Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 1/2014

01.02.2014 | Original Research

Closed loop mechanical ventilation

verfasst von: Marc Wysocki, Philippe Jouvet, Samir Jaber

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

Mechanical ventilation is a sophisticated technique with very narrow therapeutic ranges i.e. highly efficient and able to keep alive the most severe patients, but with considerable side effects and unwanted complications if not properly and timely used. Computerized protocols, closed loop systems, decision support, all terms which need to be defined, may help making mechanical ventilation safer and more efficient. The present paper will provide a short overview on technical and engineering considerations regarding closed loop controlled ventilation as well as tangible clinical evidences supporting the previous statement.
Literatur
2.
Zurück zum Zitat Auriant I, Reignier J, Pibarot ML, Bachat S, Tenaillon A, Raphael JC. Critical incidents related to invasive mechanical ventilation in the ICU: preliminary descriptive study. Intensive Care Med. 2002;28(4):452–8. doi:10.1007/s00134-002-1251-4.PubMedCrossRef Auriant I, Reignier J, Pibarot ML, Bachat S, Tenaillon A, Raphael JC. Critical incidents related to invasive mechanical ventilation in the ICU: preliminary descriptive study. Intensive Care Med. 2002;28(4):452–8. doi:10.​1007/​s00134-002-1251-4.PubMedCrossRef
3.
Zurück zum Zitat Randolph AG, Wypij D, Venkataraman ST, Hanson JH, Gedeit RG, Meert KL, Luckett PM, Forbes P, Lilley M, Thompson J, Cheifetz IM, Hibberd P, Wetzel R, Cox PN, Arnold JH. Effect of mechanical ventilator weaning protocols on respiratory outcomes in infants and children: a randomized controlled trial. JAMA. 2002;288(20):2561–8.PubMedCrossRef Randolph AG, Wypij D, Venkataraman ST, Hanson JH, Gedeit RG, Meert KL, Luckett PM, Forbes P, Lilley M, Thompson J, Cheifetz IM, Hibberd P, Wetzel R, Cox PN, Arnold JH. Effect of mechanical ventilator weaning protocols on respiratory outcomes in infants and children: a randomized controlled trial. JAMA. 2002;288(20):2561–8.PubMedCrossRef
5.
Zurück zum Zitat Leone M, Ragonnet B, Alonso S, Allaouchiche B, Constantin JM, Jaber S, Martin C, Fabbro-Peray P, Lefrant JY. Variable compliance with clinical practice guidelines identified in a 1-day audit at 66 French adult intensive care units. Crit Care Med. 2012;40(12):3189–95. doi:10.1097/CCM.0b013e31826571f2.PubMedCrossRef Leone M, Ragonnet B, Alonso S, Allaouchiche B, Constantin JM, Jaber S, Martin C, Fabbro-Peray P, Lefrant JY. Variable compliance with clinical practice guidelines identified in a 1-day audit at 66 French adult intensive care units. Crit Care Med. 2012;40(12):3189–95. doi:10.​1097/​CCM.​0b013e31826571f2​.PubMedCrossRef
6.
Zurück zum Zitat Santschi M, Jouvet P, Leclerc F, Gauvin F, Newth CJ, Carroll CL, Flori H, Tasker RC, Rimensberger PC, Randolph AG. Acute lung injury in children: therapeutic practice and feasibility of international clinical trials. Pediatr Crit Care Med. 2010;11(6):681–9. doi:10.1097/PCC.0b013e3181d904c0.PubMedCrossRef Santschi M, Jouvet P, Leclerc F, Gauvin F, Newth CJ, Carroll CL, Flori H, Tasker RC, Rimensberger PC, Randolph AG. Acute lung injury in children: therapeutic practice and feasibility of international clinical trials. Pediatr Crit Care Med. 2010;11(6):681–9. doi:10.​1097/​PCC.​0b013e3181d904c0​.PubMedCrossRef
7.
