Skip to main content
Erschienen in: Surgical and Radiologic Anatomy 8/2012

01.10.2012 | Review

Recent advances in medical imaging: anatomical and clinical applications

verfasst von: Bruno Grignon, Laurence Mainard, Matthieu Delion, Claude Hodez, Guillaume Oldrini

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 8/2012

Einloggen, um Zugang zu erhalten

Abstract

The aim of this paper was to present an overview of the most important recent advances in medical imaging and their potential clinical and anatomical applications. Dramatic changes have been particularly observed in the field of computed tomography (CT) and magnetic resonance imaging (MRI). Computed tomography (CT) has been completely overturned by the successive development of helical acquisition, multidetector and large area-detector acquisition. Visualising brain function has become a new challenge for MRI, which is called functional MRI, currently based principally on blood oxygenation level-dependent sequences, which could be completed or replaced by other techniques such as diffusion MRI (DWI). Based on molecular diffusion due to the thermal energy of free water, DWI offers a spectrum of anatomical and clinical applications, ranging from brain ischemia to visualisation of large fibrous structures of the human body such as the anatomical bundles of white matter with diffusion tensor imaging and tractography. In the field of X-ray projection imaging, a new low-dose device called EOS has been developed through new highly sensitive detectors of X-rays, allowing for acquiring frontal and lateral images simultaneously. Other improvements have been briefly mentioned. Technical principles have been considered in order to understand what is most useful in clinical practice as well as in the field of anatomical applications. Nuclear medicine has not been included.
Literatur
1.
Zurück zum Zitat Achenbach S, Anders K, Kalender W (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198PubMedCrossRef Achenbach S, Anders K, Kalender W (2008) Dual-source cardiac computed tomography: image quality and dose considerations. Eur Radiol 18:1188–1198PubMedCrossRef
2.
Zurück zum Zitat Andreisek G, White LM, Kassner A, Sussman MS (2010) Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: preliminary results on intrasubject variability and precision of measurements. AJR Am J Roentgenol 194:W65–W72PubMedCrossRef Andreisek G, White LM, Kassner A, Sussman MS (2010) Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: preliminary results on intrasubject variability and precision of measurements. AJR Am J Roentgenol 194:W65–W72PubMedCrossRef
3.
Zurück zum Zitat Asaumi R, Sato I, Miwa Y, Imura K, Sunohara M, Kawai T, Yosue T (2010) Understanding the formation of maxillary sinus in Japanese human foetuses using cone beam CT. Surg Radiol Anat 32:745–751PubMedCrossRef Asaumi R, Sato I, Miwa Y, Imura K, Sunohara M, Kawai T, Yosue T (2010) Understanding the formation of maxillary sinus in Japanese human foetuses using cone beam CT. Surg Radiol Anat 32:745–751PubMedCrossRef
4.
Zurück zum Zitat Azmy C, Guérard S, Bonnet X, Gabrielli F, Skalli W (2010) EOS® orthopaedic imaging system to study patellofemoral kinematics: assessment of uncertainty. Rev Chir Orthop Traum 96:23–32 Azmy C, Guérard S, Bonnet X, Gabrielli F, Skalli W (2010) EOS® orthopaedic imaging system to study patellofemoral kinematics: assessment of uncertainty. Rev Chir Orthop Traum 96:23–32
5.
Zurück zum Zitat Balbi V, Budzik J-F, Duhamel A, Bera-Louville A, Le Thuc V, Cotten A (2011) Tractography of lumbar nerve roots: initial results. Eur Radiology 21:1153–1159CrossRef Balbi V, Budzik J-F, Duhamel A, Bera-Louville A, Le Thuc V, Cotten A (2011) Tractography of lumbar nerve roots: initial results. Eur Radiology 21:1153–1159CrossRef
6.
