Skip to main content
Erschienen in: Abdominal Radiology 5/2018

19.02.2018

Abdominal aortic aneurysms: pre- and post-procedural imaging

verfasst von: Richard L. Hallett, Brant W. Ullery, Dominik Fleischmann

Erschienen in: Abdominal Radiology | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

Abdominal aortic aneurysm (AAA) is a relatively common, potentially life-threatening disorder. Rupture of AAA is potentially catastrophic with high mortality. Intervention for AAA is indicated when the aneurysm reaches 5.0–5.5 cm or more, when symptomatic, or when increasing in size > 10 mm/year. AAA can be accurately assessed by cross-sectional imaging including computed tomography angiography and magnetic resonance angiography. Current options for intervention in AAA patients include open surgery and endovascular aneurysm repair (EVAR), with EVAR becoming more prevalent over time. Cross-sectional imaging plays a crucial role in AAA surveillance, pre-procedural assessment, and post-EVAR management. This paper will discuss the current role of imaging in the assessment of AAA patients prior to intervention, in evaluation of procedural complications, and in long-term follow-up of EVAR patients.
Literatur
1.
Zurück zum Zitat Aggarwal S, Qamar A, Sharma V, Sharma A (2011) Abdominal aortic aneurysm: a comprehensive review. Exp Clin Cardiol 16:11–15PubMedPubMedCentral Aggarwal S, Qamar A, Sharma V, Sharma A (2011) Abdominal aortic aneurysm: a comprehensive review. Exp Clin Cardiol 16:11–15PubMedPubMedCentral
2.
Zurück zum Zitat Pearce WH, Zarins CK, Bacharach JM, American Heart Association Writing Group 6 (2008) Atherosclerotic peripheral vascular disease symposium II: controversies in abdominal aortic aneurysm repair. Circulation 118:2860–2863PubMedCrossRef Pearce WH, Zarins CK, Bacharach JM, American Heart Association Writing Group 6 (2008) Atherosclerotic peripheral vascular disease symposium II: controversies in abdominal aortic aneurysm repair. Circulation 118:2860–2863PubMedCrossRef
3.
Zurück zum Zitat Lederle FA, Johnson GR, Wilson SE, et al. (2002) Rupture rate of large abdominal aortic aneurysms in patients refusing or unfit for elective repair. JAMA 287:2968–2972PubMedCrossRef Lederle FA, Johnson GR, Wilson SE, et al. (2002) Rupture rate of large abdominal aortic aneurysms in patients refusing or unfit for elective repair. JAMA 287:2968–2972PubMedCrossRef
4.
Zurück zum Zitat Assar AN, Zarins CK (2009) Ruptured abdominal aortic aneurysm: a surgical emergency with many clinical presentations. Postgrad Med J 85:268–273PubMedCrossRef Assar AN, Zarins CK (2009) Ruptured abdominal aortic aneurysm: a surgical emergency with many clinical presentations. Postgrad Med J 85:268–273PubMedCrossRef
5.
Zurück zum Zitat Walker TG, Kalva SP, Yeddula K, et al. (2010) Clinical practice guidelines for endovascular abdominal aortic aneurysm repair: written by the Standards of Practice Committee for the Society of Interventional Radiology and endorsed by the Cardiovascular and Interventional Radiological Society of Europe and the Canadian Interventional Radiology Association. JVIR 21:1632–1655PubMedCrossRef Walker TG, Kalva SP, Yeddula K, et al. (2010) Clinical practice guidelines for endovascular abdominal aortic aneurysm repair: written by the Standards of Practice Committee for the Society of Interventional Radiology and endorsed by the Cardiovascular and Interventional Radiological Society of Europe and the Canadian Interventional Radiology Association. JVIR 21:1632–1655PubMedCrossRef
6.
Zurück zum Zitat Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMedCrossRef Parodi JC, Palmaz JC, Barone HD (1991) Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 5:491–499PubMedCrossRef
7.
Zurück zum Zitat Ng TT, Mirocha J, Magner D, Gewertz BL (2010) Variations in the utilization of endovascular aneurysm repair reflect population risk factors and disease prevalence. J Vasc Surg 51:801.e1–809.e1CrossRef Ng TT, Mirocha J, Magner D, Gewertz BL (2010) Variations in the utilization of endovascular aneurysm repair reflect population risk factors and disease prevalence. J Vasc Surg 51:801.e1–809.e1CrossRef
8.
Zurück zum Zitat Schermerhorn ML, O’Malley AJ, Jhaveri A, et al. (2008) Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population. N Engl J Med Mass Med Soc 358:464–474CrossRef Schermerhorn ML, O’Malley AJ, Jhaveri A, et al. (2008) Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population. N Engl J Med Mass Med Soc 358:464–474CrossRef
10.
Zurück zum Zitat Powell JT, Sweeting MJ, Ulug P, et al. (2017) Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years. Br J Surg 104:166–178PubMedPubMedCentralCrossRef Powell JT, Sweeting MJ, Ulug P, et al. (2017) Meta-analysis of individual-patient data from EVAR-1, DREAM, OVER and ACE trials comparing outcomes of endovascular or open repair for abdominal aortic aneurysm over 5 years. Br J Surg 104:166–178PubMedPubMedCentralCrossRef
11.
Zurück zum Zitat Prinssen M, Buskens E, de Jong SE, et al. (2007) Cost-effectiveness of conventional and endovascular repair of abdominal aortic aneurysms: results of a randomized trial. J Vasc Surg 46:883–890PubMedCrossRef Prinssen M, Buskens E, de Jong SE, et al. (2007) Cost-effectiveness of conventional and endovascular repair of abdominal aortic aneurysms: results of a randomized trial. J Vasc Surg 46:883–890PubMedCrossRef
12.
Zurück zum Zitat United Kingdom EVAR Trial Investigators, Greenhalgh RM, Brown LC, et al. (2010) Endovascular versus open repair of abdominal aortic aneurysm. N Engl J Med 362:1863–1871CrossRef United Kingdom EVAR Trial Investigators, Greenhalgh RM, Brown LC, et al. (2010) Endovascular versus open repair of abdominal aortic aneurysm. N Engl J Med 362:1863–1871CrossRef
13.
Zurück zum Zitat White GH, Yu W, May J (1996) Endoleak: a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft. J Endovasc Surg 3:124–125PubMedCrossRef White GH, Yu W, May J (1996) Endoleak: a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft. J Endovasc Surg 3:124–125PubMedCrossRef
14.
Zurück zum Zitat Fontaine V, Jacob M-P, Houard X, et al. (2002) Involvement of the mural thrombus as a site of protease release and activation in human aortic aneurysms. Am J Pathol 161:1701–1710PubMedPubMedCentralCrossRef Fontaine V, Jacob M-P, Houard X, et al. (2002) Involvement of the mural thrombus as a site of protease release and activation in human aortic aneurysms. Am J Pathol 161:1701–1710PubMedPubMedCentralCrossRef
15.
Zurück zum Zitat Di Martino ES, Vorp DA (2003) Effect of variation in intraluminal thrombus constitutive properties on abdominal aortic aneurysm wall stress. Ann Biomed Eng 31:804–809PubMedCrossRef Di Martino ES, Vorp DA (2003) Effect of variation in intraluminal thrombus constitutive properties on abdominal aortic aneurysm wall stress. Ann Biomed Eng 31:804–809PubMedCrossRef
16.
