Skip to main content
Erschienen in: European Radiology 2/2004

01.02.2004 | Cardiac

Multidetector-row cardiac CT: diagnostic value of calcium scoring and CT coronary angiography in patients with symptomatic, but atypical, chest pain

verfasst von: Christopher Herzog, Martina Britten, Joern O. Balzer, M. G. Mack, Stefan Zangos, Hanns Ackermann, Volker Schaechinger, Stefan Schaller, Thomas Flohr, Thomas J. Vogl

Erschienen in: European Radiology | Ausgabe 2/2004

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to investigate the accuracy of multidetector-row cardiac CT (MDCT), calcium scoring (Ca-Sc), and MDCT coronary angiography (MD CTA) in the assessment of coronary atherosclerosis. Thirty-eight patients underwent invasive coronary angiography (CA) and MDCT (collimation 4×1 mm, pitch 1.5 mm, TI 500 ms, 120 kV, 300 mAs, and retrospective ECG-gating). Calcium scoring was calculated for the total coronary artery territory and for RCA, LCA, and LCX separately. The MD CTA served to assess the degree and the localization of stenoses. All findings were compared to invasive coronary angiography. Approximately 68.4% (390 of 570) of all coronary segments could be visualized by MDCT. Correlation coefficient for MD CTA and CA amounted to r=0.58, showing distinct differences for the individual segments. Proximal segments generally showed better correlation (range 0.81–0.77) than medial segments (range 0.91–0.20), distal segments (range 0.55–0.04), or side branches (range 0.76–0.00). Patients with hemodynamically relevant (>75%) stenoses were detected by MD CTA with 72.2% sensitivity (13 of 18) and 100% specificity (20 of 20). For Ca-Sc sensitivity ranged between 94.7% (17 of 18) and 66.7% (12 of 18), specificity between 20% (4 of 20) and 80% (16 of 20) respectively, depending on the prevailing cutoff value. Combination of both methods led to 83.3% sensitivity (15 of 18) and 100% specificity (20 of 20), reaching no level of significance as compared with Ca-Sc (p=0.73) or MD CTA (p=0.23) alone. Calcium scoring as a single method showed highest sensitivity in the detection of coronary atherosclerosis but at the expense of low specificity. In patients with no or moderate calcifications, combination with MD CTA helped to distinctly increase specificity and NPV
Literatur
1.
Zurück zum Zitat Wexler L, Brundage B, Crouse J, Detrano R, Fuster V, Maddahi J et al. (1996) Coronary artery calcification: pathophysiology, epidemiology, imaging methods, and clinical implications: a statement for health professionals from the American Heart Association. Circulation 94:1175–1192PubMed Wexler L, Brundage B, Crouse J, Detrano R, Fuster V, Maddahi J et al. (1996) Coronary artery calcification: pathophysiology, epidemiology, imaging methods, and clinical implications: a statement for health professionals from the American Heart Association. Circulation 94:1175–1192PubMed
2.
Zurück zum Zitat Becker CR, Schoepf UJ, Reiser MF (2001) Methods for quantification of coronary artery calcifications with electron-beam and conventional CT and pushing the spiral CT envelope: new cardiac applications. Int J Cardiovasc Imaging 17:203–211CrossRefPubMed Becker CR, Schoepf UJ, Reiser MF (2001) Methods for quantification of coronary artery calcifications with electron-beam and conventional CT and pushing the spiral CT envelope: new cardiac applications. Int J Cardiovasc Imaging 17:203–211CrossRefPubMed
3.
Zurück zum Zitat Becker CR, Knez A, Leber A, Treede H, Ohnesorge B, Schoepf UJ et al. (2002) Detection of coronary artery stenoses with multislice helical CT angiography. J Comput Assist Tomogr 26:750–755CrossRefPubMed Becker CR, Knez A, Leber A, Treede H, Ohnesorge B, Schoepf UJ et al. (2002) Detection of coronary artery stenoses with multislice helical CT angiography. J Comput Assist Tomogr 26:750–755CrossRefPubMed
4.
Zurück zum Zitat Fischbach R, Heindel W (2000) Detection and quantification of coronary calcification: an update. Fortschr Rontgenstr 172:407–414CrossRef Fischbach R, Heindel W (2000) Detection and quantification of coronary calcification: an update. Fortschr Rontgenstr 172:407–414CrossRef
