Simulation study on flow rate accuracy of infusion pumps in vibration conditions during emergency patient transport

verfasst von: Kwan Young Hong, You Yeon Kim, Seung Yeon Yoo, Jong-Hwan Lee, Duk Kyung Kim, Jeong-Jin Min

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 6/2021

Einloggen, um Zugang zu erhalten

Abstract

Infusion pumps are frequently used when transferring critically ill patients via patient transport cart, ambulance, or helicopter. However, the performance of various infusion pumps under these circumstances has not been explored. The aim of this study was to evaluate the flow rate accuracy of infusion pumps under various clinical vibration conditions. Experiments were conducted with four different types of pumps, including two conventional syringe pumps (Injectomat MC Agilia, Fresenius Kabi and TE-331, Terumo), one conventional peristaltic pump (Volumed μVP7000; Arcomed), and one new cylinder pump (H-100, Meinntech). The flow rate was measured using an infusion pump analyzer on a stable table (0 m/s2) for 1 h with 1 ml/h and 5 ml/h. Experiments were repeated in mild vibration (2 m/s2) (representing vibration of patients in a moving stretcher or ambulance), and in moderate vibration (6 m/s2) (representing vibration in helicopter transport). Any accidental bolus occurrence in extreme vibration situations (20 m/s2) was also analyzed. Simulated vibrations were reproduced by a custom-made vibration table. In the resting state without vibration and in mild vibration conditions, all pumps maintained good performance. However, in moderate vibration, flow rates in syringe pumps increased beyond their known error ranges, while flow rates in peristaltic pumps remained stable. In extreme vibration, accidental fluid bolus occurred in syringe pumps but not in peristaltic pumps. The newly developed cylinder pump maintained stable performance and was unaffected by external vibration environments.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Fanara B, Manzon C, Barbot O, Desmettre T, Capellier G. Recommendations for the intra-hospital transport of critically ill patients. Crit Care. 2010;14(3):R87.CrossRef Fanara B, Manzon C, Barbot O, Desmettre T, Capellier G. Recommendations for the intra-hospital transport of critically ill patients. Crit Care. 2010;14(3):R87.CrossRef
2.
Zurück zum Zitat Duke GJ, Green JV. Outcome of critically ill patients undergoing interhospital transfer. Med J Aust. 2001;174(3):122–5.CrossRef Duke GJ, Green JV. Outcome of critically ill patients undergoing interhospital transfer. Med J Aust. 2001;174(3):122–5.CrossRef
3.
Zurück zum Zitat Droogh JM, Smit M, Absalom AR, Ligtenberg JJ, Zijlstra JG. Transferring the critically ill patient: are we there yet? Crit Care. 2015;19(1):62.CrossRef Droogh JM, Smit M, Absalom AR, Ligtenberg JJ, Zijlstra JG. Transferring the critically ill patient: are we there yet? Crit Care. 2015;19(1):62.CrossRef
4.
Zurück zum Zitat Fan E, MacDonald RD, Adhikari NK, Scales DC, Wax RS, Stewart TE, Ferguson ND. Outcomes of interfacility critical care adult patient transport: a systematic review. Crit Care. 2005;10(1):R6.CrossRef Fan E, MacDonald RD, Adhikari NK, Scales DC, Wax RS, Stewart TE, Ferguson ND. Outcomes of interfacility critical care adult patient transport: a systematic review. Crit Care. 2005;10(1):R6.CrossRef
5.
Zurück zum Zitat Taylor J, Chulay J, Landers C, Hood W Jr, Abelmann W. Monitoring high-risk cardiac patients during transportation in hospital. The Lancet. 1970;296(7685):1205–8.CrossRef Taylor J, Chulay J, Landers C, Hood W Jr, Abelmann W. Monitoring high-risk cardiac patients during transportation in hospital. The Lancet. 1970;296(7685):1205–8.CrossRef
