Skip to main content
Erschienen in: European Radiology 7/2003

01.07.2003 | Vascular–Interventional

Multicenter phase-II trial of safety and efficacy of NC100150 for steady-state contrast-enhanced peripheral magnetic resonance angiography

verfasst von: Tim Leiner, Kai Yiu J. A. M. Ho, Vincent B. Ho, Georg Bongartz, Willem P. T. M. Mali, Wenche Rasch, Jos M. A. van Engelshoven

Erschienen in: European Radiology | Ausgabe 7/2003

Einloggen, um Zugang zu erhalten

Abstract.

The aim of this study was to test the safety and efficacy of NC100150 injection for steady-state contrast-enhanced peripheral MR angiography in a multicentre phase-II trial. Thirty-three patients underwent steady-state NC100150 enhanced MR angiography (5 mg Fe/kg body weight) of the aortoiliac and femoropopliteal arteries. Safety assessment consisted of pre- and post-injection (2, 24 and 72 h) monitoring of vital signs, physical examination as well as laboratory and electrocardiographic parameters. To determine sensitivity and specificity for detection of haemodynamically significant stenoses (HSS; >50% reduction of luminal diameter) MR angiograms were compared with intra-arterial digital subtraction angiography (IA DSA), which was considered the standard of reference. In 33 patients a mean of 12.8 ml NC100150 was injected. Eleven patients reported 13 mild and 2 moderate adverse events. Five mild and one moderate adverse event were considered due to NC100150 injection. There were no significant changes in vital signs, laboratory or electrocardiographic parameters. Sensitivity and specificity (in percent) for detection of HSS were 87 and 64, 56 and 76, and 75 and 84, for iliac, femoral and popliteal arteries, respectively. NC100150 high-resolution steady-state MR angiography can be performed safely and is feasible for the detection of peripheral arterial HSS, but is as yet not a clinically useful alternative to conventional gadolinium-enhanced MR angiography.
Literatur
1.
Zurück zum Zitat Ho KYJAM, Leiner T, de Haan MW, Kessels AGH, Kitslaar PJEHM, van Engelshoven JMA (1998) Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography. Radiology 206:683–692CrossRefPubMed Ho KYJAM, Leiner T, de Haan MW, Kessels AGH, Kitslaar PJEHM, van Engelshoven JMA (1998) Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography. Radiology 206:683–692CrossRefPubMed
2.
Zurück zum Zitat Meaney JFM, Ridgway JP, Chakraverty S et al. (1999) Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience. Radiology 211:59–67CrossRefPubMed Meaney JFM, Ridgway JP, Chakraverty S et al. (1999) Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience. Radiology 211:59–67CrossRefPubMed
3.
Zurück zum Zitat Ho VB, Choyke PL, Foo TK et al. (1999) Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress. J Magn Reson Imaging 10:376–388CrossRefPubMed Ho VB, Choyke PL, Foo TK et al. (1999) Automated bolus chase peripheral MR angiography: initial practical experiences and future directions of this work-in-progress. J Magn Reson Imaging 10:376–388CrossRefPubMed
4.
Zurück zum Zitat Ruehm SG, Hany TF, Pfammatter T, Schneider E, Ladd M, Debatin JF (2000) Pelvic and lower extremity arterial imaging: diagnostic performance of three-dimensional contrast-enhanced MR angiography. Am J Roentgenol 174:1127–1135CrossRef Ruehm SG, Hany TF, Pfammatter T, Schneider E, Ladd M, Debatin JF (2000) Pelvic and lower extremity arterial imaging: diagnostic performance of three-dimensional contrast-enhanced MR angiography. Am J Roentgenol 174:1127–1135CrossRef
5.
Zurück zum Zitat Shellock FG, Kanal E (1999) Safety of magnetic resonance imaging contrast agents. J Magn Reson Imaging 10:477–484CrossRefPubMed Shellock FG, Kanal E (1999) Safety of magnetic resonance imaging contrast agents. J Magn Reson Imaging 10:477–484CrossRefPubMed