5.
Zurück zum Zitat Hong C, Becker CR, Schoepf UJ, Ohnesorge B, Bruening R, Reiser M (2002) Coronary artery calcium: absolute quantification in non-enhanced and contrast-enhanced multi-detector row CT studies. Radiology 223:474–480PubMed Hong C, Becker CR, Schoepf UJ, Ohnesorge B, Bruening R, Reiser M (2002) Coronary artery calcium: absolute quantification in non-enhanced and contrast-enhanced multi-detector row CT studies. Radiology 223:474–480PubMed
6.
Zurück zum Zitat Kopp AF, Ohnesorge B, Becker C, Schroder S, Heuschmid M, Kuttner A et al. (2002) Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT. Radiology 225:113–119PubMed Kopp AF, Ohnesorge B, Becker C, Schroder S, Heuschmid M, Kuttner A et al. (2002) Reproducibility and accuracy of coronary calcium measurements with multi-detector row versus electron-beam CT. Radiology 225:113–119PubMed
7.
Zurück zum Zitat Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schroder S et al. (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed Ohnesorge B, Flohr T, Fischbach R, Kopp AF, Knez A, Schroder S et al. (2002) Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol 12:1532–1540CrossRefPubMed
8.
Zurück zum Zitat Stanford W, Thompson BH (1999) Imaging of coronary artery calcification: its importance in assessing atherosclerotic disease. Radiol Clin North Am 37:257–272PubMed Stanford W, Thompson BH (1999) Imaging of coronary artery calcification: its importance in assessing atherosclerotic disease. Radiol Clin North Am 37:257–272PubMed
9.
Zurück zum Zitat American College of Cardiology/American Heart Association (2000) Expert consensus document on electron-beam computed tomography for the diagnosis and prognosis of coronary artery diseaese. Circulation 102:126–140PubMed American College of Cardiology/American Heart Association (2000) Expert consensus document on electron-beam computed tomography for the diagnosis and prognosis of coronary artery diseaese. Circulation 102:126–140PubMed
10.
Zurück zum Zitat Bormann JL, Stanford W, Stenberg RG (1992) Ultrafast tomographic detection of coronary artery calcification as an indicator of stenosis. Am J Card Imaging 6:191–196 Bormann JL, Stanford W, Stenberg RG (1992) Ultrafast tomographic detection of coronary artery calcification as an indicator of stenosis. Am J Card Imaging 6:191–196
11.
Zurück zum Zitat Falk E (1983) Plaque rupture with severe pre-existing stenosis precipitating coronary thrombosis: characteristics of coronary atherosclerotic plaques underlying fatal occlusive thrombi. Br Heart J 50:127–134PubMed Falk E (1983) Plaque rupture with severe pre-existing stenosis precipitating coronary thrombosis: characteristics of coronary atherosclerotic plaques underlying fatal occlusive thrombi. Br Heart J 50:127–134PubMed
12.
Zurück zum Zitat Schmermund A, Baumgart D, Gorge G, Seibel R, Gronemeyer D, Ge J et al. (1997) Coronary artery calcium in acute coronary syndromes: a comparative study of electron-beam computed tomography, coronary angiography, and intracoronary ultrasound in survivors of acute myocardial infarction and unstable angina. Circulation 96:1461–1469PubMed Schmermund A, Baumgart D, Gorge G, Seibel R, Gronemeyer D, Ge J et al. (1997) Coronary artery calcium in acute coronary syndromes: a comparative study of electron-beam computed tomography, coronary angiography, and intracoronary ultrasound in survivors of acute myocardial infarction and unstable angina. Circulation 96:1461–1469PubMed
13.
Zurück zum Zitat Flohr T, Ohnesorge B (2001) Heart-rate-adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed Flohr T, Ohnesorge B (2001) Heart-rate-adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart. J Comput Assist Tomogr 25:907–923CrossRefPubMed
14.
Zurück zum Zitat Fuchs T, Krause J, Schaller S, Flohr T, Kalender WA (2000) Spiral interpolation algorithms for multislice spiral CT. Part II: Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system. IEEE Trans Med Imaging 19:835–847PubMed Fuchs T, Krause J, Schaller S, Flohr T, Kalender WA (2000) Spiral interpolation algorithms for multislice spiral CT. Part II: Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system. IEEE Trans Med Imaging 19:835–847PubMed
