Erschienen in:
01.01.2008 | Musculoskeletal
Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma
verfasst von:
Patric Kröpil, Roland Fenk, Lars B. Fritz, Dirk Blondin, Guido Kobbe, Ulrich Mödder, Mathias Cohnen
Erschienen in:
European Radiology
|
Ausgabe 1/2008
Einloggen, um Zugang zu erhalten
Abstract
This study compares the sensitivity of whole-body multidetector CT (MDCT) and conventional radiography (CR) in the staging of multiple myeloma (MM). Twenty-nine patients with MM underwent a staging examination both by MDCT and CR. CT examination was performed with a collimation of 64×0.6 mm, a tube potential of 100 kVp, an effective tube current-time product of 100 mAs and automatic dose modulation as low-dose protocol. Number, size and diagnostic confidence of osteolytic lesions were determined and compared. The effective dose of MDCT and CR was assessed. Using MDCT, the detection of osteolysis was increased seven-fold concerning the spine. Ninety-seven lesions in 18 patients were detected exclusively by MDCT. The detection rate concerning the spine, pelvic skeleton and thoracic cage was significantly higher (p≤0.001), and diagnostic confidence was increased by MDCT (p<0.02) compared to CR. Therapy was changed after MDCT in 18.2% of the patients with a clinical suspicion of progressive disease. The estimated effective dose of MDCT (4.8 mSv) and CR (1.7 mSv) was comparable. In conclusion, MDCT has a significantly higher sensitivity and reliability in the detection of osteolysis than CR and can be recommended as standard imaging method in the staging of MM.