Skip to main content
Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 2/2019

13.02.2019 | Original Article

Comparison of force loss due to friction of different wire sizes and materials in conventional and new self-ligating orthodontic brackets during simulated canine retraction

verfasst von: Prof. Dr. Tarek El-Bialy, Ahmad Alobeid, Cornelius Dirk, Andreas Jäger, Ludger Keilig, Christoph Bourauel

Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | Ausgabe 2/2019

Einloggen, um Zugang zu erhalten

Abstract

Aims

The aim of this study was to compare force loss due to friction (Fr) during simulated canine retraction using different archwire dimensions and materials between conventional and new self-ligating brackets.

Methods

The tested brackets were (1) conventional brackets (Victory series, GAC twin and FLI twin), (2) self-ligating brackets (Damon-Q, FLI-SL, new/improved FLI-SL (I FLI-SL), SPEED, GAC innovation (R) and Ortho Classic) and (3) a low-friction bracket (Synergy). All brackets had a 0.022″ slot size. The tested archwires were stainless steel (0.018″; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″); nickel titanium (NiTi; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″) and titanium molybdenum alloy (TMA; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″). Canine retraction was experimentally simulated in a biomechanical set-up using a NiTi coil spring that delivered a force of 1 N. The simulated retraction path was up to 4 mm. Force loss due to friction was compared between groups using the Welch t‑test.

Results

Force loss due to friction increased with increasing archwire size. Also, TMA showed the highest and stainless steel the lowest force loss due to friction. FLI-SL brackets showed the lowest Fr (31%) and Ortho Classic showed the highest (67%).