Zurück zum Zitat Billuart F, Devun L, Skalli W, Mitton D, Gagey O (2008) Role of deltoid and passives elements in stabilization during abduction motion (0°–40°): an ex vivo study. Surg Radiol Anat 30:563–568PubMedCrossRef Billuart F, Devun L, Skalli W, Mitton D, Gagey O (2008) Role of deltoid and passives elements in stabilization during abduction motion (0°–40°): an ex vivo study. Surg Radiol Anat 30:563–568PubMedCrossRef
7.
Zurück zum Zitat Brouwer RW, Jakma TSBK, Verhaar JA (2007) Pitfalls in determining knee alignment: a radiographic cadaver study. J Knee Surg 20:210–215PubMed Brouwer RW, Jakma TSBK, Verhaar JA (2007) Pitfalls in determining knee alignment: a radiographic cadaver study. J Knee Surg 20:210–215PubMed
8.
Zurück zum Zitat Catalano C, Passariello R (2005) Multidetector-row CT angiography. Springer, BerlinCrossRef Catalano C, Passariello R (2005) Multidetector-row CT angiography. Springer, BerlinCrossRef
9.
Zurück zum Zitat Chaibi Y, Cresson TAB, Hausselle J, Neyret P, Hauger O, de Guise JA, Skalli W (2011) Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Eng 1:1 Chaibi Y, Cresson TAB, Hausselle J, Neyret P, Hauger O, de Guise JA, Skalli W (2011) Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput Methods Biomech Biomed Eng 1:1
10.
Zurück zum Zitat Chen SH, Chen MM, Xu DC, He H, Peng TH, Tan JG, Xiang YY (2011) Anatomical study to the vessels of the lower limb by using CT scan and 3D reconstructions of the injected material. Surg Radiol Anat 33:45–51PubMedCrossRef Chen SH, Chen MM, Xu DC, He H, Peng TH, Tan JG, Xiang YY (2011) Anatomical study to the vessels of the lower limb by using CT scan and 3D reconstructions of the injected material. Surg Radiol Anat 33:45–51PubMedCrossRef
11.
Zurück zum Zitat Christensen K, Harris S, Froemming A, Brinjikji W, Araoz P, Asirvatham S, Lachman N (2010) Anatomic assessment of the bifurcation of the left main coronary artery using multidetector computed tomography. Surg Radiol Anat 32:903–909PubMedCrossRef Christensen K, Harris S, Froemming A, Brinjikji W, Araoz P, Asirvatham S, Lachman N (2010) Anatomic assessment of the bifurcation of the left main coronary artery using multidetector computed tomography. Surg Radiol Anat 32:903–909PubMedCrossRef
12.
Zurück zum Zitat da Silva Ramos Fernandes L, Capelozza A, Rubira-Bullen I (2011) Absence and hypoplasia of the mental foramen detected in CBCT images: a case report. Surg Radiol Anat 33:731–734PubMedCrossRef da Silva Ramos Fernandes L, Capelozza A, Rubira-Bullen I (2011) Absence and hypoplasia of the mental foramen detected in CBCT images: a case report. Surg Radiol Anat 33:731–734PubMedCrossRef
13.
Zurück zum Zitat Deschenes S, Charron G, Beaudoin G, Labelle H, Dubois J, Miron MC, Parent S (2010) Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager. Spine (Phila Pa 1976) 35:989–994CrossRef Deschenes S, Charron G, Beaudoin G, Labelle H, Dubois J, Miron MC, Parent S (2010) Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager. Spine (Phila Pa 1976) 35:989–994CrossRef
14.
Zurück zum Zitat Dixon WT (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging: a modest proposal with tremendous potential. Radiology 168:566–567PubMed Dixon WT (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging: a modest proposal with tremendous potential. Radiology 168:566–567PubMed
15.
