Patient dose reference levels in surgery: a multicenter study

verfasst von: J. Greffier, C. Etard, O. Mares, F. Pereira, D. Defez, C. Duverger, P. Branchereau, J. P. Beregi, R. Coulomb, A. Larbi

Erschienen in: European Radiology | Ausgabe 2/2019

Einloggen, um Zugang zu erhalten

Abstract

Objective

To assess diagnostic reference levels (DRLs) in surgery for the most frequent procedures as required by the European Directive 2013/59/Euratom.

Methods

A survey was conducted in six centers. Eight orthopedic, urology and gastrointestinal surgical procedures were analyzed. Kerma area product (KAP) and fluoroscopy time (FT) were recorded for 50 patients (except for elbow: 30 patients) per procedure and per center from September 2016 to September 2017. DRLs were calculated as the 3rd quartiles of the distributions. For shoulder surgery, DRLs were defined according to the complexity of the procedure. For hand/wrist and foot/ankle surgery, DRLs were defined according to the technology (conventional C-arm vs. mini-C-arm).

Results

Results of 1870 procedures were retrieved. DRLs were calculated for the two dosimetric indicators and the eight procedures. DRLs were 2130 mGy.cm2 and 1.4 min for proximal femoral intramedullary nail, 1185 mGy.cm2 and 0.9 min for laparoscopic cholecystectomy and 2195 mGy.cm2 and 1.0 min for double-J (pigtail) ureteral catheter insertion. For shoulder surgery, KAP and FT were significantly higher (p < 0.05) for intramedullary procedures compared to extramedullary procedures. For hand/wrist and foot/ankle surgery, the KAPs were significantly higher (p < 0.05) with conventional C-arm compared to mini-C-arm, but FTs were not significantly different (p: not significant).

Conclusion

This study reports DRLs in surgery based on a multicentric survey.

Key Points

• Delivered dose in surgery depends on procedure, practice and patient.
• Diagnostic reference levels (DRLs) are proposed for eight surgical procedures.
• DRLs are useful to benchmark practices and optimize protocols.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Rehani MM, Ciraj-Bjelac O, Vañó E et al (2010) ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40:1–102CrossRefPubMed Rehani MM, Ciraj-Bjelac O, Vañó E et al (2010) ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department. Ann ICRP 40:1–102CrossRefPubMed
2.
Zurück zum Zitat International Commission on Radiological protection (2007) The 2007 Recommendations of the International Commission on Radiological Protection. Publication 103. Ann ICRP 37:1–332 International Commission on Radiological protection (2007) The 2007 Recommendations of the International Commission on Radiological Protection. Publication 103. Ann ICRP 37:1–332
3.
Zurück zum Zitat Harding K, Thomson WH (1997) Radiological protection and safety in medicine - ICRP 73. Eur J Nucl Med 24:1207–1209PubMed Harding K, Thomson WH (1997) Radiological protection and safety in medicine - ICRP 73. Eur J Nucl Med 24:1207–1209PubMed
5.
Zurück zum Zitat National Council on Radiation Protection and Measurements (2012) Reference levels and achievable doses in medical and dental imaging: recommendations for the United States. NCRP report No. 172 National Council on Radiation Protection and Measurements (2012) Reference levels and achievable doses in medical and dental imaging: recommendations for the United States. NCRP report No. 172
6.
Zurück zum Zitat National Council on Radiation Protection and Measurements (2010) Radiation dose management for fluoroscopically-guided interventional medical procedures. NCRP report No. 168. National Council on Radiation Protection and Measurements (2010) Radiation dose management for fluoroscopically-guided interventional medical procedures. NCRP report No. 168.
7.
Zurück zum Zitat Office fédéral de la santé publique (2008) Confédération suisse. Niveaux de référence diagnostiques (NRD) en radiologie interventionnelle. Notice R-06-05 Office fédéral de la santé publique (2008) Confédération suisse. Niveaux de référence diagnostiques (NRD) en radiologie interventionnelle. Notice R-06-05
8.
Zurück zum Zitat International Commission on Radiological protection (2007) Radiation protection in medicine. Publication 105. Ann ICRP 37. Pergamon, Oxford International Commission on Radiological protection (2007) Radiation protection in medicine. Publication 105. Ann ICRP 37. Pergamon, Oxford
9.
Zurück zum Zitat Official Journal of the European Union (2013) Council Directive 2013/59/EURATOM of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionizing radiation, and repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom Official Journal of the European Union (2013) Council Directive 2013/59/EURATOM of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionizing radiation, and repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom
10.
Zurück zum Zitat Vañó E, Miller DL, Martin CJ et al (2017) ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Ann ICRP 46:1–144CrossRefPubMed Vañó E, Miller DL, Martin CJ et al (2017) ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Ann ICRP 46:1–144CrossRefPubMed
11.
Zurück zum Zitat Etard C, Bigand E, Salvat C et al (2017) Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France. Eur Radiol 27:4281–4290CrossRefPubMed Etard C, Bigand E, Salvat C et al (2017) Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France. Eur Radiol 27:4281–4290CrossRefPubMed
13.
Zurück zum Zitat Roux A, Bronsard N, Blanchet N, de Peretti F (2011) Can fluoroscopy radiation exposure be measured in minimally invasive trauma surgery? Revue de chirurgie orthopédique et traumatologique 97:644–651CrossRef Roux A, Bronsard N, Blanchet N, de Peretti F (2011) Can fluoroscopy radiation exposure be measured in minimally invasive trauma surgery? Revue de chirurgie orthopédique et traumatologique 97:644–651CrossRef
14.
Zurück zum Zitat Hardman J, Elvey M, Shah N, Simson N, Patel S, Anakwe R (2015) Defining reference levels for intra-operative radiation exposure in orthopaedic trauma: A retrospective multicentre study. Injury 46:2457–2460CrossRefPubMed Hardman J, Elvey M, Shah N, Simson N, Patel S, Anakwe R (2015) Defining reference levels for intra-operative radiation exposure in orthopaedic trauma: A retrospective multicentre study. Injury 46:2457–2460CrossRefPubMed
15.
Zurück zum Zitat Lee YS, Lee HK, Cho JH, Kim HG (2015) Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm). J Res Med Sci 20:7–12PubMedPubMedCentral Lee YS, Lee HK, Cho JH, Kim HG (2015) Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm). J Res Med Sci 20:7–12PubMedPubMedCentral
16.
Zurück zum Zitat Pillai A, Jain M (2004) Dose area product measurement in orthopaedic trauma. An attempt at establishing a local diagnostic reference level. Radiography (Lond) 10:103–107CrossRef Pillai A, Jain M (2004) Dose area product measurement in orthopaedic trauma. An attempt at establishing a local diagnostic reference level. Radiography (Lond) 10:103–107CrossRef
17.
Zurück zum Zitat Miller DL, Kwon D, Bonavia GH (2009) Reference levels for patient radiation doses in interventional radiology: proposed initial values for U. S. practice. Radiology 253:753–764CrossRefPubMedPubMedCentral Miller DL, Kwon D, Bonavia GH (2009) Reference levels for patient radiation doses in interventional radiology: proposed initial values for U. S. practice. Radiology 253:753–764CrossRefPubMedPubMedCentral
Metadaten
Titel
Patient dose reference levels in surgery: a multicenter study
verfasst von
J. Greffier
C. Etard
O. Mares
F. Pereira
D. Defez
C. Duverger
P. Branchereau
J. P. Beregi
R. Coulomb
A. Larbi
Publikationsdatum
01.08.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 2/2019
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5600-2

Weitere Artikel der Ausgabe 2/2019

European Radiology 2/2019 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.