6.
Zurück zum Zitat Kroft LJ, de Roos A (1999) Blood pool contrast agents for cardiovascular MR imaging. J Magn Reson Imaging 10:395–403CrossRefPubMed Kroft LJ, de Roos A (1999) Blood pool contrast agents for cardiovascular MR imaging. J Magn Reson Imaging 10:395–403CrossRefPubMed
7.
Zurück zum Zitat Stillman AE, Wilke N, Li D, Haacke EM, McLaughlan S (1996) Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: studies in human patients. J Comput Assist Tomogr 20:51–55CrossRefPubMed Stillman AE, Wilke N, Li D, Haacke EM, McLaughlan S (1996) Ultrasmall superparamagnetic iron oxide to enhance MRA of the renal and coronary arteries: studies in human patients. J Comput Assist Tomogr 20:51–55CrossRefPubMed
8.
Zurück zum Zitat Anzai Y, Prince MR, Chenevert TL et al. (1997) MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent. J Magn Reson Imaging 7:209–214CrossRefPubMed Anzai Y, Prince MR, Chenevert TL et al. (1997) MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent. J Magn Reson Imaging 7:209–214CrossRefPubMed
9.
Zurück zum Zitat Taylor AM, Panting JR, Keegan J et al. (1999) Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging 9:220–227CrossRefPubMed Taylor AM, Panting JR, Keegan J et al. (1999) Safety and preliminary findings with the intravascular contrast agent NC100150 injection for MR coronary angiography. J Magn Reson Imaging 9:220–227CrossRefPubMed
10.
Zurück zum Zitat Weishaupt D, Ruehm SG, Binkert CA et al. (2000) Equilibrium-phase MR angiography of the aortoiliac and renal arteries using a blood pool contrast agent. Am J Roentgenol 175:189–195CrossRef Weishaupt D, Ruehm SG, Binkert CA et al. (2000) Equilibrium-phase MR angiography of the aortoiliac and renal arteries using a blood pool contrast agent. Am J Roentgenol 175:189–195CrossRef
11.
Zurück zum Zitat Kellar KE, Fujii DK, Gunther WH et al. (2000) NC100150 Injection, a preparation of optimized iron oxide nanoparticles for positive-contrast MR angiography. J Magn Reson Imaging 11:488–494CrossRefPubMed Kellar KE, Fujii DK, Gunther WH et al. (2000) NC100150 Injection, a preparation of optimized iron oxide nanoparticles for positive-contrast MR angiography. J Magn Reson Imaging 11:488–494CrossRefPubMed
12.
Zurück zum Zitat Panting JR, Taylor AM, Gatehouse PD et al. (1999) First-pass myocardial perfusion imaging and equilibrium signal changes using the intravascular contrast agent NC100150 injection. J Magn Reson Imaging 10:404–410CrossRefPubMed Panting JR, Taylor AM, Gatehouse PD et al. (1999) First-pass myocardial perfusion imaging and equilibrium signal changes using the intravascular contrast agent NC100150 injection. J Magn Reson Imaging 10:404–410CrossRefPubMed
13.
Zurück zum Zitat International Conference on Harmonisation (ICH) ICH harmonised tripartite guideline for good clinical practice. Brookwood Medical Publications, Surrey, 1996 International Conference on Harmonisation (ICH) ICH harmonised tripartite guideline for good clinical practice. Brookwood Medical Publications, Surrey, 1996
14.
Zurück zum Zitat Baker E, Morgan EH (1994) Iron transport. In: Brock JH, Halliday JW, Pippard MJ, Powell LW (eds) Iron metabolism in health and disease. Saunders, London Baker E, Morgan EH (1994) Iron transport. In: Brock JH, Halliday JW, Pippard MJ, Powell LW (eds) Iron metabolism in health and disease. Saunders, London
15.
