Skip to main content
Erschienen in: European Radiology 12/2008

01.12.2008 | Cardiac

Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography

verfasst von: Sebastian Leschka, Paul Stolzmann, Hans Scheffel, Simon Wildermuth, André Plass, Michele Genoni, Borut Marincek, Hatem Alkadhi

Erschienen in: European Radiology | Ausgabe 12/2008

Einloggen, um Zugang zu erhalten

Abstract

To assess the prevalence and morphological characteristics of coronary artery ectasia (CAE) with CT coronary angiography (CTCA) in comparison to conventional catheterangiography (CCA). Dual-source CTCA examinations from 677 consecutive patients (223 women; median age 57 years) were retrospectively evaluated by two blinded observers for the presence of CAE defined as a diameter enlargement ≥1.5 times the diameter of adjacent normal coronary segments. Vessel diameters and contrast attenuation within and proximal to ectatic segments were measured. CCA was used to compare measurements obtained from CTCA with the coronary flow velocity by using the thrombolysis in myocardial infarction (TIMI) frame count. CTCA identified CAE in 20 of 677 (3%) patients. CCA was performed in ten of these patients. CAE diameter measurements with CTCA (10.0 ± 5.4 mm) correlated significantly (r = 0.92, p < 0.001) with the CCA measurements (8.8 ± 4.9 mm), but had higher diameters (levels of agreement: −1.0 to 3.4 mm). Contrast attenuation was significantly lower in the ectatic (343 ± 63 HU) than in the proximal (394 ± 60 HU) segments (p < 0.01). The attenuation difference significantly correlated with the CAE ratio (r = 0.67, p < 0.01) and the TIMI frame count (r = 0.58, p < 0.05). The prevalence of CAE in a population examined by CTCA is around 3%. Contrast attenuation measurements with CTCA correlate well with the flow alterations assessed with CCA.
Literatur
1.
Zurück zum Zitat Falsetti HL, Carrol RJ (1976) Coronary artery aneurysm. A review of the literature with a report of 11 new cases. Chest 69:630–636PubMedCrossRef Falsetti HL, Carrol RJ (1976) Coronary artery aneurysm. A review of the literature with a report of 11 new cases. Chest 69:630–636PubMedCrossRef
2.
Zurück zum Zitat Swaye PS, Fisher LD, Litwin P et al (1983) Aneurysmal coronary artery disease. Circulation 67:134–138PubMed Swaye PS, Fisher LD, Litwin P et al (1983) Aneurysmal coronary artery disease. Circulation 67:134–138PubMed
3.
Zurück zum Zitat Manginas A, Cokkinos DV (2006) Coronary artery ectasias: imaging, functional assessment and clinical implications. Eur Heart J 27:1026–1031PubMedCrossRef Manginas A, Cokkinos DV (2006) Coronary artery ectasias: imaging, functional assessment and clinical implications. Eur Heart J 27:1026–1031PubMedCrossRef
4.
Zurück zum Zitat Lam CS, Ho KT (2004) Coronary artery ectasia: a 10-year experience in a tertiary hospital in Singapore. Ann Acad Med Singapore 33:419–422PubMed Lam CS, Ho KT (2004) Coronary artery ectasia: a 10-year experience in a tertiary hospital in Singapore. Ann Acad Med Singapore 33:419–422PubMed
5.
Zurück zum Zitat Suzuki H, Takeyama Y, Hamazaki Y et al (1994) Coronary spasm in patients with coronary ectasia. Cathet Cardiovasc Diagn 32:1–7PubMedCrossRef Suzuki H, Takeyama Y, Hamazaki Y et al (1994) Coronary spasm in patients with coronary ectasia. Cathet Cardiovasc Diagn 32:1–7PubMedCrossRef
6.
