Skip to main content
Erschienen in: Skeletal Radiology 10/2012

01.10.2012 | Scientific Article

Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system

verfasst von: Ari Bertz, Kari Indrekvam, Mohamed Ahmed, Erling Englund, Arkan S. Sayed-Noor

Erschienen in: Skeletal Radiology | Ausgabe 10/2012

Einloggen, um Zugang zu erhalten

Abstract

Objectives

To evaluate the validity, interobserver reliability, and intraobserver reproducibility of a digital templating system, the Mdesk™ in preoperative templating in cemented and reverse hybrid total hip arthroplasty (THA).

Materials and methods

Validity was evaluated by comparing the planned cup size, stem size, CCD angles, and neck length with the components used in 129 patients operated with cemented and reverse hybrid THA. The reliability was measured by comparing the templating results of two surgeons with each other (interobserver) and the results of two templatings carried out by first surgeon (intraobserver). The leg length discrepancy was measured before and after the operation to assess the templating ability to correct it.

Results

The Mdesk™ system showed good validity (kappa value ranged from 0.64 to 0.96), especially when one size over and under the planned size were included. No difference between cemented and cementless stems was found. The interobserver reliability ranged from fair (kappa 0.23) to substantial (kappa 0.61) while the intraobserver reproducibility ranged from substantial (kappa 0.70) to excellent (kappa 0.82). Templating and intraoperative measures succeeded to restore the leg length.

