A new approach to complicated and noisy physiological waveforms analysis: peripheral venous pressure waveform as an example

verfasst von: Hau-Tieng Wu, Aymen Alian, Kirk Shelley

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 3/2021

Einloggen, um Zugang zu erhalten

Abstract

We introduce a recently developed nonlinear-type time–frequency analysis tool, synchrosqueezing transform (SST), to quantify complicated and noisy physiological waveform that has time-varying amplitude and frequency. We apply it to analyze a peripheral venous pressure (PVP) signal recorded during a seven hours aortic valve replacement procedure. In addition to showing the captured dynamics, we also quantify how accurately we can estimate the instantaneous heart rate from the PVP signal.
Fußnoten
1
When we are concerned with the statistical properties, the stationarity is defined to have a zero mean and the covariance between any two time points only depends on the time difference. We do not pursue this kind of stationarity in this work.
 
2
The power spectrum is usually defined as the magnitude squared of the Fourier transform of a given signal. In this paper, to avoid the normalization issue, we call the magnitude of the Fourier transform of a given signal the power spectrum.
 
Literatur
1.
Zurück zum Zitat Wardhan R, Shelley K. Peripheral venous pressure waveform. Curr Opin Anaesthesiol. 2009;22:814–21.CrossRef Wardhan R, Shelley K. Peripheral venous pressure waveform. Curr Opin Anaesthesiol. 2009;22:814–21.CrossRef
2.
Zurück zum Zitat Charalambous C, et al. Comparison of peripheral and central venous pressures in critically Ill patients. Anaesth Intensive Care. 2003;31:34–9.CrossRef Charalambous C, et al. Comparison of peripheral and central venous pressures in critically Ill patients. Anaesth Intensive Care. 2003;31:34–9.CrossRef
3.
Zurück zum Zitat Weingarten T, Sprung J, Munis J. Peripheral venous pressure as a measure of venous compliance during pheochromocytoma resection. Anesth Analg. 2004;99:1035–7.CrossRef Weingarten T, Sprung J, Munis J. Peripheral venous pressure as a measure of venous compliance during pheochromocytoma resection. Anesth Analg. 2004;99:1035–7.CrossRef
4.
Zurück zum Zitat Kim S, et al. Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery. Br J Anaesth. 2011;106:305–11.CrossRef Kim S, et al. Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery. Br J Anaesth. 2011;106:305–11.CrossRef
5.
Zurück zum Zitat Sperry BW, et al. Peripheral venous pressure measurements in patients with acute decompensated heart failure (PVP-HF). Circulation. 2017;10(7):e001430. Sperry BW, et al. Peripheral venous pressure measurements in patients with acute decompensated heart failure (PVP-HF). Circulation. 2017;10(7):e001430.
6.
Zurück zum Zitat Sahin A, et al. Effect of catheter site on the agreement of peripheral and central venous pressure measurements in neurosurgical patients. J Clin Anesth. 2005;17:348–52.CrossRef Sahin A, et al. Effect of catheter site on the agreement of peripheral and central venous pressure measurements in neurosurgical patients. J Clin Anesth. 2005;17:348–52.CrossRef
7.
Zurück zum Zitat Anter A, Bondok R. Peripheral venous pressure is an alternative to central venous pressure in paediatric surgery patients. Acta Anaesthesiol Scand. 2004;48:1101–4.CrossRef Anter A, Bondok R. Peripheral venous pressure is an alternative to central venous pressure in paediatric surgery patients. Acta Anaesthesiol Scand. 2004;48:1101–4.CrossRef
8.
Zurück zum Zitat Bombardieri A, et al. Comparative utility of centrally versus peripherally transduced venous pressure monitoring in the perioperative period in spine surgery patients. J Clin Anesth. 2014;24:542–8.CrossRef Bombardieri A, et al. Comparative utility of centrally versus peripherally transduced venous pressure monitoring in the perioperative period in spine surgery patients. J Clin Anesth. 2014;24:542–8.CrossRef
9.
Zurück zum Zitat Amar D, et al. Correlation of peripheral venous pressure and central venous pressure in surgical patients. J Cardiothorac Vasc Anesth. 2001;15:40–3.CrossRef Amar D, et al. Correlation of peripheral venous pressure and central venous pressure in surgical patients. J Cardiothorac Vasc Anesth. 2001;15:40–3.CrossRef
10.
Zurück zum Zitat Amoozgar H, et al. Correlation between peripheral and central venous pressures in children with congenital heart disease. Pediatr Cardiol. 2008;29:281–4.CrossRef Amoozgar H, et al. Correlation between peripheral and central venous pressures in children with congenital heart disease. Pediatr Cardiol. 2008;29:281–4.CrossRef
11.
Zurück zum Zitat Milhoan K, et al. Upper extremity peripheral venous pressure measurements accurately reflect pulmonary artery pressures in patients with cavopulmonary or Fontan connections. Pediatr Cardiol. 2004;25:17–9.CrossRef Milhoan K, et al. Upper extremity peripheral venous pressure measurements accurately reflect pulmonary artery pressures in patients with cavopulmonary or Fontan connections. Pediatr Cardiol. 2004;25:17–9.CrossRef
12.
Zurück zum Zitat Baty L, Russo P, Tobias J. Measurement of central venous pressure from a peripheral intravenous catheter following cardiopulmonary bypass in infants and children with congenital heart disease. J Intensive Care Med. 2008;23:136–42.CrossRef Baty L, Russo P, Tobias J. Measurement of central venous pressure from a peripheral intravenous catheter following cardiopulmonary bypass in infants and children with congenital heart disease. J Intensive Care Med. 2008;23:136–42.CrossRef
