Erschienen in:
19.01.2017 | Original Article
T1 mapping using saturation recovery single-shot acquisition at 3-tesla magnetic resonance imaging in hypertrophic cardiomyopathy: comparison to late gadolinium enhancement
verfasst von:
Ryo Ogawa, Tomoyuki Kido, Masashi Nakamura, Teruhito Kido, Akira Kurata, Teruyoshi Uetani, Akiyoshi Ogimoto, Masao Miyagawa, Teruhito Mochizuki
Erschienen in:
Japanese Journal of Radiology
|
Ausgabe 3/2017
Einloggen, um Zugang zu erhalten
Abstract
Purpose
We evaluated the T1 values of segments and slices and the reproducibility in healthy controls, using saturation recovery single-shot acquisition (SASHA) at 3T magnetic resonance imaging. Moreover, we examined the difference in T1 values between hypertrophic cardiomyopathy (HCM) and healthy controls, and compared those with late gadolinium enhancement (LGE).
Materials and methods
Twenty-one HCM patients and 10 healthy controls underwent T1 mapping before and after contrast administration. T1 values were measured in 12 segments.
Results
Native T1 values were significantly longer in HCM than in healthy controls [1373 ms (1312–1452 ms) vs. 1279 ms (1229–1326 ms); p < 0.0001]. Even in HCM segments without LGE, native T1 values were significantly longer than in healthy control segments [1366 ms (1300–1439 ms) vs. 1279 ms (1229–1326 ms); p < 0.0001]. Using a cutoff value of 1327 ms for septal native T1 values, we differentiated between HCM and healthy controls with 95% sensitivity, 90% specificity, 94% accuracy, and an area under the curve of 0.95.
Conclusions
Native T1 values using a SASHA at 3T could differentiate HCM from healthy controls. Moreover, native T1 values have the potential to detect abnormal myocardium that cannot be identified adequately by LGE in HCM.