Zurück zum Zitat Picel AC, Kansal N (2014) Essentials of endovascular abdominal aortic aneurysm repair imaging: postprocedure surveillance and complications. Am J Roentgenol 203:W358–W372CrossRef Picel AC, Kansal N (2014) Essentials of endovascular abdominal aortic aneurysm repair imaging: postprocedure surveillance and complications. Am J Roentgenol 203:W358–W372CrossRef
17.
Zurück zum Zitat Brown LC, Greenhalgh RM, Powell JT, Thompson SG (2010) EVAR trial participants. Use of baseline factors to predict complications and reinterventions after endovascular repair of abdominal aortic aneurysm. Br J Surg 97:1207–1217PubMedCrossRef Brown LC, Greenhalgh RM, Powell JT, Thompson SG (2010) EVAR trial participants. Use of baseline factors to predict complications and reinterventions after endovascular repair of abdominal aortic aneurysm. Br J Surg 97:1207–1217PubMedCrossRef
18.
Zurück zum Zitat Iezzi R, Cotroneo AR (2006) Endovascular repair of abdominal aortic aneurysms: CTA evaluation of contraindications. Abdom Imaging 31:722–731PubMedCrossRef Iezzi R, Cotroneo AR (2006) Endovascular repair of abdominal aortic aneurysms: CTA evaluation of contraindications. Abdom Imaging 31:722–731PubMedCrossRef
19.
Zurück zum Zitat Truijers M, Resch T, Van Den Berg JC, Blankensteijn JD, Lönn L (2009) Endovascular aneurysm repair: state-of-art imaging techniques for preoperative planning and surveillance. J Cardiovasc Surg 50:423–438 Truijers M, Resch T, Van Den Berg JC, Blankensteijn JD, Lönn L (2009) Endovascular aneurysm repair: state-of-art imaging techniques for preoperative planning and surveillance. J Cardiovasc Surg 50:423–438
20.
Zurück zum Zitat van Keulen JW, van Prehn J, Prokop M, Moll FL, van Herwaarden JA (2009) Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair. J Endovasc Ther 16:506–513PubMedCrossRef van Keulen JW, van Prehn J, Prokop M, Moll FL, van Herwaarden JA (2009) Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair. J Endovasc Ther 16:506–513PubMedCrossRef
21.
Zurück zum Zitat Prinssen M, Verhoeven ELG, Verhagen HJM, Blankensteijn JD (2003) Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: a blinded comparison. Eur J Vasc Endovasc Surg 26:184–187PubMedCrossRef Prinssen M, Verhoeven ELG, Verhagen HJM, Blankensteijn JD (2003) Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: a blinded comparison. Eur J Vasc Endovasc Surg 26:184–187PubMedCrossRef
22.
Zurück zum Zitat Karmacharya J, Parmer SS, Antezana JN, et al. (2006) Outcomes of accessory renal artery occlusion during endovascular aneurysm repair. J Vasc Surg 43:8–13PubMedCrossRef Karmacharya J, Parmer SS, Antezana JN, et al. (2006) Outcomes of accessory renal artery occlusion during endovascular aneurysm repair. J Vasc Surg 43:8–13PubMedCrossRef
23.
Zurück zum Zitat Picel AC, Kansal N (2014) Essentials of endovascular abdominal aortic aneurysm repair imaging: preprocedural assessment. Am J Roentgenol 203:W347–W357CrossRef Picel AC, Kansal N (2014) Essentials of endovascular abdominal aortic aneurysm repair imaging: preprocedural assessment. Am J Roentgenol 203:W347–W357CrossRef
24.
Zurück zum Zitat Bastos Gonçalves F, Verhagen HJM, Chinsakchai K, et al. (2012) The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair. J Vasc Surg 56:36–44PubMedCrossRef Bastos Gonçalves F, Verhagen HJM, Chinsakchai K, et al. (2012) The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair. J Vasc Surg 56:36–44PubMedCrossRef
25.
Zurück zum Zitat Ishibashi H, Ishiguchi T, Ohta T, et al. (2012) Remodeling of proximal neck angulation after endovascular aneurysm repair. J Vasc Surg 56:1201–1205PubMedCrossRef Ishibashi H, Ishiguchi T, Ohta T, et al. (2012) Remodeling of proximal neck angulation after endovascular aneurysm repair. J Vasc Surg 56:1201–1205PubMedCrossRef
26.
Zurück zum Zitat Robbins M, Kritpracha B, Beebe HG, et al. (2005) Suprarenal endograft fixation avoids adverse outcomes associated with aortic neck angulation. Ann Vasc Surg 19:172–177PubMedCrossRef Robbins M, Kritpracha B, Beebe HG, et al. (2005) Suprarenal endograft fixation avoids adverse outcomes associated with aortic neck angulation. Ann Vasc Surg 19:172–177PubMedCrossRef
27.
Zurück zum Zitat Donas KP, Torsello G, Bisdas T, et al. (2012) Early outcomes for fenestrated and chimney endografts in the treatment of pararenal aortic pathologies are not significantly different: a systematic review with pooled data analysis. J Endovasc Ther 19:723–728PubMedCrossRef Donas KP, Torsello G, Bisdas T, et al. (2012) Early outcomes for fenestrated and chimney endografts in the treatment of pararenal aortic pathologies are not significantly different: a systematic review with pooled data analysis. J Endovasc Ther 19:723–728PubMedCrossRef
28.
Zurück zum Zitat Lindblad B, Bin Jabr A, Holst J, Malina M (2015) Chimney grafts in aortic stent grafting: hazardous or useful technique? Systematic review of current data. Eur J Vasc Endovasc Surg 50:722–731PubMedCrossRef Lindblad B, Bin Jabr A, Holst J, Malina M (2015) Chimney grafts in aortic stent grafting: hazardous or useful technique? Systematic review of current data. Eur J Vasc Endovasc Surg 50:722–731PubMedCrossRef
29.
Zurück zum Zitat Linsen MAM, Jongkind V, Nio D, Hoksbergen AWJ, Wisselink W (2012) Pararenal aortic aneurysm repair using fenestrated endografts. J Vasc Surg 56:238–246PubMedCrossRef Linsen MAM, Jongkind V, Nio D, Hoksbergen AWJ, Wisselink W (2012) Pararenal aortic aneurysm repair using fenestrated endografts. J Vasc Surg 56:238–246PubMedCrossRef
30.
Zurück zum Zitat Agag G, Salomon du Mont L, Leclerc B, Behr J, Rinckenbach S (2017) Is suprarenal fixation of aortic stent grafts really without consequence on the renal function? Ann Vasc Surg 39:90–98PubMedCrossRef Agag G, Salomon du Mont L, Leclerc B, Behr J, Rinckenbach S (2017) Is suprarenal fixation of aortic stent grafts really without consequence on the renal function? Ann Vasc Surg 39:90–98PubMedCrossRef
31.