Zurück zum Zitat Dramsdahl M, Westerhausen R, Haavik J, Hugdahl K, Plessen KJ (2012) Adults with attention-deficit/hyperactivity disorder—a diffusion-tensor imaging study of the corpus callosum. Psychiatry Res 201:168–173PubMedCrossRef Dramsdahl M, Westerhausen R, Haavik J, Hugdahl K, Plessen KJ (2012) Adults with attention-deficit/hyperactivity disorder—a diffusion-tensor imaging study of the corpus callosum. Psychiatry Res 201:168–173PubMedCrossRef
16.
Zurück zum Zitat Dubousset J, Charpak G, Skalli W, Kalifa G, Lazennec JY (2007) EOS stereo-radiography system: whole-body simultaneous anteroposterior and lateral radiographs with very low radiation dose. Rev Chir Orthop Reparatrice Appar Mot 93:141–143PubMedCrossRef Dubousset J, Charpak G, Skalli W, Kalifa G, Lazennec JY (2007) EOS stereo-radiography system: whole-body simultaneous anteroposterior and lateral radiographs with very low radiation dose. Rev Chir Orthop Reparatrice Appar Mot 93:141–143PubMedCrossRef
17.
Zurück zum Zitat Fornaro J, Leschka S, Hibbeln D, Butler A, Anderson N, Pache G, Scheffel H, Wildermuth S, Alkadhi H, Stolzmann P (2011) Dual- and multi-energy CT: approach to functional imaging. Insights Imaging 2:149–159PubMedCrossRef Fornaro J, Leschka S, Hibbeln D, Butler A, Anderson N, Pache G, Scheffel H, Wildermuth S, Alkadhi H, Stolzmann P (2011) Dual- and multi-energy CT: approach to functional imaging. Insights Imaging 2:149–159PubMedCrossRef
18.
Zurück zum Zitat Gheno R, Nectoux E, Herbaux B, Baldisserotto M, Glock L, Cotten A, Boutry N (2012) Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device. Eur Radiol 22:765–771PubMedCrossRef Gheno R, Nectoux E, Herbaux B, Baldisserotto M, Glock L, Cotten A, Boutry N (2012) Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device. Eur Radiol 22:765–771PubMedCrossRef
19.
Zurück zum Zitat Goshima S, Kanematsu M, Nishibori H, Sakurai K, Miyazawa D, Watanabe H, Kondo H, Shiratori Y, Onozuka M, Moriyama N, Bae KT (2011) CT of the pancreas: comparison of anatomic structure depiction, image quality, and radiation exposure between 320-detector volumetric images and 64-detector helical images. Radiology 260:139–147PubMedCrossRef Goshima S, Kanematsu M, Nishibori H, Sakurai K, Miyazawa D, Watanabe H, Kondo H, Shiratori Y, Onozuka M, Moriyama N, Bae KT (2011) CT of the pancreas: comparison of anatomic structure depiction, image quality, and radiation exposure between 320-detector volumetric images and 64-detector helical images. Radiology 260:139–147PubMedCrossRef
20.
Zurück zum Zitat Hendrikse J, Petersen ET, Chng SM, Venketasubramanian N, Golay X (2010) Distribution of cerebral blood flow in the nucleus caudatus, nucleus lentiformis, and thalamus: a study of territorial arterial spin-labeling MR imaging. Radiology 254:867–875PubMedCrossRef Hendrikse J, Petersen ET, Chng SM, Venketasubramanian N, Golay X (2010) Distribution of cerebral blood flow in the nucleus caudatus, nucleus lentiformis, and thalamus: a study of territorial arterial spin-labeling MR imaging. Radiology 254:867–875PubMedCrossRef
21.
Zurück zum Zitat Hsiao E, Rybicki F, Steigner M (2010) CT coronary angiography: 256-slice and 320-detector row scanners. Curr Cardiol Rep 12:68–75PubMedCrossRef Hsiao E, Rybicki F, Steigner M (2010) CT coronary angiography: 256-slice and 320-detector row scanners. Curr Cardiol Rep 12:68–75PubMedCrossRef
22.