13.
Zurück zum Zitat Hoftman N, et al. Peripheral venous pressure as a predictor of central venous pressure during orthotopic liver transplantation. J Clin Anesth. 2006;18:251–5.CrossRef Hoftman N, et al. Peripheral venous pressure as a predictor of central venous pressure during orthotopic liver transplantation. J Clin Anesth. 2006;18:251–5.CrossRef
14.
Zurück zum Zitat Hadimioglu N, et al. Correlation of peripheral venous pressure and central venous pressure in kidney recipients. Transplant Proc. 2006;38:440–2.CrossRef Hadimioglu N, et al. Correlation of peripheral venous pressure and central venous pressure in kidney recipients. Transplant Proc. 2006;38:440–2.CrossRef
15.
Zurück zum Zitat Choi S, et al. Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors? Liver Transpl. 2007;13:1414–21.CrossRef Choi S, et al. Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors? Liver Transpl. 2007;13:1414–21.CrossRef
16.
Zurück zum Zitat Daubechies I, Maes S. A nonlinear squeezing of the continuous wavelet transform based on auditory nerve models. In: Aldroubi A, Unser M, editors. Wavelets in Medicine and Biology. Boca Raton: CRC Press; 1996. p. 527–546. Daubechies I, Maes S. A nonlinear squeezing of the continuous wavelet transform based on auditory nerve models. In: Aldroubi A, Unser M, editors. Wavelets in Medicine and Biology. Boca Raton: CRC Press; 1996. p. 527–546.
17.
Zurück zum Zitat Chen Y-C, Cheng M-Y, Wu H-T. Nonparametric and adaptive modeling of dynamic seasonality and trend with heteroscedastic and dependent errors. JRSS-B. 2014;76(3):651–82.CrossRef Chen Y-C, Cheng M-Y, Wu H-T. Nonparametric and adaptive modeling of dynamic seasonality and trend with heteroscedastic and dependent errors. JRSS-B. 2014;76(3):651–82.CrossRef
18.
Zurück zum Zitat Daubechies I, Lu J, Wu H-T. Synchrosqueezed Wavelet Transforms: An empirical mode decomposition-like tool. Appl Comp Harmon Anal. 2011;30(1):243–61.CrossRef Daubechies I, Lu J, Wu H-T. Synchrosqueezed Wavelet Transforms: An empirical mode decomposition-like tool. Appl Comp Harmon Anal. 2011;30(1):243–61.CrossRef
19.
Zurück zum Zitat Flandrin P. Time-frequency/time-scale analysis. Wavelet analysis and its applications. Cambridge: Academic Press; 1998. Flandrin P. Time-frequency/time-scale analysis. Wavelet analysis and its applications. Cambridge: Academic Press; 1998.
20.
Zurück zum Zitat Task Force of the European Society of Cardiology the North American Society of Pacing Electrophysiology. Heart rate variability. standards of measurement, physiological interpretation, and clinical use. Circulation. 1996;93:1043–65.CrossRef Task Force of the European Society of Cardiology the North American Society of Pacing Electrophysiology. Heart rate variability. standards of measurement, physiological interpretation, and clinical use. Circulation. 1996;93:1043–65.CrossRef
21.
Zurück zum Zitat Shelley KH. Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate. Anesth Analg. 2007;105(6):S31–S3636.CrossRef Shelley KH. Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate. Anesth Analg. 2007;105(6):S31–S3636.CrossRef
22.
Zurück zum Zitat Nilsson L. Respiration signals from photoplethysmography. Anesth Analg. 2013;117(4):859–65.CrossRef Nilsson L. Respiration signals from photoplethysmography. Anesth Analg. 2013;117(4):859–65.CrossRef
23.
Zurück zum Zitat Alian AA, Shelley KH. Respiratory physiology and the impact of different modes of ventilation on the photoplethysmographic waveform. Sensors. 2012;12:2236–54.CrossRef Alian AA, Shelley KH. Respiratory physiology and the impact of different modes of ventilation on the photoplethysmographic waveform. Sensors. 2012;12:2236–54.CrossRef
24.
Zurück zum Zitat Lu S, et al. Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? J Clin Monit Comput. 2008;22(1):23–9.CrossRef Lu S, et al. Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? J Clin Monit Comput. 2008;22(1):23–9.CrossRef
25.
26.
Zurück zum Zitat Alian A, et al. Impact of central hypovolemia on peripheral venous pressure waveform parameters in healthy volunteers. Physiol Meas. 2014;35(7):1509–20.CrossRef Alian A, et al. Impact of central hypovolemia on peripheral venous pressure waveform parameters in healthy volunteers. Physiol Meas. 2014;35(7):1509–20.CrossRef
27.
Zurück zum Zitat Elgendi M. Detection of c, d, and e waves in the acceleration photoplethysmogram. Comput Methods Programs Biomed. 2014;117(2):125–36.CrossRef Elgendi M. Detection of c, d, and e waves in the acceleration photoplethysmogram. Comput Methods Programs Biomed. 2014;117(2):125–36.CrossRef
28.
Zurück zum Zitat Johnson A, et al. Multimodal heart beat detection using signal quality indices. Physiol Meas. 2015;36(8):1665–777.CrossRef Johnson A, et al. Multimodal heart beat detection using signal quality indices. Physiol Meas. 2015;36(8):1665–777.CrossRef
Metadaten
Titel
A new approach to complicated and noisy physiological waveforms analysis: peripheral venous pressure waveform as an example
verfasst von
Hau-Tieng Wu
Aymen Alian
Kirk Shelley
Publikationsdatum
11.06.2020
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 3/2021
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00524-9

Weitere Artikel der Ausgabe 3/2021

Journal of Clinical Monitoring and Computing 3/2021 Zur Ausgabe

Original Research

Understanding dysnatremia

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.