Zurück zum Zitat Khemani RG, Sward K, Morris A, Dean JM, Newth CJ. Variability in usual care mechanical ventilation for pediatric acute lung injury: the potential benefit of a lung protective computer protocol. Intensive Care Med. 2011;. doi:10.1007/s00134-011-2367-1.PubMedCentralPubMed Khemani RG, Sward K, Morris A, Dean JM, Newth CJ. Variability in usual care mechanical ventilation for pediatric acute lung injury: the potential benefit of a lung protective computer protocol. Intensive Care Med. 2011;. doi:10.​1007/​s00134-011-2367-1.PubMedCentralPubMed
8.
Zurück zum Zitat Rubenfeld GD. Implementing effective ventilator practice at the bedside. Curr Opin Crit Care. 2004;10(1):33–9.PubMedCrossRef Rubenfeld GD. Implementing effective ventilator practice at the bedside. Curr Opin Crit Care. 2004;10(1):33–9.PubMedCrossRef
9.
Zurück zum Zitat Morris AH. Developing and implementing computerized protocols for standardization of clinical decisions. Ann Intern Med. 2000;132(5):373–83.PubMedCrossRef Morris AH. Developing and implementing computerized protocols for standardization of clinical decisions. Ann Intern Med. 2000;132(5):373–83.PubMedCrossRef
10.
Zurück zum Zitat Rees SE. The Intelligent Ventilator (INVENT) project: the role of mathematical models in translating physiological knowledge into clinical practice. Comput Methods Program Biomed. 2011;104(Suppl 1):S1–29. doi:10.1016/s0169-2607(11)00307-5.CrossRef Rees SE. The Intelligent Ventilator (INVENT) project: the role of mathematical models in translating physiological knowledge into clinical practice. Comput Methods Program Biomed. 2011;104(Suppl 1):S1–29. doi:10.​1016/​s0169-2607(11)00307-5.CrossRef
15.
Zurück zum Zitat Lellouche F, Brochard L. Advanced closed loops during mechanical ventilation (PAV, NAVA, ASV, SmartCare). Best Pract Res Clin Anaesthesiol. 2009;23(1):81–93.PubMedCrossRef Lellouche F, Brochard L. Advanced closed loops during mechanical ventilation (PAV, NAVA, ASV, SmartCare). Best Pract Res Clin Anaesthesiol. 2009;23(1):81–93.PubMedCrossRef
16.
Zurück zum Zitat Miller G. The magical number seven plus or minus two: some limits on our capacity for processing information. Psychol Rev. 1956;63:81–97.PubMedCrossRef Miller G. The magical number seven plus or minus two: some limits on our capacity for processing information. Psychol Rev. 1956;63:81–97.PubMedCrossRef
18.
Zurück zum Zitat Lellouche F, Bouchard PA, Simard S, L’Her E, Wysocki M. Evaluation of fully automated ventilation: a randomized controlled study in post-cardiac surgery patients. Intensive Care Med. 2013;39(3):463–471. Lellouche F, Bouchard PA, Simard S, L’Her E, Wysocki M. Evaluation of fully automated ventilation: a randomized controlled study in post-cardiac surgery patients. Intensive Care Med. 2013;39(3):463–471.
19.
Zurück zum Zitat Esteban A, Ferguson ND, Meade MO, Frutos-Vivar F, Apezteguia C, Brochard L, Raymondos K, Nin N, Hurtado J, Tomicic V, Gonzalez M, Elizalde J, Nightingale P, Abroug F, Pelosi P, Arabi Y, Moreno R, Jibaja M, D’Empaire G, Sandi F, Matamis D, Montanez AM, Anzueto A. Evolution of mechanical ventilation in response to clinical research. Am J Respir Crit Care Med. 2008;177(2):170–7. doi:10.1164/rccm.200706-893OC.PubMedCrossRef Esteban A, Ferguson ND, Meade MO, Frutos-Vivar F, Apezteguia C, Brochard L, Raymondos K, Nin N, Hurtado J, Tomicic V, Gonzalez M, Elizalde J, Nightingale P, Abroug F, Pelosi P, Arabi Y, Moreno R, Jibaja M, D’Empaire G, Sandi F, Matamis D, Montanez AM, Anzueto A. Evolution of mechanical ventilation in response to clinical research. Am J Respir Crit Care Med. 2008;177(2):170–7. doi:10.​1164/​rccm.​200706-893OC.PubMedCrossRef
20.