Conclusions

Increasing wire size generally showed increasing force loss due to friction. FLI-SL brackets showed the lowest, while Ortho Classic showed the highest friction.
Literatur
1.
Zurück zum Zitat Alobeid A, El-Bialy T, Khawatmi S, Dirk C, Jäger A, Bourauel C (2017) Comparison of the force levels among labial and lingual self-ligating and conventional brackets in simulated misaligned teeth. Eur J Orthod 39:419–425CrossRefPubMed Alobeid A, El-Bialy T, Khawatmi S, Dirk C, Jäger A, Bourauel C (2017) Comparison of the force levels among labial and lingual self-ligating and conventional brackets in simulated misaligned teeth. Eur J Orthod 39:419–425CrossRefPubMed
2.
Zurück zum Zitat Andreasen GF, Quevedo FR (1970) Evaluation of friction forces in the 0.022 x 0.028 edgewise bracket in vitro. J Biomech 3:151–156CrossRefPubMed Andreasen GF, Quevedo FR (1970) Evaluation of friction forces in the 0.022 x 0.028 edgewise bracket in vitro. J Biomech 3:151–156CrossRefPubMed
3.
Zurück zum Zitat Articolo L, Kusy R (1999) Influence of angulation on the resistance of sliding in fixed appliances. Am J Orthod Dentofacial Orthop 115:39–51CrossRefPubMed Articolo L, Kusy R (1999) Influence of angulation on the resistance of sliding in fixed appliances. Am J Orthod Dentofacial Orthop 115:39–51CrossRefPubMed
4.
Zurück zum Zitat Bednar JR, Gruendeman GW, Sandrik JL (1991) A comparative study of frictional forces between orthodontic brackets and arch wires. Am J Orthod Dentofacial Orthop 100:513–522CrossRefPubMed Bednar JR, Gruendeman GW, Sandrik JL (1991) A comparative study of frictional forces between orthodontic brackets and arch wires. Am J Orthod Dentofacial Orthop 100:513–522CrossRefPubMed
5.
Zurück zum Zitat Berger LJ (1990) The influence of the SPEED bracket’s self-ligating design on force levels in tooth movement: A comparative in vitro study. Am J Orthod Dentofacial Orthop 97:219–228CrossRefPubMed Berger LJ (1990) The influence of the SPEED bracket’s self-ligating design on force levels in tooth movement: A comparative in vitro study. Am J Orthod Dentofacial Orthop 97:219–228CrossRefPubMed
6.
Zurück zum Zitat Bourauel C, Drescher D, Thier M (1990) Kraft-Momenten-Aufnehmer für die Kieferorthopädie. Feinwerktech Messtech 98:419–422 Bourauel C, Drescher D, Thier M (1990) Kraft-Momenten-Aufnehmer für die Kieferorthopädie. Feinwerktech Messtech 98:419–422
7.
Zurück zum Zitat Bourauel C, Drescher D, Thier M (1992) An experimental apparatus for the simulation of three-dimensional movements in orthodontics. J Biomed Eng 14:371–378CrossRefPubMed Bourauel C, Drescher D, Thier M (1992) An experimental apparatus for the simulation of three-dimensional movements in orthodontics. J Biomed Eng 14:371–378CrossRefPubMed
8.
Zurück zum Zitat Braun S, Bluestein M, Moore K, Benson G (1999) Friction in perspective. Am J Orthod Dentofacial Orthop 115:619–627CrossRefPubMed Braun S, Bluestein M, Moore K, Benson G (1999) Friction in perspective. Am J Orthod Dentofacial Orthop 115:619–627CrossRefPubMed
9.
Zurück zum Zitat Burrow SJ (2009) Friction and resistance to sliding in orthodontics: A critical review. Am J Orthod Dentofacial Orthop 135:442–447CrossRefPubMed Burrow SJ (2009) Friction and resistance to sliding in orthodontics: A critical review. Am J Orthod Dentofacial Orthop 135:442–447CrossRefPubMed
10.
Zurück zum Zitat Cacciafesta V, Sfondrini MF, Ricciardi A, Scribante A, Klersy C, Auricchio F (2003) Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations. Am J Orthod Dentofacial Orthop 124:395–402CrossRefPubMed Cacciafesta V, Sfondrini MF, Ricciardi A, Scribante A, Klersy C, Auricchio F (2003) Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combinations. Am J Orthod Dentofacial Orthop 124:395–402CrossRefPubMed
11.
Zurück zum Zitat Dholakia KD (2012) Friction and anchorage loading revisited. Orthodontics (Chic) 13:200–209 Dholakia KD (2012) Friction and anchorage loading revisited. Orthodontics (Chic) 13:200–209
12.
Zurück zum Zitat Drescher D, Bourauel C, Schumacher HA (1990) The loss of force by friction in arch-guided tooth movement. Fortschr Kieferorthop 51:99–105CrossRefPubMed Drescher D, Bourauel C, Schumacher HA (1990) The loss of force by friction in arch-guided tooth movement. Fortschr Kieferorthop 51:99–105CrossRefPubMed
13.
Zurück zum Zitat Drescher D, Bourauel C, Thier M (1991) Application of the orthodontic measurement and simulation system (OMSS) in orthodontics. Eur J Orthod 13:169–178CrossRefPubMed Drescher D, Bourauel C, Thier M (1991) Application of the orthodontic measurement and simulation system (OMSS) in orthodontics. Eur J Orthod 13:169–178CrossRefPubMed
