Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 5/2003

01.09.2003 | Knee

Graft choice and graft fixation in PCL reconstruction

verfasst von: Jürgen Höher, Sven Scheffler, Andreas Weiler

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 5/2003

Einloggen, um Zugang zu erhalten

Abstract

Several grafts and several fixation techniques have been introduced for PCL reconstruction over the past years. To date, autograft and allograft tissues are recommended for PCL reconstruction, whilst synthetic grafts should be avoided. Autograft tissues include the bone-patellar tendon-bone graft, the hamstrings and the quadriceps tendon. Allograft tissues are increasingly being used for primary PCL reconstruction. The use of allograft tissues requires a number of formal prerequisites to be fulfilled. Besides the previous mentioned graft types allograft tissues include Achilles and tibialis anterior/posterior tendons. To date no superior graft type has been identified. Several techniques and devices have been used for fixation of a PCL replacement graft. Most of these were originally developed for ACL reconstruction and then adapted to PCL reconstruction. However, biomechanical requirements of the PCL differ substantially from those of the ACL. To date, requirements for PCL graft fixations are not known. From a systematic approach femoral graft fixation can either be achieved within the bone tunnel (nearly anatomic) with an interference screw or outside the bone tunnel on the medial femoral condyle using a staple, an endobutton or a screw. Tibial graft fixation can be achieved either with an interference screw in the bone tunnel or with a staple, screw/washer or sutures tied over a bone bridge outside the bone tunnel (extra-anatomic). An alternative fixation on the tibial side is the inlay technique that reduces the acute angulation of the graft at the posterior aspect of the tibia. Further research is necessary to identify the differences between the various fixation techniques.
Literatur
1.
Zurück zum Zitat Becker R, Voigt D, Stärke C (2001) Biomechanical properties of quadruple tendon and patellar tendon femoral fixation techniques. Knee Surg Sports Traumatol Arthrosc 9:337–342CrossRefPubMed Becker R, Voigt D, Stärke C (2001) Biomechanical properties of quadruple tendon and patellar tendon femoral fixation techniques. Knee Surg Sports Traumatol Arthrosc 9:337–342CrossRefPubMed
2.
Zurück zum Zitat Berg EE (1995) Posterior cruciate ligament tibial inlay reconstruction. Arthroscopy 11:69–76PubMed Berg EE (1995) Posterior cruciate ligament tibial inlay reconstruction. Arthroscopy 11:69–76PubMed
3.
Zurück zum Zitat Bergfeld JA, Mc Allister DR, Parker RD, Valdevit ADC, Kambic HE (2001) A biomechanical comparison of PCL reconstruction techniques. Am J Sports Med 29:129–136PubMed Bergfeld JA, Mc Allister DR, Parker RD, Valdevit ADC, Kambic HE (2001) A biomechanical comparison of PCL reconstruction techniques. Am J Sports Med 29:129–136PubMed
4.
Zurück zum Zitat Black KP, Saunders MM, Stube KC, Moulton MJ (2000) Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction. Am J Sports Med 28:846–849PubMed Black KP, Saunders MM, Stube KC, Moulton MJ (2000) Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction. Am J Sports Med 28:846–849PubMed
5.
Zurück zum Zitat Brand J, Hamilton D, Selby J, Pienkowski D, Caborn DN, Johnson DL (2000) Biomechanical comparison of quadriceps tendon fixation with patellar tendon bone plug interference fixation in cruciate ligament reconstruction. Arthroscopy 16:805–812PubMed Brand J, Hamilton D, Selby J, Pienkowski D, Caborn DN, Johnson DL (2000) Biomechanical comparison of quadriceps tendon fixation with patellar tendon bone plug interference fixation in cruciate ligament reconstruction. Arthroscopy 16:805–812PubMed
6.
Zurück zum Zitat Brand J, Jr., Weiler A, Caborn DN, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed Brand J, Jr., Weiler A, Caborn DN, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed
7.
Zurück zum Zitat Brown CH Jr, Steiner ME, Carson EW (1993) The use of hamstring tendons for anterior cruciate ligament reconstruction. Technique and results. Clin Sports Med 12:723–756PubMed Brown CH Jr, Steiner ME, Carson EW (1993) The use of hamstring tendons for anterior cruciate ligament reconstruction. Technique and results. Clin Sports Med 12:723–756PubMed
