Skip to main content
Erschienen in: Intensive Care Medicine 1/2005

01.01.2005 | Review

Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-analysis of randomized controlled trials

verfasst von: Axel Kola, Tim Eckmanns, Petra Gastmeier

Erschienen in: Intensive Care Medicine | Ausgabe 1/2005

Einloggen, um Zugang zu erhalten

Abstract

Objective

Several randomized controlled trials (RCT) have examined the effect of antibacterial humidification strategies, particularly the replacement of heated humidifiers (HH) by heat and moisture exchangers (HME), in preventing ventilator-associated pneumonia (VAP). The present meta-analysis reviews these RCTs.

Methods

RCTs were identified by searching the Medline and Cochrane Central Register of Controlled Trials databases from 1990 to 2003. We included RCTs using HMEs in the treatment group and HHs in the control group and reporting the incidence of pneumonia as a study outcome. Two investigators independently abstracted key data on design, population, intervention and outcome of the studies.

Results

Between 1990 and 2003 eight RCTs met the inclusion criteria of this analysis. Pooling the results from these studies revealed a reduction in the relative risk of VAP in the HME group (0.7), particularly in MV with a duration of at least 7 days (five RCTs, relative risk 0.57).

Conclusions

This meta-analysis found a significant reduction in the incidence of VAP in patients humidified with HMEs during MV, particularly in patients ventilated for 7 days or longer. This finding is limited by the exclusion of patients at high risk for airway occlusion from some of the studies. Moreover, contraindications (tenacious secretions, airway obstructive disease, hypothermia) and technical issues of HMEs must be considered. Further RCTs are necessary to examine the wider applicability of HMEs and their extended use.
Literatur
1.
Zurück zum Zitat Gastmeier P, Geffers C, Sohr D, Dettenkofer M, Daschner F, Ruden H (2003) Five years working with the German nosocomial infection surveillance system (Krankenhaus Infektions Surveillance System). Am J Infect Control 31:316CrossRefPubMed Gastmeier P, Geffers C, Sohr D, Dettenkofer M, Daschner F, Ruden H (2003) Five years working with the German nosocomial infection surveillance system (Krankenhaus Infektions Surveillance System). Am J Infect Control 31:316CrossRefPubMed
2.
3.
Zurück zum Zitat Chastre J, Fagon JY (2002) Ventilator-associated pneumonia. Am J Respir Crit Care Med 165:867PubMed Chastre J, Fagon JY (2002) Ventilator-associated pneumonia. Am J Respir Crit Care Med 165:867PubMed
4.
Zurück zum Zitat Craven DE, Steger KA (1995) Epidemiology of nosocomial pneumonia. New perspectives on an old disease. Chest 108:1SPubMed Craven DE, Steger KA (1995) Epidemiology of nosocomial pneumonia. New perspectives on an old disease. Chest 108:1SPubMed
5.
Zurück zum Zitat Branson RD (1998) The effects of inadequate humidity. Respir Care Clin N Am 4:199PubMed Branson RD (1998) The effects of inadequate humidity. Respir Care Clin N Am 4:199PubMed
6.
Zurück zum Zitat Tablan OC, Anderson LJ, Besser R, Bridges C, Hajjeh R (2004) Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep 53:1 Tablan OC, Anderson LJ, Besser R, Bridges C, Hajjeh R (2004) Guidelines for preventing health-care-associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep 53:1
7.
Zurück zum Zitat Branson RD, Campbell RS (1998) Humidification in the intensive care unit. Respir Care Clin N Am 4:305PubMed Branson RD, Campbell RS (1998) Humidification in the intensive care unit. Respir Care Clin N Am 4:305PubMed
8.
Zurück zum Zitat Martin C, Perrin G, Gevaudan MJ, Saux P, Gouin F (1990) Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 97:144PubMed Martin C, Perrin G, Gevaudan MJ, Saux P, Gouin F (1990) Heat and moisture exchangers and vaporizing humidifiers in the intensive care unit. Chest 97:144PubMed
9.
Zurück zum Zitat Roustan JP, Kienlen J, Aubas P, Aubas S, du Cailar J (1992) Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 18:97PubMed Roustan JP, Kienlen J, Aubas P, Aubas S, du Cailar J (1992) Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 18:97PubMed
10.
Zurück zum Zitat Dreyfuss D, Djedaini K, Gros I, Mier L, Le Bourdelles G, Cohen Y, Estagnasie P, Coste F, Boussougant Y (1995) Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 151:986PubMed Dreyfuss D, Djedaini K, Gros I, Mier L, Le Bourdelles G, Cohen Y, Estagnasie P, Coste F, Boussougant Y (1995) Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patient colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 151:986PubMed
11.
