Skip to main content
Erschienen in: European Radiology 7/2015

01.07.2015 | Cardiac

Characteristics of aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve morphology

verfasst von: Hong Ju Shin, Je Kyoun Shin, Hyun Kun Chee, Jun Suk Kim, Sung Min Ko

Erschienen in: European Radiology | Ausgabe 7/2015

Einloggen, um Zugang zu erhalten

Abstract

Objective

To characterize aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve (BAV) morphology using computed tomography (CT) and surgical findings.

Methods

We retrospectively enrolled 209 patients with BAVs who underwent transthoracic echocardiography (TTE) and CT. BAVs were classified as anterior-posterior (BAV-AP) or lateral (BAV-LA) orientation of the cusps and divided according to the presence (raphe+) or absence (raphe–) of a raphe. Ascending aortic dimensions were measured by CT at four levels.

Results

BAV-AP was present in 129 patients (61.7 %) and raphe+ in 120 (57.4 %). Sixty-nine patients (33.0 %) had aortic regurgitation (AR), 70 (33.5 %) had aortic stenosis (AS), and 58 (27.8 %) had combined AS and AR. AR was more common in patients with BAV-AP and raphe+; AS was more common with BAV-LA and raphe–.Annulus/body surface area and tubular portion/body surface area diameters in patients with BAV-AP (17.1 ± 2.3 mm/m2 and 24.2 ± 5.3 mm/m2, respectively) and raphe+ (17.3 ± 2.2 mm/m2 and 24.2 ± 5.5 mm/m2, respectively) were significantly different from those with BAV-LA (15.8 ± 1.9 mm/m2 and 26.4 ± 5.5 mm/m2, respectively) and raphe– (15.7 ± 1.9 mm/m2 and 26.2 ± 5.4 mm/m2, respectively).

Conclusion

The morphological characteristics of BAV might be associated with the type of valvular dysfunction, and degree and location of an ascending aorta dilatation.