Zurück zum Zitat Ilharreborde B, Steffen JSNE, Vital JM, Mazda K, Skalli W, Obeid I (2011) Angle measurement reproducibility using EOS three-dimensional reconstructions in adolescent idiopathic scoliosis treated by posterior instrumentation. Spine (Phila Pa 1976) 36:E1306–E1313CrossRef Ilharreborde B, Steffen JSNE, Vital JM, Mazda K, Skalli W, Obeid I (2011) Angle measurement reproducibility using EOS three-dimensional reconstructions in adolescent idiopathic scoliosis treated by posterior instrumentation. Spine (Phila Pa 1976) 36:E1306–E1313CrossRef
23.
Zurück zum Zitat Jambawalikar S, Baum J, Button T, Li H, Geronimo V, Gould E (2010) Diffusion tensor imaging of peripheral nerves. Skelet Radiol 39:1073–1079CrossRef Jambawalikar S, Baum J, Button T, Li H, Geronimo V, Gould E (2010) Diffusion tensor imaging of peripheral nerves. Skelet Radiol 39:1073–1079CrossRef
24.
Zurück zum Zitat Johnson T, Krauß B, Sedlmair M, Grasruck M, Bruder H, Morhard D, Fink C, Weckbach S, Lenhard M, Schmidt B, Flohr T, Reiser M, Becker C (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517PubMedCrossRef Johnson T, Krauß B, Sedlmair M, Grasruck M, Bruder H, Morhard D, Fink C, Weckbach S, Lenhard M, Schmidt B, Flohr T, Reiser M, Becker C (2007) Material differentiation by dual energy CT: initial experience. Eur Radiol 17:1510–1517PubMedCrossRef
25.
26.
Zurück zum Zitat Kalifa G, Charpak Y, Maccia C, Fery-Lemonnier E, Bloch J, Boussard J-M, Attal M, Dubousset J, Adamsbaum C (1998) Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children. Pediatric Radiol 28:557–561CrossRef Kalifa G, Charpak Y, Maccia C, Fery-Lemonnier E, Bloch J, Boussard J-M, Attal M, Dubousset J, Adamsbaum C (1998) Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children. Pediatric Radiol 28:557–561CrossRef
27.
Zurück zum Zitat Karampinos DC, Banerjee S, King KF, Link TM, Majumdar S (2012) Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding. NMR Biomed 25:766–778PubMedCrossRef Karampinos DC, Banerjee S, King KF, Link TM, Majumdar S (2012) Considerations in high-resolution skeletal muscle diffusion tensor imaging using single-shot echo planar imaging with stimulated-echo preparation and sensitivity encoding. NMR Biomed 25:766–778PubMedCrossRef
28.
Zurück zum Zitat Kerl J, Bauer R, Maurer T, Aschenbach R, Korkusuz H, Lehnert T, Deseive S, Ackermann H, Vogl T (2011) Dose levels at coronary CT angiography—a comparison of dual energy-, dual source- and 16-slice CT. Eur Radiol 21:530–537PubMedCrossRef Kerl J, Bauer R, Maurer T, Aschenbach R, Korkusuz H, Lehnert T, Deseive S, Ackermann H, Vogl T (2011) Dose levels at coronary CT angiography—a comparison of dual energy-, dual source- and 16-slice CT. Eur Radiol 21:530–537PubMedCrossRef
29.
Zurück zum Zitat Kitagawa K, Lardo A, Lima J, George R (2009) Prospective ECG-gated 320 row detector computed tomography: implications for CT angiography and perfusion imaging. Int J Cardiovasc Imaging 25:201–208CrossRef Kitagawa K, Lardo A, Lima J, George R (2009) Prospective ECG-gated 320 row detector computed tomography: implications for CT angiography and perfusion imaging. Int J Cardiovasc Imaging 25:201–208CrossRef
30.