Zurück zum Zitat Gnaiger E (2008) Polarographic oxygen sensors, the oxygraph and high-resolution respirometry to assess mitochondrial function. In: Dykens JA, Will Y (eds) Mitochondrial dysfunction in drug-induced toxicity. Wiley, New Jersey, pp 327–352 Gnaiger E (2008) Polarographic oxygen sensors, the oxygraph and high-resolution respirometry to assess mitochondrial function. In: Dykens JA, Will Y (eds) Mitochondrial dysfunction in drug-induced toxicity. Wiley, New Jersey, pp 327–352
21.
Zurück zum Zitat Claure N, Bancalari E, D’Ugard C, Nelin L, Stein M, Ramanathan R, Hernandez R, Donn SM, Becker M, Bachman T. Multicenter crossover study of automated control of inspired oxygen in ventilated preterm infants. Pediatrics. 2011;127(1):e76–83. doi:10.1542/peds.2010-0939.PubMedCrossRef Claure N, Bancalari E, D’Ugard C, Nelin L, Stein M, Ramanathan R, Hernandez R, Donn SM, Becker M, Bachman T. Multicenter crossover study of automated control of inspired oxygen in ventilated preterm infants. Pediatrics. 2011;127(1):e76–83. doi:10.​1542/​peds.​2010-0939.PubMedCrossRef
22.
Zurück zum Zitat Jouvet P, Eddington A, Payen V, Bordessoule A, Emeriaud G, Lopez Gasco R, Wysocki M. A pilot prospective study on closed loop controlled ventilation and oxygenation in ventilated children during the weaning phase. Crit Care. 2012;16(3):R85. Jouvet P, Eddington A, Payen V, Bordessoule A, Emeriaud G, Lopez Gasco R, Wysocki M. A pilot prospective study on closed loop controlled ventilation and oxygenation in ventilated children during the weaning phase. Crit Care. 2012;16(3):R85.
23.
Zurück zum Zitat Olliver S, Davis GM, Hatzakis GE. Weaning infants with respiratory syncytial virus from mechanical ventilation through a fuzzy-logic controller. In: AMIA annual symposium proceedings/AMIA symposium. 2003. p. 499–503. Olliver S, Davis GM, Hatzakis GE. Weaning infants with respiratory syncytial virus from mechanical ventilation through a fuzzy-logic controller. In: AMIA annual symposium proceedings/AMIA symposium. 2003. p. 499–503.
25.
26.
Zurück zum Zitat Saxton GA Jr, Myers G. A servomechanism for automatic regulation of pulmonary ventilation. J Appl Physiol. 1957;11(2):326–8.PubMed Saxton GA Jr, Myers G. A servomechanism for automatic regulation of pulmonary ventilation. J Appl Physiol. 1957;11(2):326–8.PubMed
27.
Zurück zum Zitat Beran AV, Taylor WF, Ackerman BD, Sperling DR, Strauss J. An automatic oxygen control system for infants. Pediatrics. 1971;48(2):315–8.PubMed Beran AV, Taylor WF, Ackerman BD, Sperling DR, Strauss J. An automatic oxygen control system for infants. Pediatrics. 1971;48(2):315–8.PubMed
28.
Zurück zum Zitat Beddis IR, Collins P, Levy NM, Godfrey S, Silverman M. New technique for servo-control of arterial oxygen tension in preterm infants. Arch Dis Child. 1979;54(4):278–80.PubMedCrossRef Beddis IR, Collins P, Levy NM, Godfrey S, Silverman M. New technique for servo-control of arterial oxygen tension in preterm infants. Arch Dis Child. 1979;54(4):278–80.PubMedCrossRef
29.
Zurück zum Zitat Dugdale RE, Cameron RG, Lealman GT. Closed-loop control of the partial pressure of arterial oxygen in neonates. Clin Phys Physiol Meas. 1988;9(4):291–305.PubMedCrossRef Dugdale RE, Cameron RG, Lealman GT. Closed-loop control of the partial pressure of arterial oxygen in neonates. Clin Phys Physiol Meas. 1988;9(4):291–305.PubMedCrossRef
30.
Zurück zum Zitat Urschitz MS, Horn W, Seyfang A, Hallenberger A, Herberts T, Miksch S, Popow C, Muller-Hansen I, Poets CF. Automatic control of the inspired oxygen fraction in preterm infants: a randomized crossover trial. Am J Respir Crit Care Med. 2004;170(10):1095–100. doi:10.1164/rccm.200407-929OC.PubMedCrossRef Urschitz MS, Horn W, Seyfang A, Hallenberger A, Herberts T, Miksch S, Popow C, Muller-Hansen I, Poets CF. Automatic control of the inspired oxygen fraction in preterm infants: a randomized crossover trial. Am J Respir Crit Care Med. 2004;170(10):1095–100. doi:10.​1164/​rccm.​200407-929OC.PubMedCrossRef