Key points

The BAV-AP type had more frequent aortic regurgitation, raphe, and a larger aortic annulus.
BAV without raphe had more frequent aortic stenosis and mid-ascending aorta dilatation.
CT allows assessment of the morphological characteristics of BAV and associated aortopathy.
Literatur
1.
Zurück zum Zitat Siu SC, Silversides CK (2010) Bicuspid aortic valve disease. J Am Coll Cardiol 55:2789–2800PubMedCrossRef Siu SC, Silversides CK (2010) Bicuspid aortic valve disease. J Am Coll Cardiol 55:2789–2800PubMedCrossRef
2.
Zurück zum Zitat Fernandes SM, Sanders SP, Khairy P et al (2004) Morphology of bicuspid aortic valve in children and adolescents. J Am Coll Cardiol 44:1648–1651PubMedCrossRef Fernandes SM, Sanders SP, Khairy P et al (2004) Morphology of bicuspid aortic valve in children and adolescents. J Am Coll Cardiol 44:1648–1651PubMedCrossRef
3.
Zurück zum Zitat Jassal DS, Bhagirath KM, Tam JW et al (2010) Association of bicuspid aortic valve morphology and aortic root dimensions: a substudy of the aortic stenosis progression observation measuring effects of rosuvastatin (ASTRONOMER) study. Echocardiography 27:174–179PubMedCrossRef Jassal DS, Bhagirath KM, Tam JW et al (2010) Association of bicuspid aortic valve morphology and aortic root dimensions: a substudy of the aortic stenosis progression observation measuring effects of rosuvastatin (ASTRONOMER) study. Echocardiography 27:174–179PubMedCrossRef
4.
Zurück zum Zitat Alkadhi H, Leschka S, Trindade PT et al (2010) Cardiac CT for the differentiation of bicuspid and tricuspid valves: comparison with echocardiography and surgery. AJR Am J Roentgenol 195:900–908PubMedCrossRef Alkadhi H, Leschka S, Trindade PT et al (2010) Cardiac CT for the differentiation of bicuspid and tricuspid valves: comparison with echocardiography and surgery. AJR Am J Roentgenol 195:900–908PubMedCrossRef
5.
Zurück zum Zitat Ocak I, Lacomis JM, Deible CR, Pealer K, Parag Y, Knollmann F (2009) The aortic root: comparison of measurements from ECG-gated CT angiography with transthoracic echocardiography. J Thorac Imaging 24:223–226PubMedCrossRef Ocak I, Lacomis JM, Deible CR, Pealer K, Parag Y, Knollmann F (2009) The aortic root: comparison of measurements from ECG-gated CT angiography with transthoracic echocardiography. J Thorac Imaging 24:223–226PubMedCrossRef
6.
Zurück zum Zitat Feuchtner GM, Muller S, Bonatti J et al (2007) Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area. AJR Am J Roentgenol 189:197–203PubMedCrossRef Feuchtner GM, Muller S, Bonatti J et al (2007) Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area. AJR Am J Roentgenol 189:197–203PubMedCrossRef
7.
Zurück zum Zitat Feuchtner GM, Dichtl W, Müller S et al (2008) 64-MDCT for diagnosis of aortic regurgitation in patients referred to CT coronary angiography. AJR Am J Roentgenol 191:W1–W7PubMedCrossRef Feuchtner GM, Dichtl W, Müller S et al (2008) 64-MDCT for diagnosis of aortic regurgitation in patients referred to CT coronary angiography. AJR Am J Roentgenol 191:W1–W7PubMedCrossRef
8.
Zurück zum Zitat Lee SC, Ko SM, Song MG, Shin JK, Chee HK, Hwang HK (2012) Morphological assessment of the aortic valve using coronary computed tomography angiography, cardiovascular magnetic resonance, and transthoracic echocardiography: comparison with intraoperative findings. Int J Cardiovasc Imaging 28:33–44 Lee SC, Ko SM, Song MG, Shin JK, Chee HK, Hwang HK (2012) Morphological assessment of the aortic valve using coronary computed tomography angiography, cardiovascular magnetic resonance, and transthoracic echocardiography: comparison with intraoperative findings. Int J Cardiovasc Imaging 28:33–44
9.
Zurück zum Zitat Joo I, Park EA, Kim KH et al (2012) MDCT differentiation between bicuspid and tricuspid aortic valves in patients with aortic valvular disease: correlation with surgical findings. Int J Cardiovasc Imaging 28:171–182PubMedCrossRef Joo I, Park EA, Kim KH et al (2012) MDCT differentiation between bicuspid and tricuspid aortic valves in patients with aortic valvular disease: correlation with surgical findings. Int J Cardiovasc Imaging 28:171–182PubMedCrossRef
10.
