.
Zurück zum Zitat Ami E. Iskandrian, Ernest V. Garcia. Nuclear cardiac imaging: principles and applications. Oxford University Press; 2008, p. 149. Ami E. Iskandrian, Ernest V. Garcia. Nuclear cardiac imaging: principles and applications. Oxford University Press; 2008, p. 149.
2.
Zurück zum Zitat Nobutoku M. Data Correction and 1lmage Reconstruction Methods on SPECT. MEDICAL IMAGING TECHNOLOGY. 2001 November; vol. 19: No. 6. Nobutoku M. Data Correction and 1lmage Reconstruction Methods on SPECT. MEDICAL IMAGING TECHNOLOGY. 2001 November; vol. 19: No. 6.
3.
Zurück zum Zitat Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, Chisin R. Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images. Eur J Nucl Med. 2000;27:619–27.CrossRef Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, Chisin R. Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images. Eur J Nucl Med. 2000;27:619–27.CrossRef
4.
Zurück zum Zitat Steven Burrell, MD, Anita MacDonald, BHSc. Artifacts and pitfalls in myocardial perfusion imaging. J Nucl Med Technol. 2006;34:193–211 Steven Burrell, MD, Anita MacDonald, BHSc. Artifacts and pitfalls in myocardial perfusion imaging. J Nucl Med Technol. 2006;34:193–211
5.
Zurück zum Zitat DePuey EG 3rd. How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med. 1994;35:699–702.PubMed DePuey EG 3rd. How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med. 1994;35:699–702.PubMed
6.
Zurück zum Zitat Huang JY1, Huang CK, Yen RF, Wu HY, Tu YK, Cheng MF, Lu CC, Tzen KY, Chien KL, Wu YW. Diagnostic performance of attenuation-corrected myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis. J Nucl Med. 2016; 57:1893–8.CrossRef Huang JY1, Huang CK, Yen RF, Wu HY, Tu YK, Cheng MF, Lu CC, Tzen KY, Chien KL, Wu YW. Diagnostic performance of attenuation-corrected myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis. J Nucl Med. 2016; 57:1893–8.CrossRef
7.
Zurück zum Zitat Sasaki M, Kawase S, Miyazaki Y, Fujimoto T, Higashimura K. The examination of attenuation correction using one computed tomography scan in myocardial perfusion stress-rest single photon emission computed tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68:997–1005.CrossRef Sasaki M, Kawase S, Miyazaki Y, Fujimoto T, Higashimura K. The examination of attenuation correction using one computed tomography scan in myocardial perfusion stress-rest single photon emission computed tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2012;68:997–1005.CrossRef
8.
Zurück zum Zitat Wells RG, Trottier M, Premaratne M, Vanderwerf K, Ruddy TD. Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging. J Nucl Cardiol. 2018;25:616–24.CrossRef Wells RG, Trottier M, Premaratne M, Vanderwerf K, Ruddy TD. Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging. J Nucl Cardiol. 2018;25:616–24.CrossRef
9.
Zurück zum Zitat Goetze S, Brown TL, Lavely WC, Zhang Z, Bengel FM. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration. J Nucl Med. 2007;48:1090–5.CrossRef Goetze S, Brown TL, Lavely WC, Zhang Z, Bengel FM. Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration. J Nucl Med. 2007;48:1090–5.CrossRef
10.
Zurück zum Zitat Nakajima K, Matsumoto N, Kasai T, Matsuo S, Kiso K. Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database. Ann Nucl Med. 2016;30(3):188–99.CrossRef Nakajima K, Matsumoto N, Kasai T, Matsuo S, Kiso K. Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database. Ann Nucl Med. 2016;30(3):188–99.CrossRef
11.
Zurück zum Zitat Abidov A1, Bax JJ, Hayes SW, Cohen I, Nishina H. Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD. J Nucl Med. 2004;45:1999–2007. Abidov A1, Bax JJ, Hayes SW, Cohen I, Nishina H. Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD. J Nucl Med. 2004;45:1999–2007.
12.
Zurück zum Zitat Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation. 2003;107(23):2900–7.CrossRef Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation. 2003;107(23):2900–7.CrossRef
13.
Zurück zum Zitat Fathala A. Myocardial Perfusion Scintigraphy: Techniques, Interpretation, Indications and Reporting. Ann Saudi Med. 2011;31:625–34.CrossRef Fathala A. Myocardial Perfusion Scintigraphy: Techniques, Interpretation, Indications and Reporting. Ann Saudi Med. 2011;31:625–34.CrossRef
14.
Zurück zum Zitat Taillefer R1, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. Am Coll Cardiol. 1997;29:69–77.CrossRef Taillefer R1, DePuey EG, Udelson JE, Beller GA, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. Am Coll Cardiol. 1997;29:69–77.CrossRef
15.