Zurück zum Zitat Lambregts DMJ, Maas M, Cappendijk VC, Prompers LM, Mottaghy FM, Beets GL, Beets-Tan RGH (2011) Whole-body diffusion-weighted magnetic resonance imaging: current evidence in oncology and potential role in colorectal cancer staging. Eur J Cancer 47:2107–2116PubMedCrossRef Lambregts DMJ, Maas M, Cappendijk VC, Prompers LM, Mottaghy FM, Beets GL, Beets-Tan RGH (2011) Whole-body diffusion-weighted magnetic resonance imaging: current evidence in oncology and potential role in colorectal cancer staging. Eur J Cancer 47:2107–2116PubMedCrossRef
31.
Zurück zum Zitat Lazennec JY, Rangel A, Baudoin A, Skalli W, Catonne Y, Rousseau MA (2011) The EOS imaging system for understanding a patellofemoral disorder following THR. Orthop Traumatol Surg Res 97:98–101PubMedCrossRef Lazennec JY, Rangel A, Baudoin A, Skalli W, Catonne Y, Rousseau MA (2011) The EOS imaging system for understanding a patellofemoral disorder following THR. Orthop Traumatol Surg Res 97:98–101PubMedCrossRef
32.
Zurück zum Zitat Lazennec JY, Rousseau MA, Rangel A, Gorin M, Belicourt C, Brusson A, Catonné Y (2011) Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: measurements reproductibility with EOS imaging system versus conventional radiographies. Orthop Traumatol Surg Res 97:373–380PubMedCrossRef Lazennec JY, Rousseau MA, Rangel A, Gorin M, Belicourt C, Brusson A, Catonné Y (2011) Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: measurements reproductibility with EOS imaging system versus conventional radiographies. Orthop Traumatol Surg Res 97:373–380PubMedCrossRef
34.
Zurück zum Zitat Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407PubMed Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval-Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401–407PubMed
36.
Zurück zum Zitat Machida H, Yuhara T, Mori T, Ueno E, Moribe Y, Sabol JM (2010) Optimizing parameters for flat-panel detector digital tomosynthesis. Radiographics 30:549–562PubMedCrossRef Machida H, Yuhara T, Mori T, Ueno E, Moribe Y, Sabol JM (2010) Optimizing parameters for flat-panel detector digital tomosynthesis. Radiographics 30:549–562PubMedCrossRef
37.
Zurück zum Zitat Mah JK, Yi L, Huang RC, Choo H (2011) Advanced applications of cone beam computed tomography in orthodontics. Semin Orthod 17:57–71CrossRef Mah JK, Yi L, Huang RC, Choo H (2011) Advanced applications of cone beam computed tomography in orthodontics. Semin Orthod 17:57–71CrossRef
38.
Zurück zum Zitat Miracle AC, Mukherji SK (2009) Conebeam CT of the head and neck, part 1: physical principles. AJNR Am J Neuroradiol 30:1088–1095PubMedCrossRef Miracle AC, Mukherji SK (2009) Conebeam CT of the head and neck, part 1: physical principles. AJNR Am J Neuroradiol 30:1088–1095PubMedCrossRef
39.
Zurück zum Zitat Miracle AC, Mukherjia SK (2009) Conebeam CT of the head and neck, part 2: clinical applications. AJNR Am J Neuroradiol 30:1285–1292PubMedCrossRef Miracle AC, Mukherjia SK (2009) Conebeam CT of the head and neck, part 2: clinical applications. AJNR Am J Neuroradiol 30:1285–1292PubMedCrossRef
40.
Zurück zum Zitat Morvan G, Mathieu P, Vuillemin V, Guerini H, Bossard P, Zeitoun F, Wybier M (2011) Standardized way for imaging of the sagittal spinal balance. Eur Spine J 20:602–608PubMedCrossRef Morvan G, Mathieu P, Vuillemin V, Guerini H, Bossard P, Zeitoun F, Wybier M (2011) Standardized way for imaging of the sagittal spinal balance. Eur Spine J 20:602–608PubMedCrossRef
41.