Zurück zum Zitat Kruger D, Stierle U, Herrmann G, Simon R, Sheikhzadeh A (1999) Exercise-induced myocardial ischemia in isolated coronary artery ectasias and aneurysms (“dilated coronopathy”). J Am Coll Cardiol 34:1461–1470PubMedCrossRef Kruger D, Stierle U, Herrmann G, Simon R, Sheikhzadeh A (1999) Exercise-induced myocardial ischemia in isolated coronary artery ectasias and aneurysms (“dilated coronopathy”). J Am Coll Cardiol 34:1461–1470PubMedCrossRef
7.
Zurück zum Zitat Perlman PE, Ridgeway NA (1989) Thrombosis and anticoagulation therapy in coronary ectasia. Clin Cardiol 12:541–542PubMedCrossRef Perlman PE, Ridgeway NA (1989) Thrombosis and anticoagulation therapy in coronary ectasia. Clin Cardiol 12:541–542PubMedCrossRef
8.
Zurück zum Zitat Huikuri HV, Mallon SM, Myerburg RJ (1991) Cardiac arrest due to spontaneous coronary artery dissection in a patient with coronary ectasia-a case report. Angiology 42:148–151PubMedCrossRef Huikuri HV, Mallon SM, Myerburg RJ (1991) Cardiac arrest due to spontaneous coronary artery dissection in a patient with coronary ectasia-a case report. Angiology 42:148–151PubMedCrossRef
9.
Zurück zum Zitat Satoda M, Tatsukawa H, Katoh S (1998) Images in cardiovascular medicine. Sudden death due to rupture of coronary aneurysm in a 26-year-old man. Circulation 97:705–706PubMed Satoda M, Tatsukawa H, Katoh S (1998) Images in cardiovascular medicine. Sudden death due to rupture of coronary aneurysm in a 26-year-old man. Circulation 97:705–706PubMed
10.
Zurück zum Zitat Ramappa P, Kottam A, Kuivanemi H, Thatai D (2007) Coronary artery ectasia - is it time for a reappraisal? Clin Cardiol 30:214–217PubMedCrossRef Ramappa P, Kottam A, Kuivanemi H, Thatai D (2007) Coronary artery ectasia - is it time for a reappraisal? Clin Cardiol 30:214–217PubMedCrossRef
11.
Zurück zum Zitat Markis JE, Joffe CD, Cohn PF, Feen DJ, Herman MV, Gorlin R (1976) Clinical significance of coronary arterial ectasia. Am J Cardiol 37:217–222PubMedCrossRef Markis JE, Joffe CD, Cohn PF, Feen DJ, Herman MV, Gorlin R (1976) Clinical significance of coronary arterial ectasia. Am J Cardiol 37:217–222PubMedCrossRef
12.
Zurück zum Zitat Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef
13.
Zurück zum Zitat Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 26:1482–1487PubMedCrossRef
14.
Zurück zum Zitat Mollet NR, Cademartiri F, van Mieghem CA et al (2005) High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 112:2318–2323PubMedCrossRef Mollet NR, Cademartiri F, van Mieghem CA et al (2005) High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography. Circulation 112:2318–2323PubMedCrossRef
15.
Zurück zum Zitat Ong TK, Chin SP, Liew CK et al (2006) Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 151:1323 e1321–1323 e1326 Ong TK, Chin SP, Liew CK et al (2006) Accuracy of 64-row multidetector computed tomography in detecting coronary artery disease in 134 symptomatic patients: influence of calcification. Am Heart J 151:1323 e1321–1323 e1326
16.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef Raff GL, Gallagher MJ, O’Neill WW, Goldstein JA (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef
17.
Zurück zum Zitat Achenbach S, Ropers D, Kuettner A et al (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience. Eur J Radiol 57:331–335PubMedCrossRef Achenbach S, Ropers D, Kuettner A et al (2006) Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience. Eur J Radiol 57:331–335PubMedCrossRef
18.
Zurück zum Zitat Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268PubMedCrossRef Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268PubMedCrossRef
19.
