Skip to main content
Erschienen in: Surgical Endoscopy 1/2006

01.01.2006

Screen height as an ergonomic factor in laparoscopic surgery

verfasst von: J. Zehetner, A. Kaltenbacher, W. Wayand, A. Shamiyeh

Erschienen in: Surgical Endoscopy | Ausgabe 1/2006

Einloggen, um Zugang zu erhalten

Abstract

Background:

The increasing number of routinely performed laparoscopic operations causes the surgeons’ “screen work” time to rise constantly. A new ergonomic workload on the surgeons’ upper spine and shoulders is created as a result of the standard screen height position on top of the laparoscopy towers.

Methods:

Eight surgeons in the authors’ surgical department were evaluated for the inclination/reclination angle of their cervical spine when using the laparoscopy towers in the authors’ department and also at their favorable screen height.

Results:

The laparoscopy towers used in the authors’ department made 3° to 14° reclination of the cervical spine necessary. The interviewed surgeons preferred a position of slight inclination, with a median of 160 cm measured from the central screen height to the floor.

Conclusion:

Monitors of laparoscopy towers should be adapted to the surgeon’s preferred screen height: at eye level frontally with a neutral or slight inclination of the cervical spine. The authors suggest a central screen height of 160 cm, with the monitor positioned in front of the surgeon. Newer equipment from the industry should be provided.
Literatur
1.
Zurück zum Zitat Berguer R, Forkey DL, Smith WD (1999) Ergonomic problems associated with laparoscopic surgery. Surg Endosc 13: 466–468PubMedCrossRef Berguer R, Forkey DL, Smith WD (1999) Ergonomic problems associated with laparoscopic surgery. Surg Endosc 13: 466–468PubMedCrossRef
2.
Zurück zum Zitat Berguer R, Forkey DL, Smith WD (2001) The effect of laparoscopic instrument working angle on surgeons’ upper extremity workload. Surg Endosc 15:1027–1029PubMedCrossRef Berguer R, Forkey DL, Smith WD (2001) The effect of laparoscopic instrument working angle on surgeons’ upper extremity workload. Surg Endosc 15:1027–1029PubMedCrossRef
3.
Zurück zum Zitat Berguer R, Gerber S, Kilpatrick G, Remler M, Beckley D (1999) A comparison of forearm and thumb muscle electromyographic responses to the use of laparoscopic instruments with either a finger grasp or a palm grasp. Ergonomics 42: 1634–1645PubMedCrossRef Berguer R, Gerber S, Kilpatrick G, Remler M, Beckley D (1999) A comparison of forearm and thumb muscle electromyographic responses to the use of laparoscopic instruments with either a finger grasp or a palm grasp. Ergonomics 42: 1634–1645PubMedCrossRef
4.
Zurück zum Zitat Berguer R, Rab GT, Abu-Ghaida H, Alarcon A, Chung J (1997) A comparison of surgeons’ posture during laparoscopic and open surgical procedures. Surg Endosc 11: 139–142PubMedCrossRef Berguer R, Rab GT, Abu-Ghaida H, Alarcon A, Chung J (1997) A comparison of surgeons’ posture during laparoscopic and open surgical procedures. Surg Endosc 11: 139–142PubMedCrossRef
5.
Zurück zum Zitat Berguer R, Smith WD, Chung YH (2001) Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery. Surg Endosc 15: 1204–1207PubMedCrossRef Berguer R, Smith WD, Chung YH (2001) Performing laparoscopic surgery is significantly more stressful for the surgeon than open surgery. Surg Endosc 15: 1204–1207PubMedCrossRef
6.
Zurück zum Zitat Berquer R, Smith WD, Davis S (2002) An ergonomic study of the optimum operating table height for laparoscopic surgery. Surg Endosc 16: 416–421PubMedCrossRef Berquer R, Smith WD, Davis S (2002) An ergonomic study of the optimum operating table height for laparoscopic surgery. Surg Endosc 16: 416–421PubMedCrossRef
