Feasibility analysis of a novel non-invasive ultrasonographic method for the measurement of intra-abdominal pressure in the intensive care unit

verfasst von: Kay Choong See, Salar Tayebi, Chew Lai Sum, Jason Phua, Johan Stiens, Robert Wise, Amartya Mukhopadhyay, Manu L.N.G. Malbrain

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 5/2023

Einloggen, um Zugang zu erhalten

Abstract

Increased intra-abdominal pressure (IAP) is an important vital sign in critically ill patients and has a negative impact on morbidity and mortality. This study aimed to validate a novel non-invasive ultrasonographic approach to IAP measurement against the gold standard intra-bladder pressure (IBP) method. We conducted a prospective observational study in an adult medical ICU of a university hospital. IAP measurements using ultrasonography by two independent operators, with different experience levels (experienced, IAPUS1; inexperienced, IAPUS2), were compared with the gold standard IBP method performed by a third blinded operator. For the ultrasonographic method, decremental external pressure was applied on the anterior abdominal wall using a bottle filled with decreasing volumes of water. Ultrasonography looked at peritoneal rebound upon brisk withdrawal of the external pressure. The loss of peritoneal rebound was identified as the point where IAP was equal to or above the applied external pressure. Twenty-one patients underwent 74 IAP readings (range 2–15 mmHg). The number of readings per patient was 3.5 ± 2.5, and the abdominal wall thickness was 24.6 ± 13.1 mm. Bland and Altman’s analysis showed a bias (0.39 and 0.61 mmHg) and precision (1.38 and 1.51 mmHg) for the comparison of IAPUS1 and IAPUS2 and vs. IBP, respectively with small limits of agreement that were in line with the research guidelines of the Abdominal Compartment Society (WSACS). Our novel ultrasound-based IAP method displayed good correlation and agreement between IAP and IBP at levels up to 15 mmHg and is an excellent solution for quick decision-making in critically ill patients.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Carter BM, Howard C. A 6th vital sign–potential use of nasogastric tube for intra-abdominal pressure monitoring method to detect feeding intolerance in very low birth-weight Preterm Infants (< 1500 g). Adv Neonatal Care. 2015;15(3):176–81.CrossRefPubMed Carter BM, Howard C. A 6th vital sign–potential use of nasogastric tube for intra-abdominal pressure monitoring method to detect feeding intolerance in very low birth-weight Preterm Infants (< 1500 g). Adv Neonatal Care. 2015;15(3):176–81.CrossRefPubMed
2.
Zurück zum Zitat Kirkpatrick AW, et al. WSACS–The Abdominal Compartment Society. A Society dedicated to the study of the physiology and pathophysiology of the abdominal compartment and its interactions with all organ systems. Anaesthesiol Intensive Ther. 2015;47(3):191–4.CrossRefPubMed Kirkpatrick AW, et al. WSACS–The Abdominal Compartment Society. A Society dedicated to the study of the physiology and pathophysiology of the abdominal compartment and its interactions with all organ systems. Anaesthesiol Intensive Ther. 2015;47(3):191–4.CrossRefPubMed
3.
Zurück zum Zitat Kirkpatrick AW, et al. Update from the Abdominal Compartment Society (WSACS) on intra-abdominal hypertension and abdominal compartment syndrome: past, present, and future beyond Banff 2017. Anaesthesiol Intensive Ther. 2017;49(2):83–7.CrossRefPubMed Kirkpatrick AW, et al. Update from the Abdominal Compartment Society (WSACS) on intra-abdominal hypertension and abdominal compartment syndrome: past, present, and future beyond Banff 2017. Anaesthesiol Intensive Ther. 2017;49(2):83–7.CrossRefPubMed
4.
