Skip to main content
Erschienen in: Neurological Sciences 3/2017

01.03.2017 | Brief Communication

Ultra-high magnetic resonance imaging (MRI): a potential examination for deep brain stimulation devices and the limitation study concerning MRI-related heating injury

verfasst von: Ying-Chuan Chen, Jun-Ju Li, Guan-Yu Zhu, Lin Shi, An-Chao Yang, Yin Jiang, Xin Zhang, Jian-Guo Zhang

Erschienen in: Neurological Sciences | Ausgabe 3/2017

Einloggen, um Zugang zu erhalten

Abstract

Nowadays, the patients with deep brain stimulation (DBS) devices are restricted to undertake 1.5T magnetic resonance imaging (MRI) according to the guideline. Nevertheless, we conducted an experiment to test pathological change near the leads in different field-strength MRI. Twenty-four male New Zealand rabbits were assigned to Group 1 (G1, n = 6, 7.0T, DBS), Group 2 (G2, n = 6, 3.0T, DBS), Group 3 (G3, n = 6, 1.5T, DBS), and Group 4 (G4, n = 6, 1.5T, paracentesis). DBS leads were implanted in G1, G2 and G3, targeting left nucleus ventralis posterior thalami. Paracentesis was performed in G4. 24 h after MRI scan, all animals were killed for examining pathological alternation (at different distance from lead) via transmission electron microscopy. Our results suggest that the severity of tissue injury correlates with the distance to electrode instead of field strength of MRI. Up to now, the reason for the restriction of MRI indicated no significantly different pathological change.
Literatur
2.
Zurück zum Zitat Liu Y, Chen J, Shellock FG, Kainz W (2013) Computational and experimental studies of an orthopedic implant: MRI-related heating at 1.5-T/64-MHz and 3-T/128-MHz. J Magn Reson Imaging JMRI 37(2):491–497. doi:10.1002/jmri.23764 CrossRefPubMed Liu Y, Chen J, Shellock FG, Kainz W (2013) Computational and experimental studies of an orthopedic implant: MRI-related heating at 1.5-T/64-MHz and 3-T/128-MHz. J Magn Reson Imaging JMRI 37(2):491–497. doi:10.​1002/​jmri.​23764 CrossRefPubMed
3.
Zurück zum Zitat Muranaka H, Horiguchi T, Ueda Y, Tanki N (2011) Evaluation of RF heating due to various implants during MR procedures. Magn Reson Med Sci MRMS Off J Jpn Soc Magn Reson Med 10(1):11–19. doi:10.2463/mrms.10.11 Muranaka H, Horiguchi T, Ueda Y, Tanki N (2011) Evaluation of RF heating due to various implants during MR procedures. Magn Reson Med Sci MRMS Off J Jpn Soc Magn Reson Med 10(1):11–19. doi:10.​2463/​mrms.​10.​11
6.
8.
Zurück zum Zitat Ullman M, Vedam-Mai V, Krock N, Sudhyadhom A, Foote KD, Yachnis AT, Merritt S, Resnick AS, Zeilman P, Okun MS (2011) A pilot study of human brain tissue post-magnetic resonance imaging: information from the National Deep Brain Stimulation Brain Tissue Network (DBS-BTN). NeuroImage 54(Suppl 1):S233–S237. doi:10.1016/j.neuroimage.2010.09.014 CrossRefPubMed Ullman M, Vedam-Mai V, Krock N, Sudhyadhom A, Foote KD, Yachnis AT, Merritt S, Resnick AS, Zeilman P, Okun MS (2011) A pilot study of human brain tissue post-magnetic resonance imaging: information from the National Deep Brain Stimulation Brain Tissue Network (DBS-BTN). NeuroImage 54(Suppl 1):S233–S237. doi:10.​1016/​j.​neuroimage.​2010.​09.​014 CrossRefPubMed
9.
Zurück zum Zitat Gorny KR, Presti MF, Goerss SJ, Hwang SC, Jang DP, Kim I, Min HK, Shu Y, Favazza CP, Lee KH, Bernstein MA (2013) Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator. Magn Reson Imaging 31(5):783–788. doi:10.1016/j.mri.2012.11.005 CrossRefPubMed Gorny KR, Presti MF, Goerss SJ, Hwang SC, Jang DP, Kim I, Min HK, Shu Y, Favazza CP, Lee KH, Bernstein MA (2013) Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator. Magn Reson Imaging 31(5):783–788. doi:10.​1016/​j.​mri.​2012.​11.​005 CrossRefPubMed
Metadaten
Titel
Ultra-high magnetic resonance imaging (MRI): a potential examination for deep brain stimulation devices and the limitation study concerning MRI-related heating injury
verfasst von
Ying-Chuan Chen
Jun-Ju Li
Guan-Yu Zhu
Lin Shi
An-Chao Yang
Yin Jiang
Xin Zhang
Jian-Guo Zhang
Publikationsdatum
01.03.2017
Verlag
Springer Milan
Erschienen in
Neurological Sciences / Ausgabe 3/2017
Print ISSN: 1590-1874
Elektronische ISSN: 1590-3478
DOI
https://doi.org/10.1007/s10072-016-2777-5

Weitere Artikel der Ausgabe 3/2017

Neurological Sciences 3/2017 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Sozialer Aufstieg verringert Demenzgefahr

24.05.2024 Demenz Nachrichten

Ein hohes soziales Niveau ist mit die beste Versicherung gegen eine Demenz. Noch geringer ist das Demenzrisiko für Menschen, die sozial aufsteigen: Sie gewinnen fast zwei demenzfreie Lebensjahre. Umgekehrt steigt die Demenzgefahr beim sozialen Abstieg.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Was nützt die Kraniektomie bei schwerer tiefer Hirnblutung?

17.05.2024 Hirnblutung Nachrichten

Eine Studie zum Nutzen der druckentlastenden Kraniektomie nach schwerer tiefer supratentorieller Hirnblutung deutet einen Nutzen der Operation an. Für überlebende Patienten ist das dennoch nur eine bedingt gute Nachricht.

Thrombektomie auch bei großen Infarkten von Vorteil

16.05.2024 Ischämischer Schlaganfall Nachrichten

Auch ein sehr ausgedehnter ischämischer Schlaganfall scheint an sich kein Grund zu sein, von einer mechanischen Thrombektomie abzusehen. Dafür spricht die LASTE-Studie, an der Patienten und Patientinnen mit einem ASPECTS von maximal 5 beteiligt waren.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.