Zurück zum Zitat Tops LF, Wood DA, Delgado V et al (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implication for transcatheter aortic valve replacement. J Am Coll Img 1:321–330CrossRef Tops LF, Wood DA, Delgado V et al (2008) Noninvasive evaluation of the aortic root with multislice computed tomography implication for transcatheter aortic valve replacement. J Am Coll Img 1:321–330CrossRef
11.
Zurück zum Zitat Khoo C, Cheung C, Jue J (2013) Patterns of aortic dilatation in bicuspid aortic valve-associated aortopathy. J Am Soc Echocardiogr 26:600–605PubMedCrossRef Khoo C, Cheung C, Jue J (2013) Patterns of aortic dilatation in bicuspid aortic valve-associated aortopathy. J Am Soc Echocardiogr 26:600–605PubMedCrossRef
12.
Zurück zum Zitat Kang JW, Song HG, Yang DH et al (2013) Association between bicuspid aortic valve phenotype and patterns of valvular dysfunction and bicuspid aortopathy. J Am Coll Cardiol Img 6:150–161CrossRef Kang JW, Song HG, Yang DH et al (2013) Association between bicuspid aortic valve phenotype and patterns of valvular dysfunction and bicuspid aortopathy. J Am Coll Cardiol Img 6:150–161CrossRef
13.
Zurück zum Zitat Bonow RO, Carabello BA, Chatterjee K et al (2008) 2008 Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. Circulation 118:e523–e661PubMedCrossRef Bonow RO, Carabello BA, Chatterjee K et al (2008) 2008 Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. Circulation 118:e523–e661PubMedCrossRef
14.
Zurück zum Zitat Song MG, Yang HS, Choi JB et al (2014) Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation: early and midterm results. Ann Thorac Surg 97:1235–1241PubMedCrossRef Song MG, Yang HS, Choi JB et al (2014) Aortic valve reconstruction with leaflet replacement and sinotubular junction fixation: early and midterm results. Ann Thorac Surg 97:1235–1241PubMedCrossRef
15.
Zurück zum Zitat Sievers HH, Schmidtke C (2007) A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg 133:1226–1233PubMedCrossRef Sievers HH, Schmidtke C (2007) A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg 133:1226–1233PubMedCrossRef
16.
Zurück zum Zitat Russo CF, Cannata A, Lanfranconi M, Vitali E, Garatti A, Bonacina E (2008) Is aortic wall degeneration related to bicuspid aortic valve anatomy with valvular disease? J Thorac Cardiovasc Surg 136:937–942PubMedCrossRef Russo CF, Cannata A, Lanfranconi M, Vitali E, Garatti A, Bonacina E (2008) Is aortic wall degeneration related to bicuspid aortic valve anatomy with valvular disease? J Thorac Cardiovasc Surg 136:937–942PubMedCrossRef
17.
Zurück zum Zitat Buchner S, Hulsmann M, Poschenrieder F et al (2010) Variable phenotypes of bicuspid aortic valve disease: classification by cardiovascular magnetic resonance. Heart 96:1233–1240PubMedCrossRef Buchner S, Hulsmann M, Poschenrieder F et al (2010) Variable phenotypes of bicuspid aortic valve disease: classification by cardiovascular magnetic resonance. Heart 96:1233–1240PubMedCrossRef
18.
Zurück zum Zitat Schaefer BM, Lewin MB, Stout KK et al (2008) The bicuspid aortic valve: an integrated phenotypic classification of leaflet morphology and aortic root shape. Heart 94:1634–1638PubMedCrossRef Schaefer BM, Lewin MB, Stout KK et al (2008) The bicuspid aortic valve: an integrated phenotypic classification of leaflet morphology and aortic root shape. Heart 94:1634–1638PubMedCrossRef
19.
Zurück zum Zitat Kari FA, Fazel SS, Mitchell RS, Fischbein MP, Miller DC (2012) Bicuspid aortic valve configuration and aortopathy pattern might represent different pathophysiologic substrates. J Thorac Cardiovasc Surg 144:516–517PubMedCrossRef Kari FA, Fazel SS, Mitchell RS, Fischbein MP, Miller DC (2012) Bicuspid aortic valve configuration and aortopathy pattern might represent different pathophysiologic substrates. J Thorac Cardiovasc Surg 144:516–517PubMedCrossRef
20.
Zurück zum Zitat Cecconi M, Manfrin M, Moraca A et al (2005) Aortic dimensions in patients with bicuspid aortic valve without significant valve dysfunction. Am J Cardiol 95:292–294PubMedCrossRef Cecconi M, Manfrin M, Moraca A et al (2005) Aortic dimensions in patients with bicuspid aortic valve without significant valve dysfunction. Am J Cardiol 95:292–294PubMedCrossRef
21.
Zurück zum Zitat den Reijer PM, Sallee D 3rd, van der Velden P et al (2010) Hemodynamic predictors of aortic dilatation in bicuspid aortic valve by velocity-encoded cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:12–14 den Reijer PM, Sallee D 3rd, van der Velden P et al (2010) Hemodynamic predictors of aortic dilatation in bicuspid aortic valve by velocity-encoded cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:12–14