31.
Zurück zum Zitat Claure N, Gerhardt T, Everett R, Musante G, Herrera C, Bancalari E. Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia. Pediatrics. 2001;107(5):1120–4.PubMedCrossRef Claure N, Gerhardt T, Everett R, Musante G, Herrera C, Bancalari E. Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia. Pediatrics. 2001;107(5):1120–4.PubMedCrossRef
34.
Zurück zum Zitat Ely EW, Baker AM, Dunagan DP, Burke HL, Smith AC, Kelly PT, Johnson MM, Browder RW, Bowton DL, Haponik EF. Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously. N Engl J Med. 1996;335(25):1864–9. doi:10.1056/nejm199612193352502.PubMedCrossRef Ely EW, Baker AM, Dunagan DP, Burke HL, Smith AC, Kelly PT, Johnson MM, Browder RW, Bowton DL, Haponik EF. Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously. N Engl J Med. 1996;335(25):1864–9. doi:10.​1056/​nejm199612193352​502.PubMedCrossRef
35.
Zurück zum Zitat Jouvet P, Payen V, Gauvin F, Emeriaud G, lacroix J. Weaning children from mechanical ventilation with a computer-driven protocol: a pilot trial. Intensive Care Med. 2013 [Epub ahead of print]. doi:10.1007/s00134-013-2837-8 Jouvet P, Payen V, Gauvin F, Emeriaud G, lacroix J. Weaning children from mechanical ventilation with a computer-driven protocol: a pilot trial. Intensive Care Med. 2013 [Epub ahead of print]. doi:10.​1007/​s00134-013-2837-8
36.
Zurück zum Zitat Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, Cabello B, Bouadma L, Rodriguez P, Maggiore S, Reynaert M, Mersmann S, Brochard L. A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med. 2006;174(8):894–900. doi:10.1164/rccm.200511-1780OC.PubMedCrossRef Lellouche F, Mancebo J, Jolliet P, Roeseler J, Schortgen F, Dojat M, Cabello B, Bouadma L, Rodriguez P, Maggiore S, Reynaert M, Mersmann S, Brochard L. A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med. 2006;174(8):894–900. doi:10.​1164/​rccm.​200511-1780OC.PubMedCrossRef
37.
Zurück zum Zitat Rose L, Presneill JJ, Johnston L, Cade JF. A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med. 2008;34(10):1788–95. doi:10.1007/s00134-008-1179-4.PubMedCrossRef Rose L, Presneill JJ, Johnston L, Cade JF. A randomised, controlled trial of conventional versus automated weaning from mechanical ventilation using SmartCare/PS. Intensive Care Med. 2008;34(10):1788–95. doi:10.​1007/​s00134-008-1179-4.PubMedCrossRef
38.
Zurück zum Zitat Schadler D, Engel C, Elke G, Pulletz S, Haake N, Frerichs I, Zick G, Scholz J, Weiler N. Automatic control of pressure support for ventilator weaning in surgical intensive care patients. Am J Respir Crit Care Med. 2012;185(6):637–44. doi:10.1164/rccm.201106-1127OC.PubMedCrossRef Schadler D, Engel C, Elke G, Pulletz S, Haake N, Frerichs I, Zick G, Scholz J, Weiler N. Automatic control of pressure support for ventilator weaning in surgical intensive care patients. Am J Respir Crit Care Med. 2012;185(6):637–44. doi:10.​1164/​rccm.​201106-1127OC.PubMedCrossRef
40.
Zurück zum Zitat Tassaux D, Dalmas E, Gratadour P, Jolliet P. Patient-ventilator interactions during partial ventilatory support: a preliminary study comparing the effects of adaptive support ventilation with synchronized intermittent mandatory ventilation plus inspiratory pressure support. Crit Care Med. 2002;30(4):801–7.PubMedCrossRef Tassaux D, Dalmas E, Gratadour P, Jolliet P. Patient-ventilator interactions during partial ventilatory support: a preliminary study comparing the effects of adaptive support ventilation with synchronized intermittent mandatory ventilation plus inspiratory pressure support. Crit Care Med. 2002;30(4):801–7.PubMedCrossRef
