Skip to main content
Erschienen in: European Radiology 10/2012

01.10.2012 | Neuro

Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series

verfasst von: Laurent Pierot, Christophe Portefaix, Anne Boulin, Jean-Yves Gauvrit

Erschienen in: European Radiology | Ausgabe 10/2012

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To compare 3D-TOF magnetic resonance angiography (MRA) and contrast-enhanced MRA (CE-MRA) sequences at 3T in the follow-up of coiled aneurysms with digital subtracted angiography (DSA) as the gold standard.

Methods

DSA, 3D-TOF and CE-MRA were performed in a prospective series of 126 aneurysms in 96 patients (57 female, 39 male; age: 25–75 years, mean: 51.3 ± 11.3 years). The quality of aneurysm occlusion was assessed independently and anonymously by a core laboratory.

Results

Using DSA (gold standard technique), total occlusion was depicted in 57 aneurysms (45.2%), neck remnant in 34 aneurysms (27.0%) and aneurysm remnant in 35 aneurysms (27.8%). Sensitivity, specificity, positive predictive value and negative predictive value were very similar with 3D-TOF and CE-MRA. Visibility of coils was much better with 3D-TOF (95.2%) than with CE-MRA (23.0%) (P < 0.001). Also, substantial artefacts were less frequent with 3D-TOF (4.0%) than with CE-MRA (11.9%; P = 0.012).

Conclusions

In this large prospective series of patients with coiled aneurysms, at 3T 3D-TOF MRA was equivalent to CE-MRA for the evaluation of aneurysm occlusion, but coil visibility was superior at 3D-TOF. Thus the use of 3D-TOF at 3T is recommended for the follow-up of coiled intracranial aneurysms.