Zurück zum Zitat Kim JY, Park HC, Kim SJ, Chang HS, Choi HJ, Kim YH. Assessment of left ventricular ejection fraction by thallium-201 myocardial SPECT-CT in patients with angina pectoris: comparison with 2d echocardiography. Nucl Med Mol Imaging. 2019;53:136–43.CrossRef Kim JY, Park HC, Kim SJ, Chang HS, Choi HJ, Kim YH. Assessment of left ventricular ejection fraction by thallium-201 myocardial SPECT-CT in patients with angina pectoris: comparison with 2d echocardiography. Nucl Med Mol Imaging. 2019;53:136–43.CrossRef
16.
Zurück zum Zitat Slart RH, Tio RA, Zeebregts CJ, Willemsen AT, Dierckx RA. Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes. Ann Nucl Med. 2008;22(3):171–6.CrossRef Slart RH, Tio RA, Zeebregts CJ, Willemsen AT, Dierckx RA. Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes. Ann Nucl Med. 2008;22(3):171–6.CrossRef
17.
Zurück zum Zitat Schepis T, Gaemperli O, Koepfli P, Valenta I, Strobel K. Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med. 2006;47(8):1288–94.PubMed Schepis T, Gaemperli O, Koepfli P, Valenta I, Strobel K. Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med. 2006;47(8):1288–94.PubMed
18.
Zurück zum Zitat Tahmasebi AM, Davis MH, Wild CJ, Rodd JM, Hakyemez H, Abolmaesumi P, Johnsrude IS. Is the link between anatomical structure and function equally strong at all cognitive levels of processing? Cereb Cortex. 2012;22:1593–603.CrossRef Tahmasebi AM, Davis MH, Wild CJ, Rodd JM, Hakyemez H, Abolmaesumi P, Johnsrude IS. Is the link between anatomical structure and function equally strong at all cognitive levels of processing? Cereb Cortex. 2012;22:1593–603.CrossRef
19.
Zurück zum Zitat Arabi H, Zaidi H. Comparison of atlas-based techniques for whole-body bone segmentation. Semin Nucl Med. Med Image Anal. 2017;36:98–112.CrossRef Arabi H, Zaidi H. Comparison of atlas-based techniques for whole-body bone segmentation. Semin Nucl Med. Med Image Anal. 2017;36:98–112.CrossRef
20.
Zurück zum Zitat Sarkar S1, Johnson TD, Ma B, Chenevert TL, Bland PH. Evaluation of an automatic registration-based algorithm for direct measurement of volume change in tumors. Int J Radiat Oncol Biol Phys. 2012;83(3):1038–46.CrossRef Sarkar S1, Johnson TD, Ma B, Chenevert TL, Bland PH. Evaluation of an automatic registration-based algorithm for direct measurement of volume change in tumors. Int J Radiat Oncol Biol Phys. 2012;83(3):1038–46.CrossRef
21.
Zurück zum Zitat Ahlman MA, Nietert PJ, Wahlquist AE, Serguson JM, Berry MW, Suranyi P, Liu S, Spicer KM. A single CT for attenuation correction of both rest and stress SPECT myocardial perfusion imaging: a retrospective feasibility study. Int J Clin Exp Med. 2014;7(1):148–55.PubMedPubMedCentral Ahlman MA, Nietert PJ, Wahlquist AE, Serguson JM, Berry MW, Suranyi P, Liu S, Spicer KM. A single CT for attenuation correction of both rest and stress SPECT myocardial perfusion imaging: a retrospective feasibility study. Int J Clin Exp Med. 2014;7(1):148–55.PubMedPubMedCentral
22.
Zurück zum Zitat Bateman TM, Cullom SJ. Attenuation correction single-photon emission computed tomography myocardial perfusion imaging. Semin Nucl Med. 2005;35:37–51.CrossRef Bateman TM, Cullom SJ. Attenuation correction single-photon emission computed tomography myocardial perfusion imaging. Semin Nucl Med. 2005;35:37–51.CrossRef
Metadaten
Titel
Evaluating the effectiveness of a single CT method for attenuation correction in stress-rest myocardial perfusion imaging with thallium-201 chloride SPECT
verfasst von
Mitsuha Fukami
Kiyoshi Tamura
Yuya Nakamura
Syoichi Nakatsukasa
Masayuki Sasaki
Publikationsdatum
25.11.2019
Verlag
Springer Singapore
Erschienen in
Radiological Physics and Technology / Ausgabe 1/2020
Print ISSN: 1865-0333
Elektronische ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00540-8

Weitere Artikel der Ausgabe 1/2020

Radiological Physics and Technology 1/2020 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.