Abstract

Small-diameter biotube vascular grafts developed by in-body tissue architecture had high patency at implantation into rabbit carotid arteries or rat abdominal aortas. However, the thin walls (34 ± 14 μm) of the original biotubes made their implantation difficult into areas with low blood flow volumes or low blood pressure due to insufficient mechanical strength to maintain luminal shape. In this study, caged molds with several windows were designed to prepare more robust biotubes. The molds were assembled with silicone tubes (external diameter 2 mm) and cylindrical covers (outer diameter 7 mm) with 12 linear windows (1 × 9 mm). After the molds were embedded into beagle dorsal subcutaneous pouches for 4 weeks, type C (cage) biotubes were obtained by completely extracting the surrounding connective tissues from the molds and removing the molds. The biotube walls (778 ± 31 μm) were formed at the aperture (width 1 mm) between the silicone rods and the covers by connective cell migration through the windows of the covers. Excellent mechanical properties (external pressure resistance, approximately 4 times higher than beagle native femoral arteries; burst strength, approximately 2 times higher than original biotubes) were obtained. In the acute phase of implantation of the biotubes into beagle femoral arteries, perfect patency was obtained with little stenosis and no aneurysmal dilation. The type C biotubes may be useful for implantation into peripheral arteries or veins in addition to aortas.
Literatur
1.
Zurück zum Zitat Esquivel CO, Blaisdell FW. Why small vascular grafts fail: a review of clinical and experimental experience and the significance of the interaction of blood at the interface. J Surg Res. 1986;41:1–15.CrossRefPubMed Esquivel CO, Blaisdell FW. Why small vascular grafts fail: a review of clinical and experimental experience and the significance of the interaction of blood at the interface. J Surg Res. 1986;41:1–15.CrossRefPubMed
2.
Zurück zum Zitat Watanabe T, Kanda K, Yamanami M, Ishibashi-Ueda H, Yaku H, Nakayama Y. Long-term animal implantation study of biotube-autologous small-caliber vascular graft fabricated by in-body tissue architecture. J Biomed Mater Res B Appl Biomater. 2011;98:120–6.CrossRefPubMed Watanabe T, Kanda K, Yamanami M, Ishibashi-Ueda H, Yaku H, Nakayama Y. Long-term animal implantation study of biotube-autologous small-caliber vascular graft fabricated by in-body tissue architecture. J Biomed Mater Res B Appl Biomater. 2011;98:120–6.CrossRefPubMed
3.
Zurück zum Zitat Yamanami M, Ishibashi-Ueda H, Yamamoto A, Iida H, Watanabe T, Kanda K, Yaku H, Nakyama Y. Implantation study of small-caliber “biotube” vascular grafts in a rat model. J Artif Organs. 2013;16:59–65.CrossRefPubMed Yamanami M, Ishibashi-Ueda H, Yamamoto A, Iida H, Watanabe T, Kanda K, Yaku H, Nakyama Y. Implantation study of small-caliber “biotube” vascular grafts in a rat model. J Artif Organs. 2013;16:59–65.CrossRefPubMed
4.
Zurück zum Zitat Sakai O, Kanda K, Takamizawa K, Sato T, Yaku H, Nakayama Y. Faster and stronger vascular “Biotube” graft fabrication in vivo using a novel nicotine-containing mold. J Biomed Mater Res B Appl Biomater. 2009;90:412–20.PubMed Sakai O, Kanda K, Takamizawa K, Sato T, Yaku H, Nakayama Y. Faster and stronger vascular “Biotube” graft fabrication in vivo using a novel nicotine-containing mold. J Biomed Mater Res B Appl Biomater. 2009;90:412–20.PubMed
5.
Zurück zum Zitat Nakayama Y, Tsujinaka T. Acceleration of robust “biotube” vascular graft fabrication by in-body tissue architecture technology using novel eosin Y-releasing mold. J Biomed Mater Res B Appl Biomater. 2014;102:231–8.CrossRefPubMed Nakayama Y, Tsujinaka T. Acceleration of robust “biotube” vascular graft fabrication by in-body tissue architecture technology using novel eosin Y-releasing mold. J Biomed Mater Res B Appl Biomater. 2014;102:231–8.CrossRefPubMed
6.
Zurück zum Zitat Sakai O, Kanda K, Ishibashi-Ueda H, Takamizawa K, Ametani A, Yaku H, Nakayama Y. Development of the wing-attached rod for acceleration of “Biotube” vascular grafts fabrication in vivo. J Biomed Mater Res B Appl Biomater. 2007;83:240–7.CrossRefPubMed Sakai O, Kanda K, Ishibashi-Ueda H, Takamizawa K, Ametani A, Yaku H, Nakayama Y. Development of the wing-attached rod for acceleration of “Biotube” vascular grafts fabrication in vivo. J Biomed Mater Res B Appl Biomater. 2007;83:240–7.CrossRefPubMed
7.
Zurück zum Zitat Oie T, Yamanami M, Ishibahi-Ueda H, Kanda K, Yaku H, Nakayama Y. In-body optical stimulation formed connective tissue vascular grafts, “biotubes”, with many capillaries and elastic fibers. J Artif Organs. 2010;13:235–40.CrossRefPubMed Oie T, Yamanami M, Ishibahi-Ueda H, Kanda K, Yaku H, Nakayama Y. In-body optical stimulation formed connective tissue vascular grafts, “biotubes”, with many capillaries and elastic fibers. J Artif Organs. 2010;13:235–40.CrossRefPubMed