6.
Zurück zum Zitat Kim UR, Peterfreund RA, Lovich MA. Drug infusion systems: technologies, performance, and pitfalls. Anesth Analg. 2017;124(5):1493–505.CrossRef Kim UR, Peterfreund RA, Lovich MA. Drug infusion systems: technologies, performance, and pitfalls. Anesth Analg. 2017;124(5):1493–505.CrossRef
7.
Zurück zum Zitat Snijder RA, Konings MK, Lucas P, Egberts TC, Timmerman AD. Flow variability and its physical causes in infusion technology: a systematic review of in vitro measurement and modeling studies. Biomed Eng. 2015;60(4):277–300.CrossRef Snijder RA, Konings MK, Lucas P, Egberts TC, Timmerman AD. Flow variability and its physical causes in infusion technology: a systematic review of in vitro measurement and modeling studies. Biomed Eng. 2015;60(4):277–300.CrossRef
8.
Zurück zum Zitat Husch M, Sullivan C, Rooney D, Barnard C, Fotis M, Clarke J, Noskin G. Insights from the sharp end of intravenous medication errors: implications for infusion pump technology. BMJ Qual Saf. 2005;14(2):80–6.CrossRef Husch M, Sullivan C, Rooney D, Barnard C, Fotis M, Clarke J, Noskin G. Insights from the sharp end of intravenous medication errors: implications for infusion pump technology. BMJ Qual Saf. 2005;14(2):80–6.CrossRef
10.
Zurück zum Zitat Lee SB, Lee K-h, Lee JJ, Choi JS, Lee SW. Cylinder pump. Google Patents; 2013. Lee SB, Lee K-h, Lee JJ, Choi JS, Lee SW. Cylinder pump. Google Patents; 2013.
11.
Zurück zum Zitat Yun JG, Jeung KW, Lee BK, Ryu HH, Lee HY, Kim MJ, Heo T, Min YI, You Y. Performance of an automated external defibrillator in a moving ambulance vehicle. Resuscitation. 2010;81(4):457–62.CrossRef Yun JG, Jeung KW, Lee BK, Ryu HH, Lee HY, Kim MJ, Heo T, Min YI, You Y. Performance of an automated external defibrillator in a moving ambulance vehicle. Resuscitation. 2010;81(4):457–62.CrossRef
12.
Zurück zum Zitat Chung TN, Kim SW, Cho YS, Chung SP, Park I, Kim SH. Effect of vehicle speed on the quality of closed-chest compression during ambulance transport. Resuscitation. 2010;81(7):841–7.CrossRef Chung TN, Kim SW, Cho YS, Chung SP, Park I, Kim SH. Effect of vehicle speed on the quality of closed-chest compression during ambulance transport. Resuscitation. 2010;81(7):841–7.CrossRef
13.
Zurück zum Zitat Je SM, You JS, Chung TN, Park YS, Chung SP, Park IC. Performance of an automated external defibrillator during simulated rotor-wing critical care transports. Resuscitation. 2011;82(4):454–8.CrossRef Je SM, You JS, Chung TN, Park YS, Chung SP, Park IC. Performance of an automated external defibrillator during simulated rotor-wing critical care transports. Resuscitation. 2011;82(4):454–8.CrossRef
17.
Zurück zum Zitat Min JJ, Kim DK, Hong KY, Choi JW, Choi KY. Comparison of operator workloads associated with the single-unit Anyfusion® pump and the changeover from a syringe pump to an infusion pump. J Korean Med Sci. 2019;34(49):e314.CrossRef Min JJ, Kim DK, Hong KY, Choi JW, Choi KY. Comparison of operator workloads associated with the single-unit Anyfusion® pump and the changeover from a syringe pump to an infusion pump. J Korean Med Sci. 2019;34(49):e314.CrossRef
19.
Zurück zum Zitat Batista E, e Sousa JA, Ribeiro Á, Martins L, Pereira M, Navas H Calibration of infusion pumps analyser. In: Journal of Physics: Conference Series. IOP Publishing; 2018. vol 9. p. 092003. Batista E, e Sousa JA, Ribeiro Á, Martins L, Pereira M, Navas H Calibration of infusion pumps analyser. In: Journal of Physics: Conference Series. IOP Publishing; 2018. vol 9. p. 092003.
20.
