Skip to main content
Erschienen in: Surgical and Radiologic Anatomy 5/2008

01.07.2008 | Original Article

An initial qualitative study of dual-energy CT in the knee ligaments

verfasst von: Cong Sun, Fan Miao, Xi-ming Wang, Tao Wang, Rui Ma, Dao-ping Wang, Cheng Liu

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 5/2008

Einloggen, um Zugang zu erhalten

Abstract

Objective

To study the clinical application of dual-energy CT (DECT) in the knee ligaments.

Methods

Twelve cases (24 knees) were scanned using dual-energy CT for the knee. Two- and three-dimensional images were used for display in all cases by means of multi-planar reformation (MPR) and volume rendering technique (VRT). All images were ranked by two radiologists according to the grade of knee ligament displayed, the definition of edge and attachment points of the knee ligament.

Results

The partial ligaments of 24 knees, such as the patellar ligament, fibular collateral ligament, anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) were clearly displayed; the tibial collateral ligament was not satisfactorily displayed. The transversal ligaments, such as lateral patellar retinaculum and medial patellar retinaculum, and the posterior ligament, such as oblique popliteal ligament could not be shown clearly.

Conclusion

The dual-energy CT is a new and valuable tool to qualitatively display the main ligaments of the knee.
Literatur
1.
Zurück zum Zitat Achenbach S, Ropers D, Kuettner A et al (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography: initial experience. Eur J Radiol 57(3):331–335PubMedCrossRef Achenbach S, Ropers D, Kuettner A et al (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography: initial experience. Eur J Radiol 57(3):331–335PubMedCrossRef
3.
Zurück zum Zitat Busse H, Thomas M, Seiwerts M et al (2008) In vivo glenohumeral analysis using 3D MRI models and a flexible software tool: feasibility and precision. J Magn Reson Imaging 27(1):162–170PubMedCrossRef Busse H, Thomas M, Seiwerts M et al (2008) In vivo glenohumeral analysis using 3D MRI models and a flexible software tool: feasibility and precision. J Magn Reson Imaging 27(1):162–170PubMedCrossRef
4.
Zurück zum Zitat Fayad LM, Rosenthal EH, Morrison WB et al (2008) Anterior cruciate ligament volume: analysis of gender differences. J Magn Reson Imaging 27(1):218–223PubMedCrossRef Fayad LM, Rosenthal EH, Morrison WB et al (2008) Anterior cruciate ligament volume: analysis of gender differences. J Magn Reson Imaging 27(1):218–223PubMedCrossRef
5.
Zurück zum Zitat Flohr TG, MeCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16(2):256–268PubMedCrossRef Flohr TG, MeCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16(2):256–268PubMedCrossRef
6.
Zurück zum Zitat Gold GE, Busse RF, Beehler C et al (2007) Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. Am J Roentgenol 188(5):1287–1293CrossRef Gold GE, Busse RF, Beehler C et al (2007) Isotropic MRI of the knee with 3D fast spin-echo extended echo-train acquisition (XETA): initial experience. Am J Roentgenol 188(5):1287–1293CrossRef
7.
Zurück zum Zitat Johnson TR, Krauss B, Sedlmair M et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17(6):1510–1517PubMedCrossRef Johnson TR, Krauss B, Sedlmair M et al (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17(6):1510–1517PubMedCrossRef
8.
Zurück zum Zitat Van de Berg BC, Lecouvet FE, Poilvache P et al (2002) Spiral CT arthrography of the postoperative knee. Semin Musculoskelet Radiol 6(1):47–55CrossRef Van de Berg BC, Lecouvet FE, Poilvache P et al (2002) Spiral CT arthrography of the postoperative knee. Semin Musculoskelet Radiol 6(1):47–55CrossRef
9.
Zurück zum Zitat Van de Berg BC, Lecouvet FE, Maldague B et al (2004) MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis. Eur Radiol 14:208–214CrossRef Van de Berg BC, Lecouvet FE, Maldague B et al (2004) MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis. Eur Radiol 14:208–214CrossRef
Metadaten
Titel
An initial qualitative study of dual-energy CT in the knee ligaments
verfasst von
Cong Sun
Fan Miao
Xi-ming Wang
Tao Wang
Rui Ma
Dao-ping Wang
Cheng Liu
Publikationsdatum
01.07.2008
Verlag
Springer-Verlag
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 5/2008
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-008-0349-y

Weitere Artikel der Ausgabe 5/2008

Surgical and Radiologic Anatomy 5/2008 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.