Skip to main content
Erschienen in: European Radiology 1/2008

01.01.2008 | Breast

False-negative results after stereotactically guided vacuum biopsy

verfasst von: D. Peter, J. Grünhagen, R. Wenke, F. K. W. Schäfer, I. Schreer

Erschienen in: European Radiology | Ausgabe 1/2008

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to determine the false negative rate of stereotactically guided vacuum biopsy (VB). Data of patients with benign lesions in VB were evaluated retrospectively during a median follow-up period of 21 months. A total of 404 VB were considered benign and representative and were recommended for follow-up. Of these 404 lesions, 195 were completely removed radiologically. Follow-up data were available for 354/404 patients (87.6%), with intervals ranging from 3 to 66 months (median 21, mean 22.4). Reintervention or surgery was necessary in 13/354 (3.7%) cases. Of these cases, 5/354 (1.4%) turned out to be false negatives. Four of these cases showed large areas of microcalcifications or several clusters, and only partial removal was possible due to the size of the lesions.Although VB is an accurate procedure for diagnosing nonpalpable breast lesions with a low cancer miss rate, we consider the exclusion of malignancy in cases of disseminated microcalcifications or several clusters as a limitation. The radiologic-pathologic correlation in these cases is a challenge, particularly in terms of the residuals. Strict follow-up of benign lesions is essential to avoid delayed cancer diagnosis.
Literatur
1.
Zurück zum Zitat Heywang-Koebrunner SH, Schaumloffel U, Vieweg P, Buchmann J, Lampe D (1998) Minimal invasive stereotaxic vacuum core breast biopsy. Eur Radiol 8(3):377–385CrossRef Heywang-Koebrunner SH, Schaumloffel U, Vieweg P, Buchmann J, Lampe D (1998) Minimal invasive stereotaxic vacuum core breast biopsy. Eur Radiol 8(3):377–385CrossRef
2.
Zurück zum Zitat Libermann L, Gougoutas CA, Zakowski MF, La Trenta LR, Abramson AF, Morris EA, Dershaw DD (2001) Calcifications highly suggestive of malignancy: comparison of breast biopsy methods. AJR 177:165–172 Libermann L, Gougoutas CA, Zakowski MF, La Trenta LR, Abramson AF, Morris EA, Dershaw DD (2001) Calcifications highly suggestive of malignancy: comparison of breast biopsy methods. AJR 177:165–172
3.
Zurück zum Zitat Parker SH, Lovin JD, Jobe WE, Burke BJ, Hopper KD, Yakes WF (1991) Nonpalpable breast lesions: stereotactic automated large-core biopsies. Radiology 180:403–407PubMed Parker SH, Lovin JD, Jobe WE, Burke BJ, Hopper KD, Yakes WF (1991) Nonpalpable breast lesions: stereotactic automated large-core biopsies. Radiology 180:403–407PubMed
4.
Zurück zum Zitat Berg WA, Krebs TL, Campassi C et al (1998) Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model. Radiology 205:203–208 Berg WA, Krebs TL, Campassi C et al (1998) Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model. Radiology 205:203–208
5.
Zurück zum Zitat Lamm RL, Jackman RJ (2000) Mammographic abnormalities caused by percutaneus sterotactic biopsy of histologically benign lesions evident on follow-up mammogramms. AJR 174:753–756PubMed Lamm RL, Jackman RJ (2000) Mammographic abnormalities caused by percutaneus sterotactic biopsy of histologically benign lesions evident on follow-up mammogramms. AJR 174:753–756PubMed
6.
Zurück zum Zitat Jackman RJ, Marzoni FA Jr (1997) Needle-localised breast biopsy: why do we fail? Radiology 204(3):677–684PubMed Jackman RJ, Marzoni FA Jr (1997) Needle-localised breast biopsy: why do we fail? Radiology 204(3):677–684PubMed
7.
Zurück zum Zitat Rotter K, Haentschel G, Koethe D, Goetz L, Bornhofen-Pöschke A, Lebrecht A, Kölbl H, Heywang-Koebrunner S (2003) Evaluation of mammagraphic and clinical follow-up after 755 stereotactic vacuum-assisted breast biopsies. Am J Surg 186:134–142PubMedCrossRef Rotter K, Haentschel G, Koethe D, Goetz L, Bornhofen-Pöschke A, Lebrecht A, Kölbl H, Heywang-Koebrunner S (2003) Evaluation of mammagraphic and clinical follow-up after 755 stereotactic vacuum-assisted breast biopsies. Am J Surg 186:134–142PubMedCrossRef
8.
Zurück zum Zitat Lai JT, Burrowes P, MacGregor JH (2001) Diagnostic accuracy of a stereotaxically guided vacuum-assisted large core breast biopsy program in Canada. Can Assoc Radiol J 52(4):223–227PubMed Lai JT, Burrowes P, MacGregor JH (2001) Diagnostic accuracy of a stereotaxically guided vacuum-assisted large core breast biopsy program in Canada. Can Assoc Radiol J 52(4):223–227PubMed
9.
Zurück zum Zitat Shah VI, Raju U, Chitale D, Deshpande V, Gregory N, Strand V (2003) False-negative core needle biopsies of the breast. Cancer 97:1824–1831PubMedCrossRef Shah VI, Raju U, Chitale D, Deshpande V, Gregory N, Strand V (2003) False-negative core needle biopsies of the breast. Cancer 97:1824–1831PubMedCrossRef
10.
