01.06.2011 | Physiological and Technical Notes

Performance of different continuous positive airway pressure helmets equipped with safety valves during failure of fresh gas supply

verfasst von: Manuela Milan, Alberto Zanella, Stefano Isgrò, Salua Abd El Aziz El Sayed Deab, Federico Magni, Antonio Pesenti, Nicolò Patroniti

Erschienen in: Intensive Care Medicine | Ausgabe 6/2011

Einloggen, um Zugang zu erhalten

Abstract

Purpose

We assessed the performance of different continuous positive airway pressure (CPAP) helmets equipped with a safety valve during discontinuation of fresh gas flow.

Methods

This was a physiological study of five healthy volunteers. We delivered CPAP (fresh gas flow 60 l/min, FiO2 60%, PEEP 5 cmH2O) with three different helmets in a random sequence: 4Vent (Rüsch), HelmHAR-cp (Harol) and CaStar CP210 (StarMed). For each helmet we randomly applied, for up to 4 min, three disconnections of fresh gas flow: helmet inlet (Dinlet), flowmeter (Dflowmeter) and gas source (Dsource). We continuously recorded from a nostril: end-tidal CO2 (PetCO2), inspiratory CO2 (PiCO2), fraction of inspired oxygen (FiO2) and respiratory rate (RR).

Results

During every disconnection we observed an increase in PiCO2 and PetCO2 with a drop in FiO2, while RR did not change. FiO2 decreased more quickly in the CaStar, equipped with the largest safety valve, during Dsource and Dflowmeter, while FiO2 decreased more quickly during Dinlet in CaStar and in 4Vent. PiCO2 resulted in a lower increase in CaStar during Dsource and Dflowmeter compared to 4Vent. PetCO2 in CaStar increases more slowly compared to 4Vent during Dsource and more slowly compared to the other two helmets during Dflowmeter. During Dinlet similar degrees of CO2 rebreathing and PetCO2 were recorded among all the helmets.