Zurück zum Zitat Gawenda M, Brunkwall J (2008) Renal response to open and endovascular repair of abdominal aortic aneurysm: a prospective study. Ann Vasc Surg 22:1–4PubMedCrossRef Gawenda M, Brunkwall J (2008) Renal response to open and endovascular repair of abdominal aortic aneurysm: a prospective study. Ann Vasc Surg 22:1–4PubMedCrossRef
32.
Zurück zum Zitat Saratzis A, Sarafidis P, Melas N, Khaira H (2014) Comparison of the impact of open and endovascular abdominal aortic aneurysm repair on renal function. J Vasc Surg 60:597–603PubMedCrossRef Saratzis A, Sarafidis P, Melas N, Khaira H (2014) Comparison of the impact of open and endovascular abdominal aortic aneurysm repair on renal function. J Vasc Surg 60:597–603PubMedCrossRef
33.
Zurück zum Zitat Walsh SR, Boyle JR, Lynch AG, et al. (2008) Suprarenal endograft fixation and medium-term renal function: systematic review and meta-analysis. J Vasc Surg 47:1364–1370PubMedCrossRef Walsh SR, Boyle JR, Lynch AG, et al. (2008) Suprarenal endograft fixation and medium-term renal function: systematic review and meta-analysis. J Vasc Surg 47:1364–1370PubMedCrossRef
34.
Zurück zum Zitat Alsac J-M, Zarins CK, Heikkinen MA, et al. (2005) The impact of aortic endografts on renal function. J Vasc Surg 41:926–930PubMedCrossRef Alsac J-M, Zarins CK, Heikkinen MA, et al. (2005) The impact of aortic endografts on renal function. J Vasc Surg 41:926–930PubMedCrossRef
35.
Zurück zum Zitat Lau LL, Hakaim AG, Oldenburg WA, et al. (2003) Effect of suprarenal versus infrarenal aortic endograft fixation on renal function and renal artery patency: a comparative study with intermediate follow-up. J Vasc Surg 37:1162–1168PubMedCrossRef Lau LL, Hakaim AG, Oldenburg WA, et al. (2003) Effect of suprarenal versus infrarenal aortic endograft fixation on renal function and renal artery patency: a comparative study with intermediate follow-up. J Vasc Surg 37:1162–1168PubMedCrossRef
36.
Zurück zum Zitat Parmer SS, Carpenter JP (2006) Endologix Investigators. Endovascular aneurysm repair with suprarenal vs infrarenal fixation: a study of renal effects. J Vasc Surg 43:19–25PubMedCrossRef Parmer SS, Carpenter JP (2006) Endologix Investigators. Endovascular aneurysm repair with suprarenal vs infrarenal fixation: a study of renal effects. J Vasc Surg 43:19–25PubMedCrossRef
37.
Zurück zum Zitat Cayne NS, Rhee SJ, Veith FJ, et al. (2003) Does transrenal fixation of aortic endografts impair renal function? J Vasc Surg 38:639–644PubMedCrossRef Cayne NS, Rhee SJ, Veith FJ, et al. (2003) Does transrenal fixation of aortic endografts impair renal function? J Vasc Surg 38:639–644PubMedCrossRef
38.
Zurück zum Zitat Chaikof EL, Fillinger MF, Matsumura JS, et al. (2002) Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg 35:1061–1066PubMedCrossRef Chaikof EL, Fillinger MF, Matsumura JS, et al. (2002) Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg 35:1061–1066PubMedCrossRef
39.
Zurück zum Zitat Choi HR, Park KH, Lee JH (2016) Risk factor analysis for buttock claudication after internal iliac artery embolization with endovascular aortic aneurysm repair. Vasc Specialist Int 32:44–50PubMedPubMedCentralCrossRef Choi HR, Park KH, Lee JH (2016) Risk factor analysis for buttock claudication after internal iliac artery embolization with endovascular aortic aneurysm repair. Vasc Specialist Int 32:44–50PubMedPubMedCentralCrossRef
40.
Zurück zum Zitat Chun J-Y, Mailli L, Abbasi MA, et al. (2014) Embolization of the internal iliac artery before EVAR: is it effective? Is it safe? Which technique should be used? Cardiovasc Interv Radiol 37:329–336CrossRef Chun J-Y, Mailli L, Abbasi MA, et al. (2014) Embolization of the internal iliac artery before EVAR: is it effective? Is it safe? Which technique should be used? Cardiovasc Interv Radiol 37:329–336CrossRef
41.
Zurück zum Zitat Naughton PA, Park MS, Kheirelseid EAH, et al. (2012) A comparative study of the bell-bottom technique vs hypogastric exclusion for the treatment of aneurysmal extension to the iliac bifurcation. J Vasc Surg 55:956–962PubMedPubMedCentralCrossRef Naughton PA, Park MS, Kheirelseid EAH, et al. (2012) A comparative study of the bell-bottom technique vs hypogastric exclusion for the treatment of aneurysmal extension to the iliac bifurcation. J Vasc Surg 55:956–962PubMedPubMedCentralCrossRef
42.
Zurück zum Zitat Ferreira M, Monteiro M, Lanziotti L (2010) Technical aspects and midterm patency of iliac branched devices. J Vasc Surg 51:545–550 (Discussion 550)PubMedCrossRef Ferreira M, Monteiro M, Lanziotti L (2010) Technical aspects and midterm patency of iliac branched devices. J Vasc Surg 51:545–550 (Discussion 550)PubMedCrossRef
43.
Zurück zum Zitat Manunga JM, Gloviczki P, Oderich GS, et al. (2013) Femoral artery calcification as a determinant of success for percutaneous access for endovascular abdominal aortic aneurysm repair. J Vasc Surg 58:1208–1212PubMedCrossRef Manunga JM, Gloviczki P, Oderich GS, et al. (2013) Femoral artery calcification as a determinant of success for percutaneous access for endovascular abdominal aortic aneurysm repair. J Vasc Surg 58:1208–1212PubMedCrossRef
44.
Zurück zum Zitat Gupta V, Feng K, Cheruvu P, et al. (2014) High femoral artery bifurcation predicts contralateral high bifurcation: implications for complex percutaneous cardiovascular procedures requiring large caliber and/or dual access. J Invasive Cardiol 26:409–412PubMed Gupta V, Feng K, Cheruvu P, et al. (2014) High femoral artery bifurcation predicts contralateral high bifurcation: implications for complex percutaneous cardiovascular procedures requiring large caliber and/or dual access. J Invasive Cardiol 26:409–412PubMed
45.
Zurück zum Zitat Early H, Atkins M (2012) Technical tips for managing difficult iliac access. Semin Vasc Surg 25:138–143PubMedCrossRef Early H, Atkins M (2012) Technical tips for managing difficult iliac access. Semin Vasc Surg 25:138–143PubMedCrossRef
46.
Zurück zum Zitat Maldonado TS, Rockman CB, Riles E, et al. (2004) Ischemic complications after endovascular abdominal aortic aneurysm repair. J Vasc Surg 40:703–710 (Discussion 709)PubMedCrossRef Maldonado TS, Rockman CB, Riles E, et al. (2004) Ischemic complications after endovascular abdominal aortic aneurysm repair. J Vasc Surg 40:703–710 (Discussion 709)PubMedCrossRef
47.