Zurück zum Zitat Apesteguia L, Mellado M, Saenz J, Cordero JL, Reparaz B, De Miguel C (2002) Vacuum-assisted breast biopsy on digital stereotaxic table of nonpal-pable lesions non-recognisable by ultrasonography. Eur Radiol 12:638–645PubMed Apesteguia L, Mellado M, Saenz J, Cordero JL, Reparaz B, De Miguel C (2002) Vacuum-assisted breast biopsy on digital stereotaxic table of nonpal-pable lesions non-recognisable by ultrasonography. Eur Radiol 12:638–645PubMed
11.
Zurück zum Zitat Heywang-Köbrunner SH, Schreer I, Decker T, Böcker W (2003) Interdisciplinary consensus on the use and technique of vaccum-assisted stereotactic breast biopsy. Eur J Radiol 47:232–236PubMedCrossRef Heywang-Köbrunner SH, Schreer I, Decker T, Böcker W (2003) Interdisciplinary consensus on the use and technique of vaccum-assisted stereotactic breast biopsy. Eur J Radiol 47:232–236PubMedCrossRef
12.
Zurück zum Zitat Goodman KA, Birdwell RL, Ikeda DM (1998) Compliance with recommended follow-up after percutaneus breast core biops. AJR 170:89–92PubMed Goodman KA, Birdwell RL, Ikeda DM (1998) Compliance with recommended follow-up after percutaneus breast core biops. AJR 170:89–92PubMed
13.
Zurück zum Zitat Pal S, Ikeda DM, Birdwell RL (1996) Compliancce with recommended follow-up after fine-needle aspiration biopsy of non-palpable breast lesions: a retrospective study. Radiology 201:71–74PubMed Pal S, Ikeda DM, Birdwell RL (1996) Compliancce with recommended follow-up after fine-needle aspiration biopsy of non-palpable breast lesions: a retrospective study. Radiology 201:71–74PubMed
14.
Zurück zum Zitat American College of Radiology (1998) Illustrated breast imaging reporting and data system (BI-RADS), 3rd edn. American College of Radiology, Reston, VA American College of Radiology (1998) Illustrated breast imaging reporting and data system (BI-RADS), 3rd edn. American College of Radiology, Reston, VA
15.
Zurück zum Zitat Liberman L, Smolkin JH, Dershaw DD, Morris EA, Abramson AF, Rosen PP (1998) Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy. Radiology 208:251–260PubMed Liberman L, Smolkin JH, Dershaw DD, Morris EA, Abramson AF, Rosen PP (1998) Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy. Radiology 208:251–260PubMed
16.
Zurück zum Zitat Parker SH, Klaus AJ (1997) Performing a breast biopsy with a directional, vacuum-assisted biopsy instrument. Radiographics 17:1233–1252PubMed Parker SH, Klaus AJ (1997) Performing a breast biopsy with a directional, vacuum-assisted biopsy instrument. Radiographics 17:1233–1252PubMed
17.
Zurück zum Zitat Sie A, Bryan DC, Gaines V, Killebrew LK, Kim CH, Morrison CC, Poller WR, Romilly AP, Schilling K, Sung JH (2006) Multicenter evaluation of the breast lesion excision system, a percutaneous, vacuum-assisted, intact-specimen breast biopsy device. Cancer 107:945–949PubMedCrossRef Sie A, Bryan DC, Gaines V, Killebrew LK, Kim CH, Morrison CC, Poller WR, Romilly AP, Schilling K, Sung JH (2006) Multicenter evaluation of the breast lesion excision system, a percutaneous, vacuum-assisted, intact-specimen breast biopsy device. Cancer 107:945–949PubMedCrossRef
18.
Zurück zum Zitat Van den Bosch MA, Daniel BL, Pal S, Nowels KW, Birdwell RL, Jeffrey SS, Ikeda DM (2006) MRI-guided needle localization of suspicious breast lesions: results of a freehand technique. Eur Radiol 16:1811–1817PubMedCrossRef Van den Bosch MA, Daniel BL, Pal S, Nowels KW, Birdwell RL, Jeffrey SS, Ikeda DM (2006) MRI-guided needle localization of suspicious breast lesions: results of a freehand technique. Eur Radiol 16:1811–1817PubMedCrossRef
19.
Zurück zum Zitat Pfarl G, Helbich T, Riedl CC, Wagner T, Gnant M, Rundas M, Liberman L (1999) Stereotactic 11-gauge vacuum-assisted breast biopsy: a validation study. AJR 179:1503–1507 Pfarl G, Helbich T, Riedl CC, Wagner T, Gnant M, Rundas M, Liberman L (1999) Stereotactic 11-gauge vacuum-assisted breast biopsy: a validation study. AJR 179:1503–1507
20.
Zurück zum Zitat Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni FA, Finkelstein SI, Shepard MJ (1999) Sterotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 210:799–805PubMed Jackman RJ, Nowels KW, Rodriguez-Soto J, Marzoni FA, Finkelstein SI, Shepard MJ (1999) Sterotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up. Radiology 210:799–805PubMed
21.
Zurück zum Zitat Kettritz U, Rotter K, Schreer I, Murauer M, Schulz-Wendtland R, Peter D, Heywang-Köbrunner S (2004) Stereotactic vacuum-assisted breast biopsy in 2874 patients. A multicenter study. Cancer 100:245–251PubMedCrossRef Kettritz U, Rotter K, Schreer I, Murauer M, Schulz-Wendtland R, Peter D, Heywang-Köbrunner S (2004) Stereotactic vacuum-assisted breast biopsy in 2874 patients. A multicenter study. Cancer 100:245–251PubMedCrossRef
Metadaten
Titel
False-negative results after stereotactically guided vacuum biopsy
verfasst von
D. Peter
J. Grünhagen
R. Wenke
F. K. W. Schäfer
I. Schreer
Publikationsdatum
01.01.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 1/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-007-0707-x

Weitere Artikel der Ausgabe 1/2008

European Radiology 1/2008 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.