Conclusions

To minimize CO2 rebreathing during disconnection of the fresh gas supply while performing helmet CPAP, it is desirable to utilize large helmets with a large anti-suffocation valve. Monitoring and alarm systems should be employed for safe application of helmet CPAP.
Literatur
1.
Zurück zum Zitat International Consensus Conferences in Intensive Care Medicine (2001) Noninvasive positive pressure ventilation in acute Respiratory failure. Am J Respir Crit Care Med 163:283–291 International Consensus Conferences in Intensive Care Medicine (2001) Noninvasive positive pressure ventilation in acute Respiratory failure. Am J Respir Crit Care Med 163:283–291
2.
Zurück zum Zitat Bellani G, Patroniti N, Greco M, Foti G, Pesenti A (2008) The use of helmets to deliver non-invasive continuous positive airway pressure in hypoxemic acute respiratory failure. Minerva Anestesiol 74:651–656PubMed Bellani G, Patroniti N, Greco M, Foti G, Pesenti A (2008) The use of helmets to deliver non-invasive continuous positive airway pressure in hypoxemic acute respiratory failure. Minerva Anestesiol 74:651–656PubMed
3.
Zurück zum Zitat Taccone P, Hess D, Caironi P, Bigatello LM (2004) Continuous positive airway pressure delivered with a “helmet”: effects on carbon dioxide rebreathing. Crit Care Med 32:2090–2096PubMedCrossRef Taccone P, Hess D, Caironi P, Bigatello LM (2004) Continuous positive airway pressure delivered with a “helmet”: effects on carbon dioxide rebreathing. Crit Care Med 32:2090–2096PubMedCrossRef
4.
Zurück zum Zitat Patroniti N, Foti G, Manfio A, Coppo A, Bellani G, Pesenti A (2003) Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study. Intensive Care Med 29:1680–1687PubMedCrossRef Patroniti N, Foti G, Manfio A, Coppo A, Bellani G, Pesenti A (2003) Head helmet versus face mask for non-invasive continuous positive airway pressure: a physiological study. Intensive Care Med 29:1680–1687PubMedCrossRef
5.
Zurück zum Zitat Mojoli F, Iotti G, Gerletti M, Lucarini C, Braschi A (2008) Carbon dioxide rebreathing during non-invasive ventilation delivered by helmet: a bench study. Intensive Care Med 34:1454–1460PubMedCrossRef Mojoli F, Iotti G, Gerletti M, Lucarini C, Braschi A (2008) Carbon dioxide rebreathing during non-invasive ventilation delivered by helmet: a bench study. Intensive Care Med 34:1454–1460PubMedCrossRef
6.
Zurück zum Zitat Antonelli M, Pennisi MA, Montini L (2005) Clinical review: noninvasive ventilation in the clinical setting—experience from the past 10 years. Crit Care 9:98–103PubMedCrossRef Antonelli M, Pennisi MA, Montini L (2005) Clinical review: noninvasive ventilation in the clinical setting—experience from the past 10 years. Crit Care 9:98–103PubMedCrossRef
7.
Zurück zum Zitat Principi T, Pantanetti S, Catani F, Elisei D, Gabbanelli V, Pelaia P, Leoni P (2004) Noninvasive continuous positive airway pressure delivered by helmet in hematological malignancy patients with hypoxemic acute respiratory failure. Intensive Care Med 30:147–150PubMedCrossRef Principi T, Pantanetti S, Catani F, Elisei D, Gabbanelli V, Pelaia P, Leoni P (2004) Noninvasive continuous positive airway pressure delivered by helmet in hematological malignancy patients with hypoxemic acute respiratory failure. Intensive Care Med 30:147–150PubMedCrossRef
8.
Zurück zum Zitat Mehta S, Hill NS (2001) Noninvasive ventilation. Am J Respir Crit Care Med 163:540–577PubMed Mehta S, Hill NS (2001) Noninvasive ventilation. Am J Respir Crit Care Med 163:540–577PubMed
9.
Zurück zum Zitat Tonnelier JM, Prat G, Nowak E, Goetghebeur D, Renault A, Boles JM, L’Her E (2003) Noninvasive continuous positive airway pressure ventilation using a new helmet interface: a case-control prospective pilot study. Intensive Care Med 29:2077–2080PubMedCrossRef Tonnelier JM, Prat G, Nowak E, Goetghebeur D, Renault A, Boles JM, L’Her E (2003) Noninvasive continuous positive airway pressure ventilation using a new helmet interface: a case-control prospective pilot study. Intensive Care Med 29:2077–2080PubMedCrossRef
10.
Zurück zum Zitat Patroniti N, Saini M, Zanella A, Isgro S, Pesenti A (2007) Danger of helmet continuous positive airway pressure during failure of fresh gas source supply. Intensive Care Med 33:153–157PubMedCrossRef Patroniti N, Saini M, Zanella A, Isgro S, Pesenti A (2007) Danger of helmet continuous positive airway pressure during failure of fresh gas source supply. Intensive Care Med 33:153–157PubMedCrossRef
11.
Zurück zum Zitat Lofaso F, Brochard L, Hang T, Lorino H, Harf A, Isabey D (1996) Home versus intensive care pressure support devices. Experimental and clinical comparison. Am J Respir Crit Care Med 153:1591–1599PubMed Lofaso F, Brochard L, Hang T, Lorino H, Harf A, Isabey D (1996) Home versus intensive care pressure support devices. Experimental and clinical comparison. Am J Respir Crit Care Med 153:1591–1599PubMed
Metadaten
Titel
Performance of different continuous positive airway pressure helmets equipped with safety valves during failure of fresh gas supply
verfasst von
Manuela Milan
Alberto Zanella
Stefano Isgrò
Salua Abd El Aziz El Sayed Deab
Federico Magni
Antonio Pesenti
Nicolò Patroniti
Publikationsdatum
01.06.2011
Verlag
Springer-Verlag
Erschienen in
Intensive Care Medicine / Ausgabe 6/2011
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-011-2207-3

Weitere Artikel der Ausgabe 6/2011

Intensive Care Medicine 6/2011 Zur Ausgabe

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.