14.
Zurück zum Zitat Ehsani S, Mandich M, El-Bialy TH, Flores-Mir C (2009) Frictional resistance in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review. Angle Orthod 79:592–601PubMed Ehsani S, Mandich M, El-Bialy TH, Flores-Mir C (2009) Frictional resistance in self-ligating orthodontic brackets and conventionally ligated brackets: A systematic review. Angle Orthod 79:592–601PubMed
15.
Zurück zum Zitat Feynman RP, Leighton RB, Sands M (2010) Mainly mechanics, radiation, and heat. Feynman lectures on physics. The new millenium edition, vol 1. Perseus Books, Philadelphia, pp 12-3–12-6 Feynman RP, Leighton RB, Sands M (2010) Mainly mechanics, radiation, and heat. Feynman lectures on physics. The new millenium edition, vol 1. Perseus Books, Philadelphia, pp 12-3–12-6
16.
Zurück zum Zitat Griffiths HS, Sherriff M, Ireland AJ (2005) Resistance to sliding with 3 types of elastomeric modules. Am J Orthod Dentofacial Orthop 127:670–675CrossRefPubMed Griffiths HS, Sherriff M, Ireland AJ (2005) Resistance to sliding with 3 types of elastomeric modules. Am J Orthod Dentofacial Orthop 127:670–675CrossRefPubMed
17.
Zurück zum Zitat Hain M, Dhopatkar A, Rock P (2006) A comparison of different ligation methods on friction. Am J Orthod Dentofacial Orthop 130:666–670CrossRefPubMed Hain M, Dhopatkar A, Rock P (2006) A comparison of different ligation methods on friction. Am J Orthod Dentofacial Orthop 130:666–670CrossRefPubMed
18.
Zurück zum Zitat Halazonetis DJ (2007) Friction might increase anchorage loading. Am J Orthod Dentofacial Orthop 131:699–700CrossRefPubMed Halazonetis DJ (2007) Friction might increase anchorage loading. Am J Orthod Dentofacial Orthop 131:699–700CrossRefPubMed
19.
Zurück zum Zitat Henriques JFC, Higa RH, Semenara NT, Janson G, Fernandes TMF, Sathler R (2017) Evaluation of deflection forces of orthodontic wires with different ligation types. Braz Oral Res 31:e49CrossRefPubMed Henriques JFC, Higa RH, Semenara NT, Janson G, Fernandes TMF, Sathler R (2017) Evaluation of deflection forces of orthodontic wires with different ligation types. Braz Oral Res 31:e49CrossRefPubMed
20.
Zurück zum Zitat Husmann P, Bourauel C, Wessinger M, Jäger A (2002) The frictional behavior of coated guiding archwires. J Orofac Orthop 63:199–211CrossRefPubMed Husmann P, Bourauel C, Wessinger M, Jäger A (2002) The frictional behavior of coated guiding archwires. J Orofac Orthop 63:199–211CrossRefPubMed
21.
Zurück zum Zitat Jost-Brinkmann P, Miethke RR (1991) The effect of physiological tooth mobility on the friction between the bracket and the arch. Fortschr Kieferorthop 52:102–109CrossRefPubMed Jost-Brinkmann P, Miethke RR (1991) The effect of physiological tooth mobility on the friction between the bracket and the arch. Fortschr Kieferorthop 52:102–109CrossRefPubMed
22.
Zurück zum Zitat Kim TK, Kim KD, Baek SH (2008) Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont system. Am J Orthod Dentofacial Orthop 133(187):e15–e24 Kim TK, Kim KD, Baek SH (2008) Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont system. Am J Orthod Dentofacial Orthop 133(187):e15–e24
23.
Zurück zum Zitat Kusy RP, Whitley JQ (1990) Effects of surface roughness on the coefficients of friction in model orthodontic systems. J Biomech 23:913–925CrossRefPubMed Kusy RP, Whitley JQ (1990) Effects of surface roughness on the coefficients of friction in model orthodontic systems. J Biomech 23:913–925CrossRefPubMed
24.
Zurück zum Zitat Kusy RP, Whitley JQ (1997) Friction between different wire-bracket configurations and materials. Semin Orthod 3:166–177CrossRefPubMed Kusy RP, Whitley JQ (1997) Friction between different wire-bracket configurations and materials. Semin Orthod 3:166–177CrossRefPubMed
25.
Zurück zum Zitat Kusy RP, Whitley JQ (1999) Influence of archwire and bracket dimensions on sliding mechanics: Derivations and determinations of the critical contact angles for binding. Eur J Orthod 21:199–208CrossRefPubMed Kusy RP, Whitley JQ (1999) Influence of archwire and bracket dimensions on sliding mechanics: Derivations and determinations of the critical contact angles for binding. Eur J Orthod 21:199–208CrossRefPubMed
26.
Zurück zum Zitat Kusy RP (2000) Ongoing innovations in biomechanics and materials for the new millennium. Angle Orthod 70:366–376PubMed Kusy RP (2000) Ongoing innovations in biomechanics and materials for the new millennium. Angle Orthod 70:366–376PubMed
27.