Zurück zum Zitat Scheffel H, Alkadhi H, Plass A et al (2006) Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16:2739–2747PubMedCrossRef Scheffel H, Alkadhi H, Plass A et al (2006) Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol 16:2739–2747PubMedCrossRef
20.
Zurück zum Zitat Budoff MJ, Achenbach S, Blumenthal RS et al (2006) Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology. Circulation 114:1761–1791PubMedCrossRef Budoff MJ, Achenbach S, Blumenthal RS et al (2006) Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology. Circulation 114:1761–1791PubMedCrossRef
21.
Zurück zum Zitat Fox K, Garcia MA, Ardissino D et al (2006) Guidelines on the management of stable angina pectoris: executive summary: the Task Force on the Management of Stable Angina Pectoris of the European Society of Cardiology. Eur Heart J 27:1341–1381PubMedCrossRef Fox K, Garcia MA, Ardissino D et al (2006) Guidelines on the management of stable angina pectoris: executive summary: the Task Force on the Management of Stable Angina Pectoris of the European Society of Cardiology. Eur Heart J 27:1341–1381PubMedCrossRef
22.
Zurück zum Zitat Hendel RC, Patel MR, Kramer CM et al (2006) ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48:1475–1497PubMedCrossRef Hendel RC, Patel MR, Kramer CM et al (2006) ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48:1475–1497PubMedCrossRef
23.
Zurück zum Zitat Wells TA, Peebles CR, Gray HG (2008) Giant left anterior descending coronary artery aneurysm. Int J Cardiol 126(2):e27–e28 Epub 2007 Mar 28PubMedCrossRef Wells TA, Peebles CR, Gray HG (2008) Giant left anterior descending coronary artery aneurysm. Int J Cardiol 126(2):e27–e28 Epub 2007 Mar 28PubMedCrossRef
24.
Zurück zum Zitat Goz M, Cakir O (2007) Multiple coronary artery aneurysms that cause thrombosis: 22-month follow-up results with multi-slice spiral computerized tomography without surgery. Int J Cardiol 119(2):e48–e50 Epub 2007 May 2PubMedCrossRef Goz M, Cakir O (2007) Multiple coronary artery aneurysms that cause thrombosis: 22-month follow-up results with multi-slice spiral computerized tomography without surgery. Int J Cardiol 119(2):e48–e50 Epub 2007 May 2PubMedCrossRef
25.
Zurück zum Zitat Morise AP, Haddad WJ, Beckner D (1997) Development and validation of a clinical score to estimate the probability of coronary artery disease in men and women presenting with suspected coronary disease. Am J Med 102:350–356PubMedCrossRef Morise AP, Haddad WJ, Beckner D (1997) Development and validation of a clinical score to estimate the probability of coronary artery disease in men and women presenting with suspected coronary disease. Am J Med 102:350–356PubMedCrossRef
26.
Zurück zum Zitat Leschka S, Scheffel H, Desbiolles L et al (2007) Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG pulsing windowing. Invest Radiol 42:543–549PubMedCrossRef Leschka S, Scheffel H, Desbiolles L et al (2007) Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG pulsing windowing. Invest Radiol 42:543–549PubMedCrossRef
27.
Zurück zum Zitat Stolzmann P, Scheffel H, Schertler T et al (2008) Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18:592–599PubMedCrossRef Stolzmann P, Scheffel H, Schertler T et al (2008) Radiation dose estimates in dual-source computed tomography coronary angiography. Eur Radiol 18:592–599PubMedCrossRef
28.
Zurück zum Zitat Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed
29.