8.
Zurück zum Zitat Butler DL, Noyes FR, Grood ES (1980) Ligamentous restraints to anterior-posterior drawer in the human knee. A biomechanical study. J Bone Joint Surg Am 62:259–270PubMed Butler DL, Noyes FR, Grood ES (1980) Ligamentous restraints to anterior-posterior drawer in the human knee. A biomechanical study. J Bone Joint Surg Am 62:259–270PubMed
9.
Zurück zum Zitat Caborn DN, Coen M, Neef R, Hamilton D, Nyland J, Johnson DL (1998) Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw. Arthroscopy 14:241–245PubMed Caborn DN, Coen M, Neef R, Hamilton D, Nyland J, Johnson DL (1998) Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw. Arthroscopy 14:241–245PubMed
10.
Zurück zum Zitat Cooper DE, Deng XH, Burstein AL, Warren RF (1993) The strength of the central third patellar tendon graft. A biomechanical study. Am J Sports Med 21:818-824PubMed Cooper DE, Deng XH, Burstein AL, Warren RF (1993) The strength of the central third patellar tendon graft. A biomechanical study. Am J Sports Med 21:818-824PubMed
11.
Zurück zum Zitat Fox RJ, Harner CD, Sakane M, Carlin GJ, Woo SL (1998) In situ forces in the human posterior cruciate ligament: a cadaveric study. Am J Sports Med 26:395–401PubMed Fox RJ, Harner CD, Sakane M, Carlin GJ, Woo SL (1998) In situ forces in the human posterior cruciate ligament: a cadaveric study. Am J Sports Med 26:395–401PubMed
12.
Zurück zum Zitat Frank CB, Jackson DW (1997) The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Am 79:1556–1576PubMed Frank CB, Jackson DW (1997) The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Am 79:1556–1576PubMed
13.
Zurück zum Zitat Fulkerson JP, Langeland RH (1996) The central quadriceps tendon graft for cruciate ligament reconstruction. Oper Tech Orthop 6:135–137 Fulkerson JP, Langeland RH (1996) The central quadriceps tendon graft for cruciate ligament reconstruction. Oper Tech Orthop 6:135–137
14.
Zurück zum Zitat Girgis FG, Marshall JL, Al Monajem ARS (1975) The cruciate ligaments of the knee joint: anatomical and experimental analysis. Clin Orthop 106:216–231PubMed Girgis FG, Marshall JL, Al Monajem ARS (1975) The cruciate ligaments of the knee joint: anatomical and experimental analysis. Clin Orthop 106:216–231PubMed
15.
Zurück zum Zitat Hamner DL, Brown C, Steiner ME, Hecker AT, Hayes WC (1999) Hamstring tendon grafts for reconstruction of the anterior cruciate ligament. biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg Am 81:549–557PubMed Hamner DL, Brown C, Steiner ME, Hecker AT, Hayes WC (1999) Hamstring tendon grafts for reconstruction of the anterior cruciate ligament. biomechanical evaluation of the use of multiple strands and tensioning techniques. J Bone Joint Surg Am 81:549–557PubMed
16.
Zurück zum Zitat Harner CD, Höher J (1995) The human posterior cruciate ligament complex: an interdisciplinary study. Ligament morphology and biomechanical evaluation. Am J Sports Med 23:736–745PubMed Harner CD, Höher J (1995) The human posterior cruciate ligament complex: an interdisciplinary study. Ligament morphology and biomechanical evaluation. Am J Sports Med 23:736–745PubMed
17.
Zurück zum Zitat Harner CD, Höher J (1998) Evaluation and treatment of posterior cruciate ligament injuries. Am J Sports Med 26:471–482PubMed Harner CD, Höher J (1998) Evaluation and treatment of posterior cruciate ligament injuries. Am J Sports Med 26:471–482PubMed
18.
Zurück zum Zitat Harner CD, Vogrin TM, Höher J, Ma CB, Woo SL (2000) Biomechanical analysis of a posterior cruciate ligament reconstruction. Deficiency of the posterolateral structures as a cause of graft failure. Am J Sports Med 28:32–39PubMed Harner CD, Vogrin TM, Höher J, Ma CB, Woo SL (2000) Biomechanical analysis of a posterior cruciate ligament reconstruction. Deficiency of the posterolateral structures as a cause of graft failure. Am J Sports Med 28:32–39PubMed
19.
