Skip to main content
Erschienen in: Langenbeck's Archives of Surgery 7/2016

Open Access 16.04.2016 | Systematic Reviews and Meta-analyses

Use of PET tracers for parathyroid localization: a systematic review and meta-analysis

verfasst von: Wouter P. Kluijfhout, Jesse D. Pasternak, Frederick Thurston Drake, Toni Beninato, Jessica E. Gosnell, Wen T. Shen, Quan-Yang Duh, Isabel E. Allen, Menno R. Vriens, Bart de Keizer, Miguel H. Pampaloni, Insoo Suh

Erschienen in: Langenbeck's Archives of Surgery | Ausgabe 7/2016

Abstract

Purpose

The great spatial and temporal resolution of positron emission tomography might provide the answer for patients with primary hyperparathyroidism (pHPT) and non-localized parathyroid glands. We performed a systematic review of the evidence regarding all investigated tracers.

Methods

A study was considered eligible when the following criteria were met: (1) adults ≥17 years old with non-familial pHPT, (2) evaluation of at least one PET isotope, and (3) post-surgical and pathological diagnosis as the gold standard. Performance was expressed in sensitivity and PPV.

Results

Twenty-four papers were included subdivided by radiopharmaceutical: 14 studies investigated l-[11C]Methionine (11C-MET), one [11C]2-hydroxy-N,N,N-trimethylethanamium (11C-CH), six 2-deoxy-2-[18F]fluoro-d-glucose (18F-FDG), one 6-[18F] fluoro-l-DOPA (18F-DOPA), and three N-[(18F)Fluoromethyl]-2-hydroxy-N,N-dimethylethanaminium (18F-FCH). The 14 studies investigating MET included a total of 327 patients with 364 lesions. Sensitivity for the detection of a lesion in the correct quadrant had a pooled estimate of 69 % (95 % CI 60–78 %). Heterogeneity was overall high with I2 of 51 % (p = 0.01) for all 14 studies. Pooled PPV ranged from 91 to 100 % with a pooled estimate of 98 % (95 % CI 96–100 %). Of the other investigated tracers, 18-FCH seems the most promising with high diagnostic performance.

Conclusions

The results of our meta-analysis show that 11C-MET PET has an overall good sensitivity and PPV and may be considered a reliable second-line imaging modality to enable minimally invasive parathyroidectomy. Our literature review suggests that 18F-FCH PET may produce even greater accuracy and should be further investigated using both low-dose CT and MRI for anatomical correlation.

Introduction

Primary hyperparathyroidism (pHPT) is the third most common endocrine disorder with a prevalence of around 4 per 1000. Incidence rises with age and is twice as common in women. Patients can present with a wide variety of well-described symptoms, ranging from nausea and fatigue to severe osteoporosis and cardiovascular complications [1]. Diagnosis is established biochemically, with the finding of relatively elevated serum calcium (Ca) level and concomitant inappropriately elevated parathyroid hormone (PTH) level. Most commonly, only one of the four glands is abnormal—typically an adenoma—and causes the condition (75–85 %). Less frequently, there are multiple adenomas (15–25 %) and very rarely a carcinoma (1 %) [2]. There is a universal agreement that all patients with symptoms, significant signs of disease (renal or bone manifestations), or young age (<50 years) should undergo surgical exploration [3]. Over the past decade, there has been a shift towards minimally invasive parathyroidectomy (MIP); a focused operation whereby only one parathyroid is removed. Compared to the conventional neck exploration, in which all four glands are investigated intra-operatively, MIP is associated with shorter operating time, lower complication rates, and smaller incision size [4, 5].
Imaging is critical in order to enable successful MIP. Aside from its ability to localize the pathological gland(s), accurate imaging provides valuable anatomical information for the surgeon. 99Tc-sestamibi single photon emission computed tomography (SPECT-CT) has become one of the mainstays in first-line parathyroid imaging based on robust evidence demonstrating its ability to predict the location of an adenoma [6]. However, a recent meta-analysis showed that its sensitivity is only 63–84 % (depending on protocol), which leaves a substantial amount of cases with equivocal imaging results [7]. For these cases, several second-line imaging modalities like MRI and CT are used, which have variable performance characteristics. Another modality that has been studied is positron emission tomography (PET). The greater spatial and temporal resolution of PET compared to SPECT imaging allows detection of even the smallest pathological glands, which in theory could improve sensitivity. One of the first reported uses of PET for parathyroid disease used 2-deoxy-2-[18F]fluoro-d-glucose (18F-FDG), which revealed the location of a pathological parathyroid gland in a patient with pHPT [8]. Over the years, several other tracers have been investigated as well, with variable results. The performance of PET depends mostly on the ability of the tracer to show specific uptake in the targeted organ. Although PET seems to be a promising new possibility for imaging of pathologic parathyroid glands, not all radiopharmaceuticals are suitable based on multiple factors, including tracer half-life, specificity to parathyroid uptake, and individual hospital characteristics. To our knowledge, there is no pre-existing literature that has reviewed all of the investigated PET tracers in patients with pHPT. Therefore, we performed a systematic review of the evidence available regarding all investigated tracers and also performed a meta-analysis of the data regarding the use of l-(11C)Methionine (11C-MET), the most extensively investigated tracer thus far.

Material and methods

We performed a search of the Embase, PubMed, and Cochrane Library databases published through March 18, 2016, to identify studies investigating the diagnostic value of all PET radiopharmaceuticals for parathyroid localization in patients with biochemical pHPT. We employed an extensive search filter by using all relevant synonyms and Mesh/Emtree terms (Table 1). We completed our search by performing a robust cross-reference check in Web of Science and manually searched references of selected articles, related reviews, and guidelines.
Table 1
Search strategy
Strategy component and step no.
Query
PubMed and Cochrane database
 Patient
  1
Hyperparathyroidism OR parathyroid OR HPT OR PHPT
  2
MeSH descriptor hyperparathyroidism explode all trees
 Intervention
  3
PET OR “Positron Emission Tomography”
  4
MeSH descriptor Tomography, Emission-Computed explode all trees
Embase
 Patient
  1
Hyperparathyroidism OR parathyroid OR HPT OR PHPT
  2
EMTREE hyperparathyroidism explosion
 Intervention
  3
PET OR “Positron Emission Tomography”
  4
EMTREE positron emission tomography explosion
 Merge
  5
1 OR 2
  6
3 OR 4
  7
5 AND 6

Inclusion and exclusion criteria

From the publications retrieved via our systematic search, we removed any duplicates (Fig. 1). All remaining unique publications were screened based on title and abstract for eligibility. A study was considered eligible when the following criteria were met: (1) adults ≥17 years old with biochemical non-familial pHPT, (2) evaluation of at least one PET tracer, and (3) post-surgical and pathological diagnosis as the gold standard. If an article presented data for multiple study groups, of which some were eligible for inclusion, the eligible study groups were included if their pertinent data could be extracted.
We excluded studies that differed in design (case reports, systematic reviews), domain (other than pHPT), and language (non-English). All titles and abstracts were screened independently by two authors (W.P.K. and J.D.P.). Any disagreements in selection were discussed, and after consensus, the selected papers were screened for full text review.
Studies were included in the systematic review if they investigated at least five patients, independent of the tracer. Studies were included in the meta-analysis if the following inclusion criteria were met: (1) use of the tracer 11C-MET, (2) extractable and unique data for the calculation of sensitivity and PPV for localization of pathological gland(s) to the correct quadrant (left lower, right lower, left upper, right upper, or ectopic), (3) histological examination of the resected parathyroid gland(s), and (4) a minimum of five included patients.