Zurück zum Zitat Hodgson R, McWilliams RG, Simpson A, et al. (2003) Migration versus apparent migration: importance of errors due to positioning variation in plain radiographic follow-up of aortic stent-grafts. J Endovasc Ther 10:902–910PubMedCrossRef Hodgson R, McWilliams RG, Simpson A, et al. (2003) Migration versus apparent migration: importance of errors due to positioning variation in plain radiographic follow-up of aortic stent-grafts. J Endovasc Ther 10:902–910PubMedCrossRef
48.
Zurück zum Zitat Fearn S, Lawrence-Brown MMD, Semmens JB, Hartley D (2003) Follow-up after endovascular aortic aneurysm repair: the plain radiograph has an essential role in surveillance. J Endovasc Ther 10:894–901PubMedCrossRef Fearn S, Lawrence-Brown MMD, Semmens JB, Hartley D (2003) Follow-up after endovascular aortic aneurysm repair: the plain radiograph has an essential role in surveillance. J Endovasc Ther 10:894–901PubMedCrossRef
49.
Zurück zum Zitat Harrison GJ, Oshin OA, Vallabhaneni SR, et al. (2011) Surveillance after EVAR based on duplex ultrasound and abdominal radiography. Eur J Vasc Endovasc Surg 42:187–192PubMedCrossRef Harrison GJ, Oshin OA, Vallabhaneni SR, et al. (2011) Surveillance after EVAR based on duplex ultrasound and abdominal radiography. Eur J Vasc Endovasc Surg 42:187–192PubMedCrossRef
50.
Zurück zum Zitat Kranokpiraksa P, Kaufman JA (2008) Follow-up of endovascular aneurysm repair: plain radiography, ultrasound, CT/CT angiography, MR imaging/MR angiography, or what? JVIR 19:S27–S36PubMedCrossRef Kranokpiraksa P, Kaufman JA (2008) Follow-up of endovascular aneurysm repair: plain radiography, ultrasound, CT/CT angiography, MR imaging/MR angiography, or what? JVIR 19:S27–S36PubMedCrossRef
52.
Zurück zum Zitat Wolf YG, Johnson BL, Hill BB, et al. (2000) Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg 32:1142–1148PubMedCrossRef Wolf YG, Johnson BL, Hill BB, et al. (2000) Duplex ultrasound scanning versus computed tomographic angiography for postoperative evaluation of endovascular abdominal aortic aneurysm repair. J Vasc Surg 32:1142–1148PubMedCrossRef
53.
Zurück zum Zitat Sprouse LR, Meier GH, Parent FN, et al. (2004) Is ultrasound more accurate than axial computed tomography for determination of maximal abdominal aortic aneurysm diameter? Eur J Vasc Endovasc Surg 28:28–35PubMedCrossRef Sprouse LR, Meier GH, Parent FN, et al. (2004) Is ultrasound more accurate than axial computed tomography for determination of maximal abdominal aortic aneurysm diameter? Eur J Vasc Endovasc Surg 28:28–35PubMedCrossRef
54.
Zurück zum Zitat Beeman BR, Doctor LM, Doerr K, et al. (2009) Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: a cost analysis study and prospective comparison with computed tomography scan. J Vasc Surg 50:1019–1024PubMedCrossRef Beeman BR, Doctor LM, Doerr K, et al. (2009) Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: a cost analysis study and prospective comparison with computed tomography scan. J Vasc Surg 50:1019–1024PubMedCrossRef
55.
Zurück zum Zitat Raman KG, Missig-Carroll N, Richardson T, Muluk SC, Makaroun MS (2003) Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef Raman KG, Missig-Carroll N, Richardson T, Muluk SC, Makaroun MS (2003) Color-flow duplex ultrasound scan versus computed tomographic scan in the surveillance of endovascular aneurysm repair. J Vasc Surg 38:645–651PubMedCrossRef
56.
Zurück zum Zitat Sato DT, Goff CD, Gregory RT, et al. (1998) Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef Sato DT, Goff CD, Gregory RT, et al. (1998) Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound scan versus computed tomography scan. J Vasc Surg 28:657–663PubMedCrossRef
57.
Zurück zum Zitat Arko FR, Filis KA, Siedel SA, et al. (2003) Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair. J Vasc Surg 37:8–15PubMedCrossRef Arko FR, Filis KA, Siedel SA, et al. (2003) Intrasac flow velocities predict sealing of type II endoleaks after endovascular abdominal aortic aneurysm repair. J Vasc Surg 37:8–15PubMedCrossRef
58.
Zurück zum Zitat Nyheim T, Staxrud LE, Rosen L, et al. (2013) Review of postoperative CT and ultrasound for endovascular aneurysm repair using Talent stent graft: can we simplify the surveillance protocol and reduce the number of CT scans? Acta Radiol 54:54–58PubMedCrossRef Nyheim T, Staxrud LE, Rosen L, et al. (2013) Review of postoperative CT and ultrasound for endovascular aneurysm repair using Talent stent graft: can we simplify the surveillance protocol and reduce the number of CT scans? Acta Radiol 54:54–58PubMedCrossRef
59.
Zurück zum Zitat Sun Z (2006) Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. JVIR 17:759–764PubMedCrossRef Sun Z (2006) Diagnostic value of color duplex ultrasonography in the follow-up of endovascular repair of abdominal aortic aneurysm. JVIR 17:759–764PubMedCrossRef
60.
Zurück zum Zitat Cantisani V, Grazhdani H, Clevert D-A, et al. (2015) EVAR: benefits of CEUS for monitoring stent-graft status. Eur J Radiol 84:1658–1665PubMedCrossRef Cantisani V, Grazhdani H, Clevert D-A, et al. (2015) EVAR: benefits of CEUS for monitoring stent-graft status. Eur J Radiol 84:1658–1665PubMedCrossRef
61.
Zurück zum Zitat Napoli V, Bargellini I, Sardella SG, et al. (2004) Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMedCrossRef Napoli V, Bargellini I, Sardella SG, et al. (2004) Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair. Radiology 233:217–225PubMedCrossRef
62.
Zurück zum Zitat Ten Bosch JA, Rouwet EV, Peters CTH, et al. (2010) Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair. JVIR 21:638–643PubMedCrossRef Ten Bosch JA, Rouwet EV, Peters CTH, et al. (2010) Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair. JVIR 21:638–643PubMedCrossRef
63.
Zurück zum Zitat Ashoke R, Brown LC, Rodway A, et al. (2005) Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review. J Endovasc Ther 12:297–305PubMedCrossRef Ashoke R, Brown LC, Rodway A, et al. (2005) Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review. J Endovasc Ther 12:297–305PubMedCrossRef
64.
Zurück zum Zitat Roos JE, Hellinger JC, Hallet R, et al. (2005) Detection of endograft fractures with multidetector row computed tomography. J Vasc Surg 42:1002–1006PubMedCrossRef Roos JE, Hellinger JC, Hallet R, et al. (2005) Detection of endograft fractures with multidetector row computed tomography. J Vasc Surg 42:1002–1006PubMedCrossRef
65.