Zurück zum Zitat Mozzo P, Procacci C, Tacconi A, Tinazzi Martini P, Bergamo Andreis IA (1998) A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8:1558–1564PubMedCrossRef Mozzo P, Procacci C, Tacconi A, Tinazzi Martini P, Bergamo Andreis IA (1998) A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 8:1558–1564PubMedCrossRef
42.
Zurück zum Zitat Mueller S, Keeser D, Reiser MF, Teipel S, Meindl T (2012) Functional and structural MR imaging in neuropsychiatric disorders, Part 1: imaging techniques and their application in mild cognitive impairment and Alzheimer disease. AJNR Am J Neuroradiol. doi:10.3174/ajnr.A2799 Mueller S, Keeser D, Reiser MF, Teipel S, Meindl T (2012) Functional and structural MR imaging in neuropsychiatric disorders, Part 1: imaging techniques and their application in mild cognitive impairment and Alzheimer disease. AJNR Am J Neuroradiol. doi:10.​3174/​ajnr.​A2799
43.
Zurück zum Zitat Mueller S, Keeser D, Reiser MF, Teipel S, Meindl T (2012) Functional and structural MR imaging in neuropsychiatric disorders, Part 2: application in schizophrenia and autism. AJNR Am J Neuroradiol. doi:10.3174/ajnr.A2800 Mueller S, Keeser D, Reiser MF, Teipel S, Meindl T (2012) Functional and structural MR imaging in neuropsychiatric disorders, Part 2: application in schizophrenia and autism. AJNR Am J Neuroradiol. doi:10.​3174/​ajnr.​A2800
44.
Zurück zum Zitat Ohl X, Stanchina C, Billuart F, Skalli W (2010) Shoulder bony landmarks location using the EOS® low-dose stereoradiography system: a reproducibility study. Surg Radiol Anat 32:153–158PubMedCrossRef Ohl X, Stanchina C, Billuart F, Skalli W (2010) Shoulder bony landmarks location using the EOS® low-dose stereoradiography system: a reproducibility study. Surg Radiol Anat 32:153–158PubMedCrossRef
45.
Zurück zum Zitat Orhan K, Aksoy S, Bilecenoglu B, Sakul B, Paksoy C (2011) Evaluation of bifid mandibular canals with cone-beam computed tomography in a Turkish adult population: a retrospective study. Surg Radiol Anat 33:501–507PubMedCrossRef Orhan K, Aksoy S, Bilecenoglu B, Sakul B, Paksoy C (2011) Evaluation of bifid mandibular canals with cone-beam computed tomography in a Turkish adult population: a retrospective study. Surg Radiol Anat 33:501–507PubMedCrossRef
46.
Zurück zum Zitat Orrison WW Jr, Snyder KV, Hopkins LN, Roach CJ, Ringdahl EN, Nazir R, Hanson EH (2011) Whole-brain dynamic CT angiography and perfusion imaging. Clin Radiol 66:566–574PubMedCrossRef Orrison WW Jr, Snyder KV, Hopkins LN, Roach CJ, Ringdahl EN, Nazir R, Hanson EH (2011) Whole-brain dynamic CT angiography and perfusion imaging. Clin Radiol 66:566–574PubMedCrossRef
47.
Zurück zum Zitat Orth RC, Wallace MJ, Kuo MD (2008) C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol 19:814–820PubMedCrossRef Orth RC, Wallace MJ, Kuo MD (2008) C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol 19:814–820PubMedCrossRef
48.
Zurück zum Zitat Ozturk E, Duran C, Sonmez G, Sildiroglu H, Velioglu M, Bozlar U, Hagspiel K (2011) Arterial supply of the posterior interventricular sulcus: a CT coronary angiographic study. Surg Radiol Anat 33:27–34PubMedCrossRef Ozturk E, Duran C, Sonmez G, Sildiroglu H, Velioglu M, Bozlar U, Hagspiel K (2011) Arterial supply of the posterior interventricular sulcus: a CT coronary angiographic study. Surg Radiol Anat 33:27–34PubMedCrossRef
49.