Zurück zum Zitat Gibson CM, Cannon CP, Daley WL et al (1996) TIMI frame count: a quantitative method of assessing coronary artery flow. Circulation 93:879–888PubMed Gibson CM, Cannon CP, Daley WL et al (1996) TIMI frame count: a quantitative method of assessing coronary artery flow. Circulation 93:879–888PubMed
30.
Zurück zum Zitat Aintablian A, Hamby RI, Hoffman I, Kramer RJ (1978) Coronary ectasia: incidence and results of coronary bypass surgery. Am Heart J 96:309–315PubMedCrossRef Aintablian A, Hamby RI, Hoffman I, Kramer RJ (1978) Coronary ectasia: incidence and results of coronary bypass surgery. Am Heart J 96:309–315PubMedCrossRef
31.
Zurück zum Zitat Hartnell GG, Parnell BM, Pridie RB (1985) Coronary artery ectasia. Its prevalence and clinical significance in 4993 patients. Br Heart J 54:392–395PubMedCrossRef Hartnell GG, Parnell BM, Pridie RB (1985) Coronary artery ectasia. Its prevalence and clinical significance in 4993 patients. Br Heart J 54:392–395PubMedCrossRef
32.
Zurück zum Zitat Frauenfelder T, Boutsianis E, Schertler T et al (2007) In-vivo flow simulation in coronary arteries based on computed tomography datasets: feasibility and initial results. Eur Radiol 17:1291–1300PubMedCrossRef Frauenfelder T, Boutsianis E, Schertler T et al (2007) In-vivo flow simulation in coronary arteries based on computed tomography datasets: feasibility and initial results. Eur Radiol 17:1291–1300PubMedCrossRef
33.
Zurück zum Zitat Akyurek O, Berkalp B, Sayin T, Kumbasar D, Kervancioglu C, Oral D (2003) Altered coronary flow properties in diffuse coronary artery ectasia. Am Heart J 145:66–72PubMedCrossRef Akyurek O, Berkalp B, Sayin T, Kumbasar D, Kervancioglu C, Oral D (2003) Altered coronary flow properties in diffuse coronary artery ectasia. Am Heart J 145:66–72PubMedCrossRef
34.
Zurück zum Zitat Hamaoka K, Onouchi Z, Kamiya Y, Sakata K (1998) Evaluation of coronary flow velocity dynamics and flow reserve in patients with Kawasaki disease by means of a Doppler guide wire. J Am Coll Cardiol 31:833–840PubMedCrossRef Hamaoka K, Onouchi Z, Kamiya Y, Sakata K (1998) Evaluation of coronary flow velocity dynamics and flow reserve in patients with Kawasaki disease by means of a Doppler guide wire. J Am Coll Cardiol 31:833–840PubMedCrossRef
35.
Zurück zum Zitat Papadakis MC, Manginas A, Cotileas P et al (2001) Documentation of slow coronary flow by the TIMI frame count in patients with coronary ectasia. Am J Cardiol 88:1030–1032PubMedCrossRef Papadakis MC, Manginas A, Cotileas P et al (2001) Documentation of slow coronary flow by the TIMI frame count in patients with coronary ectasia. Am J Cardiol 88:1030–1032PubMedCrossRef
36.
Zurück zum Zitat Kosar F, Acikgoz N, Sahin I, Topal E, Aksoy Y, Cehreli S (2005) Effect of ectasia size or the ectasia ratio on the thrombosis in myocardial infarction frame count in patients with isolated coronary artery ectasia. Heart Vessels 20:199–202PubMedCrossRef Kosar F, Acikgoz N, Sahin I, Topal E, Aksoy Y, Cehreli S (2005) Effect of ectasia size or the ectasia ratio on the thrombosis in myocardial infarction frame count in patients with isolated coronary artery ectasia. Heart Vessels 20:199–202PubMedCrossRef
Metadaten
Titel
Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography
verfasst von
Sebastian Leschka
Paul Stolzmann
Hans Scheffel
Simon Wildermuth
André Plass
Michele Genoni
Borut Marincek
Hatem Alkadhi
Publikationsdatum
01.12.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1087-6

Weitere Artikel der Ausgabe 12/2008

European Radiology 12/2008 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.