Quality assessment

To assess the quality of the included studies, we used the Quality Assessment of Studies of Diagnostic Accuracy Included in Systematic Reviews (QUADAS-)2 tool [9]. This tool is designed to assess the quality of primary diagnostic accuracy studies. It consists of 4 key domains that address (1) patient selection, (2) index test, (3) reference standard and (4) flow of patients through the study and timing of the index tests and reference standard. The domains are assessed for risk of bias and applicability. The two reviewers (W.P.K. and J.P.) used this tool to independently evaluate the methodological quality of the included studies. Disagreements were solved by discussion and thus the final report is based upon consensus of the two reviewers.

Data extraction

Data were extracted using a standardized spreadsheet. Study design characteristics included the tracer used, injected dose, possible combination with CT, study population, and number of included patients. Since pHPT is a biochemical diagnosis and all patients included were diagnosed with pHPT, there were no true negative scans and therefore specificity and NPV were not calculated. The performance of PET was expressed in sensitivity (total number of glands localized to the correct quadrant / total number of pathological glands found during surgery) and PPV (total number of glands localized to the correct quadrant / total number of glands suspicious for adenomas or hyperplasia). Data regarding MET was calculated using pooled proportion and displayed using forest plots. Sensitivity was defined as the probability that the localization study correctly identified the pathological gland(s). PPV was defined as the probability that a patient with a positive localization study had a pathological gland in that specific location. If data regarding sensitivity or PPV was missing in the selected paper, the author was contacted. Since sensitivity and PPV were calculated using the aforementioned criteria for patients with pHPT, the results may differ from the original papers.
For the studies investigating MET, random-effects models (REM) were used to pool the data [10]. The REM model was fit to account for study heterogeneity. The heterogeneity among studies was tested using the I2 statistic test with a p value of less than 0.1 for statistical significance [11]. The I2 statistic is expressed in a percentage scale in which 0 % implies study homogeneity and 100 % indicates that between-study variance is much larger than within study variance. The investigated study population could have influenced the diagnostic performance, thereby causing heterogeneity, and was therefore investigated by subgroup-analysis. The studies were subdivided into 3 groups consisting of patients (1) without specific selection, (2) with negative or discordant conventional imaging, and (3) with a history of previous parathyroid surgery. Funnel plots were used as a visual tool for investigating heterogeneity and publication bias [12]. These plots are scatterplots of the treatment effects estimated from individual studies against a measure of study size. In the absence of publication bias, the funnel plots are symmetrical.
Data analysis was performed using StataSE 13 and conducted by a biostatistician specializing in meta-analysis (I.A.). For this type of study, no formal consent is required.

Results

The literature search yielded a total of 1174 unique papers, of which 41 papers remained eligible after screening of title and abstract for relevance. After full text review, 24 papers were included. These were subdivided by radiopharmaceutical: 14 studies investigated 11C-MET, one [11C]2-hydroxy-N,N,N-trimethylethanamium (11C-CH), six 18F-FDG, one 6-[18F] fluoro-l-DOPA (18F-DOPA), and three N-[(18F)Fluoromethyl]-2-hydroxy-N,N-dimethylethanaminium (18F-FCH) [1336]. Excluded were studies that had fewer than five patients, abstracts from conferences without available full text, and redundant studies investigating the same population. The process of study selection is illustrated in Fig. 1. The 14 studies investigating MET underwent meta-analysis, which included a total of 327 patients with 364 lesions.

Characteristics of the MET studies

All studies were single-center and included between eight and 29 patients, with the exception of the study by Weber et al., which included 102 patients. Four studies had a prospective design, whereas the rest were conducted retrospectively. Most studies also involved patients with secondary (sHPT) or tertiary HPT, or patients that did not proceed to surgery (our gold standard). These patients were excluded from the analysis. Patients with negative or discordant conventional imaging were included in three studies, and two other studies specifically included patients with previous neck surgery. The injected dose of radioactive tracer varied between 370 and 1100 MBq (10–30 mCi) and scanning started between 0 and 40 min after injection with an additional low-dose CT in ten studies. The characteristics are listed in Table 2.
Table 2
Characteristics of included studies investigating 11C-Methionine
Study
First author
Year
No. of patients
Study population
Dose (MBq)
CT
Time (min)
Total
pHPT + surgery
Braeuning
2015
18
12
Neg/disc imaging
600
yes
20
Hayakawa
2015
23
15
Mixed
441–906
yes
15–34
Chicklore
2014
43
15
Mixed
740
yes
10
Martinez
2014
14
14
Mixed
740
yes
10 and 40
Weber
2013
102
102
Mixed
?
yes
20
Chun
2013
16
8
Neg/disc imaging
370–444
yes
30–40
Schalin
2012
21
21
Previous surgery
440
yes
20
Oksuz
2011
8
8
Mixed
700
4/4
15
Weber
2010
33
33
Mixed
?
yes
20
Herrmann
2009
41
9
Mixed
430
no
15–20
Tang
2008
30
22
Mixed
555
yes
20
Beggs
2005
51
29
Neg/disc imaging
619
no
15
Otto
2004
30
14
Mixed
900–1100
no
10
Sundin
1996
34
25
Previous surgerya
750
no
direct
pHPT primary hyperparathyroidism, Neg negative, Disc discordant
aPrevious surgery in 25/34 patients included in the study

Quality assessment of the MET studies

Quality assessment is displayed in Fig. 2 using the QUADAS 2 tool for risk of bias and applicability. Overall, there was a particularly high risk of bias arising from lack of a reference standard and heterogeneity in patient selection. Bias related to the reference standard relates to the fact that a clear definition of cure was lacking in several of the studies. The reference standard varied between no mention of follow-up data to documentation of normocalcemia at 6 months, which is the widely excepted definition of cure. Since estimates of accuracy are based on the assumption that the reference standard is 100 % sensitive and specific, the lack of a clear reference standard might have resulted in misinterpretation of the accuracy of the index test. Substantial risk of bias was present since most studies did not enroll consecutive patients or a random sample of eligible patients. Moreover, as can be seen in Table 2, only a proportion of patients included in the studies underwent surgery. (Because of this, some studies were excluded from the meta-analysis, since they only performed surgery on patients with a positive scan, potentially overestimating its performance.) Concerns regarding applicability were low for the index test, as the scans were usually conducted according to a specific protocol within the studies. However, there was great variability between studies with regard to the PET protocol in terms of tracer dose, use of additional CT, and timing of the scan, which raises concerns as to the applicability of the index test. Patient selection also raises applicability concerns, since the study populations of patients were variable and could not entirely be adjusted for via sub-analysis.
Publication bias was investigated using a funnel plot. The distribution indicates a publication bias of small and most likely irrelevant studies (Fig. 3).