Zurück zum Zitat Sugrue M, et al. Clinical examination is an inaccurate predictor of intraabdominal pressure. World J Surg. 2002;26(12):1428–31.CrossRefPubMed Sugrue M, et al. Clinical examination is an inaccurate predictor of intraabdominal pressure. World J Surg. 2002;26(12):1428–31.CrossRefPubMed
5.
Zurück zum Zitat Jacobs R et al. Fluid Management, Intra-Abdominal Hypertension and the Abdominal Compartment Syndrome: A Narrative Review. Life (Basel), 2022. 12(9). Jacobs R et al. Fluid Management, Intra-Abdominal Hypertension and the Abdominal Compartment Syndrome: A Narrative Review. Life (Basel), 2022. 12(9).
6.
Zurück zum Zitat Minini A, Emara MM, Malbrain MLNG et al. Polycompartment Syndrome, in Compartment Syndrome, F. Coccolini, Editors. 2021, Springer International Publishing: Cham. p. 101–121. Minini A, Emara MM, Malbrain MLNG et al. Polycompartment Syndrome, in Compartment Syndrome, F. Coccolini, Editors. 2021, Springer International Publishing: Cham. p. 101–121.
7.
Zurück zum Zitat De Laet I, Hoste E, De Waele JJ. Transvesical intra-abdominal pressure measurement using minimal instillation volumes: how low can we go? Intensive Care Med. 2008;34(4):746–50.CrossRefPubMed De Laet I, Hoste E, De Waele JJ. Transvesical intra-abdominal pressure measurement using minimal instillation volumes: how low can we go? Intensive Care Med. 2008;34(4):746–50.CrossRefPubMed
8.
Zurück zum Zitat De Waele JJ, et al. The effect of different reference transducer positions on intra-abdominal pressure measurement: a multicenter analysis. Intensive Care Med. 2008;34(7):1299–303.CrossRefPubMed De Waele JJ, et al. The effect of different reference transducer positions on intra-abdominal pressure measurement: a multicenter analysis. Intensive Care Med. 2008;34(7):1299–303.CrossRefPubMed
9.
Zurück zum Zitat Al-Hwiesh A, et al. Intraperitoneal pressure and intra-abdominal pressure: are they the same? Perit Dial Int. 2011;31(3):315–9.CrossRefPubMed Al-Hwiesh A, et al. Intraperitoneal pressure and intra-abdominal pressure: are they the same? Perit Dial Int. 2011;31(3):315–9.CrossRefPubMed
10.
Zurück zum Zitat Khanna AK, Rola P, Malbrain M. Biomarkers for intra-abdominal pressure: another tool in the toolbox? Eur Heart J Acute Cardiovasc Care. 2022;11(6):461–3.CrossRefPubMed Khanna AK, Rola P, Malbrain M. Biomarkers for intra-abdominal pressure: another tool in the toolbox? Eur Heart J Acute Cardiovasc Care. 2022;11(6):461–3.CrossRefPubMed
11.
Zurück zum Zitat David M, et al. Intra-abdominal pressure monitoring by Surface Bioimpedance Estimation. J Phys: Conf Ser. 2019;1272(1):012013. David M, et al. Intra-abdominal pressure monitoring by Surface Bioimpedance Estimation. J Phys: Conf Ser. 2019;1272(1):012013.
12.
Zurück zum Zitat Tang H, et al. Deep Domain Adaptation for Predicting Intra-Abdominal pressure with multichannel attention Fusion Radar Chip. Adv Intell Syst. 2022;4(5):2100209.CrossRef Tang H, et al. Deep Domain Adaptation for Predicting Intra-Abdominal pressure with multichannel attention Fusion Radar Chip. Adv Intell Syst. 2022;4(5):2100209.CrossRef
13.
Zurück zum Zitat Tayebi S, et al. Non-invasive intra-abdominal pressure measurement by means of transient Radar Method: in Vitro Validation of a Novel Radar-Based Sensor. Sensors. 2021;21(18):5999.CrossRefPubMedPubMedCentral Tayebi S, et al. Non-invasive intra-abdominal pressure measurement by means of transient Radar Method: in Vitro Validation of a Novel Radar-Based Sensor. Sensors. 2021;21(18):5999.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat David M, et al. Non-invasive indirect monitoring of intra-abdominal pressure using microwave reflectometry: system design and proof-of-concept clinical trial. J Clin Monit Comput. 2021;35(6):1437–43.CrossRefPubMed David M, et al. Non-invasive indirect monitoring of intra-abdominal pressure using microwave reflectometry: system design and proof-of-concept clinical trial. J Clin Monit Comput. 2021;35(6):1437–43.CrossRefPubMed
