Skip to main content
Erschienen in: European Radiology 8/2009

01.08.2009 | Contrast Media

Thoracic and abdominal MRA with gadofosveset: Influence of injection rate on vessel signal and image quality

verfasst von: Johanna C. Nissen, Ulrike I. Attenberger, Christian Fink, Olaf Dietrich, Martin Rohrer, Stefan O. Schoenberg, Henrik J. Michaely

Erschienen in: European Radiology | Ausgabe 8/2009

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to investigate the influence of different injection rates on the maximum signal intensity and the arterio-venous transit time of dynamic gadofosveset-enhanced first pass MR angiography (MRA). Twenty-one healthy male volunteers were examined with a time-resolved echo-shared MRA at 1.5 T. The volunteers were assigned into three groups using injection rates of either 1, 2 or 4 ml/s. The maximal signal enhancement and peak signal-to-noise ratio in the pulmonary trunk, the aortic arch, the abdominal aorta as well as both kidneys and lung parenchyma were analyzed. The arterio-venous transit time was determined. The time between maximal enhancement of the pulmonary trunk and the aortic arch was higher with the slow injection rate of 1 ml/s, while there were no differences in the time between maximal enhancement of the aortic arch and the abdominal aorta above or below the origin of the renal veins with all three injection rates. With the slow injection protocol of 1 ml/s a longer purely arterial phase of 10.5 s was achieved compared to 7.7 s with higher injection rates (p = 0.045). The time between maximal aortic signal intensity and maximal renal enhancement was equal for all injection protocols.
Literatur
1.
Zurück zum Zitat Lauffer RB, Parmelee DJ, Dunham SU et al (1998) MS-325: albumin-targeted contrast agent for MR angiography. Radiology 207:529–538PubMed Lauffer RB, Parmelee DJ, Dunham SU et al (1998) MS-325: albumin-targeted contrast agent for MR angiography. Radiology 207:529–538PubMed
2.
Zurück zum Zitat Rohrer M (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef Rohrer M (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef
3.
Zurück zum Zitat Caravan P, Parigi G, Chasse JM et al (2007) Albumin binding, relaxivity, and water exchange kinetics of the diastereoisomers of MS-325, a gadolinium(III)-based magnetic resonance angiography contrast agent. Inorg Chem 46:6632–6639PubMedCrossRef Caravan P, Parigi G, Chasse JM et al (2007) Albumin binding, relaxivity, and water exchange kinetics of the diastereoisomers of MS-325, a gadolinium(III)-based magnetic resonance angiography contrast agent. Inorg Chem 46:6632–6639PubMedCrossRef
4.
Zurück zum Zitat Klessen C, Hein PA, Huppertz A et al (2007) First-pass whole-body magnetic resonance angiography (mra) using the blood-pool contrast medium gadofosveset trisodium: comparison to gadopentetate dimeglumine. Invest Radiol 42:659–664PubMedCrossRef Klessen C, Hein PA, Huppertz A et al (2007) First-pass whole-body magnetic resonance angiography (mra) using the blood-pool contrast medium gadofosveset trisodium: comparison to gadopentetate dimeglumine. Invest Radiol 42:659–664PubMedCrossRef
5.
Zurück zum Zitat Hartmann M, Wiethoff AJ, Hentrich HR, Rohrer M (2006) Initial imaging recommendations for Vasovist angiography. Eur Radiol 16(Suppl 2):B15–B23PubMed Hartmann M, Wiethoff AJ, Hentrich HR, Rohrer M (2006) Initial imaging recommendations for Vasovist angiography. Eur Radiol 16(Suppl 2):B15–B23PubMed
6.
Zurück zum Zitat Grist TM, Korosec FR, Peters DC et al (1998) Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 207:539–544PubMed Grist TM, Korosec FR, Peters DC et al (1998) Steady-state and dynamic MR angiography with MS-325: initial experience in humans. Radiology 207:539–544PubMed
7.
