Technology III: in-line vaporizer with reflector

verfasst von: A. Mashari, J. A. Fisher, L. Fedorko, M. Wąsowicz, M. Meineri

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

As the clinical advantages of vapor anesthesia (VA) for sedation of patients in ICU become more apparent, the ergonomics, economy and safety issues need to be better addressed. Here we describe the use of a new commercial digital in-line anesthetic vaporizer that can be attached to the inspiratory limb of a ventilator. If used with a simple, and easily assembled secondary circuit and anesthetic reflector, the circuit remains remote from the patient, the VA consumption approaches a physical minimum, VA level is controlled and monitored, and the tidal volume size is not limited.
Fußnoten
1
For example, AVEA (Carefusion, Yorba Linda, USA) performs a preparatory self-test to determine total circuit compliance. This would be performed with the RIVAL in the circuit. The iVent (GE Healthcare), performs a brief inspiratory hold to calculate static compliance. However, actual performance of specific ventilators with RIVAL would have to be tested.
 
Literatur
1.
Zurück zum Zitat Azami T, et al. Calculation of O2 consumption during low-flow anesthesia from tidal gas concentrations, flowmeter, and minute ventilation. J Clin Monit Comput. 2004;18:325–32.CrossRef Azami T, et al. Calculation of O2 consumption during low-flow anesthesia from tidal gas concentrations, flowmeter, and minute ventilation. J Clin Monit Comput. 2004;18:325–32.CrossRef
2.
Zurück zum Zitat Yasny JS, White J. Environmental implications of anesthetic gases. Anesth Prog. 2012;59:154–8.CrossRef Yasny JS, White J. Environmental implications of anesthetic gases. Anesth Prog. 2012;59:154–8.CrossRef
3.
Zurück zum Zitat Bomberg H, et al. A novel device for target controlled administration and reflection of desflurane—the Mirus. Anaesthesia. 2014;69:1241–50.CrossRef Bomberg H, et al. A novel device for target controlled administration and reflection of desflurane—the Mirus. Anaesthesia. 2014;69:1241–50.CrossRef
4.
Zurück zum Zitat Dahm SL, Steptoe P, Luttropp HH, Reinstrup P. Charcoal as an airway isoflurane reflection filter. Eur J Anaesthesiol. 1998;15:230–3.CrossRef Dahm SL, Steptoe P, Luttropp HH, Reinstrup P. Charcoal as an airway isoflurane reflection filter. Eur J Anaesthesiol. 1998;15:230–3.CrossRef
5.
Zurück zum Zitat Tempia A, et al. The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesia. Anesth Analg. 2003;96:1056–61 (table of contents).CrossRef Tempia A, et al. The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesia. Anesth Analg. 2003;96:1056–61 (table of contents).CrossRef
6.
Zurück zum Zitat Thomasson R, Luttropp HH, Werner O. A reflection filter for isoflurane and other anaesthetic vapours. Eur J Anaesthesiol. 1989;6:89–94.PubMed Thomasson R, Luttropp HH, Werner O. A reflection filter for isoflurane and other anaesthetic vapours. Eur J Anaesthesiol. 1989;6:89–94.PubMed
7.
Zurück zum Zitat Perhag L, Reinstrup P, Thomasson R, Werner O. The Reflector: a new method for saving anaesthetic vapours. Br J Anaesth. 2000;85:482–6.CrossRef Perhag L, Reinstrup P, Thomasson R, Werner O. The Reflector: a new method for saving anaesthetic vapours. Br J Anaesth. 2000;85:482–6.CrossRef
8.
Zurück zum Zitat Belda JF, et al. The predictive performance of a pharmacokinetic model for manually adjusted infusion of liquid sevofluorane for use with the Anesthetic-Conserving Device (AnaConDa): a clinical study. Anesth Analg. 2008;106:1207–14 (table of contents).CrossRef Belda JF, et al. The predictive performance of a pharmacokinetic model for manually adjusted infusion of liquid sevofluorane for use with the Anesthetic-Conserving Device (AnaConDa): a clinical study. Anesth Analg. 2008;106:1207–14 (table of contents).CrossRef
9.
Zurück zum Zitat Laferriere-Langlois P, d AF, Manzanares W. Halogenated volatile anesthetics in the intensive care unit: current knowledge on an upcoming practice. Minerva Anestesiol. 2017;83:737–48.PubMed Laferriere-Langlois P, d AF, Manzanares W. Halogenated volatile anesthetics in the intensive care unit: current knowledge on an upcoming practice. Minerva Anestesiol. 2017;83:737–48.PubMed
10.
Zurück zum Zitat Sturesson LW, Bodelsson M, Jonson B, Malmkvist G. Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilation. Br J Anaesth. 2014;113:508–14.CrossRef Sturesson LW, Bodelsson M, Jonson B, Malmkvist G. Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilation. Br J Anaesth. 2014;113:508–14.CrossRef
Metadaten
Titel
Technology III: in-line vaporizer with reflector
verfasst von
A. Mashari
J. A. Fisher
L. Fedorko
M. Wąsowicz
M. Meineri
Publikationsdatum
09.11.2017
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2018
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-017-0078-z

Weitere Artikel der Ausgabe 4/2018

Journal of Clinical Monitoring and Computing 4/2018 Zur Ausgabe

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.