Accuracy and heterogeneity of the MET studies

Individual and summary estimates of per-quadrant sensitivity and PPV are shown in Fig. 4a and b. Sensitivity for the detection of a lesion in the correct quadrant ranged from 44 to 91 %, with a pooled estimate of 77 % (95 % CI 71–84 %). Subgroup-analysis based on selection of included patients was performed as well. A total of 9 studies did not specifically select patients (group 1) and showed a random pooled sensitivity of 78 % (95 % CI 70–86 %), which was almost the same as for the three studies that included patients with negative or inconclusive conventional imaging (group 2) and had a pooled sensitivity of 81 % (95 % CI 70–91 %). The two studies that predominantly investigated patients with previous parathyroid surgery had discrepant outcomes with sensitivities of 54 and 84 %. Heterogeneity was overall high with I2 of 51 % (p = 0.01) for all 14 studies and moderate between the 2 subgroups (I2 = 42 %; p = 0.06) (Fig. 4a and b). Pooled PPV ranged from 91 to 100 % with a pooled estimate of 98 % (95 % CI 96–100 %) (Fig. 5).

Other investigated PET tracers

Details about studies investigating other PET tracers are listed in Table 3. From six studies investigating FDG, three were from the same author; however, the domain differed. Two of these included only patients without previous parathyroidectomy—consisting of 17 and 21 patients with pHPT—and excluded patients with hyperplasia from the results [33, 36]. These studies found sensitivities of 94 and 86 % and PPVs of 85 and 86 %, respectively. The third included 20 patients with a history of neck surgery and found a much lower sensitivity and PPV, both 62 % [32]. The three other studies found even lower sensitivities, varying between 0 and 27 %, although PPVs were consistently high. Notably, none of the 8 scans performed by Sisson et al. showed a focus that could be attributed to a parathyroid adenoma [35].
Table 3
Characteristics of studies investigating PET tracers other than 11C-Methionine
Study
First author
Tracer
Year
No. of patients
Dose (MBq)
CT
Time (min)
Sens (%)
PPV (%)
Total
pHPT + surgery
Kluijfhout
18F-FCH
2015
5
5
2 MBq/kg
yes
direct
80
100
Michaud
18F-FCH
2015
17
11
3 MBq/kg
yes
direct
94
91
Lezaic
18F-FCH
2015
43
43
100
yes
5,60,120
95
97
Orevi
11C-CH
2014
40
?
370
yes
direct
?
?
Lange-Nolde
18F-DOPA
2006
8
8
185–300
no
90
Chicklore
18F-FDG
2014
43
15
400
yes
90
27
100
Neumann
18F-FDG
1997
20
20
185–370
no
45
62
62
Neumann
18F-FDG
1996
21
21
185–370
no
45
86
86
Melon
18F-FDG
1995
7
7
370
no
50
22
100
Sisson
18F-FDG
1994
8
8
370
no
?
0
Neumann
18F-FDG
1994
17
17
185–370
no
45
94
85
pHPT primary hyperparathyroidism, Sens sensitivity, PPV positive predictive value
Five recent studies published results regarding 18F-FCH; however, Michaud et al. and Lezaic et al. published two articles using the same population [28, 29, 37, 38]. The most recent study of Michaud et al. included 17 patients without prior neck surgery, divided in 11 patients with pHPT, five with sHPT, and one lithium-associated [28]. All patients had 18F-FCH PET-CT because of negative/discordant ultrasound and 123I/99mTc-sestamibi subtraction scintigraphy. Sensitivity per lesion was up to 94 %. The most recent study of Lezaic et al. included 43 patients with pHPT and no previous neck surgery [29]. All patients underwent ultrasound, 99mTc-sestamibi/pertechnetaat subtraction scintigraphy, SPECT-CT, and 18F-FCH PET-CT. Sensitivity per lesion of PET-CT was up to 95 %. Kluijfhout et al. conducted 5 scans in patients with negative conventional imaging and found a sensitivity of 80 % with a PPV of 100 % [27].
Lange-Nolde et al. investigated the performance of 18F-DOPA [31]. They included eight patients with pHPT. All had histologically proven adenomas; however, none of the scans showed any detectable uptake.
Orevi et al. published preliminary results of 11C-CH PET-CT [30]. They included 40 patients with HPT, of which 20 were diagnosed with pHPT and the latter predominantly with sHPT. In 24 of 27 patients that underwent surgery so far, there was concordance between PET result and surgical findings. There was insufficient data to calculate specific performance for patients with pHPT; however, the scan was clearly positive in 37 out of 40 patients.