Zurück zum Zitat Tam MDBS, Laycock SD, Brown JRI, Jakeways M (2013) 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy. J Endovasc Ther 20:863–867PubMedCrossRef Tam MDBS, Laycock SD, Brown JRI, Jakeways M (2013) 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy. J Endovasc Ther 20:863–867PubMedCrossRef
66.
Zurück zum Zitat Tam MD, Latham T, Brown JRI, Jakeways M (2014) Use of a 3D printed hollow aortic model to assist EVAR planning in a case with complex neck anatomy: potential of 3D printing to improve patient outcome. J Endovasc Ther 21:760–762PubMedCrossRef Tam MD, Latham T, Brown JRI, Jakeways M (2014) Use of a 3D printed hollow aortic model to assist EVAR planning in a case with complex neck anatomy: potential of 3D printing to improve patient outcome. J Endovasc Ther 21:760–762PubMedCrossRef
67.
Zurück zum Zitat Armerding MD, Rubin GD, Beaulieu CF, et al. (2000) Aortic aneurysmal disease: assessment of stent-graft treatment-CT versus conventional angiography. Radiology 215:138–146PubMedCrossRef Armerding MD, Rubin GD, Beaulieu CF, et al. (2000) Aortic aneurysmal disease: assessment of stent-graft treatment-CT versus conventional angiography. Radiology 215:138–146PubMedCrossRef
68.
Zurück zum Zitat Bobadilla JL, Suwanabol PA, Reeder SB, et al. (2013) Clinical implications of non-contrast-enhanced computed tomography for follow-up after endovascular abdominal aortic aneurysm repair. Ann Vasc Surg 27:1042–1048PubMedCrossRef Bobadilla JL, Suwanabol PA, Reeder SB, et al. (2013) Clinical implications of non-contrast-enhanced computed tomography for follow-up after endovascular abdominal aortic aneurysm repair. Ann Vasc Surg 27:1042–1048PubMedCrossRef
69.
Zurück zum Zitat Macari M, Chandarana H, Schmidt B, et al. (2006) Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 241:908–914PubMedCrossRef Macari M, Chandarana H, Schmidt B, et al. (2006) Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? Radiology 241:908–914PubMedCrossRef
70.
Zurück zum Zitat Hansen NJ, Kaza RK, Maturen KE, Liu PS, Platt JF (2014) Evaluation of low-dose CT angiography with model-based iterative reconstruction after endovascular aneurysm repair of a thoracic or abdominal aortic aneurysm. Am J Roentgenol 202:648–655CrossRef Hansen NJ, Kaza RK, Maturen KE, Liu PS, Platt JF (2014) Evaluation of low-dose CT angiography with model-based iterative reconstruction after endovascular aneurysm repair of a thoracic or abdominal aortic aneurysm. Am J Roentgenol 202:648–655CrossRef
71.
Zurück zum Zitat Flors L, Leiva-Salinas C, Norton PT, Patrie JT, Hagspiel KD (2013) Endoleak detection after endovascular repair of thoracic aortic aneurysm using dual-source dual-energy CT: suitable scanning protocols and potential radiation dose reduction. Am J Roentgenol 200:451–460CrossRef Flors L, Leiva-Salinas C, Norton PT, Patrie JT, Hagspiel KD (2013) Endoleak detection after endovascular repair of thoracic aortic aneurysm using dual-source dual-energy CT: suitable scanning protocols and potential radiation dose reduction. Am J Roentgenol 200:451–460CrossRef
72.
Zurück zum Zitat Szucs-Farkas Z, Semadeni M, Bensler S, et al. (2009) Endoleak detection with CT angiography in an abdominal aortic aneurysm phantom: effect of tube energy, simulated patient size, and physical properties of endoleaks. Radiology 251:590–598PubMedCrossRef Szucs-Farkas Z, Semadeni M, Bensler S, et al. (2009) Endoleak detection with CT angiography in an abdominal aortic aneurysm phantom: effect of tube energy, simulated patient size, and physical properties of endoleaks. Radiology 251:590–598PubMedCrossRef
73.
Zurück zum Zitat Schindera ST, Graca P, Patak MA, et al. (2009) Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose. Investig Radiol 44:650–655CrossRef Schindera ST, Graca P, Patak MA, et al. (2009) Thoracoabdominal-aortoiliac multidetector-row CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose. Investig Radiol 44:650–655CrossRef
74.
Zurück zum Zitat Schoepf UJ, Meinel FG (eds) (2016) Multidetector-row CT of the Thorax, 2nd edn. Cham: Springer, pp 37–57 Schoepf UJ, Meinel FG (eds) (2016) Multidetector-row CT of the Thorax, 2nd edn. Cham: Springer, pp 37–57
75.
Zurück zum Zitat Ayuso JR, de Caralt TM, Pages M, et al. (2004) MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses. J Magn Reson Imaging 20:803–810PubMedCrossRef Ayuso JR, de Caralt TM, Pages M, et al. (2004) MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses. J Magn Reson Imaging 20:803–810PubMedCrossRef
76.
Zurück zum Zitat Pandey N, Litt H (2015) Surveillance imaging following endovascular aneurysm repair. Semin Interv Radiol 32:239–248CrossRef Pandey N, Litt H (2015) Surveillance imaging following endovascular aneurysm repair. Semin Interv Radiol 32:239–248CrossRef
77.
Zurück zum Zitat Lookstein RA, Goldman J, Pukin L, Marin ML (2004) Time-resolved magnetic resonance angiography as a noninvasive method to characterize endoleaks: initial results compared with conventional angiography. J Vasc Surg 39:27–33PubMedCrossRef Lookstein RA, Goldman J, Pukin L, Marin ML (2004) Time-resolved magnetic resonance angiography as a noninvasive method to characterize endoleaks: initial results compared with conventional angiography. J Vasc Surg 39:27–33PubMedCrossRef
78.
Zurück zum Zitat Hope TA, Zarins CK, Herfkens RJ (2009) Initial experience characterizing a type I endoleak from velocity profiles using time-resolved three-dimensional phase-contrast MRI. J Vasc Surg 49:1580–1584PubMedCrossRef Hope TA, Zarins CK, Herfkens RJ (2009) Initial experience characterizing a type I endoleak from velocity profiles using time-resolved three-dimensional phase-contrast MRI. J Vasc Surg 49:1580–1584PubMedCrossRef
79.
Zurück zum Zitat Sakata M, Takehara Y, Katahashi K, et al. (2016) Hemodynamic analysis of endoleaks after endovascular abdominal aortic aneurysm repair by using 4-dimensional flow-sensitive magnetic resonance imaging. Circ J 80:1715–1725PubMedCrossRef Sakata M, Takehara Y, Katahashi K, et al. (2016) Hemodynamic analysis of endoleaks after endovascular abdominal aortic aneurysm repair by using 4-dimensional flow-sensitive magnetic resonance imaging. Circ J 80:1715–1725PubMedCrossRef
80.
Zurück zum Zitat van Bogerijen GHW, van Herwaarden JA, Conti M, et al. (2014) Importance of dynamic aortic evaluation in planning TEVAR. Ann Cardiothorac Surg 3:300–306PubMedPubMedCentral van Bogerijen GHW, van Herwaarden JA, Conti M, et al. (2014) Importance of dynamic aortic evaluation in planning TEVAR. Ann Cardiothorac Surg 3:300–306PubMedPubMedCentral
81.