8.
Zurück zum Zitat Hayashi K, Handa H, Nagasawa S, Okumura A, Moritake K. Stiffness and elastic behavior of human intracranial and extracranial arteries. J Biomech. 1980;13:175–84.CrossRefPubMed Hayashi K, Handa H, Nagasawa S, Okumura A, Moritake K. Stiffness and elastic behavior of human intracranial and extracranial arteries. J Biomech. 1980;13:175–84.CrossRefPubMed
9.
Zurück zum Zitat Hayashi K, Nakamura T. Material test system for the evaluation of mechanical properties of biomaterials. J Biomed Mater Res. 1985;19:133–44.CrossRefPubMed Hayashi K, Nakamura T. Material test system for the evaluation of mechanical properties of biomaterials. J Biomed Mater Res. 1985;19:133–44.CrossRefPubMed
10.
Zurück zum Zitat Hayashi K, Igarashi Y, Takamizawa K. Mechanical properties and hemodynamics in coronary arteries. In: Kitamura K, Abe H, Sagawa K, editors. New approaches in cardiac mechanics. Tokyo: Japan Scientific Societies Press; 1986. p. 285–94. Hayashi K, Igarashi Y, Takamizawa K. Mechanical properties and hemodynamics in coronary arteries. In: Kitamura K, Abe H, Sagawa K, editors. New approaches in cardiac mechanics. Tokyo: Japan Scientific Societies Press; 1986. p. 285–94.
11.
Zurück zum Zitat Nakayama Y, Takewa Y, Sumikura H, Yamnami M, Matui Y, Oie T, Kishimoto Y, Arakawa M, Ohmura K, Kajikawa T, Kanda K, Tatsumi E. In-body tissue-engineered aortic valve (Biovalve type VII) architecture based on 3D printer molding. J Biomed Mater Res B Appl Biomater. 2015;103:1–11.CrossRefPubMed Nakayama Y, Takewa Y, Sumikura H, Yamnami M, Matui Y, Oie T, Kishimoto Y, Arakawa M, Ohmura K, Kajikawa T, Kanda K, Tatsumi E. In-body tissue-engineered aortic valve (Biovalve type VII) architecture based on 3D printer molding. J Biomed Mater Res B Appl Biomater. 2015;103:1–11.CrossRefPubMed
12.
Zurück zum Zitat Funayama M, Takewa Y, Oie T, Matsui Y, Tatsumi E, Nakayama Y. In situ observation and enhancement of leaflet tissue formation in bioprosthetic “biovalve”. J Artif Organs. 2015;18:40–7.CrossRefPubMed Funayama M, Takewa Y, Oie T, Matsui Y, Tatsumi E, Nakayama Y. In situ observation and enhancement of leaflet tissue formation in bioprosthetic “biovalve”. J Artif Organs. 2015;18:40–7.CrossRefPubMed
13.
Zurück zum Zitat Madras PN, Ward CA, Johnson WR, Singh PI. Anastomotic hyperplasia. Surgery. 1981;90:922–3.PubMed Madras PN, Ward CA, Johnson WR, Singh PI. Anastomotic hyperplasia. Surgery. 1981;90:922–3.PubMed
14.
Zurück zum Zitat Watanabe T, Kanda K, Ishibashi-Ueda H, Yaku H, Nakayama Y. Autologous small-caliber “biotube” vascular grafts with argatroban loading: a histomorphological examination after implantation to rabbits. J Biomed Mater Res B Appl Biomater. 2010;92:236–42.CrossRefPubMed Watanabe T, Kanda K, Ishibashi-Ueda H, Yaku H, Nakayama Y. Autologous small-caliber “biotube” vascular grafts with argatroban loading: a histomorphological examination after implantation to rabbits. J Biomed Mater Res B Appl Biomater. 2010;92:236–42.CrossRefPubMed
15.
Zurück zum Zitat Klinkert P, van Dijk PJ, Breslau PJ. Polytetrafluoroethylene femorotibial bypass grafting: 5-year patency and limb salvage. Ann Vasc Surg. 2003;17:486–91.CrossRefPubMed Klinkert P, van Dijk PJ, Breslau PJ. Polytetrafluoroethylene femorotibial bypass grafting: 5-year patency and limb salvage. Ann Vasc Surg. 2003;17:486–91.CrossRefPubMed
16.
Zurück zum Zitat Arena FJ. Arterial kink and damage in normal segments of the superficial femoral and popliteal arteries abutting nitinol stents-a common cause of late occlusion and restenosis? A single-center experience. J Invasive Cardiol. 2005;17:482–6.PubMed Arena FJ. Arterial kink and damage in normal segments of the superficial femoral and popliteal arteries abutting nitinol stents-a common cause of late occlusion and restenosis? A single-center experience. J Invasive Cardiol. 2005;17:482–6.PubMed
17.
Zurück zum Zitat Campbell GR, Campbell JH. Development of tissue engineered vascular grafts. Curr Pharm Biotechnol. 2007;8:43–50.CrossRefPubMed Campbell GR, Campbell JH. Development of tissue engineered vascular grafts. Curr Pharm Biotechnol. 2007;8:43–50.CrossRefPubMed
Metadaten
Titel
Development of an in vivo tissue-engineered vascular graft with designed wall thickness (biotube type C) based on a novel caged mold
verfasst von
Maya Furukoshi
Takeshi Moriwaki
Yasuhide Nakayama
Publikationsdatum
01.03.2016
Verlag
Springer Japan
Erschienen in
Journal of Artificial Organs / Ausgabe 1/2016
Print ISSN: 1434-7229
Elektronische ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-015-0859-4

Weitere Artikel der Ausgabe 1/2016

Journal of Artificial Organs 1/2016 Zur Ausgabe

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.