Discussion

We performed a meta-analysis to investigate the performance of 11C-MET PET to localize pathological parathyroid gland(s) in patients with pHPT. Our results show a pooled sensitivity and PPV for the detection of a pathological parathyroid in the correct quadrant of 77 and 98 %, respectively. In subgroup-analysis, we found no difference in sensitivity in patients without specific selection versus patients with negative/discordant conventional imaging (78 versus 81 %, respectively). Among the other investigated tracers in our systematic review, 18F-FCH seems the most promising with sensitivity ranging from 80–100 % and PPV 89–100 % in three studies with a total of 37 patients.
Our pooled sensitivity of 77 % is slightly lower than the pooled sensitivity of 81 % found by Caldarella et al. who published a meta-analysis regarding 11C-MET PET in 2012 [39]. Since then, new evidence has been published and there are several major methodological differences between that study and the current meta-analysis. First, Caldarella et al. did not solely include patients with pHPT but also with sHPT. Second, their calculations are based on a per-patient level: as most surgeons favor MIP to bilateral neck exploration, a per-lesion sensitivity for localization to the correct quadrant may be more clinically relevant. Identification of the right quadrant per lesion is more precise, which might explain our slightly lower pooled sensitivity. Lastly, PPV is not calculated; instead, the authors presented a detection rate, defined as percentage of positive scans, without correlating this to the surgical outcome. In an attempt to examine a more homogenous group, we included only patients with pHPT. The domain of the included patients did however still vary greatly, which is why subgroup-analysis was performed to examine whether patient domain influenced the accuracy of 11C-MET PET.
In subgroup-analysis, performance of 11C-MET PET in a mixed patient cohort (group 1; pooled sensitivity 78 %) was comparable to conventional 99mTC-sestamibi SPECT (sensitivity 79 %), but substantially lower compared to sestamibi SPECT/CT (sensitivity of 88 %) [40, 41]. Remarkably, the performance of 11C-MET PET did not decline significantly when only patients with negative or inconclusive imaging were included (group 2, pooled sensitivity 81 %). This suggests that 11C-MET PET is relatively most useful in a substantial amount of cases with negative/discordant conventional imaging and could therefore be considered as a suitable second-line imaging modality.
The ability of 11C-MET PET to detect hyperplastic glands was lower compared to patients with adenomas. In the largest study included in our meta-analysis, overall sensitivity was 83 %, versus 33 % for hyperplastic glands [17]. Hyperplastic glands are often smaller in size and weigh less than adenomas, both factors that have previously been associated with decreased sensitivity [14]. This might also be a contributing reason as to why performance is lower in patients with persistent pHPT after previous parathyroid surgery. Schalin et al. included 21 patients with pHPT and persistent disease and found a sensitivity of 44 %, substantially lower than the pooled sensitivity of 77 % found in this study [19]. Weber et al. also performed a subgroup-analysis on patients with previous neck surgery, including patients after thyroid surgery. Remarkably the sensitivity in this group was higher compared to the total group (94 versus 83 %). Thyroid tissue reduces the lesion-to-background ratio due to physiological thyroidal uptake of 11C-MET and thereby complicates reading of parathyroid scans [22]. Pathological parathyroids that are in a juxtathyroidal location can therefore cause false negative outcomes [26].
Detection of accumulated 11C-MET can be done at different times after injection, and protocols varied in this study from scanning immediately after injection to scanning 40 min post-injection. Two studies had protocols in which patients were scanned twice at 10 and 40 min to compare the effect of timing on diagnostic efficacy [16, 25]. They found the best parathyroid to background contrast and the best delineation of hyper-functioning parathyroid after 10 min, although the best parathyroid to thyroid contrast was seen after 40 min. Martinez et al. included the late scan when the 10-min scan was negative, which resulted in the detection of one additional positive parathyroid gland in their study. Scans later than 40 min resulted in insufficient count statistics owing to the short half-life of 11C-MET (20 min). The short half-life of 11C-MET and the complicating labeling procedure is also one of the biggest limitations of MET. It requires the center to have a cyclotron for production of the tracer since transportation from another facility would take too much time.
Recent publications often used a combination of PET and CT. Contrast enhancement CT can be useful to differentiate with lymph nodes and might therefore prevent false positive outcomes [42]. However, there is also increasing attention to the possible risks of extra radiation involved with CT [43]. Several studies also investigated other factors that may affect the accuracy, such as goiter, thyroiditis, and parathyroid hormone level; however, a separate analysis could not be performed due to insufficient available data. Nevertheless, in general PET appears to work well even in these settings [17, 26].
The second best investigated tracer is 18F-FDG, which has the advantage of a significant longer half-time of 110 min, enabling off-site production. Also, it is by far the most commonly used PET radiopharmaceutical and has wide availability. These benefits notwithstanding performance varied greatly between the six studies that have investigated its use with a sensitivity of 0–94 % and PPV of 62–100 %. Due to these highly discrepant findings, FDG appears to be a less useful tracer for the detection of pathological parathyroids. 18F-DOPA, in a limited trial, performed even more poorly. Using a prospective study design, Lange-Nolde et al. scanned eight patients with pHPT, each of whom had adenomas detected in the operating room; however, none of the 18F-DOPA PET scans were positive [31]. More promising seems to be the use of 11C-CH. A recent prospective study by Orevi et al. included 40 patients with HPT, and there were 37 choline positive scans [30]. Although their results are preliminary and only some of the patients have undergone surgery, these data suggest that 11C-CH may be an important tracer in radiographic localization of parathyroid adenomas. The main disadvantage (similar to 11C-MET) is the short half-life of 20 min, which obligates on-site production. This problem has been overcome by the most promising PET tracer thus far, 18F-FCH, which has a half-life of 110 min. This tracer is frequently used in the diagnostic work-up and follow-up of patients with prostate cancer and has, therefore, wide availability. So far, three studies have published unique data with excellent preliminary results, even in patients with negative SPECT-CT [2729]. The advantage of 18F-FCH PET-CT over SPECT-CT is the higher spatial resolution, lower radiation burden (around 6 versus 8 mSv), and the substantially shorter scanning time with a single acquisition of around 10 min, depending on protocol [44].
Besides PET, several other modalities have been studied for use as a second-line imaging as well. Computed tomography is available in virtually every medical center and has been shown to accurately detect parathyroid adenomas, even in the case of negative conventional imaging [45, 46]. There is increasing attention to 4D-CT, which can help clinicians differentiate adenomas from other structures in the neck [47]. Performance has shown to be good, with a sensitivity and PPV of around 80 and 90 %, respectively, depending on the investigated population [48, 49]. The major drawback of this technique, which uses multiple phases, is radiation exposure that can be as high as 26 mSv from a single scan [50]. MRI can also be used to localize parathyroid glands. Evidence remains scarce, but one of the largest studies so far showed a sensitivity of 82 % with a PPV of 89 % and a very recent publication also showed promising results [51, 52]. Considering the unique benefits of 18F-FCH PET and MRI, a potentially superior modality would be using the 18F-FCH tracer and a combined PET MRI scanner. Although no studies have been published yet, preliminary results from a pilot-study show excellent results in patients with negative or discordant conventional imaging [Unpublished results Kluijfhout et al.].
Our meta-analysis has several limitations. Like any meta-analysis, its quality is limited by the number and quality of constituent studies. Each individual study included only a small number of patients. As shown by the QUADAS 2 tool, there was also a substantial risk of bias arising from variability in patient selection and reference standard. Moreover, there is concern regarding applicability as various imaging protocols were used. The results of this meta-analysis should therefore be interpreted with caution, and more research, especially in the form of prospective studies, is needed to confirm our observations.

Conclusion

To our knowledge, this is the first systematic review investigating all PET tracers that have been used for the detection of pathological parathyroid glands. The results of our meta-analysis show that 11C-MET PET has an overall good sensitivity and PPV and may be considered a reliable second-line imaging modality to enable minimally invasive parathyroidectomy. Our literature review suggests that 18F-FCH PET may produce even greater accuracy and should be further investigated using both low-dose CT and MRI for anatomical correlation.

Author contributions

All of the authors contributed to the study conception and design and the critical revision of the manuscript.
Wouter P Kluijfhout and Jesse D Pasternak contributed to the acquisition of data.
Wouter P Kluijfhout, Jesse D Pasternak, Frederick T Drake, and Isabel E Allen contributed to the analysis and interpretation of data.
Wouter P Kluijfhout, Jesse D Pasternak, Frederick T Drake, Bart de Keizer, Miguel H Pampaloni, and Insoo Suh contributed to the drafting of the manuscript.