Zurück zum Zitat Resta EC, Secchi F, Giardino A, et al. (2013) Non-contrast MR imaging for detecting endoleak after abdominal endovascular aortic repair. Int J Cardiovasc Imaging 29:229–235PubMedCrossRef Resta EC, Secchi F, Giardino A, et al. (2013) Non-contrast MR imaging for detecting endoleak after abdominal endovascular aortic repair. Int J Cardiovasc Imaging 29:229–235PubMedCrossRef
82.
Zurück zum Zitat Baum RA, Carpenter JP, Golden MA, et al. (2002) Treatment of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms: comparison of transarterial and translumbar techniques. J Vasc Surg 35:23–29PubMedCrossRef Baum RA, Carpenter JP, Golden MA, et al. (2002) Treatment of type 2 endoleaks after endovascular repair of abdominal aortic aneurysms: comparison of transarterial and translumbar techniques. J Vasc Surg 35:23–29PubMedCrossRef
83.
Zurück zum Zitat Rosen RJ, Green RM (2008) Endoleak management following endovascular aneurysm repair. JVIR 19:S37–S43PubMedCrossRef Rosen RJ, Green RM (2008) Endoleak management following endovascular aneurysm repair. JVIR 19:S37–S43PubMedCrossRef
84.
Zurück zum Zitat Shah A, Stavropoulos SW (2009) Imaging surveillance following endovascular aneurysm repair. Semin Interv Radiol 26:10–16CrossRef Shah A, Stavropoulos SW (2009) Imaging surveillance following endovascular aneurysm repair. Semin Interv Radiol 26:10–16CrossRef
85.
Zurück zum Zitat Lifeline Registry of EVAR Publications Committee (2005) Lifeline registry of endovascular aneurysm repair: long-term primary outcome measures. J Vasc Surg 42:1–10CrossRef Lifeline Registry of EVAR Publications Committee (2005) Lifeline registry of endovascular aneurysm repair: long-term primary outcome measures. J Vasc Surg 42:1–10CrossRef
86.
Zurück zum Zitat Wilt TJ, Lederle FA, Macdonald R, et al. (2006) Comparison of endovascular and open surgical repairs for abdominal aortic aneurysm. Evid Rep Technol Assess (Full Rep) 144:1–113 Wilt TJ, Lederle FA, Macdonald R, et al. (2006) Comparison of endovascular and open surgical repairs for abdominal aortic aneurysm. Evid Rep Technol Assess (Full Rep) 144:1–113
87.
Zurück zum Zitat Stavropoulos SW, Clark TWI, Carpenter JP, et al. (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. JVIR 16:663–667PubMedCrossRef Stavropoulos SW, Clark TWI, Carpenter JP, et al. (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. JVIR 16:663–667PubMedCrossRef
88.
Zurück zum Zitat Ullery BW, Tran K, Itoga NK, Dalman RL, Lee JT (2017) Natural history of gutter-related type Ia endoleaks after snorkel/chimney endovascular aneurysm repair. J Vasc Surg 65:981–990PubMedPubMedCentralCrossRef Ullery BW, Tran K, Itoga NK, Dalman RL, Lee JT (2017) Natural history of gutter-related type Ia endoleaks after snorkel/chimney endovascular aneurysm repair. J Vasc Surg 65:981–990PubMedPubMedCentralCrossRef
89.
Zurück zum Zitat Ueda T, Takaoka H, Petrovitch I, Rubin GD (2014) Detection of broken sutures and metal-ring fractures in AneuRx stent-grafts by using three-dimensional CT angiography after endovascular abdominal aortic aneurysm repair: association with late endoleak development and device migration. Radiology 272:275–283PubMedCrossRef Ueda T, Takaoka H, Petrovitch I, Rubin GD (2014) Detection of broken sutures and metal-ring fractures in AneuRx stent-grafts by using three-dimensional CT angiography after endovascular abdominal aortic aneurysm repair: association with late endoleak development and device migration. Radiology 272:275–283PubMedCrossRef
90.
Zurück zum Zitat Arko FR, Rubin GD, Johnson BL, et al. (2001) Type-II endoleaks following endovascular AAA repair: preoperative predictors and long-term effects. J Endovasc Ther 8:503–510PubMedCrossRef Arko FR, Rubin GD, Johnson BL, et al. (2001) Type-II endoleaks following endovascular AAA repair: preoperative predictors and long-term effects. J Endovasc Ther 8:503–510PubMedCrossRef
91.
Zurück zum Zitat van Marrewijk CJ, Fransen G, Laheij RJF, Harris PL, Buth J (2004) EUROSTAR Collaborators. Is a type II endoleak after EVAR a harbinger of risk? Causes and outcome of open conversion and aneurysm rupture during follow-up. Eur J Vasc Endovasc Surg 27:128–137PubMedCrossRef van Marrewijk CJ, Fransen G, Laheij RJF, Harris PL, Buth J (2004) EUROSTAR Collaborators. Is a type II endoleak after EVAR a harbinger of risk? Causes and outcome of open conversion and aneurysm rupture during follow-up. Eur J Vasc Endovasc Surg 27:128–137PubMedCrossRef
92.
Zurück zum Zitat Jones JE, Atkins MD, Brewster DC, et al. (2007) Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomes. J Vasc Surg 46:1–8PubMedCrossRef Jones JE, Atkins MD, Brewster DC, et al. (2007) Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomes. J Vasc Surg 46:1–8PubMedCrossRef
93.
Zurück zum Zitat Veith FJ, Baum RA, Ohki T, et al. (2002) Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg 35:1029–1035PubMedCrossRef Veith FJ, Baum RA, Ohki T, et al. (2002) Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference. J Vasc Surg 35:1029–1035PubMedCrossRef
94.
Zurück zum Zitat Liaw JVP, Clark M, Gibbs R, et al. (2009) Update: complications and management of infrarenal EVAR. Eur J Radiol 71:541–551PubMedCrossRef Liaw JVP, Clark M, Gibbs R, et al. (2009) Update: complications and management of infrarenal EVAR. Eur J Radiol 71:541–551PubMedCrossRef
95.
Zurück zum Zitat Nolz R, Teufelsbauer H, Asenbaum U, et al. (2012) Type II endoleaks after endovascular repair of abdominal aortic aneurysms: fate of the aneurysm sac and neck changes during long-term follow-up. J Endovasc Ther 19:193–199PubMedCrossRef Nolz R, Teufelsbauer H, Asenbaum U, et al. (2012) Type II endoleaks after endovascular repair of abdominal aortic aneurysms: fate of the aneurysm sac and neck changes during long-term follow-up. J Endovasc Ther 19:193–199PubMedCrossRef
96.
Zurück zum Zitat Stavropoulos SW, Marin H, Fairman RM, et al. (2005) Recurrent endoleak detection and measurement of aneurysm size with CTA after coil embolization of endoleaks. JVIR 16:1313–1317PubMedCrossRef Stavropoulos SW, Marin H, Fairman RM, et al. (2005) Recurrent endoleak detection and measurement of aneurysm size with CTA after coil embolization of endoleaks. JVIR 16:1313–1317PubMedCrossRef
97.