15.
Zurück zum Zitat Cheatham ML, et al. The impact of body position on intra-abdominal pressure measurement: a multicenter analysis*. Crit Care Med; 2009. Cheatham ML, et al. The impact of body position on intra-abdominal pressure measurement: a multicenter analysis*. Crit Care Med; 2009.
16.
Zurück zum Zitat Cheatham ML et al. Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. II. Recommendations Intensive Care Med, 2007. 33(6): p. 951 – 62. Cheatham ML et al. Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. II. Recommendations Intensive Care Med, 2007. 33(6): p. 951 – 62.
17.
Zurück zum Zitat Malbrain ML. Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensive Care Med. 2004;30(3):357–71.CrossRefPubMed Malbrain ML. Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensive Care Med. 2004;30(3):357–71.CrossRefPubMed
18.
Zurück zum Zitat Malbrain ML, et al. Prevalence of intra-abdominal hypertension in critically ill patients: a multicentre epidemiological study. Intensive Care Med. 2004;30(5):822–9.CrossRefPubMed Malbrain ML, et al. Prevalence of intra-abdominal hypertension in critically ill patients: a multicentre epidemiological study. Intensive Care Med. 2004;30(5):822–9.CrossRefPubMed
19.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed
20.
Zurück zum Zitat Tayebi S et al. Pre-Clinical Validation of A Novel Continuous Intra-Abdominal Pressure Measurement Equipment (SERENNO) Life (Basel), 2022. 12(8). Tayebi S et al. Pre-Clinical Validation of A Novel Continuous Intra-Abdominal Pressure Measurement Equipment (SERENNO) Life (Basel), 2022. 12(8).
21.
22.
Zurück zum Zitat Malbrain ML, et al. Can the abdominal perimeter be used as an accurate estimation of intra-abdominal pressure? Crit Care Med. 2009;37(1):316–9.CrossRefPubMed Malbrain ML, et al. Can the abdominal perimeter be used as an accurate estimation of intra-abdominal pressure? Crit Care Med. 2009;37(1):316–9.CrossRefPubMed
23.
Zurück zum Zitat van Ramshorst GH, et al. Non-invasive measurement of intra-abdominal pressure: a preliminary study. Physiol Meas. 2008;29(8):N41–7.CrossRefPubMed van Ramshorst GH, et al. Non-invasive measurement of intra-abdominal pressure: a preliminary study. Physiol Meas. 2008;29(8):N41–7.CrossRefPubMed
24.
Zurück zum Zitat Tayebi S, et al. A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside. J Clin Monit Comput. 2021;35(1):51–70.CrossRefPubMed Tayebi S, et al. A concise overview of non-invasive intra-abdominal pressure measurement techniques: from bench to bedside. J Clin Monit Comput. 2021;35(1):51–70.CrossRefPubMed
Metadaten
Titel
Feasibility analysis of a novel non-invasive ultrasonographic method for the measurement of intra-abdominal pressure in the intensive care unit
verfasst von
Kay Choong See
Salar Tayebi
Chew Lai Sum
Jason Phua
Johan Stiens
Robert Wise
Amartya Mukhopadhyay
Manu L.N.G. Malbrain
Publikationsdatum
03.05.2023
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 5/2023
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-023-01024-2

Weitere Artikel der Ausgabe 5/2023

Journal of Clinical Monitoring and Computing 5/2023 Zur Ausgabe

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Häufigste Gründe für Brustschmerzen bei Kindern

06.05.2024 Pädiatrische Diagnostik Nachrichten

Akute Brustschmerzen sind ein Alarmsymptom par exellence, schließlich sind manche Auslöser lebensbedrohlich. Auch Kinder klagen oft über Schmerzen in der Brust. Ein Studienteam ist den Ursachen nachgegangen.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.