Comparison of ejection fraction calculation between CT and SPECT at high heart rate: A dynamic cardiac phantom study

verfasst von: Chien-Cheng Chen, MD, Thau-Yun Shen, MD, Christine B. Peterson, PhD, Guang-Uei Hung, MD, Tinsu Pan, PhD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 1/2021

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study is to compare the ejection fraction (EF) calculation of CT and SPECT at high heart rate. A dynamic cardiac phantom with programmable end-systolic volume (ESV), end-diastolic volume (EDV), and heart rate was used to compare CT, which has high spatial resolution (< 1 mm) and modest temporal resolution of 175 msec, and SPECT, which has high temporal resolution of 16 bins per cardiac cycle but poor spatial resolution (> 1 cm) in EF, ESV, and EDV at the heart rates ≤ 100 bpm for EF = 30 (disease state) and EF = 60 (healthy state). EF calculations for SPECT were accurate in 2% for 40 to 100 bpm for both EF = 30 and EF = 60, and were not heart rate dependent although both ESV and EDV could be underestimated by 18-20%. EF calculations for CT were accurate in 2.2% for 40 and 60 bpm. Inaccuracy in EF calculations, ESV and EDV estimates increased when the heart rate or EF increased. SPECT was accurate for EF calculation for the heart rates ≤ 100 bpm and CT was accurate for the heart rates of ≤ 60 bpm. CT was less accurate for the high heart rates of 80 and 100 bpm, or high EF = 60.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Marcassa C, et al. Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: A position statement. Eur Heart J 2008;29:557-63.CrossRef Marcassa C, et al. Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: A position statement. Eur Heart J 2008;29:557-63.CrossRef
2.
Zurück zum Zitat Smanio PE, et al. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol 1997;30:1687-92.CrossRef Smanio PE, et al. Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol 1997;30:1687-92.CrossRef
3.
Zurück zum Zitat Sharir T, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999;100:1035-42.CrossRef Sharir T, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999;100:1035-42.CrossRef
4.
Zurück zum Zitat Asferg C, et al. Accuracy of multi-slice computed tomography for measurement of left ventricular ejection fraction compared with cardiac magnetic resonance imaging and two-dimensional transthoracic echocardiography: A systematic review and meta-analysis. Eur J Radiol 2012;81:e757-62.CrossRef Asferg C, et al. Accuracy of multi-slice computed tomography for measurement of left ventricular ejection fraction compared with cardiac magnetic resonance imaging and two-dimensional transthoracic echocardiography: A systematic review and meta-analysis. Eur J Radiol 2012;81:e757-62.CrossRef
5.
Zurück zum Zitat Demir H, et al. Comparison of gated SPECT, echocardiography and cardiac magnetic resonance imaging for the assessment of left ventricular ejection fraction and volumes. Ann Saudi Med 2007;27:415-20.CrossRef Demir H, et al. Comparison of gated SPECT, echocardiography and cardiac magnetic resonance imaging for the assessment of left ventricular ejection fraction and volumes. Ann Saudi Med 2007;27:415-20.CrossRef
7.
Zurück zum Zitat Hippelainen E, et al. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR. EJNMMI Phys 2017;4:20.CrossRef Hippelainen E, et al. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR. EJNMMI Phys 2017;4:20.CrossRef
8.
Zurück zum Zitat Chrysanthou-Baustert I, et al. Diagnostic sensitivity of SPECT myocardial perfusion imaging using a pumping cardiac phantom with inserted variable defects. J Nucl Cardiol 2013;20:609-15.CrossRef Chrysanthou-Baustert I, et al. Diagnostic sensitivity of SPECT myocardial perfusion imaging using a pumping cardiac phantom with inserted variable defects. J Nucl Cardiol 2013;20:609-15.CrossRef
9.
Zurück zum Zitat Polycarpou I, et al. Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects. J Nucl Cardiol 2017;24:1216-25.CrossRef Polycarpou I, et al. Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects. J Nucl Cardiol 2017;24:1216-25.CrossRef
10.
Zurück zum Zitat Jacobs JE, et al. ACR practice guideline for the performance and interpretation of cardiac computed tomography (CT). J Am Coll Radiol 2006;3:677-85.CrossRef Jacobs JE, et al. ACR practice guideline for the performance and interpretation of cardiac computed tomography (CT). J Am Coll Radiol 2006;3:677-85.CrossRef
11.
Zurück zum Zitat Maceira AM, et al. Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2006;8:417-26.CrossRef Maceira AM, et al. Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2006;8:417-26.CrossRef
12.
Zurück zum Zitat Bailliez A, et al. Left ventricular function assessment using 2 different cadmium-zinc-telluride cameras compared with a gamma-camera with cardiofocal collimators: Dynamic cardiac phantom study and clinical validation. J Nucl Med 2016;57:1370-5.CrossRef Bailliez A, et al. Left ventricular function assessment using 2 different cadmium-zinc-telluride cameras compared with a gamma-camera with cardiofocal collimators: Dynamic cardiac phantom study and clinical validation. J Nucl Med 2016;57:1370-5.CrossRef
13.
Zurück zum Zitat Miller JC, et al. Dual-source CT for cardiac imaging. J Am Coll Radiol 2009;6:65-8.CrossRef Miller JC, et al. Dual-source CT for cardiac imaging. J Am Coll Radiol 2009;6:65-8.CrossRef
14.
Zurück zum Zitat Zhang W, et al. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI. Pediatr Radiol 2017;47:1588-93.CrossRef Zhang W, et al. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI. Pediatr Radiol 2017;47:1588-93.CrossRef
Metadaten
Titel
Comparison of ejection fraction calculation between CT and SPECT at high heart rate: A dynamic cardiac phantom study
verfasst von
Chien-Cheng Chen, MD
Thau-Yun Shen, MD
Christine B. Peterson, PhD
Guang-Uei Hung, MD
Tinsu Pan, PhD
Publikationsdatum
06.01.2020
Verlag
Springer International Publishing
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 1/2021
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-019-01991-7

Weitere Artikel der Ausgabe 1/2021

Journal of Nuclear Cardiology 1/2021 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.