Compliance with ethical standards

No funding was received for this work.
This article does not contain any studies with human participants or animals performed by any of the authors.

Conflicts of interest

The authors declare that they have no conflict of interest.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

e.Med Interdisziplinär

Kombi-Abonnement

Jetzt e.Med zum Sonderpreis bestellen!

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Jetzt bestellen und 100 € sparen!

Literatur
2.
Zurück zum Zitat Phitayakorn R, McHenry CR (2006) Incidence and location of ectopic abnormal parathyroid glands. Am J Surg 191:418–423CrossRefPubMed Phitayakorn R, McHenry CR (2006) Incidence and location of ectopic abnormal parathyroid glands. Am J Surg 191:418–423CrossRefPubMed
3.
Zurück zum Zitat Udelsman R, Akerstrom G, Biagini C et al (2014) The surgical management of asymptomatic primary hyperparathyroidism: proceedings of the Fourth International Workshop. J Clin Endocrinol Metab 99:3595–3606CrossRefPubMed Udelsman R, Akerstrom G, Biagini C et al (2014) The surgical management of asymptomatic primary hyperparathyroidism: proceedings of the Fourth International Workshop. J Clin Endocrinol Metab 99:3595–3606CrossRefPubMed
4.
Zurück zum Zitat Sackett WR, Barraclough B, Reeve TS, Delbridge LW (2002) Worldwide trends in the surgical treatment of primary hyperparathyroidism in the era of minimally invasive parathyroidectomy. Arch Surg 137:1055–1059CrossRefPubMed Sackett WR, Barraclough B, Reeve TS, Delbridge LW (2002) Worldwide trends in the surgical treatment of primary hyperparathyroidism in the era of minimally invasive parathyroidectomy. Arch Surg 137:1055–1059CrossRefPubMed
5.
Zurück zum Zitat Irvin GL, Carneiro DM, Solorzano CC (2004) Progress in the operative management of sporadic primary hyperparathyroidism over 34 years. Ann Surg 239:704–708, discussion 708–711CrossRefPubMedPubMedCentral Irvin GL, Carneiro DM, Solorzano CC (2004) Progress in the operative management of sporadic primary hyperparathyroidism over 34 years. Ann Surg 239:704–708, discussion 708–711CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Prommegger R, Wimmer G, Profanter C et al (2009) Virtual neck exploration: a new method for localizing abnormal parathyroid glands. Ann Surg 250:761–765CrossRefPubMed Prommegger R, Wimmer G, Profanter C et al (2009) Virtual neck exploration: a new method for localizing abnormal parathyroid glands. Ann Surg 250:761–765CrossRefPubMed
7.
Zurück zum Zitat Wei WJ, Shen CT, Song HJ et al (2015) Comparison of SPET/CT, SPET and planar imaging using 99mTc-MIBI as independent techniques to support minimally invasive parathyroidectomy in primary hyperparathyroidism: a meta-analysis. Hell J Nucl Med 18:127–135PubMed Wei WJ, Shen CT, Song HJ et al (2015) Comparison of SPET/CT, SPET and planar imaging using 99mTc-MIBI as independent techniques to support minimally invasive parathyroidectomy in primary hyperparathyroidism: a meta-analysis. Hell J Nucl Med 18:127–135PubMed
8.
Zurück zum Zitat Neumann DR, Esselstyn CB, MacIntyre WJ et al (1993) Parathyroid adenoma localization by PET FDG. J Comput Assist Tomogr 17:976–977CrossRefPubMed Neumann DR, Esselstyn CB, MacIntyre WJ et al (1993) Parathyroid adenoma localization by PET FDG. J Comput Assist Tomogr 17:976–977CrossRefPubMed
9.
Zurück zum Zitat Whiting PF, Rutjes AWS, Westwood ME et al (2011) Research and reporting methods accuracy studies. Ann Intern Med 155:529–536CrossRefPubMed Whiting PF, Rutjes AWS, Westwood ME et al (2011) Research and reporting methods accuracy studies. Ann Intern Med 155:529–536CrossRefPubMed
10.
Zurück zum Zitat DerSimonian R, Laird N (1986) Meta-analysis in clinical trials. Control Clin Trials 7:177–188CrossRefPubMed DerSimonian R, Laird N (1986) Meta-analysis in clinical trials. Control Clin Trials 7:177–188CrossRefPubMed
11.
Zurück zum Zitat Higgins JPT, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ Br Med J 327:557–560CrossRef Higgins JPT, Thompson SG, Deeks JJ, Altman DG (2003) Measuring inconsistency in meta-analyses. BMJ Br Med J 327:557–560CrossRef
12.
Zurück zum Zitat Sterne JA, Sutton AJ, Ioannidis JP et al (2011) Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ 343:d4002CrossRefPubMed Sterne JA, Sutton AJ, Ioannidis JP et al (2011) Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. BMJ 343:d4002CrossRefPubMed
13.
Zurück zum Zitat Braeuning U, Pfannenberg C, Gallwitz B et al (2015) 11C-methionine PET/CT after in conclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism. NuklearMedizin 54:26–30CrossRefPubMed Braeuning U, Pfannenberg C, Gallwitz B et al (2015) 11C-methionine PET/CT after in conclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism. NuklearMedizin 54:26–30CrossRefPubMed
14.
Zurück zum Zitat Hayakawa N, Nakamoto Y, Kurihara K et al (2015) A comparison between 11C-methionine PET/CT and MIBI SPECT/CT for localization of parathyroid adenomas/hyperplasia. Nucl Med Commun 36:53–59CrossRefPubMed Hayakawa N, Nakamoto Y, Kurihara K et al (2015) A comparison between 11C-methionine PET/CT and MIBI SPECT/CT for localization of parathyroid adenomas/hyperplasia. Nucl Med Commun 36:53–59CrossRefPubMed
15.
Zurück zum Zitat Chicklore S, Schulte KM, Talat N, Hubbard JG, O’Doherty M, Cook GJ (2014) 18F-FDG PET rarely provides additional information to 11C-methionine PET imaging in hyperparathyroidism. Clin Nucl Med 39:237–242CrossRefPubMed Chicklore S, Schulte KM, Talat N, Hubbard JG, O’Doherty M, Cook GJ (2014) 18F-FDG PET rarely provides additional information to 11C-methionine PET imaging in hyperparathyroidism. Clin Nucl Med 39:237–242CrossRefPubMed
16.
Zurück zum Zitat Martinez-Rodriguez I, Martinez-Amador N, de Arcocha-Torres M et al (2014) Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism. Rev Esp Med Nucl Imagen Mol 33:93–98PubMed Martinez-Rodriguez I, Martinez-Amador N, de Arcocha-Torres M et al (2014) Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism. Rev Esp Med Nucl Imagen Mol 33:93–98PubMed