15.
Zurück zum Zitat Ohnesorge B, Flohr T, Becker C, Kopp AF, Schoepf UJ, Baum U et al. (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed Ohnesorge B, Flohr T, Becker C, Kopp AF, Schoepf UJ, Baum U et al. (2000) Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 217:564–571PubMed
16.
Zurück zum Zitat Kopp AF, Schroeder S, Baumbach A, Kuettner A, Georg C, Ohnesorge B et al. (2001) Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 11:1607–1611CrossRefPubMed Kopp AF, Schroeder S, Baumbach A, Kuettner A, Georg C, Ohnesorge B et al. (2001) Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 11:1607–1611CrossRefPubMed
17.
Zurück zum Zitat Becker CR, Knez A, Leber A, Hong C, Treede H, Wildhirt S et al. (2000) Initial experiences with multi-slice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels. Radiologe 40:118–122PubMed Becker CR, Knez A, Leber A, Hong C, Treede H, Wildhirt S et al. (2000) Initial experiences with multi-slice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels. Radiologe 40:118–122PubMed
18.
Zurück zum Zitat Vogl TJ, Abolmaali ND, Diebold T, Engelmann K, Ay M, Dogan S et al. (2002) Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 223:212–220PubMed Vogl TJ, Abolmaali ND, Diebold T, Engelmann K, Ay M, Dogan S et al. (2002) Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology 223:212–220PubMed
19.
Zurück zum Zitat Diamond GA, Forrester JS (1979) Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 300:1350–1358PubMed Diamond GA, Forrester JS (1979) Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 300:1350–1358PubMed
20.
Zurück zum Zitat Ohnesorge B, Flohr T, Becker C, Knez A, Kopp AF, Fukuda K et al. (2000) Cardiac imaging with rapid, retrospective ECG-synchronized multilevel spiral CT. Radiologe 40:111–117PubMed Ohnesorge B, Flohr T, Becker C, Knez A, Kopp AF, Fukuda K et al. (2000) Cardiac imaging with rapid, retrospective ECG-synchronized multilevel spiral CT. Radiologe 40:111–117PubMed
21.
Zurück zum Zitat Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackermann H, Dogan S et al. (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed Herzog C, Abolmaali N, Balzer JO, Baunach S, Ackermann H, Dogan S et al. (2002) Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed
22.
Zurück zum Zitat American College of Cardiology/American Heart Association (1991) Guidelines for cardiac catheterization and cardiac catheterization laboratories. American College of Cardiology/American Heart Association Ad Hoc Task Force on Cardiac Catheterization. J Am Coll Cardiol 18:1149–1182PubMed American College of Cardiology/American Heart Association (1991) Guidelines for cardiac catheterization and cardiac catheterization laboratories. American College of Cardiology/American Heart Association Ad Hoc Task Force on Cardiac Catheterization. J Am Coll Cardiol 18:1149–1182PubMed
23.
Zurück zum Zitat Bowker A (1948) A test for symmetry in contingency tables. J Am Stat Assoc 43:572–574 Bowker A (1948) A test for symmetry in contingency tables. J Am Stat Assoc 43:572–574
24.
Zurück zum Zitat Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832PubMed Agatston AS, Janowitz WR, Hildner FJ, Zusmer NR, Viamonte M, Detrano R (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832PubMed
25.
Zurück zum Zitat Rumberger JA, Brundage BH, Rader DJ, Kondos G (1999) Electron beam computed tomographic coronary calcium scanning: a review and guidelines for use in asymptomatic persons. Mayo Clin Proc 74:243–252PubMed Rumberger JA, Brundage BH, Rader DJ, Kondos G (1999) Electron beam computed tomographic coronary calcium scanning: a review and guidelines for use in asymptomatic persons. Mayo Clin Proc 74:243–252PubMed
26.
Zurück zum Zitat Becker CR, Knez A, Ohnesorge B, Schoepf UJ, Flohr T, Bruening R et al. (2000) Visualization and quantification of coronary calcifications with electron beam and spiral computed tomography. Eur Radiol 10:629–635CrossRefPubMed Becker CR, Knez A, Ohnesorge B, Schoepf UJ, Flohr T, Bruening R et al. (2000) Visualization and quantification of coronary calcifications with electron beam and spiral computed tomography. Eur Radiol 10:629–635CrossRefPubMed