Zurück zum Zitat Maleux G, Poorteman L, Laenen A, et al. (2017) Incidence, etiology, and management of type III endoleak after endovascular aortic repair. J Vasc Surg 66:1056–1064PubMedCrossRef Maleux G, Poorteman L, Laenen A, et al. (2017) Incidence, etiology, and management of type III endoleak after endovascular aortic repair. J Vasc Surg 66:1056–1064PubMedCrossRef
98.
Zurück zum Zitat Ricotta JJ (2010) Endoleak management and postoperative surveillance following endovascular repair of thoracic aortic aneurysms. J Vasc Surg 52:91S–99SPubMedCrossRef Ricotta JJ (2010) Endoleak management and postoperative surveillance following endovascular repair of thoracic aortic aneurysms. J Vasc Surg 52:91S–99SPubMedCrossRef
99.
Zurück zum Zitat Trocciola SM, Dayal R, Chaer RA, et al. (2006) The development of endotension is associated with increased transmission of pressure and serous components in porous expanded polytetrafluoroethylene stent-grafts: characterization using a canine model. J Vasc Surg 43:109–116PubMedCrossRef Trocciola SM, Dayal R, Chaer RA, et al. (2006) The development of endotension is associated with increased transmission of pressure and serous components in porous expanded polytetrafluoroethylene stent-grafts: characterization using a canine model. J Vasc Surg 43:109–116PubMedCrossRef
100.
Zurück zum Zitat Filippi F, Tirotti C, Stella N, Rizzo L, Taurino M (2013) Endotension-related aortic sac rupture treated by endograft relining. Vascular 21:113–115PubMedCrossRef Filippi F, Tirotti C, Stella N, Rizzo L, Taurino M (2013) Endotension-related aortic sac rupture treated by endograft relining. Vascular 21:113–115PubMedCrossRef
101.
Zurück zum Zitat Perry RJT, Martin MJ, Eckert MJ, Sohn VY, Steele SR (2008) Colonic ischemia complicating open vs endovascular abdominal aortic aneurysm repair. J Vasc Surg 48:272–277PubMedCrossRef Perry RJT, Martin MJ, Eckert MJ, Sohn VY, Steele SR (2008) Colonic ischemia complicating open vs endovascular abdominal aortic aneurysm repair. J Vasc Surg 48:272–277PubMedCrossRef
102.
Zurück zum Zitat Wald R, Waikar SS, Liangos O, et al. (2006) Acute renal failure after endovascular vs open repair of abdominal aortic aneurysm. J Vasc Surg 43:460–466 (Discussion 466)PubMedCrossRef Wald R, Waikar SS, Liangos O, et al. (2006) Acute renal failure after endovascular vs open repair of abdominal aortic aneurysm. J Vasc Surg 43:460–466 (Discussion 466)PubMedCrossRef
103.
Zurück zum Zitat Zettervall SL, Ultee KHJ, Soden PA, et al. (2017) Predictors of renal dysfunction after endovascular and open repair of abdominal aortic aneurysms. J Vasc Surg 65:991–996PubMedCrossRef Zettervall SL, Ultee KHJ, Soden PA, et al. (2017) Predictors of renal dysfunction after endovascular and open repair of abdominal aortic aneurysms. J Vasc Surg 65:991–996PubMedCrossRef
104.
Zurück zum Zitat Grant SW, Grayson AD, Grant MJ, Purkayastha D, McCollum CN (2012) What are the risk factors for renal failure following open elective abdominal aortic aneurysm repair? Eur J Vasc Endovasc Surg 43:182–187PubMedCrossRef Grant SW, Grayson AD, Grant MJ, Purkayastha D, McCollum CN (2012) What are the risk factors for renal failure following open elective abdominal aortic aneurysm repair? Eur J Vasc Endovasc Surg 43:182–187PubMedCrossRef
105.
Zurück zum Zitat Belenky A, Atar E, Orron DE, et al. (2014) Endovascular abdominal aortic aneurysm repair using transvenous intravascular US catheter guidance in patients with chronic renal failure. JVIR 25:702–706PubMedCrossRef Belenky A, Atar E, Orron DE, et al. (2014) Endovascular abdominal aortic aneurysm repair using transvenous intravascular US catheter guidance in patients with chronic renal failure. JVIR 25:702–706PubMedCrossRef
106.
Zurück zum Zitat Zarins CK, Bloch DA, Crabtree T, et al. (2003) Stent graft migration after endovascular aneurysm repair: importance of proximal fixation. J Vasc Surg 38:1264–1272 (Discussion 1272)PubMedCrossRef Zarins CK, Bloch DA, Crabtree T, et al. (2003) Stent graft migration after endovascular aneurysm repair: importance of proximal fixation. J Vasc Surg 38:1264–1272 (Discussion 1272)PubMedCrossRef
107.
Zurück zum Zitat Sampaio SM, Panneton JM, Mozes G, et al. (2005) AneuRx device migration: incidence, risk factors, and consequences. Ann Vasc Surg 19:178–185PubMedCrossRef Sampaio SM, Panneton JM, Mozes G, et al. (2005) AneuRx device migration: incidence, risk factors, and consequences. Ann Vasc Surg 19:178–185PubMedCrossRef
108.
Zurück zum Zitat Stavropoulos SW, Charagundla SR (2007) Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology 243:641–655PubMedCrossRef Stavropoulos SW, Charagundla SR (2007) Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology 243:641–655PubMedCrossRef
109.
Zurück zum Zitat Resch T, Ivancev K, Brunkwall J, et al. (1999) Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms. JVIR 10:257–264 (Discussion 265–276)PubMedCrossRef Resch T, Ivancev K, Brunkwall J, et al. (1999) Distal migration of stent-grafts after endovascular repair of abdominal aortic aneurysms. JVIR 10:257–264 (Discussion 265–276)PubMedCrossRef
110.
Zurück zum Zitat Spanos K, Karathanos C, Saleptsis V, Giannoukas AD (2016) Systematic review and meta-analysis of migration after endovascular abdominal aortic aneurysm repair. Vascular 24:323–336PubMedCrossRef Spanos K, Karathanos C, Saleptsis V, Giannoukas AD (2016) Systematic review and meta-analysis of migration after endovascular abdominal aortic aneurysm repair. Vascular 24:323–336PubMedCrossRef
111.
Zurück zum Zitat Pintoux D, Chaillou P, Azema L, et al. (2011) Long-term influence of suprarenal or infrarenal fixation on proximal neck dilatation and stentgraft migration after EVAR. Ann Vasc Surg 25:1012–1019PubMedCrossRef Pintoux D, Chaillou P, Azema L, et al. (2011) Long-term influence of suprarenal or infrarenal fixation on proximal neck dilatation and stentgraft migration after EVAR. Ann Vasc Surg 25:1012–1019PubMedCrossRef
112.
Zurück zum Zitat Rafii BY, Abilez OJ, Benharash P, Zarins CK (2008) Lateral movement of endografts within the aneurysm sac is an indicator of stent-graft instability. J Endovasc Ther 15:335–343PubMedCrossRef Rafii BY, Abilez OJ, Benharash P, Zarins CK (2008) Lateral movement of endografts within the aneurysm sac is an indicator of stent-graft instability. J Endovasc Ther 15:335–343PubMedCrossRef
113.