17.
Zurück zum Zitat Weber T, Maier-Funk C, Ohlhauser D et al (2013) Accurate preoperative localization of parathyroid adenomas with C-11 methionine PET/CT. Ann Surg 257:1124–1128CrossRefPubMed Weber T, Maier-Funk C, Ohlhauser D et al (2013) Accurate preoperative localization of parathyroid adenomas with C-11 methionine PET/CT. Ann Surg 257:1124–1128CrossRefPubMed
18.
Zurück zum Zitat Chun IK, Cheon GJ, Paeng JC, Kang KW, Chung JK, Lee DS (2013) Detection and characterization of parathyroid adenoma/hyperplasia for preoperative localization: comparison between 11C-Methionine PET/CT and 99mTc-sestamibi scintigraphy. Nucl Med Mol Imaging 47:166–172CrossRefPubMedPubMedCentral Chun IK, Cheon GJ, Paeng JC, Kang KW, Chung JK, Lee DS (2013) Detection and characterization of parathyroid adenoma/hyperplasia for preoperative localization: comparison between 11C-Methionine PET/CT and 99mTc-sestamibi scintigraphy. Nucl Med Mol Imaging 47:166–172CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Schalin-Jantti C, Ryhanen E, Heiskanen I et al (2013) Planar scintigraphy with 123I/99mTc-sestamibi, 99mTc-sestamibi SPECT/CT, 11C-methionine PET/CT, or selective venous sampling before reoperation of primary hyperparathyroidism? J Nucl Med 54:739–747CrossRefPubMed Schalin-Jantti C, Ryhanen E, Heiskanen I et al (2013) Planar scintigraphy with 123I/99mTc-sestamibi, 99mTc-sestamibi SPECT/CT, 11C-methionine PET/CT, or selective venous sampling before reoperation of primary hyperparathyroidism? J Nucl Med 54:739–747CrossRefPubMed
20.
Zurück zum Zitat Oksuz MO, Dittmann H, Wicke C et al (2011) Accuracy of parathyroid imaging: a comparison of planar scintigraphy, SPECT, SPECT-CT, and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia. Diagn Interv Radiol 17:297–307PubMed Oksuz MO, Dittmann H, Wicke C et al (2011) Accuracy of parathyroid imaging: a comparison of planar scintigraphy, SPECT, SPECT-CT, and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia. Diagn Interv Radiol 17:297–307PubMed
21.
Zurück zum Zitat Weber T, Cammerer G, Schick C et al (2010) C-11 methionine positron emission tomography/computed tomography localizes parathyroid adenomas in primary hyperparathyroidism. Horm Metab Res 42:209–214CrossRefPubMed Weber T, Cammerer G, Schick C et al (2010) C-11 methionine positron emission tomography/computed tomography localizes parathyroid adenomas in primary hyperparathyroidism. Horm Metab Res 42:209–214CrossRefPubMed
22.
Zurück zum Zitat Herrmann K, Takei T, Kanegae K et al (2009) Clinical value and limitations of [11C]-methionine PET for detection and localization of suspected parathyroid adenomas. Mol Imaging Biol 11:356–363CrossRefPubMed Herrmann K, Takei T, Kanegae K et al (2009) Clinical value and limitations of [11C]-methionine PET for detection and localization of suspected parathyroid adenomas. Mol Imaging Biol 11:356–363CrossRefPubMed
23.
Zurück zum Zitat Tang BNT, Moreno-Reyes R, Blocklet D et al (2008) Accurate pre-operative localization of pathological parathyroid glands using 11C-methionine PET/CT. Contrast Media Mol Imaging 3:157–163CrossRefPubMed Tang BNT, Moreno-Reyes R, Blocklet D et al (2008) Accurate pre-operative localization of pathological parathyroid glands using 11C-methionine PET/CT. Contrast Media Mol Imaging 3:157–163CrossRefPubMed
24.
Zurück zum Zitat Beggs AD, Hain SF (2005) Localization of parathyroid adenomas using 11C-methionine positron emission tomography. Nucl Med Commun 26:133–136CrossRefPubMed Beggs AD, Hain SF (2005) Localization of parathyroid adenomas using 11C-methionine positron emission tomography. Nucl Med Commun 26:133–136CrossRefPubMed
25.
Zurück zum Zitat Otto D, Boerner AR, Hofmann M et al (2004) Pre-operative localisation of hyperfunctional parathyroid tissue with 11C-methionine PET. Eur J Nucl Med Mol Imaging 31:1405–1412CrossRefPubMed Otto D, Boerner AR, Hofmann M et al (2004) Pre-operative localisation of hyperfunctional parathyroid tissue with 11C-methionine PET. Eur J Nucl Med Mol Imaging 31:1405–1412CrossRefPubMed
26.
Zurück zum Zitat Sundin A, Johansson C, Hellman P et al (1996) Pet and parathyroid L-[carbon-11]methionine accumulation in hyperparathyroidism. J Nucl Med 37:1766–1770PubMed Sundin A, Johansson C, Hellman P et al (1996) Pet and parathyroid L-[carbon-11]methionine accumulation in hyperparathyroidism. J Nucl Med 37:1766–1770PubMed
27.
Zurück zum Zitat Kluijfhout WP, Vorselaars WMCM, Vriens MR et al (2015) Enabling minimal invasive parathyroidectomy for patients with primary hyperparathyroidism using Tc-99m-sestamibi SPECT–CT, ultrasound and first results of 18F-fluorocholine PET–CT. Eur J Radiol 84:1745–1751CrossRefPubMed Kluijfhout WP, Vorselaars WMCM, Vriens MR et al (2015) Enabling minimal invasive parathyroidectomy for patients with primary hyperparathyroidism using Tc-99m-sestamibi SPECT–CT, ultrasound and first results of 18F-fluorocholine PET–CT. Eur J Radiol 84:1745–1751CrossRefPubMed
28.
Zurück zum Zitat Michaud L, Balogova S, Burgess A et al (2015) A pilot comparison of 18F-fluorocholine PET/CT, ultrasonography and 123I/99mTc-sestaMIBI dual-phase dual-isotope scintigraphy in the preoperative localization of hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism: influence of thyroid anomalies. Medicine (Baltimore) 94, e1701CrossRef Michaud L, Balogova S, Burgess A et al (2015) A pilot comparison of 18F-fluorocholine PET/CT, ultrasonography and 123I/99mTc-sestaMIBI dual-phase dual-isotope scintigraphy in the preoperative localization of hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism: influence of thyroid anomalies. Medicine (Baltimore) 94, e1701CrossRef
29.