22.
Zurück zum Zitat Bauer M, Siniawski H, Pasic M, Schaumann B, Hetzer R (2006) Different hemodynamic stress of the ascending aorta wall in patients with bicuspid and tricuspid aortic valve. J Card Surg 21:218–220PubMedCrossRef Bauer M, Siniawski H, Pasic M, Schaumann B, Hetzer R (2006) Different hemodynamic stress of the ascending aorta wall in patients with bicuspid and tricuspid aortic valve. J Card Surg 21:218–220PubMedCrossRef
23.
Zurück zum Zitat Hope MD, Hope TA, Meadows AK et al (2010) Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns. Radiology 255:53–61PubMedCrossRef Hope MD, Hope TA, Meadows AK et al (2010) Bicuspid aortic valve: four-dimensional MR evaluation of ascending aortic systolic flow patterns. Radiology 255:53–61PubMedCrossRef
24.
Zurück zum Zitat Fedak PW, Verma S, David TE, Leask RL, Weisel RD, Butany J (2002) Clinical and pathophysiological implications of a bicuspid aortic valve. Circulation 106:900–904PubMedCrossRef Fedak PW, Verma S, David TE, Leask RL, Weisel RD, Butany J (2002) Clinical and pathophysiological implications of a bicuspid aortic valve. Circulation 106:900–904PubMedCrossRef
25.
Zurück zum Zitat Fedak PW, de Sa MP, Verma S et al (2003) Vascular matrix remodeling in patients with bicuspid aortic valve malformations: implications for aortic dilatation. J Thorac Cardiovasc Surg 126:797–806PubMedCrossRef Fedak PW, de Sa MP, Verma S et al (2003) Vascular matrix remodeling in patients with bicuspid aortic valve malformations: implications for aortic dilatation. J Thorac Cardiovasc Surg 126:797–806PubMedCrossRef
26.
Zurück zum Zitat Fernández B, Durán AC, Fernández-Gallego T et al (2009) Bicuspid aortic valves with different spatial orientations of the leaflets are distinct etiological entities. J Am Coll Cardiol 54:2312–2318PubMedCrossRef Fernández B, Durán AC, Fernández-Gallego T et al (2009) Bicuspid aortic valves with different spatial orientations of the leaflets are distinct etiological entities. J Am Coll Cardiol 54:2312–2318PubMedCrossRef
27.
Zurück zum Zitat Grube E, Laborde JC, Gerckens U et al (2006) Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study. Circulation 114:1616–1624PubMedCrossRef Grube E, Laborde JC, Gerckens U et al (2006) Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease: the Siegburg first-in-man study. Circulation 114:1616–1624PubMedCrossRef
28.
Zurück zum Zitat Webb JG, Chandavimol M, Thompson CR et al (2006) Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 113:842–850PubMedCrossRef Webb JG, Chandavimol M, Thompson CR et al (2006) Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 113:842–850PubMedCrossRef
29.
Zurück zum Zitat Layritz C, Schmid J, Achenbach S et al (2014) Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization. Eur Heart J Cardiovasc Imaging 15:1238–1245PubMedCrossRef Layritz C, Schmid J, Achenbach S et al (2014) Accuracy of prospectively ECG-triggered very low-dose coronary dual-source CT angiography using iterative reconstruction for the detection of coronary artery stenosis: comparison with invasive catheterization. Eur Heart J Cardiovasc Imaging 15:1238–1245PubMedCrossRef
Metadaten
Titel
Characteristics of aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve morphology
verfasst von
Hong Ju Shin
Je Kyoun Shin
Hyun Kun Chee
Jun Suk Kim
Sung Min Ko
Publikationsdatum
01.07.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 7/2015
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-014-3585-z

Weitere Artikel der Ausgabe 7/2015

European Radiology 7/2015 Zur Ausgabe

PET kann infarktgefährdete Koronararterien entdecken

04.06.2024 Koronare Herzerkrankung Nachrichten

Der Nachweis aktiver Plaques mittels 18F-Natriumfluorid-PET hilft nicht nur, infarktgefährdete Patienten, sondern auch infarktgefährdete Koronararterien zu erkennen. Von einer gezielten Behandlung vulnerabler Plaques ist man trotzdem weit entfernt.

Mammakarzinom: Brustdichte beeinflusst rezidivfreies Überleben

26.05.2024 Mammakarzinom Nachrichten

Frauen, die zum Zeitpunkt der Brustkrebsdiagnose eine hohe mammografische Brustdichte aufweisen, haben ein erhöhtes Risiko für ein baldiges Rezidiv, legen neue Daten nahe.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.