Skip to main content
Erschienen in: European Radiology 4/2011

01.04.2011 | Cardiac

Functional cardiac MR imaging with true fast imaging with steady-state free precession before and after intravenous injection of contrast medium: comparison of image quality and accuracy

verfasst von: Gabriele A. Krombach, Thorsten Plum, Ralf Koos, Rainer Hoffmann, Ertunc Altiok, Nils A. Krämer, Rolf W. Günther, Felix Schoth

Erschienen in: European Radiology | Ausgabe 4/2011

Einloggen, um Zugang zu erhalten

Abstract

Objective

To compare image quality and accuracy of left ventricular function of cine SSFP (steady-state free precession) images before and after injection of Gd-DTPA.

Methods

In 30 patients T1 times of LV blood and myocardium were measured before and after injection of 0.2 mmol/kg body weight Gd-DTPA. Signal intensity of myocardium and left ventricular blood were measured on SSFP images and the contrast calculated. In 20 additional patients short axis images completely covering the left ventricle were acquired before and after injection of Gd-DTPA and parameters of left ventricular function compared. Image quality and regional function were assessed using the 17-segment model.

Results

Image quality after injection of contrast medium did not significantly change compared with unenhanced images. Contrast between myocardium and LV blood decreased from 0.6 ± 0.01 to 0.4 ± 0.03 after injection while the T1 value of myocardium decreased from 1121 ± 21 ms to 389 ± 14 ms (blood 1413 ± 48 ms to 222 ± 8 ms). Assessment of regional and global left ventricular function revealed similar results before and after the injection of contrast medium.