Zurück zum Zitat Hartmann M (2006) Initial imaging recommendations for Vasovist angiography. Eur Radiol 16(Suppl 2):B15–B23PubMed Hartmann M (2006) Initial imaging recommendations for Vasovist angiography. Eur Radiol 16(Suppl 2):B15–B23PubMed
8.
Zurück zum Zitat Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef Rohrer M, Bauer H, Mintorovitch J, Requardt M, Weinmann HJ (2005) Comparison of magnetic properties of MRI contrast media solutions at different magnetic field strengths. Invest Radiol 40:715–724PubMedCrossRef
9.
Zurück zum Zitat Caravan P, Cloutier NJ, Greenfield MT et al (2002) The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates. J Am Chem Soc 124:3152–3162PubMedCrossRef Caravan P, Cloutier NJ, Greenfield MT et al (2002) The interaction of MS-325 with human serum albumin and its effect on proton relaxation rates. J Am Chem Soc 124:3152–3162PubMedCrossRef
10.
Zurück zum Zitat Eldredge HB, Spiller M, Chasse JM, Greenwood MT, Caravan P (2006) Species dependence on plasma protein binding and relaxivity of the gadolinium-based MRI contrast agent MS-325. Invest Radiol 41:229–243PubMedCrossRef Eldredge HB, Spiller M, Chasse JM, Greenwood MT, Caravan P (2006) Species dependence on plasma protein binding and relaxivity of the gadolinium-based MRI contrast agent MS-325. Invest Radiol 41:229–243PubMedCrossRef
11.
Zurück zum Zitat Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202–1210PubMedCrossRef Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47:1202–1210PubMedCrossRef
12.
Zurück zum Zitat Korosec FR, Frayne R, Grist TM, Mistretta CA (1996) Time-resolved contrast-enhanced 3D MR angiography. Magn Reson Med 36:345–351PubMedCrossRef Korosec FR, Frayne R, Grist TM, Mistretta CA (1996) Time-resolved contrast-enhanced 3D MR angiography. Magn Reson Med 36:345–351PubMedCrossRef
13.
Zurück zum Zitat Fink C, Ley S, Kroeker R et al (2005) Time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the chest: combination of parallel imaging with view sharing (TREAT). Invest Radiol 40:40–48PubMedCrossRef Fink C, Ley S, Kroeker R et al (2005) Time-resolved contrast-enhanced three-dimensional magnetic resonance angiography of the chest: combination of parallel imaging with view sharing (TREAT). Invest Radiol 40:40–48PubMedCrossRef
14.
Zurück zum Zitat Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375–385PubMedCrossRef Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26:375–385PubMedCrossRef
15.
Zurück zum Zitat Fink C, Puderbach M, Ley S et al (2004) Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels. Invest Radiol 39:143–148PubMedCrossRef Fink C, Puderbach M, Ley S et al (2004) Contrast-enhanced three-dimensional pulmonary perfusion magnetic resonance imaging: intraindividual comparison of 1.0 M gadobutrol and 0.5 M Gd-DTPA at three dose levels. Invest Radiol 39:143–148PubMedCrossRef
16.
Zurück zum Zitat Johnson TR, Nikolaou K, Wintersperger BJ et al (2007) Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest. J Comput Assist Tomogr 31:265–271PubMedCrossRef Johnson TR, Nikolaou K, Wintersperger BJ et al (2007) Optimization of contrast material administration for electrocardiogram-gated computed tomographic angiography of the chest. J Comput Assist Tomogr 31:265–271PubMedCrossRef
Metadaten
Titel
Thoracic and abdominal MRA with gadofosveset: Influence of injection rate on vessel signal and image quality
verfasst von
Johanna C. Nissen
Ulrike I. Attenberger
Christian Fink
Olaf Dietrich
Martin Rohrer
Stefan O. Schoenberg
Henrik J. Michaely
Publikationsdatum
01.08.2009
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 8/2009
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-009-1381-y

Weitere Artikel der Ausgabe 8/2009

European Radiology 8/2009 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.