Zurück zum Zitat Loftus B, Årtun J, Nichollis J, Alonzo T, Stoner J (1999) Evaluation of friction during sliding tooth movement in various bracket-arch wire combinations. Am J Orthod Dentofacial Orthop 116:336–345CrossRefPubMed Loftus B, Årtun J, Nichollis J, Alonzo T, Stoner J (1999) Evaluation of friction during sliding tooth movement in various bracket-arch wire combinations. Am J Orthod Dentofacial Orthop 116:336–345CrossRefPubMed
28.
Zurück zum Zitat Montasser MA, El-Bialy T, Keilig L, Reimann S, Jäger A, Bourauel C (2014) Force loss in archwire-guided tooth movement of conventional and self-ligating brackets. Eur J Orthod 36:31–38CrossRefPubMed Montasser MA, El-Bialy T, Keilig L, Reimann S, Jäger A, Bourauel C (2014) Force loss in archwire-guided tooth movement of conventional and self-ligating brackets. Eur J Orthod 36:31–38CrossRefPubMed
29.
Zurück zum Zitat O’Reilly D, Dowling PA, Lagerström L, Swartz ML (1999) An ex vivo investigation into the effect of bracket displacement on the resistance to sliding. Br J Orthod 26:219–227CrossRefPubMed O’Reilly D, Dowling PA, Lagerström L, Swartz ML (1999) An ex vivo investigation into the effect of bracket displacement on the resistance to sliding. Br J Orthod 26:219–227CrossRefPubMed
30.
Zurück zum Zitat Phukaoluan A, Khantachawana A, Kaewtatip P, Dechkunakorn S, Anuwongnukroh N, Santiwong P, Kajornchaiyakul J (2017) Comparison of friction forces between stainless orthodontic steel brackets and TiNi wires in wet and dry conditions. Int Orthod 15:13–24PubMed Phukaoluan A, Khantachawana A, Kaewtatip P, Dechkunakorn S, Anuwongnukroh N, Santiwong P, Kajornchaiyakul J (2017) Comparison of friction forces between stainless orthodontic steel brackets and TiNi wires in wet and dry conditions. Int Orthod 15:13–24PubMed
31.
Zurück zum Zitat Proffit WR, Fields HW, Ackerman J, Bailey L, Tulloch J (2000) Biomechanics and mechanics. In: Proffit WR, Fields HW (eds) Contemporary orthodontics, 3rd edn. Mosby, St Louis, pp 346–347 Proffit WR, Fields HW, Ackerman J, Bailey L, Tulloch J (2000) Biomechanics and mechanics. In: Proffit WR, Fields HW (eds) Contemporary orthodontics, 3rd edn. Mosby, St Louis, pp 346–347
32.
Zurück zum Zitat Rabiee SM, Eftekhari SZ, Arash V, Amozegar N, Fathi A, Tavanafar S, Bijani A (2017) Effect of CO2 laser power intensity on the surface morphology and friction behavior of alumina ceramic brackets. Microsc Res Tech 80:923–929CrossRefPubMed Rabiee SM, Eftekhari SZ, Arash V, Amozegar N, Fathi A, Tavanafar S, Bijani A (2017) Effect of CO2 laser power intensity on the surface morphology and friction behavior of alumina ceramic brackets. Microsc Res Tech 80:923–929CrossRefPubMed
33.
Zurück zum Zitat Reicheneder CA, Baumert U, Gedrange T, Proff P, Faltermeier A, Muessig D (2007) Frictional properties of aesthetic brackets. Eur J Orthod 29:359–365CrossRefPubMed Reicheneder CA, Baumert U, Gedrange T, Proff P, Faltermeier A, Muessig D (2007) Frictional properties of aesthetic brackets. Eur J Orthod 29:359–365CrossRefPubMed
34.
Zurück zum Zitat Riley JL, Garrett SG, Moon PC (1979) Frictional forces of ligated plastic and metal edgewise brackets [Master’s thesis]. Virginia Commonwealth University, Medical College of Virginia, Richmond, Virginia Riley JL, Garrett SG, Moon PC (1979) Frictional forces of ligated plastic and metal edgewise brackets [Master’s thesis]. Virginia Commonwealth University, Medical College of Virginia, Richmond, Virginia
35.
Zurück zum Zitat Savoldi F, Visconti L, Dalessandri D, Bonetti S, Tsoi JKH, Matinlinna JP, Paganelli C (2017) In vitro evaluation of the influence of velocity on sliding resistance of stainless steel arch wires in a self-ligating orthodontic bracket. Orthod Craniofac Res 20:119–125CrossRefPubMed Savoldi F, Visconti L, Dalessandri D, Bonetti S, Tsoi JKH, Matinlinna JP, Paganelli C (2017) In vitro evaluation of the influence of velocity on sliding resistance of stainless steel arch wires in a self-ligating orthodontic bracket. Orthod Craniofac Res 20:119–125CrossRefPubMed
36.
Zurück zum Zitat Schumacher HA, Bourauel C, Drescher D (1990) The effect of the ligature on the friction between bracket and arch. Fortschr Kieferorthop 51:106–116CrossRefPubMed Schumacher HA, Bourauel C, Drescher D (1990) The effect of the ligature on the friction between bracket and arch. Fortschr Kieferorthop 51:106–116CrossRefPubMed
37.
Zurück zum Zitat Shivapuja PK, Berger JA (1994) A comparative study of conventional ligation and self-ligation bracket systems. Am J Orthod Dentofacial Orthop 106:472–480CrossRefPubMed Shivapuja PK, Berger JA (1994) A comparative study of conventional ligation and self-ligation bracket systems. Am J Orthod Dentofacial Orthop 106:472–480CrossRefPubMed
38.