Conclusion

Cine SSFP can be obtained after injection of contrast medium without loss of accuracy for regional and global LV ventricular function. This protocol can be used to decrease imaging time for thorough cardiac examination.
Literatur
1.
Zurück zum Zitat Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU (2001) Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 14:230–236PubMedCrossRef Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU (2001) Steady-state free precession magnetic resonance imaging of the heart: comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 14:230–236PubMedCrossRef
2.
Zurück zum Zitat Miller S, Simonetti OP, Carr J, Kramer U, Finn JP (2002) MR Imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters. Radiology 223:263–269PubMedCrossRef Miller S, Simonetti OP, Carr J, Kramer U, Finn JP (2002) MR Imaging of the heart with cine true fast imaging with steady-state precession: influence of spatial and temporal resolutions on left ventricular functional parameters. Radiology 223:263–269PubMedCrossRef
3.
Zurück zum Zitat Pennell DJ, Sechtem UP, Higgins CB, Manning WJ, Pohost GM, Rademakers FE, van Rossum AC, Shaw LJ, Yucel EK (2004) Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report. J Cardiovasc Magn Reson 6:727–765PubMedCrossRef Pennell DJ, Sechtem UP, Higgins CB, Manning WJ, Pohost GM, Rademakers FE, van Rossum AC, Shaw LJ, Yucel EK (2004) Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report. J Cardiovasc Magn Reson 6:727–765PubMedCrossRef
4.
Zurück zum Zitat Wu KC, Zerhouni EA, Judd RM, Lugo-Olivieri CH, Barouch LA, Schulman SP, Blumenthal RS, Lima JA (1998) Prognostic significance of microvascular obstruction by magnetic resonance imaging in patients with acute myocardial infarction. Circulation 97:765–772PubMed Wu KC, Zerhouni EA, Judd RM, Lugo-Olivieri CH, Barouch LA, Schulman SP, Blumenthal RS, Lima JA (1998) Prognostic significance of microvascular obstruction by magnetic resonance imaging in patients with acute myocardial infarction. Circulation 97:765–772PubMed
5.
Zurück zum Zitat Wu E, Judd RM, Vargas JD, Klocke FJ, Bonow RO, Kim RJ (2001) Visualisation of presence, location, and transmural extent of healed Q-wave and non-Q-wave myocardial infarction. Lancet 357:21–28PubMedCrossRef Wu E, Judd RM, Vargas JD, Klocke FJ, Bonow RO, Kim RJ (2001) Visualisation of presence, location, and transmural extent of healed Q-wave and non-Q-wave myocardial infarction. Lancet 357:21–28PubMedCrossRef
6.
Zurück zum Zitat Finn JP, Nael K, Deshpande V, Ratib O, Laub G (2006) Cardiac MR imaging: state of the technology. Radiology 241:338–354PubMedCrossRef Finn JP, Nael K, Deshpande V, Ratib O, Laub G (2006) Cardiac MR imaging: state of the technology. Radiology 241:338–354PubMedCrossRef
7.
Zurück zum Zitat Isbell DC, Kramer CM (2006) Magnetic resonance for the assessment of myocardial viability. Curr Opin Cardiol 21:469–472PubMedCrossRef Isbell DC, Kramer CM (2006) Magnetic resonance for the assessment of myocardial viability. Curr Opin Cardiol 21:469–472PubMedCrossRef
8.
Zurück zum Zitat Cho JR, Park S, Choi BW, Kang SM, Ha JW, Chung N, Choe KO, Cho SY, Rim SJ (2010) Delayed enhancement magnetic resonance imaging is a significant prognostic factor in patients with non-ischemic cardiomyopathy. Circ J 74:476–483PubMedCrossRef Cho JR, Park S, Choi BW, Kang SM, Ha JW, Chung N, Choe KO, Cho SY, Rim SJ (2010) Delayed enhancement magnetic resonance imaging is a significant prognostic factor in patients with non-ischemic cardiomyopathy. Circ J 74:476–483PubMedCrossRef
9.
Zurück zum Zitat Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU (2003) Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 17:323–329PubMedCrossRef Alfakih K, Plein S, Thiele H, Jones T, Ridgway JP, Sivananthan MU (2003) Normal human left and right ventricular dimensions for MRI as assessed by turbo gradient echo and steady-state free precession imaging sequences. J Magn Reson Imaging 17:323–329PubMedCrossRef
10.
Zurück zum Zitat Kim RJ, Fieno DS, Parrish TB, Harris K, Chen EL, Simonetti O, Bundy J, Finn JP, Klocke FJ, Judd RM (1999) Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. Circulation 100:1992–2002PubMed Kim RJ, Fieno DS, Parrish TB, Harris K, Chen EL, Simonetti O, Bundy J, Finn JP, Klocke FJ, Judd RM (1999) Relationship of MRI delayed contrast enhancement to irreversible injury, infarct age, and contractile function. Circulation 100:1992–2002PubMed
11.
Zurück zum Zitat Look D, Locker D (1970) Time saving measurement of NMR and EPR relaxation times. Rev Sci Instrum 41:250–251CrossRef Look D, Locker D (1970) Time saving measurement of NMR and EPR relaxation times. Rev Sci Instrum 41:250–251CrossRef
12.
Zurück zum Zitat Flacke S, Allen JS, Chia JM, Wible JH, Periasamy MP, Adams MD, Adzamli IK, Lorenz CH (2003) Characterization of viable and nonviable myocardium at MR imaging: comparison of gadolinium-based extracellular and blood pool contrast materials versus manganese-based contrast materials in a rat myocardial infarction model. Radiology 226:731–738PubMedCrossRef Flacke S, Allen JS, Chia JM, Wible JH, Periasamy MP, Adams MD, Adzamli IK, Lorenz CH (2003) Characterization of viable and nonviable myocardium at MR imaging: comparison of gadolinium-based extracellular and blood pool contrast materials versus manganese-based contrast materials in a rat myocardial infarction model. Radiology 226:731–738PubMedCrossRef