27.
Zurück zum Zitat Becker CR, Kleffel T, Crispin A, Knez A, Young J, Schoepf UJ et al. (2001) Coronary artery calcium measurement: agreement of multirow detector and electron beam CT. Am J Roentgenol 176:1295–1298 Becker CR, Kleffel T, Crispin A, Knez A, Young J, Schoepf UJ et al. (2001) Coronary artery calcium measurement: agreement of multirow detector and electron beam CT. Am J Roentgenol 176:1295–1298
28.
Zurück zum Zitat Achenbach S, Daniel WG, Moshage W (2001) Recommendations for standardization of EBT and MSCT scanning. Herz 26:273–277PubMed Achenbach S, Daniel WG, Moshage W (2001) Recommendations for standardization of EBT and MSCT scanning. Herz 26:273–277PubMed
29.
Zurück zum Zitat Becker CR, Ohnesorge BM, Schoepf UJ, Reiser MF (2000) Current development of cardiac imaging with multidetector-row CT. Eur J Radiol 36:97–103CrossRefPubMed Becker CR, Ohnesorge BM, Schoepf UJ, Reiser MF (2000) Current development of cardiac imaging with multidetector-row CT. Eur J Radiol 36:97–103CrossRefPubMed
30.
Zurück zum Zitat Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ et al. (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603PubMed Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ et al. (2001) Coronary angiography with multi-slice computed tomography. Lancet 357:599–603PubMed
31.
Zurück zum Zitat Kopp AF, Schroeder S, Kuettner A (2000) Multidetector-row CT for non-invasive coronary angiography: results in 102 patients. Radiology 217:487PubMed Kopp AF, Schroeder S, Kuettner A (2000) Multidetector-row CT for non-invasive coronary angiography: results in 102 patients. Radiology 217:487PubMed
32.
Zurück zum Zitat Fischbach R, Wichter T, Juergens KU (2001) Multidetector-row spiral CT of the coronary arteries: comparison with coronary angiography. Fortschr Roentgenstr 173:26 Fischbach R, Wichter T, Juergens KU (2001) Multidetector-row spiral CT of the coronary arteries: comparison with coronary angiography. Fortschr Roentgenstr 173:26
33.
Zurück zum Zitat Jakobs TF, Becker CR, Wintersperger BJ, Herzog P, Ohnesorge B, Flohr T et al. (2002) CT angiography of the coronary arteries with a 16-row spiral tomograph: effect of spatial resolution on image quality. Radiologe 42:733–738 Jakobs TF, Becker CR, Wintersperger BJ, Herzog P, Ohnesorge B, Flohr T et al. (2002) CT angiography of the coronary arteries with a 16-row spiral tomograph: effect of spatial resolution on image quality. Radiologe 42:733–738
34.
Zurück zum Zitat Kopp AF, Heuschmid M, Claussen CD (2002) Multidetector helical CT of the liver for tumor detection and characterization. Eur Radiol 12:745–752CrossRefPubMed Kopp AF, Heuschmid M, Claussen CD (2002) Multidetector helical CT of the liver for tumor detection and characterization. Eur Radiol 12:745–752CrossRefPubMed
35.
Zurück zum Zitat Wintersperger BJ, Herzog P, Jakobs T, Reiser MF, Becker CR (2002) Initial experience with the clinical use of a 16-detector-row CT system. Crit Rev Comput Tomogr 43:283–316PubMed Wintersperger BJ, Herzog P, Jakobs T, Reiser MF, Becker CR (2002) Initial experience with the clinical use of a 16-detector-row CT system. Crit Rev Comput Tomogr 43:283–316PubMed
36.
Zurück zum Zitat Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed Ulzheimer S, Kalender WA (2003) Assessment of calcium scoring performance in cardiac computed tomography. Eur Radiol 13:484–497PubMed
Metadaten
Titel
Multidetector-row cardiac CT: diagnostic value of calcium scoring and CT coronary angiography in patients with symptomatic, but atypical, chest pain
verfasst von
Christopher Herzog
Martina Britten
Joern O. Balzer
M. G. Mack
Stefan Zangos
Hanns Ackermann
Volker Schaechinger
Stefan Schaller
Thomas Flohr
Thomas J. Vogl
Publikationsdatum
01.02.2004
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 2/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2197-9

Weitere Artikel der Ausgabe 2/2004

European Radiology 2/2004 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.