Zurück zum Zitat Stokes D, Peacock J, Lewis R, Hutton P. The Ohmeda 9000 syringe pump. The first of a new generation of syringe drivers. Anaesthesia. 1990;45(12):1062–6.CrossRef Stokes D, Peacock J, Lewis R, Hutton P. The Ohmeda 9000 syringe pump. The first of a new generation of syringe drivers. Anaesthesia. 1990;45(12):1062–6.CrossRef
21.
Zurück zum Zitat Dunster K, Colditz P. Flow continuity of infusion systems at low flow rates. Anaesth Intensive Care. 1995;23(5):605–9.CrossRef Dunster K, Colditz P. Flow continuity of infusion systems at low flow rates. Anaesth Intensive Care. 1995;23(5):605–9.CrossRef
22.
Zurück zum Zitat Stull JC, Erenberg A, Leff RD. Flow rate variability from electronic infusion devices. Crit Care Med. 1988;16(9):888–91.CrossRef Stull JC, Erenberg A, Leff RD. Flow rate variability from electronic infusion devices. Crit Care Med. 1988;16(9):888–91.CrossRef
23.
Zurück zum Zitat Connor SB, Quill TJ, Jacobs JR. Accuracy of drug infusion pumps under computer control. IEEE Trans Biomed Eng. 1992;39(9):980–2.CrossRef Connor SB, Quill TJ, Jacobs JR. Accuracy of drug infusion pumps under computer control. IEEE Trans Biomed Eng. 1992;39(9):980–2.CrossRef
24.
Zurück zum Zitat Linden V, Palmer K, Reinhard J, Westman R, Ehren H, Granholm T, Frenckner B. Inter-hospital transportation of patients with severe acute respiratory failure on extracorporeal membrane oxygenation–national and international experience. Intensive Care Med. 2001;27(10):1643–8.CrossRef Linden V, Palmer K, Reinhard J, Westman R, Ehren H, Granholm T, Frenckner B. Inter-hospital transportation of patients with severe acute respiratory failure on extracorporeal membrane oxygenation–national and international experience. Intensive Care Med. 2001;27(10):1643–8.CrossRef
25.
Zurück zum Zitat Coppola CP, Tyree M, Larry K, DiGeronimo R. A 22-year experience in global transport extracorporeal membrane oxygenation. J Pediatr Surg. 2008;43(1):46–52.CrossRef Coppola CP, Tyree M, Larry K, DiGeronimo R. A 22-year experience in global transport extracorporeal membrane oxygenation. J Pediatr Surg. 2008;43(1):46–52.CrossRef
26.
Zurück zum Zitat Bryner B, Cooley E, Copenhaver W, Brierley K, Teman N, Landis D, Rycus P, Hemmila M, Napolitano LM, Haft J. Two decades’ experience with interfacility transport on extracorporeal membrane oxygenation. Ann Thorac Surg. 2014;98(4):1363–70.CrossRef Bryner B, Cooley E, Copenhaver W, Brierley K, Teman N, Landis D, Rycus P, Hemmila M, Napolitano LM, Haft J. Two decades’ experience with interfacility transport on extracorporeal membrane oxygenation. Ann Thorac Surg. 2014;98(4):1363–70.CrossRef
27.
Zurück zum Zitat Capes DF, Dunster KR, Sunderland VB, McMillan D, Colditz PB, McDonald C. Fluctuations in syringe-pump infusions: association with blood pressure variations in infants. Am J Health Syst Pharm. 1995;52(15):1646–53.CrossRef Capes DF, Dunster KR, Sunderland VB, McMillan D, Colditz PB, McDonald C. Fluctuations in syringe-pump infusions: association with blood pressure variations in infants. Am J Health Syst Pharm. 1995;52(15):1646–53.CrossRef
28.
Zurück zum Zitat Klem SA, Farrington JM, Leff RD. Influence of infusion pump operation and flow rate on hemodynamic stability during epinephrine infusion. Crit Care Med. 1993;21(8):1213–7.CrossRef Klem SA, Farrington JM, Leff RD. Influence of infusion pump operation and flow rate on hemodynamic stability during epinephrine infusion. Crit Care Med. 1993;21(8):1213–7.CrossRef
29.
Zurück zum Zitat Pelletier NP, Fisher A. Infusion pump in UH60L/M flight in Afghanistan: why failures occur. Air Med J. 2017;36(5):248–57.CrossRef Pelletier NP, Fisher A. Infusion pump in UH60L/M flight in Afghanistan: why failures occur. Air Med J. 2017;36(5):248–57.CrossRef
30.