13.
Zurück zum Zitat Wagenseil JE, Johansson LO, Lorenz CH (1999) Characterization of t1 relaxation and blood-myocardial contrast enhancement of NC100150 injection in cardiac MRI. J Magn Reson Imaging 10:784–789PubMedCrossRef Wagenseil JE, Johansson LO, Lorenz CH (1999) Characterization of t1 relaxation and blood-myocardial contrast enhancement of NC100150 injection in cardiac MRI. J Magn Reson Imaging 10:784–789PubMedCrossRef
14.
Zurück zum Zitat Flacke SJ, Fischer SE, Lorenz CH (2001) Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: normal distribution and elevation in acute and chronic infarction. Radiology 218:703–710PubMed Flacke SJ, Fischer SE, Lorenz CH (2001) Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: normal distribution and elevation in acute and chronic infarction. Radiology 218:703–710PubMed
15.
Zurück zum Zitat Krombach GA, Pfeffer JG, Kinzel S, Katoh M, Gunther RW, Buecker A (2005) MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs. Radiology 235:487–494PubMedCrossRef Krombach GA, Pfeffer JG, Kinzel S, Katoh M, Gunther RW, Buecker A (2005) MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs. Radiology 235:487–494PubMedCrossRef
16.
Zurück zum Zitat Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542PubMedCrossRef Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542PubMedCrossRef
17.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMed
18.
Zurück zum Zitat Haacke EM, Frahm J (1991) A guide to understanding key aspects of fast gradient-echo imaging. J Magn Reson Imaging 1:621–624PubMedCrossRef Haacke EM, Frahm J (1991) A guide to understanding key aspects of fast gradient-echo imaging. J Magn Reson Imaging 1:621–624PubMedCrossRef
19.
Zurück zum Zitat Scheffler K, Lehnhardt S (2003) Principles and applications of balanced SSFP techniques. Eur Radiol 13:2409–2418PubMedCrossRef Scheffler K, Lehnhardt S (2003) Principles and applications of balanced SSFP techniques. Eur Radiol 13:2409–2418PubMedCrossRef
20.
Zurück zum Zitat Sharma P, Socolow J, Patel S, Pettigrew RI, Oshinski JN (2006) Effect of Gd-DTPA-BMA on blood and myocardial T1 at 1.5T and 3T in humans. J Magn Reson Imaging 23:323–330PubMedCrossRef Sharma P, Socolow J, Patel S, Pettigrew RI, Oshinski JN (2006) Effect of Gd-DTPA-BMA on blood and myocardial T1 at 1.5T and 3T in humans. J Magn Reson Imaging 23:323–330PubMedCrossRef
21.
Zurück zum Zitat Stillman AE, Wilke N, Jerosch-Herold M (1997) Use of an intravascular T1 contrast agent to improve MR cine myocardial-blood pool definition in man. J Magn Reson Imaging 7:765–767PubMedCrossRef Stillman AE, Wilke N, Jerosch-Herold M (1997) Use of an intravascular T1 contrast agent to improve MR cine myocardial-blood pool definition in man. J Magn Reson Imaging 7:765–767PubMedCrossRef
22.
Zurück zum Zitat Hamdan A, Kelle S, Schnackenburg B, Wellnhofer E, Fleck E, Nagel E (2008) Single-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla. J Magn Reson Imaging 27:1028–1036PubMedCrossRef Hamdan A, Kelle S, Schnackenburg B, Wellnhofer E, Fleck E, Nagel E (2008) Single-breathhold four-dimensional assessment of left ventricular volumes and function using k-t BLAST after application of extracellular contrast agent at 3 Tesla. J Magn Reson Imaging 27:1028–1036PubMedCrossRef
23.
Zurück zum Zitat Hamdan A, Kelle S, Schnackenburg B, Fleck E, Nagel E (2007) Improved quantitative assessment of left ventricular volumes using TGrE approach after application of extracellular contrast agent at 3 Tesla. J Cardiovasc Magn Reson 9:845–853PubMedCrossRef Hamdan A, Kelle S, Schnackenburg B, Fleck E, Nagel E (2007) Improved quantitative assessment of left ventricular volumes using TGrE approach after application of extracellular contrast agent at 3 Tesla. J Cardiovasc Magn Reson 9:845–853PubMedCrossRef
24.
Zurück zum Zitat Kelle S, Hamdan A, Schnackenburg B, Kohler U, Klein C, Nagel E, Fleck E (2008) Dobutamine stress cardiovascular magnetic resonance at 3 Tesla. J Cardiovasc Magn Reson 10:44PubMedCrossRef Kelle S, Hamdan A, Schnackenburg B, Kohler U, Klein C, Nagel E, Fleck E (2008) Dobutamine stress cardiovascular magnetic resonance at 3 Tesla. J Cardiovasc Magn Reson 10:44PubMedCrossRef
25.
Zurück zum Zitat Kirsch JE (1991) Basic principles of magnetic resonance contrast agents. Top Magn Reson Imaging 3:1–18PubMedCrossRef Kirsch JE (1991) Basic principles of magnetic resonance contrast agents. Top Magn Reson Imaging 3:1–18PubMedCrossRef
Metadaten
Titel
Functional cardiac MR imaging with true fast imaging with steady-state free precession before and after intravenous injection of contrast medium: comparison of image quality and accuracy
verfasst von
Gabriele A. Krombach
Thorsten Plum
Ralf Koos
Rainer Hoffmann
Ertunc Altiok
Nils A. Krämer
Rolf W. Günther
Felix Schoth
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 4/2011
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-010-1969-2

Weitere Artikel der Ausgabe 4/2011

European Radiology 4/2011 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.