Conclusions

The Mdesk™ system has comparable validity and reliability with other templating systems used in clinical practice. We recommend that the same surgeon who does the preoperative radiographic templating to also perform the operation. Further studies are required to evaluate the results of succeeded templating in the long run.
Literatur
1.
Zurück zum Zitat Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg [Br]. 1998;80-B:382.CrossRef Eggli S, Pisan M, Muller ME. The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg [Br]. 1998;80-B:382.CrossRef
2.
Zurück zum Zitat Blackley HR, Howell GE, Rorabeck CH. Planning and management of the difficult primary hip replacement: preoperative planning and technical considerations. Instr Course Lect. 2000;49:3–11.PubMed Blackley HR, Howell GE, Rorabeck CH. Planning and management of the difficult primary hip replacement: preoperative planning and technical considerations. Instr Course Lect. 2000;49:3–11.PubMed
3.
Zurück zum Zitat Bono JB. Digital templating in total hip arthroplasty. J Bone Joint Surg [Am]. 2004;86:118. Bono JB. Digital templating in total hip arthroplasty. J Bone Joint Surg [Am]. 2004;86:118.
4.
Zurück zum Zitat Della Valle AG, Padgett DE, Salvati EA. Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg. 2005;13:455.PubMed Della Valle AG, Padgett DE, Salvati EA. Preoperative planning for primary total hip arthroplasty. J Am Acad Orthop Surg. 2005;13:455.PubMed
5.
Zurück zum Zitat Knight JL, Atwater RD. Preoperative planning for total hip arthroplasty. J Arthroplasty. 1992;7(Suppl):403–9.PubMedCrossRef Knight JL, Atwater RD. Preoperative planning for total hip arthroplasty. J Arthroplasty. 1992;7(Suppl):403–9.PubMedCrossRef
6.
Zurück zum Zitat Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty. 1995;10:507–13.PubMedCrossRef Carter LW, Stovall DO, Young TR. Determination of accuracy of preoperative templating of noncemented femoral prostheses. J Arthroplasty. 1995;10:507–13.PubMedCrossRef
7.
Zurück zum Zitat Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty. 2005;20:51–8.PubMedCrossRef Gonzalez Della Valle A, Slullitel G, Piccaluga F, Salvati EA. The precision and usefulness of preoperative planning for cemented and hybrid primary total hip arthroplasty. J Arthroplasty. 2005;20:51–8.PubMedCrossRef
8.
Zurück zum Zitat Suh KT, Cheon SJ, Kim DW. Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand. 2004;75:40–4.PubMedCrossRef Suh KT, Cheon SJ, Kim DW. Comparison of preoperative templating with postoperative assessment in cementless total hip arthroplasty. Acta Orthop Scand. 2004;75:40–4.PubMedCrossRef
9.
Zurück zum Zitat Davila JA, Kransdorf MJ, Duffy GP. Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size. Skeletal Radiol. 2006;35:390–3.PubMedCrossRef Davila JA, Kransdorf MJ, Duffy GP. Surgical planning of total hip arthroplasty: accuracy of computer-assisted EndoMap software in predicting component size. Skeletal Radiol. 2006;35:390–3.PubMedCrossRef
10.
Zurück zum Zitat Olsen M, Gamble P, Chiu M, Tumia N, Boyle Schemitsch EH. Assessment of accuracy and reliability in preoperative templating for hip resurfacing arthroplasty. J Arthroplasty. 2010;25(3):445–9.PubMedCrossRef Olsen M, Gamble P, Chiu M, Tumia N, Boyle Schemitsch EH. Assessment of accuracy and reliability in preoperative templating for hip resurfacing arthroplasty. J Arthroplasty. 2010;25(3):445–9.PubMedCrossRef
11.
Zurück zum Zitat Gamble P, de Beer J, Petruccelli D, Winemaer M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty. 2010;25(4):529–32.PubMedCrossRef Gamble P, de Beer J, Petruccelli D, Winemaer M. The accuracy of digital templating in uncemented total hip arthroplasty. J Arthroplasty. 2010;25(4):529–32.PubMedCrossRef
12.
Zurück zum Zitat Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty. Is digital templating accurate and safe? J Arthroplasty. 2009;24(2):175–9.PubMedCrossRef Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty. Is digital templating accurate and safe? J Arthroplasty. 2009;24(2):175–9.PubMedCrossRef
13.
Zurück zum Zitat Steinberg EL, Shash N, Menahem A, Dekel S. Preoperative planning of total hip replacement using the TraumaCad™ system. Arch Orthop Trauma Surg. 2010;130:1429–32.PubMedCrossRef Steinberg EL, Shash N, Menahem A, Dekel S. Preoperative planning of total hip replacement using the TraumaCad™ system. Arch Orthop Trauma Surg. 2010;130:1429–32.PubMedCrossRef
14.
Zurück zum Zitat Zhao X, Zhu ZA, Zhao J, Li MQ, Wang G, Yu DG, et al. The utility of digital templating in total hip arthroplasty with Crowe type II and III dysplastic hips. Int Orthop. 2011;35:631–8.PubMedCrossRef Zhao X, Zhu ZA, Zhao J, Li MQ, Wang G, Yu DG, et al. The utility of digital templating in total hip arthroplasty with Crowe type II and III dysplastic hips. Int Orthop. 2011;35:631–8.PubMedCrossRef
15.
Zurück zum Zitat Efe T, El-Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J. Precision of preoperative digital templating in total hip arthroplasty. Acta Orthop Belg. 2011;77:616–21.PubMed Efe T, El-Zayat BF, Heyse TJ, Timmesfeld N, Fuchs-Winkelmann S, Schmitt J. Precision of preoperative digital templating in total hip arthroplasty. Acta Orthop Belg. 2011;77:616–21.PubMed
16.
Zurück zum Zitat Horneij E, Holmström E, Hemborg B, Isberg PE, Ekdahl C. Interrater reliability and between-days repeatability of eight physical performance tests. Adv Physiother. 2002;4:146–60.CrossRef Horneij E, Holmström E, Hemborg B, Isberg PE, Ekdahl C. Interrater reliability and between-days repeatability of eight physical performance tests. Adv Physiother. 2002;4:146–60.CrossRef
17.
Zurück zum Zitat Rheault W, Albright B, Byers C, Franta M, Johnson A, Skowronek M. Intertester reliability of the cervical range of motion device. J Orthop Sports Phys Ther. 1992;15:147–50.PubMed Rheault W, Albright B, Byers C, Franta M, Johnson A, Skowronek M. Intertester reliability of the cervical range of motion device. J Orthop Sports Phys Ther. 1992;15:147–50.PubMed
18.
Zurück zum Zitat Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.PubMedCrossRef Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–74.PubMedCrossRef
19.
Zurück zum Zitat Lindell O, Eriksson L, Strender L-E. The reliability of a 10-test package for patients with prolonged back and neck pain: could an examiner without formal medical education be used without loss of quality? A methodological study. BMC Musculoskelet Disord. 2007;8:31.PubMedCrossRef Lindell O, Eriksson L, Strender L-E. The reliability of a 10-test package for patients with prolonged back and neck pain: could an examiner without formal medical education be used without loss of quality? A methodological study. BMC Musculoskelet Disord. 2007;8:31.PubMedCrossRef
20.
Zurück zum Zitat Charnley J. Low friction arthroplasty of the hip. Berlin: Springer Verlag; 1979. p. 246.CrossRef Charnley J. Low friction arthroplasty of the hip. Berlin: Springer Verlag; 1979. p. 246.CrossRef
21.
Zurück zum Zitat Müller ME. Total hip replacement: planning, technique and complications. In: Surgical management of degenerative arthritis of the lower limb. Philadelphia: Lea and Faber 1975; 90–113. Müller ME. Total hip replacement: planning, technique and complications. In: Surgical management of degenerative arthritis of the lower limb. Philadelphia: Lea and Faber 1975; 90–113.
22.
Zurück zum Zitat Crooijmans H, Laumen A, van Pul C, van Mourik J. A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res. 2009;467(4):909–16.PubMedCrossRef Crooijmans H, Laumen A, van Pul C, van Mourik J. A new digital preoperative planning method for total hip arthroplasties. Clin Orthop Relat Res. 2009;467(4):909–16.PubMedCrossRef
23.
Zurück zum Zitat The B, Diercks R, van Ooijen P, Van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasty. Acta Orthop. 2005;76:78–84.PubMedCrossRef The B, Diercks R, van Ooijen P, Van Horn JR. Comparison of analog and digital preoperative planning in total hip and knee arthroplasty. Acta Orthop. 2005;76:78–84.PubMedCrossRef
24.
Zurück zum Zitat Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Can J Surg. 2009;52(1):6–11.PubMed Kosashvili Y, Shasha N, Olschewski E, Safir O, White L, Gross A, et al. Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty. Can J Surg. 2009;52(1):6–11.PubMed
25.
Zurück zum Zitat Della Valle GA, Comba F, Taveras N, Salvati EA. The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop. 2008;32:289–94.CrossRef Della Valle GA, Comba F, Taveras N, Salvati EA. The utility and precision of analogue and digital preoperative planning for total hip arthroplasty. Int Orthop. 2008;32:289–94.CrossRef
Metadaten
Titel
Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system
verfasst von
Ari Bertz
Kari Indrekvam
Mohamed Ahmed
Erling Englund
Arkan S. Sayed-Noor
Publikationsdatum
01.10.2012
Verlag
Springer-Verlag
Erschienen in
Skeletal Radiology / Ausgabe 10/2012
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-012-1431-4

Weitere Artikel der Ausgabe 10/2012

Skeletal Radiology 10/2012 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.