Zurück zum Zitat Harner CD, Xerogeanes JW, Livesay GA, Carlin GJ, Smith BA, Kusayama T, Kashiwaguchi S, Woo SL (2000) Biomechanical analysis of a double-bundle posterior cruciate ligement reconstruction. Am J Sports Med 28:144–151PubMed Harner CD, Xerogeanes JW, Livesay GA, Carlin GJ, Smith BA, Kusayama T, Kashiwaguchi S, Woo SL (2000) Biomechanical analysis of a double-bundle posterior cruciate ligement reconstruction. Am J Sports Med 28:144–151PubMed
20.
Zurück zum Zitat Höher J, Scheffler SU, Withrow JD, Debski R, Fu FH, Woo SL-Y (2000) Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament. J Orthop Res 18:456–461PubMed Höher J, Scheffler SU, Withrow JD, Debski R, Fu FH, Woo SL-Y (2000) Mechanical behavior of two hamstring graft constructs for reconstruction of the anterior cruciate ligament. J Orthop Res 18:456–461PubMed
21.
Zurück zum Zitat Höher J, Vogrin TM, Woo SL, Carlin GJ, Aroen A, Harner CD (1999) In situ forces in the human posterior cruciate ligament in response to muscle loads: a cadaveric study. J Orthop Res 17:763PubMed Höher J, Vogrin TM, Woo SL, Carlin GJ, Aroen A, Harner CD (1999) In situ forces in the human posterior cruciate ligament in response to muscle loads: a cadaveric study. J Orthop Res 17:763PubMed
22.
Zurück zum Zitat Kousa P, Jarvinen TL, Pohjonen T, Kannus P, Kotikoski M, Jarvinen M (1995) Fixation strength of a biodegradable screw in anterior cruciate ligament reconstruction. J Bone Joint Surg Br 77:901–905PubMed Kousa P, Jarvinen TL, Pohjonen T, Kannus P, Kotikoski M, Jarvinen M (1995) Fixation strength of a biodegradable screw in anterior cruciate ligament reconstruction. J Bone Joint Surg Br 77:901–905PubMed
23.
Zurück zum Zitat Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15:225–229PubMed Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15:225–229PubMed
24.
Zurück zum Zitat Markolf KL, Zemanivic JR, Mc Allister DR (2002) Cyclic loading of posterior cruciate ligament replacements fixed with tibial tunnel and tibial inlay methods. J Bone Joint Surg Am 84:518–524CrossRef Markolf KL, Zemanivic JR, Mc Allister DR (2002) Cyclic loading of posterior cruciate ligament replacements fixed with tibial tunnel and tibial inlay methods. J Bone Joint Surg Am 84:518–524CrossRef
25.
Zurück zum Zitat Morrison JB (1970) Mechanics of the knee joint in relation to normal walking. J Biomech 3:51–61PubMed Morrison JB (1970) Mechanics of the knee joint in relation to normal walking. J Biomech 3:51–61PubMed
26.
Zurück zum Zitat Nagano M, Yoshiya S, Kuroda R, Kurosaka M, Mizuno K (1997) Remodeling and healing process of bone-patellar tendon bone graft in a bone tunnel. Trans Orthop Res Soc:78 Nagano M, Yoshiya S, Kuroda R, Kurosaka M, Mizuno K (1997) Remodeling and healing process of bone-patellar tendon bone graft in a bone tunnel. Trans Orthop Res Soc:78
27.
Zurück zum Zitat Nargakatti DG, Mc Keon BP, Donahue BS,Fulkerson JP (2001) Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29:67–71PubMed Nargakatti DG, Mc Keon BP, Donahue BS,Fulkerson JP (2001) Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am J Sports Med 29:67–71PubMed
28.
Zurück zum Zitat Race A, Amis AA (1998) PCL reconstruction. In vitro biomechanical comparison of 'isometric' versus single and double-bundled 'anatomic' grafts. J Bone Joint Surg Br 80:173–179PubMed Race A, Amis AA (1998) PCL reconstruction. In vitro biomechanical comparison of 'isometric' versus single and double-bundled 'anatomic' grafts. J Bone Joint Surg Br 80:173–179PubMed
29.
Zurück zum Zitat Rodeo SA, Arnoczky SP, Torzilli PA, Hidaka C, Warren RF (1993) Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog. J Bone Joint Surg Am 75:1795–1803PubMed Rodeo SA, Arnoczky SP, Torzilli PA, Hidaka C, Warren RF (1993) Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog. J Bone Joint Surg Am 75:1795–1803PubMed
30.
Zurück zum Zitat Scheffler S, Sudkamp N, A G, Hoffmann R, Weiler A (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315CrossRefPubMed Scheffler S, Sudkamp N, A G, Hoffmann R, Weiler A (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315CrossRefPubMed
31.
Zurück zum Zitat Selby JB, Johnson DL, Hester P, Caborn DN (2001) Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel. Am J Sports Med 29:614–619PubMed Selby JB, Johnson DL, Hester P, Caborn DN (2001) Effect of screw length on bioabsorbable interference screw fixation in a tibial bone tunnel. Am J Sports Med 29:614–619PubMed