Zurück zum Zitat Branson RD, Davis K Jr, Brown R, Rashkin M (1996) Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care 41:809 Branson RD, Davis K Jr, Brown R, Rashkin M (1996) Comparison of three humidification techniques during mechanical ventilation: patient selection, cost, and infection considerations. Respir Care 41:809
12.
Zurück zum Zitat Kirton OC, DeHaven B, Morgan J, Morejon O, Civetta J (1997) A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 112:1055PubMed Kirton OC, DeHaven B, Morgan J, Morejon O, Civetta J (1997) A prospective, randomized comparison of an in-line heat moisture exchange filter and heated wire humidifiers: rates of ventilator-associated early-onset (community-acquired) or late-onset (hospital-acquired) pneumonia and incidence of endotracheal tube occlusion. Chest 112:1055PubMed
13.
Zurück zum Zitat Boots RJ, Howe S, George N, Harris FM, Faoagali J (1997) Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 25:1707CrossRefPubMed Boots RJ, Howe S, George N, Harris FM, Faoagali J (1997) Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 25:1707CrossRefPubMed
14.
Zurück zum Zitat Kollef MH, Shapiro SD, Boyd V, Silver P, Von Harz B, Trovillion E, Prentice D (1998) A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 113:759PubMed Kollef MH, Shapiro SD, Boyd V, Silver P, Von Harz B, Trovillion E, Prentice D (1998) A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients. Chest 113:759PubMed
15.
Zurück zum Zitat Memish ZA, Oni GA, Djazmati W, Cunningham G, Mah MW (2001) A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 29:301CrossRefPubMed Memish ZA, Oni GA, Djazmati W, Cunningham G, Mah MW (2001) A randomized clinical trial to compare the effects of a heat and moisture exchanger with a heated humidifying system on the occurrence rate of ventilator-associated pneumonia. Am J Infect Control 29:301CrossRefPubMed
16.
Zurück zum Zitat Cook D, De Jonghe B, Brochard L, Brun-Buisson C (1998) Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 279:781CrossRefPubMed Cook D, De Jonghe B, Brochard L, Brun-Buisson C (1998) Influence of airway management on ventilator-associated pneumonia: evidence from randomized trials. JAMA 279:781CrossRefPubMed
17.
Zurück zum Zitat Bench S (2003) Humidification in the long-term ventilated patient; a systematic review. Intensive Crit Care Nurs 19:75CrossRefPubMed Bench S (2003) Humidification in the long-term ventilated patient; a systematic review. Intensive Crit Care Nurs 19:75CrossRefPubMed
19.
Zurück zum Zitat Hess D (2002) Infection control in the intensive care unit. The role of the ventilator circuit. Minerva Anestesiol 68:356PubMed Hess D (2002) Infection control in the intensive care unit. The role of the ventilator circuit. Minerva Anestesiol 68:356PubMed
20.
21.
Zurück zum Zitat Richards G (1998) The role of filtration during humidification. Respir Care Clin N Am 4:329PubMed Richards G (1998) The role of filtration during humidification. Respir Care Clin N Am 4:329PubMed
22.
Zurück zum Zitat Littlewood K, Durbin CG Jr (2001) Evidenced-based airway management. Respir Care 46:1392PubMed Littlewood K, Durbin CG Jr (2001) Evidenced-based airway management. Respir Care 46:1392PubMed
23.
Zurück zum Zitat Hurni JM, Feihl F, Lazor R, Leuenberger P, Perret C (1997) Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest 111:686PubMed Hurni JM, Feihl F, Lazor R, Leuenberger P, Perret C (1997) Safety of combined heat and moisture exchanger filters in long-term mechanical ventilation. Chest 111:686PubMed
24.
Zurück zum Zitat Davis K Jr, Evans SL, Campbell RS, Johannigman JA, Luchette FA, Porembka DT, Branson RD (2000) Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 28:1412CrossRefPubMed Davis K Jr, Evans SL, Campbell RS, Johannigman JA, Luchette FA, Porembka DT, Branson RD (2000) Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia. Crit Care Med 28:1412CrossRefPubMed
25.
Zurück zum Zitat Thomachot L, Leone M, Razzouk K, Antonini F, Vialet R, Martin C (2002) Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 30:232CrossRefPubMed Thomachot L, Leone M, Razzouk K, Antonini F, Vialet R, Martin C (2002) Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days. Crit Care Med 30:232CrossRefPubMed
26.
Zurück zum Zitat Thomachot L, Boisson C, Arnaud S, Michelet P, Cambon S, Martin C (2000) Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Crit Care Med 28:714CrossRefPubMed Thomachot L, Boisson C, Arnaud S, Michelet P, Cambon S, Martin C (2000) Changing heat and moisture exchangers after 96 hours rather than after 24 hours: a clinical and microbiological evaluation. Crit Care Med 28:714CrossRefPubMed
27.