7.
Zurück zum Zitat Brown SI, White C, Wipat K, Hanna GB, Frank TG, Cuschieri A (2004) Characterizing the “gold standard” image for laparoscopic surgery. Surg Endosc 18: 1192–1195PubMedCrossRef Brown SI, White C, Wipat K, Hanna GB, Frank TG, Cuschieri A (2004) Characterizing the “gold standard” image for laparoscopic surgery. Surg Endosc 18: 1192–1195PubMedCrossRef
8.
Zurück zum Zitat Hanna GB, Shimi S, Cuschieri A (1997) Influence of direction of view, target-to-endoscope distance, and manipulation angle on endoscopic knot tying. Br J Surg 84: 1460–1464PubMedCrossRef Hanna GB, Shimi S, Cuschieri A (1997) Influence of direction of view, target-to-endoscope distance, and manipulation angle on endoscopic knot tying. Br J Surg 84: 1460–1464PubMedCrossRef
9.
Zurück zum Zitat Hanna GB, Shimi SM, Cuschieri A (1998) Task performance in endoscopic surgery is influenced by location of the image display. Ann Surg 227: 481–484PubMedCrossRef Hanna GB, Shimi SM, Cuschieri A (1998) Task performance in endoscopic surgery is influenced by location of the image display. Ann Surg 227: 481–484PubMedCrossRef
10.
Zurück zum Zitat Matern U, Faist M, Kehl K, Giebmeyer C, Buess G (2005) Monitor position in laparoscopic surgery. Surg Endosc 19: 436–440; Epub Jan 10, 2005PubMedCrossRef Matern U, Faist M, Kehl K, Giebmeyer C, Buess G (2005) Monitor position in laparoscopic surgery. Surg Endosc 19: 436–440; Epub Jan 10, 2005PubMedCrossRef
11.
Zurück zum Zitat Matern U, Kuttler G, Giebmeyer C, Waller P, Faist M (2004) Ergonomic aspects of five different types of laparoscopic instrument handles under dynamic conditions with respect to specific laparoscopic tasks: an electromyographic-based study. Surg Endosc 18: 1231–1241PubMedCrossRef Matern U, Kuttler G, Giebmeyer C, Waller P, Faist M (2004) Ergonomic aspects of five different types of laparoscopic instrument handles under dynamic conditions with respect to specific laparoscopic tasks: an electromyographic-based study. Surg Endosc 18: 1231–1241PubMedCrossRef
12.
Zurück zum Zitat Smith WD, Berguer R, Nguyen NT (2005) Monitor height affects surgeons’ stress level and performance on minimally invasive surgery tasks. Stud Health Technol Inform 111: 498–501PubMed Smith WD, Berguer R, Nguyen NT (2005) Monitor height affects surgeons’ stress level and performance on minimally invasive surgery tasks. Stud Health Technol Inform 111: 498–501PubMed
13.
Zurück zum Zitat Veelen MA, Jakimowicz JJ, Goossens RH, Meijer DW, Bussmann JB (2002) Evaluation of the usability of two types of image display systems during laparoscopy. Surg Endosc 16: 674–8, Epub December 31, 2001CrossRef Veelen MA, Jakimowicz JJ, Goossens RH, Meijer DW, Bussmann JB (2002) Evaluation of the usability of two types of image display systems during laparoscopy. Surg Endosc 16: 674–8, Epub December 31, 2001CrossRef
Metadaten
Titel
Screen height as an ergonomic factor in laparoscopic surgery
verfasst von
J. Zehetner
A. Kaltenbacher
W. Wayand
A. Shamiyeh
Publikationsdatum
01.01.2006
Erschienen in
Surgical Endoscopy / Ausgabe 1/2006
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-005-0251-1

Weitere Artikel der Ausgabe 1/2006

Surgical Endoscopy 1/2006 Zur Ausgabe

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Was nützt die Kraniektomie bei schwerer tiefer Hirnblutung?

17.05.2024 Hirnblutung Nachrichten

Eine Studie zum Nutzen der druckentlastenden Kraniektomie nach schwerer tiefer supratentorieller Hirnblutung deutet einen Nutzen der Operation an. Für überlebende Patienten ist das dennoch nur eine bedingt gute Nachricht.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.