Zurück zum Zitat van der Eijk AC, van Rens RM, Dankelman J, Smit BJ. A literature review on flow-rate variability in neonatal IV therapy. Pediatric Anesth. 2013;23(1):9–21.CrossRef van der Eijk AC, van Rens RM, Dankelman J, Smit BJ. A literature review on flow-rate variability in neonatal IV therapy. Pediatric Anesth. 2013;23(1):9–21.CrossRef
31.
Zurück zum Zitat Kern H, Kuring A, Redlich U, Döpfmer U, Sims N, Spies C, Kox W. Downward movement of syringe pumps reduces syringe output. Br J Anaesth. 2001;86(6):828–31.CrossRef Kern H, Kuring A, Redlich U, Döpfmer U, Sims N, Spies C, Kox W. Downward movement of syringe pumps reduces syringe output. Br J Anaesth. 2001;86(6):828–31.CrossRef
32.
Zurück zum Zitat Lönnqvist P, Löfqvist B. Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intensive Care Med. 1997;23(9):998–1001.CrossRef Lönnqvist P, Löfqvist B. Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intensive Care Med. 1997;23(9):998–1001.CrossRef
33.
Zurück zum Zitat Weiss M, Bänziger O, Neff T, Fanconi S. Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Med. 2000;26(6):776–9.CrossRef Weiss M, Bänziger O, Neff T, Fanconi S. Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Med. 2000;26(6):776–9.CrossRef
34.
Zurück zum Zitat Kim DW, Steward DJ. The effect of syringe size on the performance of an infusion pump. Pediatric Anesth. 1999;9(4):335–7.CrossRef Kim DW, Steward DJ. The effect of syringe size on the performance of an infusion pump. Pediatric Anesth. 1999;9(4):335–7.CrossRef
35.
Zurück zum Zitat Lin JA. The effect of syringe size on reliability and safety of low-flow infusions. Pediatric Crit Care Med. 2009;10(5):592–6.CrossRef Lin JA. The effect of syringe size on reliability and safety of low-flow infusions. Pediatric Crit Care Med. 2009;10(5):592–6.CrossRef
36.
Zurück zum Zitat Palmer KT, Griffin MJ, Bendall H, Pannett B, Coggon D. Prevalence and pattern of occupational exposure to whole body vibration in Great Britain: findings from a national survey. Occup Environ Med. 2000;57(4):229–36.CrossRef Palmer KT, Griffin MJ, Bendall H, Pannett B, Coggon D. Prevalence and pattern of occupational exposure to whole body vibration in Great Britain: findings from a national survey. Occup Environ Med. 2000;57(4):229–36.CrossRef
37.
Zurück zum Zitat Bongers P, Hulshof C, Dljkstra L, Boshuizen H, Groenhout H, Valken E. Back pain and exposure to whole body vibration in helicopter pilots. Ergonomics. 1990;33(8):1007–266.CrossRef Bongers P, Hulshof C, Dljkstra L, Boshuizen H, Groenhout H, Valken E. Back pain and exposure to whole body vibration in helicopter pilots. Ergonomics. 1990;33(8):1007–266.CrossRef
38.
Zurück zum Zitat Kim JH, Kim TK, In J, Lee DK, Lee S, Kang H. Assessment of risk of bias in quasi-randomized controlled trials and randomized controlled trials reported in the Korean Journal of Anesthesiology between 2010 and 2016. Korean J Anesthesiol. 2017;70(5):511.CrossRef Kim JH, Kim TK, In J, Lee DK, Lee S, Kang H. Assessment of risk of bias in quasi-randomized controlled trials and randomized controlled trials reported in the Korean Journal of Anesthesiology between 2010 and 2016. Korean J Anesthesiol. 2017;70(5):511.CrossRef
Metadaten
Titel
Simulation study on flow rate accuracy of infusion pumps in vibration conditions during emergency patient transport
verfasst von
Kwan Young Hong
You Yeon Kim
Seung Yeon Yoo
Jong-Hwan Lee
Duk Kyung Kim
Jeong-Jin Min
Publikationsdatum
06.11.2020
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2021
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00588-7

Weitere Artikel der Ausgabe 6/2021

Journal of Clinical Monitoring and Computing 6/2021 Zur Ausgabe

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.