01.11.2004 | Erratum
Pattern of lung emptying and expiratory resistance in mechanically ventilated patients with chronic obstructive pulmonary disease
Erschienen in: Intensive Care Medicine | Ausgabe 11/2004
Einloggen, um Zugang zu erhaltenExcerpt
In Tables 4 and 5, symbols and values were incorrectly rendered in the online PDF version and in print. Only in the online HTML version were the tables reproduced correctly. The tables should appear as follows:
Volume slice
|
PEEP (cmH2O)
|
|||||
---|---|---|---|---|---|---|
τ (s)
|
τrs (s)
|
|||||
0
|
5
|
10
|
0
|
5
|
10
|
|
1
|
1.19±0.6*
|
1.20±0.6*
|
0.87±0.3*
|
1.10±0.7*&
|
1.06±0.6*&
|
0.70±0.4&
|
2
|
1.90±0.9*
|
1.54±0.6
|
1.16±0.4+
|
1.80±1.0*&
|
1.41±0.7&
|
0.95±0.5+&
|
3
|
2.58±1.2*
|
1.95±0.9
|
1.32±0.4+
|
2.53±1.3*
|
1.82±0.9+&
|
1.11±0.4+&
|
4
|
3.03±1.6*
|
2.18±1.3+
|
1.50±0.7+
|
3.00±1.7*
|
2.04±1.3+&
|
1.28±0.7+&
|
5
|
3.75±2.3
|
2.15±1.0+
|
1.58±0.7+
|
3.75±2.3
|
1.97±1.0+&
|
1.33±0.7+&
|
Volume slice
|
PEEP (cmH2O)
|
|||||
---|---|---|---|---|---|---|
Rtot (cmH2O/l/s)
|
Rrs (cmH2O/l/s)
|
|||||
0
|
5
|
10
|
0
|
5
|
10
|
|
1
|
23.83±8.1*
|
24.92±7.4
|
21.13±6.3
|
20.94±11.0*&
|
21.29±9.3&
|
16.68±7.4&
|
2
|
31.36±12.3*
|
26.55±7.1
|
20.50±4.3+
|
29.02±15.6*&
|
23.69±9.1&
|
16.50±5.7+&
|
3
|
36.94±15.9*
|
28.98±10.7
|
19.22±3.7+
|
35.82±17.2*
|
26.71±12.3&
|
15.85±4.4+&
|
4
|
40.22±22.3
|
28.42±14.3+
|
18.12±4.6+
|
39.56±23.1
|
26.28±15.6+&
|
15.20±4.7+&
|
5
|
46.61±28.9
|
26.34±12.0+
|
17.82±7.4+
|
46.61±28.9
|
23.93±12.2+&
|
15.00±7.5+&
|