Key Points

• Different Magnetic Resonance (MR) imaging techniques are used to evaluate intracranial aneurysms.
At 3T MR, 3D-TOF and CE-MRA appear equivalent for evaluating coiled aneurysms..
Coils are better visualised on 3D-TOF than on CE-MRA.
Combined analysis of 3D-TOF and CE-MRA does not seem helpful.
At 3T, 3D-TOF techniques are recommended for monitoring patients with coiled aneurysms.
Literatur
1.
Zurück zum Zitat Molyneux AJ, Kerr RSC, Stratton I et al (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1262–1263CrossRef Molyneux AJ, Kerr RSC, Stratton I et al (2002) International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trial. Lancet 360:1262–1263CrossRef
2.
Zurück zum Zitat Pierot L, Spelle L, Vitry F, ATENA Investigators (2008) Clinical outcome of patients harbouring unruptured intracranial aneurysms treated by endovascular approach: results of the ATENA trial. Stroke 39:2497–2504PubMedCrossRef Pierot L, Spelle L, Vitry F, ATENA Investigators (2008) Clinical outcome of patients harbouring unruptured intracranial aneurysms treated by endovascular approach: results of the ATENA trial. Stroke 39:2497–2504PubMedCrossRef
3.
Zurück zum Zitat Ferns SP, Sprengers MES, von Rooij WJ et al (2009) Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates. Stroke 40:e523–e529PubMedCrossRef Ferns SP, Sprengers MES, von Rooij WJ et al (2009) Coiling of intracranial aneurysms: a systematic review on initial occlusion and reopening and retreatment rates. Stroke 40:e523–e529PubMedCrossRef
4.
Zurück zum Zitat Kaufmann TJ, Huston J, Mandrekar JN, Schleck CD, Thielen KR, Kallmes DF (2007) Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. Radiology 243:812–819PubMedCrossRef Kaufmann TJ, Huston J, Mandrekar JN, Schleck CD, Thielen KR, Kallmes DF (2007) Complications of diagnostic cerebral angiography: evaluation of 19,826 consecutive patients. Radiology 243:812–819PubMedCrossRef
5.
Zurück zum Zitat Boulin A, Pierot L (2001) Follow-up of intracranial aneurysms treated with detachable coils: comparison of gadolinium 3D time-of-flight MR angiography and digital subtraction angiography. Radiology 219:108–113PubMed Boulin A, Pierot L (2001) Follow-up of intracranial aneurysms treated with detachable coils: comparison of gadolinium 3D time-of-flight MR angiography and digital subtraction angiography. Radiology 219:108–113PubMed
6.
Zurück zum Zitat Pierot L, Delcourt C, Bouquigny F et al (2006) Follow-up of intracranial aneurysms selectively treated with coils: prospective evaluation of contrast-enhanced MR angiography. AJNR Am J Neuroradiol 27:744–749PubMed Pierot L, Delcourt C, Bouquigny F et al (2006) Follow-up of intracranial aneurysms selectively treated with coils: prospective evaluation of contrast-enhanced MR angiography. AJNR Am J Neuroradiol 27:744–749PubMed
7.
Zurück zum Zitat Kwee TC, Kwee RM (2007) MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis. Neuroradiology 49:703–713PubMedCrossRef Kwee TC, Kwee RM (2007) MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis. Neuroradiology 49:703–713PubMedCrossRef
8.
Zurück zum Zitat Urbach H, Dorenbeck U, von Falken hausen M et al (2008) Three-dimensional time-of-flight MR angiography at 3T compared to digital subtraction angiography in the follow-up of ruptured and coiled aneurysms. Neuroradiology 50:383–389PubMedCrossRef Urbach H, Dorenbeck U, von Falken hausen M et al (2008) Three-dimensional time-of-flight MR angiography at 3T compared to digital subtraction angiography in the follow-up of ruptured and coiled aneurysms. Neuroradiology 50:383–389PubMedCrossRef
9.
Zurück zum Zitat Anzalone N, Scomazzoni F, Cirillo M et al (2008) Follow-up of coiled aneurysms at 3T: comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography. AJNR Am J Neuroradiol 29:1530–1536PubMedCrossRef Anzalone N, Scomazzoni F, Cirillo M et al (2008) Follow-up of coiled aneurysms at 3T: comparison of 3D time-of-flight MR angiography and contrast-enhanced MR angiography. AJNR Am J Neuroradiol 29:1530–1536PubMedCrossRef
10.
Zurück zum Zitat Buhk JH, Kallenberg K, Mohr A, Dechent P, Knauth M (2008) No advantage of time-of-flight magnetic resonance angiography at 3 Tesla compared to 1.5T in the follow-up after endovascular treatment of cerebral aneurysms. Neuroradiology 50:855–861PubMedCrossRef Buhk JH, Kallenberg K, Mohr A, Dechent P, Knauth M (2008) No advantage of time-of-flight magnetic resonance angiography at 3 Tesla compared to 1.5T in the follow-up after endovascular treatment of cerebral aneurysms. Neuroradiology 50:855–861PubMedCrossRef
11.
Zurück zum Zitat Ramgren B, Siemund R, Cronqvist M et al (2008) Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA. Neuroradiology 50:947–954PubMedCrossRef Ramgren B, Siemund R, Cronqvist M et al (2008) Follow-up of intracranial aneurysms treated with detachable coils: comparison of 3D inflow MRA at 3T and 1.5T and contrast-enhanced MRA at 3T with DSA. Neuroradiology 50:947–954PubMedCrossRef
12.
