Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 4/2020

Open Access 05.09.2019 | Brief Communication

Using real-time location devices (RTLD) to quantify off-unit adult intensive care registrar workload: a 1-year tertiary NHS hospital prospective observational study

verfasst von: James Malycha, Daniel Murphy, Graham Barker, Guy Ludbrook, J. Duncan Young, Peter J. Watkinson

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2020

Abstract

UK national guidelines state deteriorating or at risk hospital ward patients should receive care from trained critical care outreach personnel. In most tertiary hospitals this involves a team led by an Intensive Care Unit (ICU) registrar. The ICU registrar must also review patients referred for possible ICU admission. These two responsibilities require work away from the ICU. To our knowledge the burden of this work has not been described, despite its importance in ICU workforce management and patient safety. A 12-month, prospective, observational study was carried out. The primary outcome measure was ICU registrar time spent on and off-unit. The study participants were senior and junior registrars on the rota of the 16 bed, Adult Intensive Care Unit at the John Radcliffe Hospital in Oxford. To measure their work patterns, this study used AeroScout ‘T2’ Real Time Location Device (RTLD) tags (Stanley Healthcare, Swindon). In our hospital, senior and junior ICU registrars spend roughly one-fifth of their time off-unit, half of which is spent in ED. This workload combines to leave the unit unattended at night up to 10% of the time. RTLDs provide a reliable, automated method for quantifying ICU registrar off-unit work patterns. This method may be adopted for quantifying other clinical staff work patterns in suitably equipped hospital environments.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
ICU
Intensive Care Unit
ED
Emergency Department
EAU
Emergency Assessment Unit
RRS
Rapid Response System
RTLD
Real Time Location Device
OUHNHSFT
Oxford University Hospitals National Health Service Foundation Trust
NHS
National Health Service

1 Introduction

Current guidelines stipulate that National Health Service (NHS) hospitals must have appropriate Intensive Care Unit (ICU) staffing to ensure safe on-unit and off-unit patient care [1]. The majority of ICU registrar work is generated on-unit through admitting, managing and discharging critically ill patients (a registrar is a junior doctor who has completed foundational training, usually 2 years, and is in training in a specialty area of medicine or surgery). However, the United Kingdom (UK) National Outreach Forum Operational Standards and Competencies for Critical Care Outreach Services state deteriorating hospital ward patients should receive care from trained critical care outreach personnel. In most NHS hospitals this involves a team led by an ICU registrar [2]. The ICU registrar must also review ward patients referred for possible ICU admission [3]. These two responsibilities require work away from the ICU. To our knowledge this work has not been quantified in the literature, despite its importance in ICU workforce management and patient safety. This study used an automated method to evaluate the work locations of ICU registrars within a tertiary NHS hospital over a 12-month period.

2 Methods

The 12-month, prospective, observational study was carried out in accordance with the Revised Standards for Quality Improvement Reporting Excellence (SQUIRE 2.0) guidelines [4]. The study ran from April 1st 2017 to March 31st 2018.

2.1 Intervention

Real-time Location Devices (RTLDs) are small portable devices that can communicate with wireless (wifi) data networks. This study used AeroScout ‘T2’ RTLDs, (Stanley Healthcare, Swindon). The RTLDs determine their position by triangulating the signals from wireless access points (WAPs) and pass this information to the AeroScout software. The location of each WAP is premapped into the AeroScout software, so the RTLD position within the hospital building can be determined. The RTLD location is updated every 5 min. RTLDs are usually used to determine the location of mobile assets (such as portable physiological monitors). In this study the RTLDs were attached to the “baton” pagers carried by the registrars which are handed on at the end of each shift.

2.2 Measures

The primary outcome measure was ICU registrar time spent on and off the ICU. The study participants were registrars on the senior and junior tiers of the rota for the 16 bed, Adult Intensive Care Unit of the John Radcliffe Hospital, which is part of the Oxford University Hospitals National Health Service Foundation Trust (OUHNHSFT).

2.3 Analysis

Data analysis was carried out using Python version 2.7 (Python Software Foundation, Wilmington, USA).

2.4 Ethical considerations

Informed consent was not required, but all registrars were made aware of the study. Data were collected automatically in real time and securely stored within the hospital’s Aeroscout system. Access to the data was granted to JM only.

2.5 Validation

The tags were tested during the study by placing them in predesignated locations and times and cross-referencing these with the location data.

3 Results

Figure 1 shows the results of binary (i.e. on-unit/off-unit) analysis carried out on ICU doctor location during each of the shifts per 24 h. During the day shift (0830–1800) the adult ICU was staffed by both the senior and junior registrars as well as between two and five additional doctors of varying seniority. During the evening shift (1800–2100) and the night shift (2100–0830) the ICU was staffed by only the senior and junior registrars. In the latter two shifts, the ICU was therefore left unattended if both registrars were called off-unit.
Off-unit location analysis showed that during the day shift (0800–1830), on average, the senior and junior registrars spent 7% of their time in the Emergency Department (ED)/Emergency Assessment Unit (EAU) and 8% in the general wards. During the evening shift (1830–2100), on average, both registrars spent 10% in the ED/EAU and 7% in the general wards. During the night shift (2100–0830), on average, both registrars spent 8% in the ED/AEU and 11% in the general wards. Variation in registrar off-unit work load between days of the week was minimal. Results are included in the Appendix (Fig. 3). A detailed description of the locations making up the category ‘general wards’ are included in the Appendix (Fig. 4a, b).