Zurück zum Zitat Hellinger JC (2005) Endovascular repair of thoracic and abdominal aortic aneurysms: pre- and postprocedural imaging. Tech Vasc Interv Radiol 8:2–15PubMedCrossRef Hellinger JC (2005) Endovascular repair of thoracic and abdominal aortic aneurysms: pre- and postprocedural imaging. Tech Vasc Interv Radiol 8:2–15PubMedCrossRef
114.
Zurück zum Zitat Maleux G, Koolen M, Heye S, Nevelsteen A (2008) Limb occlusion after endovascular repair of abdominal aortic aneurysms with supported endografts. JVIR 19:1409–1412PubMedCrossRef Maleux G, Koolen M, Heye S, Nevelsteen A (2008) Limb occlusion after endovascular repair of abdominal aortic aneurysms with supported endografts. JVIR 19:1409–1412PubMedCrossRef
115.
Zurück zum Zitat Fairman RM, Baum RA, Carpenter JP, et al. (2002) Limb interventions in patients undergoing treatment with an unsupported bifurcated aortic endograft system: a review of the Phase II EVT Trial. J Vasc Surg 36:118–126PubMedCrossRef Fairman RM, Baum RA, Carpenter JP, et al. (2002) Limb interventions in patients undergoing treatment with an unsupported bifurcated aortic endograft system: a review of the Phase II EVT Trial. J Vasc Surg 36:118–126PubMedCrossRef
116.
Zurück zum Zitat Mantas GK, Antonopoulos CN, Sfyroeras GS, et al. (2015) Factors predisposing to endograft limb occlusion after endovascular aortic repair. Eur J Vasc Endovasc Surg 49:39–44PubMedCrossRef Mantas GK, Antonopoulos CN, Sfyroeras GS, et al. (2015) Factors predisposing to endograft limb occlusion after endovascular aortic repair. Eur J Vasc Endovasc Surg 49:39–44PubMedCrossRef
117.
Zurück zum Zitat Maleux G, Koolen M, Heye S, Heremans B, Nevelsteen A (2008) Mural thrombotic deposits in abdominal aortic endografts are common and do not require additional treatment at short-term and midterm follow-up. JVIR 19:1558–1562PubMedCrossRef Maleux G, Koolen M, Heye S, Heremans B, Nevelsteen A (2008) Mural thrombotic deposits in abdominal aortic endografts are common and do not require additional treatment at short-term and midterm follow-up. JVIR 19:1558–1562PubMedCrossRef
118.
Zurück zum Zitat Fatima J, Duncan AA, de Grandis E, et al. (2013) Treatment strategies and outcomes in patients with infected aortic endografts. J Vasc Surg 58:371–379PubMedCrossRef Fatima J, Duncan AA, de Grandis E, et al. (2013) Treatment strategies and outcomes in patients with infected aortic endografts. J Vasc Surg 58:371–379PubMedCrossRef
119.
Zurück zum Zitat Sharif MA, Lee B, Lau LL, et al. (2007) Prosthetic stent graft infection after endovascular abdominal aortic aneurysm repair. J Vasc Surg 46:442–448PubMedCrossRef Sharif MA, Lee B, Lau LL, et al. (2007) Prosthetic stent graft infection after endovascular abdominal aortic aneurysm repair. J Vasc Surg 46:442–448PubMedCrossRef
120.
Zurück zum Zitat van den Berg HR, Leijdekkers VJ, Vahl A (2006) Aortic stent-graft infection following septic complications of a kidney stone. Cardiovasc Intervent Radiol 29:443–445PubMedCrossRef van den Berg HR, Leijdekkers VJ, Vahl A (2006) Aortic stent-graft infection following septic complications of a kidney stone. Cardiovasc Intervent Radiol 29:443–445PubMedCrossRef
121.
Zurück zum Zitat Bergqvist D, Björck M (2009) Secondary arterioenteric fistulation: a systematic literature analysis. Eur J Vasc Endovasc Surg 37:31–42PubMedCrossRef Bergqvist D, Björck M (2009) Secondary arterioenteric fistulation: a systematic literature analysis. Eur J Vasc Endovasc Surg 37:31–42PubMedCrossRef
122.
Zurück zum Zitat Becquemin J-P, Allaire E, Desgranges P, Kobeiter H (2005) Delayed complications following EVAR. Tech Vasc Interv Radiol 8:30–40PubMedCrossRef Becquemin J-P, Allaire E, Desgranges P, Kobeiter H (2005) Delayed complications following EVAR. Tech Vasc Interv Radiol 8:30–40PubMedCrossRef
123.
Zurück zum Zitat Mehta M, Paty PSK, Roddy SP, et al. (2011) Treatment options for delayed AAA rupture following endovascular repair. J Vasc Surg 53:14–20PubMedCrossRef Mehta M, Paty PSK, Roddy SP, et al. (2011) Treatment options for delayed AAA rupture following endovascular repair. J Vasc Surg 53:14–20PubMedCrossRef
124.
Zurück zum Zitat Hiramoto JS, Reilly LM, Schneider DB, et al. (2007) Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graft. J Vasc Surg 45:461–466 (Discussion 465)PubMedCrossRef Hiramoto JS, Reilly LM, Schneider DB, et al. (2007) Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graft. J Vasc Surg 45:461–466 (Discussion 465)PubMedCrossRef
125.
Zurück zum Zitat Bashir MR, Ferral H, Jacobs C, McCarthy W, Goldin M (2009) Endoleaks after endovascular abdominal aortic aneurysm repair: management strategies according to CT findings. AJR 192:W178–W186PubMedCrossRef Bashir MR, Ferral H, Jacobs C, McCarthy W, Goldin M (2009) Endoleaks after endovascular abdominal aortic aneurysm repair: management strategies according to CT findings. AJR 192:W178–W186PubMedCrossRef
126.
Zurück zum Zitat Alerci M, Oberson M, Fogliata A, et al. (2009) Prospective, intra individual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms. Eur Radiol 19:1223–1231PubMedCrossRef Alerci M, Oberson M, Fogliata A, et al. (2009) Prospective, intra individual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms. Eur Radiol 19:1223–1231PubMedCrossRef
127.
Zurück zum Zitat Eliason JL, Upchurch GR (2008) Endovascular abdominal aortic aneurysm repair. Circulation 117:1738–1744PubMedCrossRef Eliason JL, Upchurch GR (2008) Endovascular abdominal aortic aneurysm repair. Circulation 117:1738–1744PubMedCrossRef
Metadaten
Titel
Abdominal aortic aneurysms: pre- and post-procedural imaging
verfasst von
Richard L. Hallett
Brant W. Ullery
Dominik Fleischmann
Publikationsdatum
19.02.2018
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 5/2018
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-018-1520-5

Weitere Artikel der Ausgabe 5/2018

Abdominal Radiology 5/2018 Zur Ausgabe

Classics in Abdominal Imaging

The hourglass gallbladder

Classics in Abdominal Imaging

Double diaphragmatic contour

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Medizinstudium Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.