Zurück zum Zitat Wildermuth S, Dubno R, Romanowski J et al. (1998) Open-label, phase 1 trial of a new blood pool contrast agent (NC100150) in 12 healthy volunteers: safety and vascular imaging characteristics (abstr). In: Proc Sixth Meeting of the International Society for Magnetic Resonance in Medicine. International Society for Magnetic Resonance in Medicine, Berkeley, Calif., p 48 Wildermuth S, Dubno R, Romanowski J et al. (1998) Open-label, phase 1 trial of a new blood pool contrast agent (NC100150) in 12 healthy volunteers: safety and vascular imaging characteristics (abstr). In: Proc Sixth Meeting of the International Society for Magnetic Resonance in Medicine. International Society for Magnetic Resonance in Medicine, Berkeley, Calif., p 48
16.
Zurück zum Zitat Nelemans PJ, Leiner T, de Vet HC, van Engelshoven JM (2000) Peripheral arterial disease: meta-analysis of the diagnostic performance of MR angiography. Radiology 217:105–114CrossRefPubMed Nelemans PJ, Leiner T, de Vet HC, van Engelshoven JM (2000) Peripheral arterial disease: meta-analysis of the diagnostic performance of MR angiography. Radiology 217:105–114CrossRefPubMed
17.
Zurück zum Zitat Koelemay MJ, Lijmer JG, Stoker J, Legemate DA, Bossuyt PM (2001) Magnetic resonance angiography for the evaluation of lower extremity arterial disease: a meta-analysis. J Am Med Assoc 285:1338–1345CrossRef Koelemay MJ, Lijmer JG, Stoker J, Legemate DA, Bossuyt PM (2001) Magnetic resonance angiography for the evaluation of lower extremity arterial disease: a meta-analysis. J Am Med Assoc 285:1338–1345CrossRef
18.
Zurück zum Zitat Grist TM, Korosec FR, Peters DC et al. (1998) Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 207:539–544CrossRefPubMed Grist TM, Korosec FR, Peters DC et al. (1998) Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 207:539–544CrossRefPubMed
19.
Zurück zum Zitat Ho KYJAM, Leiner T, van Engelshoven JMA (1999) First-pass bloodpool-enhanced MRA of the peripheral arteries as an aid to separation of arteries from veins in high-resolution bloodpool-enhanced MRA. Radiology 213(P):481CrossRef Ho KYJAM, Leiner T, van Engelshoven JMA (1999) First-pass bloodpool-enhanced MRA of the peripheral arteries as an aid to separation of arteries from veins in high-resolution bloodpool-enhanced MRA. Radiology 213(P):481CrossRef
20.
Zurück zum Zitat Foo TKF, Ho VB, Hood MN, Hess SL, Choyke PL (2001) Preferential arterial imaging using gated thick-slice gadolinium-enhanced phase contrast acquisition in peripheral MRA. J Magn Reson Imaging 13:714–721CrossRefPubMed Foo TKF, Ho VB, Hood MN, Hess SL, Choyke PL (2001) Preferential arterial imaging using gated thick-slice gadolinium-enhanced phase contrast acquisition in peripheral MRA. J Magn Reson Imaging 13:714–721CrossRefPubMed
21.
Zurück zum Zitat Tizon X, Smedby O (2002) Segmentation with grey-scale connectedness can separate arteries and veins in MRA. J Magn Reson Imaging 15:438–445CrossRefPubMed Tizon X, Smedby O (2002) Segmentation with grey-scale connectedness can separate arteries and veins in MRA. J Magn Reson Imaging 15:438–445CrossRefPubMed
Metadaten
Titel
Multicenter phase-II trial of safety and efficacy of NC100150 for steady-state contrast-enhanced peripheral magnetic resonance angiography
verfasst von
Tim Leiner
Kai Yiu J. A. M. Ho
Vincent B. Ho
Georg Bongartz
Willem P. T. M. Mali
Wenche Rasch
Jos M. A. van Engelshoven
Publikationsdatum
01.07.2003
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 7/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-002-1791-6

Weitere Artikel der Ausgabe 7/2003

European Radiology 7/2003 Zur Ausgabe

PET kann infarktgefährdete Koronararterien entdecken

04.06.2024 Koronare Herzerkrankung Nachrichten

Der Nachweis aktiver Plaques mittels 18F-Natriumfluorid-PET hilft nicht nur, infarktgefährdete Patienten, sondern auch infarktgefährdete Koronararterien zu erkennen. Von einer gezielten Behandlung vulnerabler Plaques ist man trotzdem weit entfernt.

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.