Skip to main content
Erschienen in: Japanese Journal of Radiology 7/2017

27.04.2017 | Original Article

Quantitative accuracy of computed tomography perfusion under low-dose conditions, measured using a hollow-fiber phantom

verfasst von: Kazufumi Suzuki, Hiroyuki Hashimoto, Eiji Okaniwa, Hiroshi Iimura, Shingo Suzaki, Kayoko Abe, Shuji Sakai

Erschienen in: Japanese Journal of Radiology | Ausgabe 7/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to investigate the quantitative accuracy under low-dose conditions on computed tomography (CT) perfusion using a hollow-fiber phantom that had the theoretical absolute values of perfusion indices.

Materials and methods

Our phantom comprised two components, i.e., a hollow-fiber hemodialyzer to pump the diluted contrast material and a surrounding syringe-shaped X-ray-absorbing body to simulate the absorption of X-rays by a brain and cranium. We performed CTP scans on the phantom under various dose conditions ranging from 20 to 140 mA using a 64-row CT scanner, measuring experimental cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), and time to peak (TTP) values using a deconvolution algorithm.

Results

The theoretical value of the CBV was within the 95% confidence interval of CBV values measured under 80 mA. The CBV measured under low-dose settings and all CBF values measured were smaller than the theoretically calculated ones, and all MTT values measured were larger. All measured values of the CBV, CBF, MTT, and TTP decreased with an increase in image noise under lower dose conditions.