Zurück zum Zitat Rep S, Lezaic L, Kocjan T et al (2015) Optimal scan time for evaluation of parathyroid adenoma with [18F]-fluorocholine PET/CT. Radiol Oncol 49:327–333CrossRefPubMedPubMedCentral Rep S, Lezaic L, Kocjan T et al (2015) Optimal scan time for evaluation of parathyroid adenoma with [18F]-fluorocholine PET/CT. Radiol Oncol 49:327–333CrossRefPubMedPubMedCentral
30.
Zurück zum Zitat Orevi M, Freedman N, Mishani E, Bocher M, Jacobson O, Krausz Y (2014) Localization of parathyroid adenoma by 11C-Choline PET/CT: preliminary results. Clin Nucl Med 39:1033–1038CrossRefPubMed Orevi M, Freedman N, Mishani E, Bocher M, Jacobson O, Krausz Y (2014) Localization of parathyroid adenoma by 11C-Choline PET/CT: preliminary results. Clin Nucl Med 39:1033–1038CrossRefPubMed
31.
Zurück zum Zitat Lange-Nolde A, Zajic T, Slawik M et al (2006) PET with 18F-DOPA in the imaging of parathyroid adenoma in patients with primary hyperparathyroidism: a pilot study. NuklearMedizin 45:193–196PubMed Lange-Nolde A, Zajic T, Slawik M et al (2006) PET with 18F-DOPA in the imaging of parathyroid adenoma in patients with primary hyperparathyroidism: a pilot study. NuklearMedizin 45:193–196PubMed
32.
Zurück zum Zitat Neumann DR, Esselstyn CBJ, MacIntyre WJ et al (1997) Regional body FDG-PET in postoperative recurrent hyperparathyroidism. J Comput Assist Tomogr 21:25–28CrossRefPubMed Neumann DR, Esselstyn CBJ, MacIntyre WJ et al (1997) Regional body FDG-PET in postoperative recurrent hyperparathyroidism. J Comput Assist Tomogr 21:25–28CrossRefPubMed
33.
Zurück zum Zitat Neumann DR, Esselsteyn CB, MacIntyre WJ et al (1996) Comparison of FDG-PET and sestamibi-SPECT in primary hyperparathyroidism. J Nucl Med 37:1809–1815PubMed Neumann DR, Esselsteyn CB, MacIntyre WJ et al (1996) Comparison of FDG-PET and sestamibi-SPECT in primary hyperparathyroidism. J Nucl Med 37:1809–1815PubMed
34.
Zurück zum Zitat Melon P, Luxen A, Hamoir E et al (1995) Fluorine-18-fluorobeoxyglucose positron emission tomography for preoperative parathyroid imaging in primary hyperparathyroidism. Eur J Nucl Med 22:556–558CrossRefPubMed Melon P, Luxen A, Hamoir E et al (1995) Fluorine-18-fluorobeoxyglucose positron emission tomography for preoperative parathyroid imaging in primary hyperparathyroidism. Eur J Nucl Med 22:556–558CrossRefPubMed
35.
Zurück zum Zitat Sisson JC, Thompson NW, Ackerman RJ et al (1994) Use of 2-[F-18]-fluoro-2-deoxy-D-glucose PET to locate parathyroid adenomas in primary hyperparathyroidism. Radiology 192:280CrossRefPubMed Sisson JC, Thompson NW, Ackerman RJ et al (1994) Use of 2-[F-18]-fluoro-2-deoxy-D-glucose PET to locate parathyroid adenomas in primary hyperparathyroidism. Radiology 192:280CrossRefPubMed
36.
Zurück zum Zitat Neumann DR, Esselstyn CBJ, MacIntyre WJ et al (1994) Primary hyperparathyroidism: preoperative parathyroid imaging with regional body FDG PET. Radiology 192:509–512CrossRefPubMed Neumann DR, Esselstyn CBJ, MacIntyre WJ et al (1994) Primary hyperparathyroidism: preoperative parathyroid imaging with regional body FDG PET. Radiology 192:509–512CrossRefPubMed
37.
Zurück zum Zitat Michaud L, Burgess A, Huchet V et al (2014) Is (18)f-fluorocholine-positron emission tomography/computerized tomography a new imaging tool for detecting hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism? J Clin Endocrinol Metab 99:4531–4536CrossRefPubMed Michaud L, Burgess A, Huchet V et al (2014) Is (18)f-fluorocholine-positron emission tomography/computerized tomography a new imaging tool for detecting hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism? J Clin Endocrinol Metab 99:4531–4536CrossRefPubMed
38.
Zurück zum Zitat Lezaic L, Rep S, Sever MJ et al (2014) 18F-Fluorocholine PET/CT for localization of hyperfunctioning parathyroid tissue in primary hyperparathyroidism: a pilot study. Eur J Nucl Med Mol Imaging 41:2083–2089CrossRefPubMed Lezaic L, Rep S, Sever MJ et al (2014) 18F-Fluorocholine PET/CT for localization of hyperfunctioning parathyroid tissue in primary hyperparathyroidism: a pilot study. Eur J Nucl Med Mol Imaging 41:2083–2089CrossRefPubMed
39.
Zurück zum Zitat Caldarella C, Treglia G, Isgro MA et al (2013) Diagnostic performance of positron emission tomography using 11C-methionine in patients with suspected parathyroid adenoma: a meta-analysis. Endocrine 43:78–83CrossRefPubMed Caldarella C, Treglia G, Isgro MA et al (2013) Diagnostic performance of positron emission tomography using 11C-methionine in patients with suspected parathyroid adenoma: a meta-analysis. Endocrine 43:78–83CrossRefPubMed
40.
Zurück zum Zitat Cheung K, Wang TS, Farrokhyar F et al (2012) A meta-analysis of preoperative localization techniques for patients with primary hyperparathyroidism. Ann Surg Oncol 19:577–583CrossRefPubMed Cheung K, Wang TS, Farrokhyar F et al (2012) A meta-analysis of preoperative localization techniques for patients with primary hyperparathyroidism. Ann Surg Oncol 19:577–583CrossRefPubMed
41.
Zurück zum Zitat Treglia G, Sadeghi R, Schalin-Jantti C et al (2015) Detection rate of 99m Tc-MIBI single photon emission computed tomography (SPECT)/CT in preoperative planning for patients with primary hyperparathyrodism: a meta-analysis. Head Neck. doi:10.1002/hed.24027 PubMed Treglia G, Sadeghi R, Schalin-Jantti C et al (2015) Detection rate of 99m Tc-MIBI single photon emission computed tomography (SPECT)/CT in preoperative planning for patients with primary hyperparathyrodism: a meta-analysis. Head Neck. doi:10.​1002/​hed.​24027 PubMed
42.
Zurück zum Zitat Hoang JK, Sung W, Bahl M et al (2014) How to perform parathyroid 4D CT: tips and traps for technique and interpretation. Radiology 270:15–24CrossRefPubMed Hoang JK, Sung W, Bahl M et al (2014) How to perform parathyroid 4D CT: tips and traps for technique and interpretation. Radiology 270:15–24CrossRefPubMed
43.