Zurück zum Zitat Robb RA (1982) The dynamic spatial reconstructor: an X-ray video-fluoroscopic CT scanner for dynamic volume imaging of moving organs. IEEE Trans Med Imaging 1:22–33PubMedCrossRef Robb RA (1982) The dynamic spatial reconstructor: an X-ray video-fluoroscopic CT scanner for dynamic volume imaging of moving organs. IEEE Trans Med Imaging 1:22–33PubMedCrossRef
50.
Zurück zum Zitat Scarabino T, Salvolini U, Jinkins JR (2006) Emergency neuroradiology. Springer, BerlinCrossRef Scarabino T, Salvolini U, Jinkins JR (2006) Emergency neuroradiology. Springer, BerlinCrossRef
51.
Zurück zum Zitat Sodickson A, Baeyens PF, Andriole KP, Prevedello LM, Nawfel RD, Hanson R, Khorasani R (2009) Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults1. Radiology 251:175–184PubMedCrossRef Sodickson A, Baeyens PF, Andriole KP, Prevedello LM, Nawfel RD, Hanson R, Khorasani R (2009) Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults1. Radiology 251:175–184PubMedCrossRef
52.
Zurück zum Zitat Sunaert S (2006) Presurgical planning for tumor resectioning. J Magn Reson Imaging 23:887–905PubMedCrossRef Sunaert S (2006) Presurgical planning for tumor resectioning. J Magn Reson Imaging 23:887–905PubMedCrossRef
53.
Zurück zum Zitat Tagliafico A, Calabrese M, Puntoni M, Pace D, Baio G, Neumaier C, Martinoli C (2011) Brachial plexus MR imaging: accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T. Eur Radiol 21:1764–1771PubMedCrossRef Tagliafico A, Calabrese M, Puntoni M, Pace D, Baio G, Neumaier C, Martinoli C (2011) Brachial plexus MR imaging: accuracy and reproducibility of DTI-derived measurements and fibre tractography at 3.0-T. Eur Radiol 21:1764–1771PubMedCrossRef
54.
Zurück zum Zitat Than P, Szuper K, Somoskeöy S, Warta V, Illés T (2011) Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system. Int Orthop. doi:10.1007/s000264-011-1403-7 Than P, Szuper K, Somoskeöy S, Warta V, Illés T (2011) Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system. Int Orthop. doi:10.​1007/​s000264-011-1403-7
55.
Zurück zum Zitat Tieleman A, Deblaere K, Van Roost D, Van Damme O, Achten E (2009) Preoperative fMRI in tumour surgery. Eur Radiol 19:2523–2534PubMedCrossRef Tieleman A, Deblaere K, Van Roost D, Van Damme O, Achten E (2009) Preoperative fMRI in tumour surgery. Eur Radiol 19:2523–2534PubMedCrossRef
56.
Zurück zum Zitat Zijta F, Froeling M, van der Paardt M, Lakeman M, Bipat S, Montauban van Swijndregt A, Strijkers G, Nederveen A, Stoker J (2011) Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor. Eur Radiol 21:1243–1249PubMedCrossRef Zijta F, Froeling M, van der Paardt M, Lakeman M, Bipat S, Montauban van Swijndregt A, Strijkers G, Nederveen A, Stoker J (2011) Feasibility of diffusion tensor imaging (DTI) with fibre tractography of the normal female pelvic floor. Eur Radiol 21:1243–1249PubMedCrossRef
Metadaten
Titel
Recent advances in medical imaging: anatomical and clinical applications
verfasst von
Bruno Grignon
Laurence Mainard
Matthieu Delion
Claude Hodez
Guillaume Oldrini
Publikationsdatum
01.10.2012
Verlag
Springer-Verlag
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 8/2012
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-012-0985-0

Weitere Artikel der Ausgabe 8/2012

Surgical and Radiologic Anatomy 8/2012 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.