Conclusion

It is difficult to define a low-dose limit in clinical scan conditions because of the complex characteristics of perfusion indices.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Klotz E, König M. Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke. Eur J Radiol. 1999;30:170–84.CrossRefPubMed Klotz E, König M. Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute stroke. Eur J Radiol. 1999;30:170–84.CrossRefPubMed
2.
Zurück zum Zitat Mayer TE, Hamann GF, Baranczyk J, Rosengarten B, Klotz E, Wiesmann M, et al. Dynamic CT perfusion imaging of acute stroke. AJNR Am J Neuroradiol. 2000;21:1441–9.PubMed Mayer TE, Hamann GF, Baranczyk J, Rosengarten B, Klotz E, Wiesmann M, et al. Dynamic CT perfusion imaging of acute stroke. AJNR Am J Neuroradiol. 2000;21:1441–9.PubMed
3.
Zurück zum Zitat Lev MH, Segal AZ, Farkas J, Hossain ST, Putman C, Hunter GJ, et al. Utility of perfusion-weighted CT imaging in acute middle cerebral artery stroke treated with intra-arterial thrombolysis: prediction of final infarct volume and clinical outcome. Stroke. 2001;32:2021–8.CrossRefPubMed Lev MH, Segal AZ, Farkas J, Hossain ST, Putman C, Hunter GJ, et al. Utility of perfusion-weighted CT imaging in acute middle cerebral artery stroke treated with intra-arterial thrombolysis: prediction of final infarct volume and clinical outcome. Stroke. 2001;32:2021–8.CrossRefPubMed
4.
Zurück zum Zitat Othman AE, Afat S, Brockmann MA, Nikoubashman O, Brockmann C, Nikolaou K, et al. Radiation dose reduction in perfusion CT imaging of the brain: a review of the literature. J Neuroradiol. 2015;43:1–5.CrossRefPubMed Othman AE, Afat S, Brockmann MA, Nikoubashman O, Brockmann C, Nikolaou K, et al. Radiation dose reduction in perfusion CT imaging of the brain: a review of the literature. J Neuroradiol. 2015;43:1–5.CrossRefPubMed
5.
Zurück zum Zitat Ogawa T, Hosokawa H. Nihonjin-no-nou (Japanese). Tokyo: Kanehara Co., Ltd.; 1953. p. 9–28. Ogawa T, Hosokawa H. Nihonjin-no-nou (Japanese). Tokyo: Kanehara Co., Ltd.; 1953. p. 9–28.
6.
Zurück zum Zitat Meier P, Zierler KL. On the theory of the indicator-dilution method for measurement of blood flow and volume. Appl Physiol. 1954;6:731–44. Meier P, Zierler KL. On the theory of the indicator-dilution method for measurement of blood flow and volume. Appl Physiol. 1954;6:731–44.
7.
Zurück zum Zitat Powers WJ. Cerebral hemodynamics in ischemic cerebrovascular disease. Ann Neurol. 1991;29:231–40.CrossRefPubMed Powers WJ. Cerebral hemodynamics in ischemic cerebrovascular disease. Ann Neurol. 1991;29:231–40.CrossRefPubMed
8.
Zurück zum Zitat Wu O, Ostergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med. 2003;50:164–74.CrossRefPubMed Wu O, Ostergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG. Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix. Magn Reson Med. 2003;50:164–74.CrossRefPubMed
9.
Zurück zum Zitat Kudo K, Sasaki M, Yamada K, Momoshima S, Utsunomiya H, Shirato H, et al. Differences in CT perfusion maps generated by different commercial software: quantitative analysis by using identical source data of acute stroke patients. Radiology. 2010;254:200–9.CrossRefPubMed Kudo K, Sasaki M, Yamada K, Momoshima S, Utsunomiya H, Shirato H, et al. Differences in CT perfusion maps generated by different commercial software: quantitative analysis by using identical source data of acute stroke patients. Radiology. 2010;254:200–9.CrossRefPubMed
10.
Zurück zum Zitat Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med. 2000;44:466–73.CrossRefPubMed Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med. 2000;44:466–73.CrossRefPubMed
11.
Zurück zum Zitat Konstas AA, Goldmakher GV, Lee TY, Lev MH. Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke. Part 1. Theoretic basis. AJNR Am J Neuroradiol. 2009;30:662–8.CrossRefPubMed Konstas AA, Goldmakher GV, Lee TY, Lev MH. Theoretic basis and technical implementations of CT perfusion in acute ischemic stroke. Part 1. Theoretic basis. AJNR Am J Neuroradiol. 2009;30:662–8.CrossRefPubMed
12.
Zurück zum Zitat Heiss WD, Grond M, Thiel A, von Stockhausen HM, Rudolf J. Ischaemic brain tissue salvaged from infarction with alteplase. Lancet. 1997;349:1599–600.CrossRefPubMed Heiss WD, Grond M, Thiel A, von Stockhausen HM, Rudolf J. Ischaemic brain tissue salvaged from infarction with alteplase. Lancet. 1997;349:1599–600.CrossRefPubMed
13.
Zurück zum Zitat Wintermark M, Flanders AE, Velthuis B, Meuli R, Van Leeuwen M, Goldsher D, et al. Perfusion-CT assessment of infarct core and penumbra: receiver operating characteristic curve analysis in 130 patients suspected of acute hemispheric stroke. Stroke. 2006;37:979–85.CrossRefPubMed Wintermark M, Flanders AE, Velthuis B, Meuli R, Van Leeuwen M, Goldsher D, et al. Perfusion-CT assessment of infarct core and penumbra: receiver operating characteristic curve analysis in 130 patients suspected of acute hemispheric stroke. Stroke. 2006;37:979–85.CrossRefPubMed
14.
Zurück zum Zitat Ding B, Ling HW, Chen KM, Jiang H, Zhu YB. Comparison of cerebral blood volume and permeability in preoperative grading of intracranial glioma using CT perfusion imaging. Neuroradiology. 2006;48:773–81.CrossRefPubMed Ding B, Ling HW, Chen KM, Jiang H, Zhu YB. Comparison of cerebral blood volume and permeability in preoperative grading of intracranial glioma using CT perfusion imaging. Neuroradiology. 2006;48:773–81.CrossRefPubMed
15.
Zurück zum Zitat Ellika S, Jain R, Patel S, Scarpace L, Schultz LR, Rock JP, et al. Role of perfusion CT in glioma grading and comparison with conventional MR imaging features. Am J Neuroradiol. 2012;33:2038–42.CrossRef Ellika S, Jain R, Patel S, Scarpace L, Schultz LR, Rock JP, et al. Role of perfusion CT in glioma grading and comparison with conventional MR imaging features. Am J Neuroradiol. 2012;33:2038–42.CrossRef
16.
Zurück zum Zitat Reichenbach JR, Röther J, Jonetz-Mentzel L, Herzau M, Fiala A, Weiller C, et al. Acute stroke evaluated by time-to-peak mapping during initial and early follow-up perfusion CT studies. Am J Neuroradiol. 1999;20:1842–50.PubMed Reichenbach JR, Röther J, Jonetz-Mentzel L, Herzau M, Fiala A, Weiller C, et al. Acute stroke evaluated by time-to-peak mapping during initial and early follow-up perfusion CT studies. Am J Neuroradiol. 1999;20:1842–50.PubMed
17.
Zurück zum Zitat Olivot JM, Mlynash M, Thijs VN, Kemp S, Lansberg MG, Wechsler L, et al. Optimal Tmax threshold for predicting penumbral tissue in acute stroke. Stroke. 2009;40:469–75.CrossRefPubMed Olivot JM, Mlynash M, Thijs VN, Kemp S, Lansberg MG, Wechsler L, et al. Optimal Tmax threshold for predicting penumbral tissue in acute stroke. Stroke. 2009;40:469–75.CrossRefPubMed
18.
Zurück zum Zitat Donnan GA, Baron JC, Ma H, Davis SM. Penumbral selection of patients for trials of acute stroke therapy. Lancet Neurol. 2009;8:261–9.CrossRefPubMed Donnan GA, Baron JC, Ma H, Davis SM. Penumbral selection of patients for trials of acute stroke therapy. Lancet Neurol. 2009;8:261–9.CrossRefPubMed
19.
Zurück zum Zitat Calamante F, Christensen S, Desmond PM, Østergaard L, Davis SM, Connelly A. The physiological significance of the time-to-maximum (Tmax) parameter in perfusion MRI. Stroke. 2010;41:1169–74.CrossRefPubMed Calamante F, Christensen S, Desmond PM, Østergaard L, Davis SM, Connelly A. The physiological significance of the time-to-maximum (Tmax) parameter in perfusion MRI. Stroke. 2010;41:1169–74.CrossRefPubMed
20.
Zurück zum Zitat Calamante F, Thomas DL, Pell GS, Wiersma J, Turner R. Measuring cerebral blood flow using magnetic resonance imaging techniques. J Cereb Blood Flow Metab. 1999;19:701–35.CrossRefPubMed Calamante F, Thomas DL, Pell GS, Wiersma J, Turner R. Measuring cerebral blood flow using magnetic resonance imaging techniques. J Cereb Blood Flow Metab. 1999;19:701–35.CrossRefPubMed
Metadaten
Titel
Quantitative accuracy of computed tomography perfusion under low-dose conditions, measured using a hollow-fiber phantom
verfasst von
Kazufumi Suzuki
Hiroyuki Hashimoto
Eiji Okaniwa
Hiroshi Iimura
Shingo Suzaki
Kayoko Abe
Shuji Sakai
Publikationsdatum
27.04.2017
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 7/2017
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-017-0642-y

Weitere Artikel der Ausgabe 7/2017

Japanese Journal of Radiology 7/2017 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.