Zurück zum Zitat Ricard JD, Le Miere E, Markowicz P, Lasry S, Saumon G, Djedaini K, Coste F, Dreyfuss D (2000) Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 161:104PubMed Ricard JD, Le Miere E, Markowicz P, Lasry S, Saumon G, Djedaini K, Coste F, Dreyfuss D (2000) Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 161:104PubMed
28.
Zurück zum Zitat Thomachot L, Viviand X, Arnaud S, Boisson C, Martin CD (1998) Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 114:1383PubMed Thomachot L, Viviand X, Arnaud S, Boisson C, Martin CD (1998) Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia. Chest 114:1383PubMed
29.
Zurück zum Zitat Thomachot L, Vialet R, Arnaud S, Barberon B, Michel-Nguyen A, Martin C (1999) Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Crit Care Med 27:923CrossRefPubMed Thomachot L, Vialet R, Arnaud S, Barberon B, Michel-Nguyen A, Martin C (1999) Do the components of heat and moisture exchanger filters affect their humidifying efficacy and the incidence of nosocomial pneumonia? Crit Care Med 27:923CrossRefPubMed
30.
Zurück zum Zitat Lorente L, Lecuona M, Malaga J, Revert C, Mora ML, Sierra A (2003) Bacterial filters in respiratory circuits: an unnecessary cost? Crit Care Med 31:2126CrossRefPubMed Lorente L, Lecuona M, Malaga J, Revert C, Mora ML, Sierra A (2003) Bacterial filters in respiratory circuits: an unnecessary cost? Crit Care Med 31:2126CrossRefPubMed
31.
Zurück zum Zitat Ibrahim EH, Ward S, Sherman G, Kollef MH (2000) A comparative analysis of patients with early-onset vs late-onset nosocomial pneumonia in the ICU setting. Chest 117:1434CrossRefPubMed Ibrahim EH, Ward S, Sherman G, Kollef MH (2000) A comparative analysis of patients with early-onset vs late-onset nosocomial pneumonia in the ICU setting. Chest 117:1434CrossRefPubMed
32.
Zurück zum Zitat American Thoracic Society (1996) Hospital-acquired pneumonia in adults: diagnosis, assessment of severity, initial antimicrobial therapy, and preventive strategies. Am J Respir Crit Care Med 153:1711PubMed American Thoracic Society (1996) Hospital-acquired pneumonia in adults: diagnosis, assessment of severity, initial antimicrobial therapy, and preventive strategies. Am J Respir Crit Care Med 153:1711PubMed
33.
Zurück zum Zitat Vincent JL, Lobo S, Struelens M (2001) Ventilator associated pneumonia: risk factors and preventive measures. J Chemother 13 [Spec no 1]:211 Vincent JL, Lobo S, Struelens M (2001) Ventilator associated pneumonia: risk factors and preventive measures. J Chemother 13 [Spec no 1]:211
34.
Zurück zum Zitat Bertrand X, Thouverez M, Talon D, Boillot A, Capellier G, Floriot C, Helias JP (2001) Endemicity, molecular diversity and colonisation routes of Pseudomonas aeruginosa in intensive care units. Intensive Care Med 27:1263CrossRefPubMed Bertrand X, Thouverez M, Talon D, Boillot A, Capellier G, Floriot C, Helias JP (2001) Endemicity, molecular diversity and colonisation routes of Pseudomonas aeruginosa in intensive care units. Intensive Care Med 27:1263CrossRefPubMed
35.
Zurück zum Zitat Thomachot L, Viviand X, Boyadjiev I, Vialet R, Martin C (2002) The combination of a heat and moisture exchanger and a Booster: a clinical and bacteriological evaluation over 96 h. Intensive Care Med 28:147CrossRefPubMed Thomachot L, Viviand X, Boyadjiev I, Vialet R, Martin C (2002) The combination of a heat and moisture exchanger and a Booster: a clinical and bacteriological evaluation over 96 h. Intensive Care Med 28:147CrossRefPubMed
36.
Zurück zum Zitat Prin S, Chergui K, Augarde R, Page B, Jardin F, Vieillard-Baron A (2002) Ability and safety of a heated humidifier to control hypercapnic acidosis in severe ARDS. Intensive Care Med 28:1756CrossRefPubMed Prin S, Chergui K, Augarde R, Page B, Jardin F, Vieillard-Baron A (2002) Ability and safety of a heated humidifier to control hypercapnic acidosis in severe ARDS. Intensive Care Med 28:1756CrossRefPubMed
37.
Zurück zum Zitat Branson RD, Davis K Jr, Campbell RS, Johnson DJ, Porembka DT (1993) Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 104:1800PubMed Branson RD, Davis K Jr, Campbell RS, Johnson DJ, Porembka DT (1993) Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 104:1800PubMed
Metadaten
Titel
Efficacy of heat and moisture exchangers in preventing ventilator-associated pneumonia: meta-analysis of randomized controlled trials
verfasst von
Axel Kola
Tim Eckmanns
Petra Gastmeier
Publikationsdatum
01.01.2005
Verlag
Springer-Verlag
Erschienen in
Intensive Care Medicine / Ausgabe 1/2005
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-004-2431-1

Weitere Artikel der Ausgabe 1/2005

Intensive Care Medicine 1/2005 Zur Ausgabe

Announcements

January 2005

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.