Zurück zum Zitat Mahajan A, Starker LF, Ghita M et al (2012) Parathyroid four-dimensional computed tomography: evaluation of radiation dose exposure during preoperative localization of parathyroid tumors in primary hyperparathyroidism. World J Surg 36:1335–1339CrossRefPubMed Mahajan A, Starker LF, Ghita M et al (2012) Parathyroid four-dimensional computed tomography: evaluation of radiation dose exposure during preoperative localization of parathyroid tumors in primary hyperparathyroidism. World J Surg 36:1335–1339CrossRefPubMed
44.
Zurück zum Zitat Kluijfhout WP, Vriens MR, Valk GD et al (2015) 18F-Fluorocholine PET–CT enables minimal invasive parathyroidectomy in patients with negative sestamibi SPECT–CT and ultrasound: a case report. Int J Surg Case Rep 13:73–75CrossRefPubMedPubMedCentral Kluijfhout WP, Vriens MR, Valk GD et al (2015) 18F-Fluorocholine PET–CT enables minimal invasive parathyroidectomy in patients with negative sestamibi SPECT–CT and ultrasound: a case report. Int J Surg Case Rep 13:73–75CrossRefPubMedPubMedCentral
45.
Zurück zum Zitat Lubitz CC, Stephen AE, Hodin RA, Pandharipande P (2012) Preoperative localization strategies for primary hyperparathyroidism: an economic analysis. Ann Surg Oncol 19:4202–4209CrossRefPubMedPubMedCentral Lubitz CC, Stephen AE, Hodin RA, Pandharipande P (2012) Preoperative localization strategies for primary hyperparathyroidism: an economic analysis. Ann Surg Oncol 19:4202–4209CrossRefPubMedPubMedCentral
46.
Zurück zum Zitat Zald PB, Hamilton BE, Larsen ML, Cohen JI (2008) The role of computed tomography for localization of parathyroid adenomas. Laryngoscope 118:1405–1410CrossRefPubMed Zald PB, Hamilton BE, Larsen ML, Cohen JI (2008) The role of computed tomography for localization of parathyroid adenomas. Laryngoscope 118:1405–1410CrossRefPubMed
47.
Zurück zum Zitat Rodgers SE, Hunter GJ, Hamberg LM et al (2006) Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography. Surgery 140:932–941CrossRefPubMed Rodgers SE, Hunter GJ, Hamberg LM et al (2006) Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography. Surgery 140:932–941CrossRefPubMed
48.
Zurück zum Zitat Hunter GJ, Schellingerhout D, Vu TH et al (2012) Accuracy of four-dimensional CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Radiology 264:789–795CrossRefPubMed Hunter GJ, Schellingerhout D, Vu TH et al (2012) Accuracy of four-dimensional CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Radiology 264:789–795CrossRefPubMed
49.
Zurück zum Zitat Kukar M, Platz TA, Schaffner TJ et al (2015) The use of modified four-dimensional computed tomography in patients with primary hyperparathyroidism: an argument for the abandonment of routine sestamibi single-positron emission computed tomography (SPECT). Ann Surg Oncol 22:139–145CrossRefPubMed Kukar M, Platz TA, Schaffner TJ et al (2015) The use of modified four-dimensional computed tomography in patients with primary hyperparathyroidism: an argument for the abandonment of routine sestamibi single-positron emission computed tomography (SPECT). Ann Surg Oncol 22:139–145CrossRefPubMed
50.
Zurück zum Zitat Starker LF, Mahajan A, Bjorklund P, Sze G, Udelsman R, Carling T (2011) 4D parathyroid CT as the initial localization study for patients with de novo primary hyperparathyroidism. Ann Surg Oncol 18:1723–1728CrossRefPubMed Starker LF, Mahajan A, Bjorklund P, Sze G, Udelsman R, Carling T (2011) 4D parathyroid CT as the initial localization study for patients with de novo primary hyperparathyroidism. Ann Surg Oncol 18:1723–1728CrossRefPubMed
51.
Zurück zum Zitat Sacconi B, Argirò R, Diacinti D et al (2015) MR appearance of parathyroid adenomas at 3 T in patients with primary hyperparathyroidism: what radiologists need to know for pre-operative localization. Eur Radiol. doi:10.1007/s00330-015-3854-5 PubMed Sacconi B, Argirò R, Diacinti D et al (2015) MR appearance of parathyroid adenomas at 3 T in patients with primary hyperparathyroidism: what radiologists need to know for pre-operative localization. Eur Radiol. doi:10.​1007/​s00330-015-3854-5 PubMed
52.
Zurück zum Zitat Gotway MB, Reddy GP, Webb WR et al (2001) Comparison between MR imaging and 99mTc MIBI scintigraphy in the evaluation of recurrent of persistent hyperparathyroidism. Radiology 218:783–790CrossRefPubMed Gotway MB, Reddy GP, Webb WR et al (2001) Comparison between MR imaging and 99mTc MIBI scintigraphy in the evaluation of recurrent of persistent hyperparathyroidism. Radiology 218:783–790CrossRefPubMed
Metadaten
Titel
Use of PET tracers for parathyroid localization: a systematic review and meta-analysis
verfasst von
Wouter P. Kluijfhout
Jesse D. Pasternak
Frederick Thurston Drake
Toni Beninato
Jessica E. Gosnell
Wen T. Shen
Quan-Yang Duh
Isabel E. Allen
Menno R. Vriens
Bart de Keizer
Miguel H. Pampaloni
Insoo Suh
Publikationsdatum
16.04.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Langenbeck's Archives of Surgery / Ausgabe 7/2016
Print ISSN: 1435-2443
Elektronische ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-016-1425-0

Weitere Artikel der Ausgabe 7/2016

Langenbeck's Archives of Surgery 7/2016 Zur Ausgabe

Chirurginnen nehmen sich Zwischenfälle im OP besonders zu Herzen

05.06.2024 Allgemeine Chirurgie Nachrichten

Selbstverschuldete Fehler oder unerwartete Komplikationen machen jungen Chirurginnen und Operateuren mit Migrationshintergrund offenbar besonders zu schaffen. Benötigt werden routinemäßige Programme zum Umgang mit Zwischenfällen im OP.

Schützt auch die medikamentöse Gewichtsreduktion vor Krebs?

03.06.2024 ASCO 2024 Kongressbericht

Offenbar muss es nicht immer die bariatrische Chirurgie sein, wenn es darum geht, durch deutlichen Gewichtsverlust auch das Krebsrisiko günstig zu beeinflussen. Eine große Kohortenanalyse zur Behandlung mit GLP-1-Agonisten wurde dazu auf der ASCO-Tagung vorgestellt.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.