4 Discussion

4.1 Summary

The provision of intensive care in NHS hospitals increasingly involves off-unit registrar work, which is important but time consuming and expensive. We are the first to use RTLDs to quantify this activity. In our hospital, senior and junior ICU registrars spend roughly one-fifth of their time off-unit, half of which is spent in the ED. This workload combines to leave the unit unattended at night up to 10% of the time. This method and these data will help inform decisions about ICU off-unit workload and staffing and may in turn improve patient safety.

4.2 Interpretation

This study established the feasibility of this method to establish staff working locations (both ICU and non-ICU) which could be applied to other hospitals. RTLD tags are already widely used in the NHS to monitor the location of portable medical devices so adapting this method may prove cost effective and efficient in those cases. Generally, a detailed understanding of when, where and how long ICU registrars spend off-unit will assist in customising staffing in ICU and in areas where ICU expertise are required (e.g. the ED). Additionally, being aware of when and how often an ICU is without a registrar with airway expertise (as was the case for up to 10% of the night shift) is of clinical importance. Locally, this data informed staffing decisions.

5 Limitations

The temporal resolution (5 min) of this study was preset by the tracking devices and could not be modified. ‘Floor hopping’, where the RTLD communicates a WAP on the floor above or below is dependent on WAP layout and occurred roughly 1% of the time. This system requires Aeroscout or similar hardware and software to be installed within the hospital and collaboration with skilled hospital Information Technology technicians. These data give ICU registrar work locations and times but not work type. We made the assumption that ICU registrars were off-unit in response to work demand alone and this may have not always been the case. Likewise, we acknowledge individual doctors will have approached the same workload in different ways. The data was anonymised so individual doctor off-unit workload patterns were not evaluated and this may have introduced bias into the results.

6 Conclusions

RTLDs provide a reliable, automated method for quantifying ICU registrar off-unit work patterns. This method may be adopted for quantifying other clinical staff work patterns in suitably equipped hospital environments.

Acknowledgements

JM would like to acknowledge the University of Adelaide, Department of Acute Medicine, who are administering his PhD.

Compliance with ethical standards

Competing interests

The authors declare that they have no competing interests. PW is Chief Medical Officer for Sensyne Health and holds shares in the company.
Health Research Authority (South Central – Oxford C, Research Ethics Committee (REC), nrescommittee.southcentral-oxfordc@nhs.net) approval was sought but not required as the study was deemed a quality improvement project. All documents and data were stored securely and only accessible by study staff and authorised personnel. The study complied with the Data Protection Act.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Anhänge

Appendix

See Figs. 2, 3, and 4.
Literatur
1.
Zurück zum Zitat National Outreach Forum: Operational Standards and Competencies for Critical Care Outreach Services. 2012; p. 20. National Outreach Forum: Operational Standards and Competencies for Critical Care Outreach Services. 2012; p. 20.
2.
Zurück zum Zitat Faculty of Intensive Care Medicine, Intensive Care Society: Guidelines for the Provision of Intensive Care Services 2016 Edition 1.1. 2016; pp. 50–65. Faculty of Intensive Care Medicine, Intensive Care Society: Guidelines for the Provision of Intensive Care Services 2016 Edition 1.1. 2016; pp. 50–65.
3.
Zurück zum Zitat Nates JL, Nunnally M, Kleinpell R, et al. ICU admission, discharge, and triage guidelines: a framework to enhance clinical operations, development of institutional policies, and further research. Crit Care Med. 2016;44:1553.CrossRef Nates JL, Nunnally M, Kleinpell R, et al. ICU admission, discharge, and triage guidelines: a framework to enhance clinical operations, development of institutional policies, and further research. Crit Care Med. 2016;44:1553.CrossRef
4.
Zurück zum Zitat Davies L, Davidoff F, Goodman D, et al. SQUIRE 2.0 (Standards for QUality Improvement Reporting Excellence). Am J Med Qual. 2015;30:543–9.CrossRef Davies L, Davidoff F, Goodman D, et al. SQUIRE 2.0 (Standards for QUality Improvement Reporting Excellence). Am J Med Qual. 2015;30:543–9.CrossRef
Metadaten
Titel
Using real-time location devices (RTLD) to quantify off-unit adult intensive care registrar workload: a 1-year tertiary NHS hospital prospective observational study
verfasst von
James Malycha
Daniel Murphy
Graham Barker
Guy Ludbrook
J. Duncan Young
Peter J. Watkinson
Publikationsdatum
05.09.2019
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2020
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-019-00383-z

Weitere Artikel der Ausgabe 4/2020

Journal of Clinical Monitoring and Computing 4/2020 Zur Ausgabe

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.