41.
Zurück zum Zitat Clavieras N, Wysocki M, Coisel Y, Galia F, Conseil M, Chanques G, Jung B, Arnal JM, Matecki S, Jaber S. Prospective randomized crossover study comparing a new-full closed loop control solution and pressure support ventilation during weaning from mechanical ventilation. Anesthesiology. 2013 (in press). Clavieras N, Wysocki M, Coisel Y, Galia F, Conseil M, Chanques G, Jung B, Arnal JM, Matecki S, Jaber S. Prospective randomized crossover study comparing a new-full closed loop control solution and pressure support ventilation during weaning from mechanical ventilation. Anesthesiology. 2013 (in press).
42.
Zurück zum Zitat Drews FA, Westenskow DR. The right picture is worth a thousand numbers: data displays in anesthesia. Hum Factors. 2006;48(1):59–71.PubMedCrossRef Drews FA, Westenskow DR. The right picture is worth a thousand numbers: data displays in anesthesia. Hum Factors. 2006;48(1):59–71.PubMedCrossRef
43.
Zurück zum Zitat Wysocki M. Graphic user interface to improve patient safety during mechanical ventilation. Int J Intensive Care. 2007;14(1):2. Wysocki M. Graphic user interface to improve patient safety during mechanical ventilation. Int J Intensive Care. 2007;14(1):2.
45.
Zurück zum Zitat Keller JP, Diefes R, Graham K, Meyers M, Pelczarski K. Why clinical alarms are a ‘top ten’ hazard: how you can help reduce the risk. Biomed Instrum Technol. 2011; (Suppl):17–23. doi:10.2345/0899-8205-45.s1.17. Keller JP, Diefes R, Graham K, Meyers M, Pelczarski K. Why clinical alarms are a ‘top ten’ hazard: how you can help reduce the risk. Biomed Instrum Technol. 2011; (Suppl):17–23. doi:10.​2345/​0899-8205-45.​s1.​17.
46.
47.
Zurück zum Zitat Flechelles O, Ho A, Hernert P, Emeriaud G, Zaglam N, Cheriet F, Jouvet PA. Simulations for mechanical ventilation in children: review and future prospects. Crit Care Res Pract. 2013;2013:943281. doi:10.1155/2013/943281 Flechelles O, Ho A, Hernert P, Emeriaud G, Zaglam N, Cheriet F, Jouvet PA. Simulations for mechanical ventilation in children: review and future prospects. Crit Care Res Pract. 2013;2013:943281. doi:10.​1155/​2013/​943281
48.
Zurück zum Zitat Borycki EM, Kushniruk A, Keay E, Nicoll J, Anderson J, Anderson M. Toward an integrated simulation approach for predicting and preventing technology-induced errors in healthcare: implications for healthcare decision-makers. Healthcare Q. 2009;12(Spec No Patient):90–6.CrossRef Borycki EM, Kushniruk A, Keay E, Nicoll J, Anderson J, Anderson M. Toward an integrated simulation approach for predicting and preventing technology-induced errors in healthcare: implications for healthcare decision-makers. Healthcare Q. 2009;12(Spec No Patient):90–6.CrossRef
Metadaten
Titel
Closed loop mechanical ventilation
verfasst von
Marc Wysocki
Philippe Jouvet
Samir Jaber
Publikationsdatum
01.02.2014
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 1/2014
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-013-9465-2

Weitere Artikel der Ausgabe 1/2014

Journal of Clinical Monitoring and Computing 1/2014 Zur Ausgabe

Tipps für den Umgang mit Behandlungsfehlern

01.05.2024 DGIM 2024 Kongressbericht

Es ist nur eine Frage der Zeit, bis es zu einem Zwischenfall kommt und ein Behandlungsfehler passiert. Doch wenn Ärztinnen und Ärzte gut vorbereitet sind, schaffen es alle Beteiligten den Umständen entsprechend gut durch diese Krise. 

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Update AINS