Zurück zum Zitat Southard TE, Marshall SD, Grosland NM (2007) Friction does not increase anchorage loading. Am J Orthod Dentofacial Orthop 31:412–414CrossRef Southard TE, Marshall SD, Grosland NM (2007) Friction does not increase anchorage loading. Am J Orthod Dentofacial Orthop 31:412–414CrossRef
39.
Zurück zum Zitat Sridharan K, Sandbhor S, Rajasekaran UB, Sam G, Ramees MM, Abraham EA (2017) An in vitro evaluation of friction characteristics of conventional stainless steel and self-ligating stainless steel brackets with different dimensions of archwires in various bracket-archwire combination. J Contemp Dent Pract 18:660–664CrossRefPubMed Sridharan K, Sandbhor S, Rajasekaran UB, Sam G, Ramees MM, Abraham EA (2017) An in vitro evaluation of friction characteristics of conventional stainless steel and self-ligating stainless steel brackets with different dimensions of archwires in various bracket-archwire combination. J Contemp Dent Pract 18:660–664CrossRefPubMed
40.
Zurück zum Zitat Wichelhaus A, Geserick M, Hibst R, Sander FG (2005) The effect of surface treatment and clinical use on friction in NiTi orthodontic wires. Dent Mater 21:938–945CrossRefPubMed Wichelhaus A, Geserick M, Hibst R, Sander FG (2005) The effect of surface treatment and clinical use on friction in NiTi orthodontic wires. Dent Mater 21:938–945CrossRefPubMed
41.
Zurück zum Zitat Taylor N, Ison K (1996) Frictional resistance between orthodontic brackets and archwires in the buccal segments. Angle Orthod 66:215–221PubMed Taylor N, Ison K (1996) Frictional resistance between orthodontic brackets and archwires in the buccal segments. Angle Orthod 66:215–221PubMed
42.
Zurück zum Zitat Tecco S, Di Iorio D, Cordasco G, Verrocchi I, Festa F (2007) An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance. Eur J Orthod 29:390–397CrossRefPubMed Tecco S, Di Iorio D, Cordasco G, Verrocchi I, Festa F (2007) An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance. Eur J Orthod 29:390–397CrossRefPubMed
43.
Zurück zum Zitat Thorstenson GA, Kusy RP (2002) Comparison of resistance to sliding between different self-ligating brackets with second order angulation in the dry and saliva states. Am J Orthod Dentofacial Orthop 121:472–482CrossRefPubMed Thorstenson GA, Kusy RP (2002) Comparison of resistance to sliding between different self-ligating brackets with second order angulation in the dry and saliva states. Am J Orthod Dentofacial Orthop 121:472–482CrossRefPubMed
44.
Zurück zum Zitat Tidy D (1989) Frictional forces in fixed appliances. Am J Orthod Dentofacial Orthop 96:249–254CrossRefPubMed Tidy D (1989) Frictional forces in fixed appliances. Am J Orthod Dentofacial Orthop 96:249–254CrossRefPubMed
45.
Zurück zum Zitat Whitley JQ, Kusy RP (2007) Influence of interbracket distances on the resistance to sliding of orthodontic appliances. Am J Orthod Dentofacial Orthop 132:360–372CrossRefPubMed Whitley JQ, Kusy RP (2007) Influence of interbracket distances on the resistance to sliding of orthodontic appliances. Am J Orthod Dentofacial Orthop 132:360–372CrossRefPubMed
46.
Zurück zum Zitat Yamaguchi K, Nanda RS, Morimoto N, Oda Y (1996) A study of force application, amount of retarding force, and bracket width in sliding mechanics. Am J Orthod Dentofacial Orthop 109:50–56CrossRefPubMed Yamaguchi K, Nanda RS, Morimoto N, Oda Y (1996) A study of force application, amount of retarding force, and bracket width in sliding mechanics. Am J Orthod Dentofacial Orthop 109:50–56CrossRefPubMed
47.
Zurück zum Zitat Yeh CL, Kusnoto B, Viana G, Evans CA, Drummond JL (2007) In-vitro evaluation of frictional resistance between brackets with passive-ligation designs. Am J Orthod Dentofacial Orthop 131(704):e11–e22 Yeh CL, Kusnoto B, Viana G, Evans CA, Drummond JL (2007) In-vitro evaluation of frictional resistance between brackets with passive-ligation designs. Am J Orthod Dentofacial Orthop 131(704):e11–e22
Metadaten
Titel
Comparison of force loss due to friction of different wire sizes and materials in conventional and new self-ligating orthodontic brackets during simulated canine retraction
verfasst von
Prof. Dr. Tarek El-Bialy
Ahmad Alobeid
Cornelius Dirk
Andreas Jäger
Ludger Keilig
Christoph Bourauel
Publikationsdatum
13.02.2019
Verlag
Springer Medizin
Erschienen in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Ausgabe 2/2019
Print ISSN: 1434-5293
Elektronische ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-019-00168-8

Weitere Artikel der Ausgabe 2/2019

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 2/2019 Zur Ausgabe

Mitteilungen der DGKFO

Mitteilungen der DGKFO

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.