CT brain artefact due to air bubbles in the oil cooling system: characteristic band-like configuration on sagittal reformatted image

verfasst von: Simon Sin Man Wong, James Siu Wai Cheung, Tom Wai Kin Lee, Chris Siu Chun Tsai, Alex Wing Hung Ng

Erschienen in: Japanese Journal of Radiology | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To retrospectively review the imaging characteristics of CT artefacts due to air bubbles within the oil cooling system of the X-ray tube housing.

Materials and methods

Air bubbles were introduced into the oil cooling system of the X-ray tube housing during tube replacement in one of the CT scanners in the authors’ institution. All 126 CT brain studies performed in this period were retrospectively reviewed. One hundred and four studies were negative for artefacts. Artefacts were confirmed in 5 and considered probable in 17 studies, respectively. The imaging characteristics of artefacts in these 22 cases were analysed.

Results

All artefacts manifested as ill-defined hypoattenuations in the periventricular/subcortical white matter of bilateral cerebral hemispheres with/without involvement of the internal capsule and basal ganglia. The posterior fossa was also involved in two (40%) confirmed and four (24%) probable studies. A band-like configuration of hypoattenuations on sagittal images was observed in five (100%) confirmed and eight (47%) probable studies.

Conclusion

Air bubble artefacts manifested as hypoattenuations in the periventricular/subcortical white matter of the supratentorial brain. A characteristic band-like configuration was observed in the sagittal reformatted image, which is useful for differentiating it from periventricular small vessel disease.
Literatur
1.
Zurück zum Zitat McVey S, Kanodia AK, Dundas S, Main G, Pillai S, Prasad G, et al. “Air bubble artefact”: a new type of artefact on CT head examination. Clin Radiol. 2016;71(10):1059–65.CrossRefPubMed McVey S, Kanodia AK, Dundas S, Main G, Pillai S, Prasad G, et al. “Air bubble artefact”: a new type of artefact on CT head examination. Clin Radiol. 2016;71(10):1059–65.CrossRefPubMed
2.
Zurück zum Zitat Trieu N, Xia R, Loneragan R, Ridley L, Trieu J. Artefact on CT brain images caused by the presence of air bubbles in the cooling oil of the X-ray tube. J Med Imaging Radiat Oncol. 2017;61(2):197–203.CrossRefPubMed Trieu N, Xia R, Loneragan R, Ridley L, Trieu J. Artefact on CT brain images caused by the presence of air bubbles in the cooling oil of the X-ray tube. J Med Imaging Radiat Oncol. 2017;61(2):197–203.CrossRefPubMed
3.
Zurück zum Zitat Hedrick WR, Markovic MA, Short JH, Vera CD. Computed tomography artifact created by air in the X-ray tube oil. J Comput Assist Tomogr. 2016;40(1):67–70.CrossRefPubMed Hedrick WR, Markovic MA, Short JH, Vera CD. Computed tomography artifact created by air in the X-ray tube oil. J Comput Assist Tomogr. 2016;40(1):67–70.CrossRefPubMed
5.
Zurück zum Zitat Törmänen J, Rautiainen J, Tahvonen P, Leinonen K, Nieminen MT, Tervonen O. The, “air in the CT X-ray tube oil” artifact—examples of the quality control images and the evaluation of four potential clinical patients’ head computed tomography cases. J Comput Assist Tomogr. 2017;41(3):489–93.CrossRefPubMed Törmänen J, Rautiainen J, Tahvonen P, Leinonen K, Nieminen MT, Tervonen O. The, “air in the CT X-ray tube oil” artifact—examples of the quality control images and the evaluation of four potential clinical patients’ head computed tomography cases. J Comput Assist Tomogr. 2017;41(3):489–93.CrossRefPubMed
6.
Zurück zum Zitat Filippi M, Rocca MA, Ciccarelli O, De Stefano N, Evangelou N, Kappos L, et al. MRI criteria for the diagnosis of multiple sclerosis: MAGNIMS consensus guidelines. Lancet Neurol. 2016;15(3):292–303.CrossRefPubMedPubMedCentral Filippi M, Rocca MA, Ciccarelli O, De Stefano N, Evangelou N, Kappos L, et al. MRI criteria for the diagnosis of multiple sclerosis: MAGNIMS consensus guidelines. Lancet Neurol. 2016;15(3):292–303.CrossRefPubMedPubMedCentral
Metadaten
Titel
CT brain artefact due to air bubbles in the oil cooling system: characteristic band-like configuration on sagittal reformatted image
verfasst von
Simon Sin Man Wong
James Siu Wai Cheung
Tom Wai Kin Lee
Chris Siu Chun Tsai
Alex Wing Hung Ng
Publikationsdatum
08.11.2017
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 2/2018
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-017-0702-3

Weitere Artikel der Ausgabe 2/2018

Japanese Journal of Radiology 2/2018 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

„Nur wer sich gut aufgehoben fühlt, kann auch für Patientensicherheit sorgen“

13.04.2024 Klinik aktuell Kongressbericht

Die Teilnehmer eines Forums beim DGIM-Kongress waren sich einig: Fehler in der Medizin sind häufig in ungeeigneten Prozessen und mangelnder Kommunikation begründet. Gespräche mit Patienten und im Team können helfen.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.