Zurück zum Zitat Kau T, Gasser J, Celedin S et al (2009) MR angiographic follow-up of intracranial aneurysms treated with detachable coils: evaluation of a blood-pool contrast medium. AJNR Am J Neuroradiol 30:1524–1530PubMedCrossRef Kau T, Gasser J, Celedin S et al (2009) MR angiographic follow-up of intracranial aneurysms treated with detachable coils: evaluation of a blood-pool contrast medium. AJNR Am J Neuroradiol 30:1524–1530PubMedCrossRef
13.
Zurück zum Zitat Sprengers MES, Schaafsma JD, van Rooij WJ et al (2009) Evaluations of the occlusion status of coiled aneurysms with MR angiography at 3T: is contrast enhancement necessary? AJNR Am J Neuroradiol 30:1665–1671PubMedCrossRef Sprengers MES, Schaafsma JD, van Rooij WJ et al (2009) Evaluations of the occlusion status of coiled aneurysms with MR angiography at 3T: is contrast enhancement necessary? AJNR Am J Neuroradiol 30:1665–1671PubMedCrossRef
14.
Zurück zum Zitat Kaufmann TJ, Huston J, Cloft HJ et al (2010) A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms. AJNR Am J Neuroradiol 31:912–918PubMedCrossRef Kaufmann TJ, Huston J, Cloft HJ et al (2010) A prospective trial of 3T and 1.5T time-of-flight and contrast-enhanced MR angiography in the follow-up of coiled intracranial aneurysms. AJNR Am J Neuroradiol 31:912–918PubMedCrossRef
15.
Zurück zum Zitat Schaafsma JD, Velthuis BK, Majoie CBLM et al (2010) Intracranial aneurysms treated with coil placement: test characteristics of follow-up MR angiography—multicenter study. Radiology 256:209–218PubMedCrossRef Schaafsma JD, Velthuis BK, Majoie CBLM et al (2010) Intracranial aneurysms treated with coil placement: test characteristics of follow-up MR angiography—multicenter study. Radiology 256:209–218PubMedCrossRef
16.
Zurück zum Zitat Raymond J, Guilbert F, Weill A et al (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403PubMedCrossRef Raymond J, Guilbert F, Weill A et al (2003) Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils. Stroke 34:1398–1403PubMedCrossRef
17.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174PubMedCrossRef
18.
Zurück zum Zitat Kovacs A, Möhlenbruch M, Hadizadeh DR et al (2011) Noninvasive imaging after stent-assisted coiling of intracranial aneurysms: comparison of 3-T magnetic resonance imaging and 64-row multidetector computed tomography: a pilot study. J Comput Assist Tomogr 35:573–582PubMedCrossRef Kovacs A, Möhlenbruch M, Hadizadeh DR et al (2011) Noninvasive imaging after stent-assisted coiling of intracranial aneurysms: comparison of 3-T magnetic resonance imaging and 64-row multidetector computed tomography: a pilot study. J Comput Assist Tomogr 35:573–582PubMedCrossRef
19.
Zurück zum Zitat Buhk JH, Kallenberg K, Mohr A, Dechent P, Knauth M (2009) Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms—a comparative study with DSA and TOF-MRA. Eur Radiol 19:430–436PubMedCrossRef Buhk JH, Kallenberg K, Mohr A, Dechent P, Knauth M (2009) Evaluation of angiographic computed tomography in the follow-up after endovascular treatment of cerebral aneurysms—a comparative study with DSA and TOF-MRA. Eur Radiol 19:430–436PubMedCrossRef
20.
Zurück zum Zitat Johnston SC, Dowd CF, Higashida RT et al (2008) Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: the Cerebral Aneurysm Rerupture After Treatment (CARAT) study. Stroke 39:120–125PubMedCrossRef Johnston SC, Dowd CF, Higashida RT et al (2008) Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: the Cerebral Aneurysm Rerupture After Treatment (CARAT) study. Stroke 39:120–125PubMedCrossRef
21.
Zurück zum Zitat Sluzewski M, van Rooij WJ, Beute GN, Nijssen PC (2005) Late rebleeding of ruptured intracranial aneurysms treated with detachable coils. AJNR Am J Neuroradiol 26:2542–2549PubMed Sluzewski M, van Rooij WJ, Beute GN, Nijssen PC (2005) Late rebleeding of ruptured intracranial aneurysms treated with detachable coils. AJNR Am J Neuroradiol 26:2542–2549PubMed
22.
Zurück zum Zitat Kuo PH, Kanal E, Abu-Alfa CSE (2007) Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis. Radiology 27:2118–2120 Kuo PH, Kanal E, Abu-Alfa CSE (2007) Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis. Radiology 27:2118–2120
23.
Zurück zum Zitat Agid R, Willinsky RA, Lee SK, TerBrugge KG, Farb RI (2008) Characterization of aneurysm remnants after endovascular treatment: contrast-enhanced MR angiography versus catheter digital subtraction angiography. AJNR Am J Neuroradiol 29:1570–1574PubMedCrossRef Agid R, Willinsky RA, Lee SK, TerBrugge KG, Farb RI (2008) Characterization of aneurysm remnants after endovascular treatment: contrast-enhanced MR angiography versus catheter digital subtraction angiography. AJNR Am J Neuroradiol 29:1570–1574PubMedCrossRef
Metadaten
Titel
Follow-up of coiled intracranial aneurysms: comparison of 3D time-of-flight and contrast-enhanced magnetic resonance angiography at 3T in a large, prospective series
verfasst von
Laurent Pierot
Christophe Portefaix
Anne Boulin
Jean-Yves Gauvrit
Publikationsdatum
01.10.2012
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 10/2012
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-012-2466-6

Weitere Artikel der Ausgabe 10/2012

European Radiology 10/2012 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.