32.
Zurück zum Zitat Staubli HU, Schatzmann L, Brunner P, Rincon L, Nolte LP (1996) Quadriceps tendon and patellar ligament: cryosectional anatomy and structural properties in young adults. Knee Surg Sports Traumatol Arthrosc 4:100–110 Staubli HU, Schatzmann L, Brunner P, Rincon L, Nolte LP (1996) Quadriceps tendon and patellar ligament: cryosectional anatomy and structural properties in young adults. Knee Surg Sports Traumatol Arthrosc 4:100–110
33.
Zurück zum Zitat Steiner ME, Hecker AT, Brown CH Jr, Hayes WC (1994) Anterior cruciate ligament graft fixation. Comparison of hamstring and patellar tendon grafts. Am J Sports Med 22:240–247PubMed Steiner ME, Hecker AT, Brown CH Jr, Hayes WC (1994) Anterior cruciate ligament graft fixation. Comparison of hamstring and patellar tendon grafts. Am J Sports Med 22:240–247PubMed
34.
Zurück zum Zitat Toutongi DE, Lu TW, Leardini A, Catani F, O'Connor JJ (2000) Cruciate ligament forces in the human knee during rehabilitation exercises. Clin Biomech (Bristol, Avon) Toutongi DE, Lu TW, Leardini A, Catani F, O'Connor JJ (2000) Cruciate ligament forces in the human knee during rehabilitation exercises. Clin Biomech (Bristol, Avon)
35.
Zurück zum Zitat Vogrin TM, Höher J, Aroen A, Woo SL, Harner CD (2000) Effects of sectioning the posterolateral structures on knee kinematics and in situ forces in the posterior cruciate ligament. Knee Surg Sports Traumatol Arthrosc 8:93–98PubMed Vogrin TM, Höher J, Aroen A, Woo SL, Harner CD (2000) Effects of sectioning the posterolateral structures on knee kinematics and in situ forces in the posterior cruciate ligament. Knee Surg Sports Traumatol Arthrosc 8:93–98PubMed
36.
Zurück zum Zitat Weiler A, Hoffmann R, Stahelin A, Bail H, Siepe C, Sudkamp N (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16:305–321PubMed Weiler A, Hoffmann R, Stahelin A, Bail H, Siepe C, Sudkamp N (2000) Biodegradable implants in sports medicine: the biological base. Arthroscopy 16:305–321PubMed
37.
Zurück zum Zitat Weiler A, Hoffmann RF, Stahelin AC, Helling HJ, Sudkamp NP (2001) The endopearl device increases fixation strength and eliminates construct slippage of hamstring tendon grafts with interference screw fixation. Arthroscopy 17:353–359PubMed Weiler A, Hoffmann RF, Stahelin AC, Helling HJ, Sudkamp NP (2001) The endopearl device increases fixation strength and eliminates construct slippage of hamstring tendon grafts with interference screw fixation. Arthroscopy 17:353–359PubMed
38.
Zurück zum Zitat Weiler A, Richter M, Schmidmaier G, Kandziora F, Südkamp N (1998) Hamstring tendon fixation using interference screws: a biomechanical study in calf tibia bone. Arthroscopy 14:29–37PubMed Weiler A, Richter M, Schmidmaier G, Kandziora F, Südkamp N (1998) Hamstring tendon fixation using interference screws: a biomechanical study in calf tibia bone. Arthroscopy 14:29–37PubMed
39.
Zurück zum Zitat Woo SL-Y, Hollis JM, Adams DJ, Lyon RM, Takai S (1991) Tensile properties of the human femur-anterior cruciate ligament-tibia complex: the effects of specimen age and orientation. Am J Sports Med 19:217–225PubMed Woo SL-Y, Hollis JM, Adams DJ, Lyon RM, Takai S (1991) Tensile properties of the human femur-anterior cruciate ligament-tibia complex: the effects of specimen age and orientation. Am J Sports Med 19:217–225PubMed
40.
Zurück zum Zitat Zheng N, Lleisig GS, Escakmmilla RF, Barrentine SW (1998) An analytical model of the knee for estimation of internal forces during exercise. J Biomech 31:963–967PubMed Zheng N, Lleisig GS, Escakmmilla RF, Barrentine SW (1998) An analytical model of the knee for estimation of internal forces during exercise. J Biomech 31:963–967PubMed
Metadaten
Titel
Graft choice and graft fixation in PCL reconstruction
verfasst von
Jürgen Höher
Sven Scheffler
Andreas Weiler
Publikationsdatum
01.09.2003
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 5/2003
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-003-0408-1

Weitere Artikel der Ausgabe 5/2003

Knee Surgery, Sports Traumatology, Arthroscopy 5/2003 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.