Abstract

Background

All computer-aided surgery technologies assume that the surgeon knows the best position for the implant components. However, there is indirect evidence that simple anatomical information may not be sufficient for the surgeon to decide size and position of the implant in a repeatable manner.

Method

In the present study we estimated the variability in choosing the size and position of the components of a cementless total hip replacement (THR), using template-on-radiograph as well as computed tomography (CT)-based computer-aided planning. In addition, using a computer model, we assessed the sensitivity to such variability of implant fitting, location of the joint centre, skeletal range of motion, and resting length of major hip muscles. Using templates, surgeons selected the size with variability up to 2.5 mm for the stem and up to 4 mm for the socket. A similar variability was also observed when the CT-based planning program was used.

Results

No major differences were found between surgeons. The standard deviation over repeated planning sessions of the selected position for each component, using the CT-based planning software, was found to be 3.9 mm and 8.9°.

Conclusion

On the basis of the computer simulation, this variability did not affect the selected biomechanical parameters in a drastic way, although some differences were observed, especially in the lever arm of the hip muscles.
Literatur
1.
Zurück zum Zitat Stea S, Bordini B, Sudanese A, Toni A (2002) Register of hip prosthesis at Rizzoli Institute: eleven years’ experience. Acta Orthop Scand 73:43–45CrossRef Stea S, Bordini B, Sudanese A, Toni A (2002) Register of hip prosthesis at Rizzoli Institute: eleven years’ experience. Acta Orthop Scand 73:43–45CrossRef
2.
Zurück zum Zitat Bargar WL, Bauer A, Borner M (1998) Primary and revision total hip replacement using the Robodoc system. Clin Orthop 354:82–91CrossRefPubMed Bargar WL, Bauer A, Borner M (1998) Primary and revision total hip replacement using the Robodoc system. Clin Orthop 354:82–91CrossRefPubMed
3.
Zurück zum Zitat DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8–22PubMed DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8–22PubMed
4.
Zurück zum Zitat Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg 7:99–106CrossRefPubMed Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study. Comput Aided Surg 7:99–106CrossRefPubMed
5.
Zurück zum Zitat Thomsen MN, Breusch SJ, Aldinger PR, Gortz W, Lahmer A, Honl M, Birke A, Nagerl H (2002) Robotically-milled bone cavities: a comparison with hand-broaching in different types of cementless hip stems. Acta Orthop Scand 73:379–385CrossRefPubMed Thomsen MN, Breusch SJ, Aldinger PR, Gortz W, Lahmer A, Honl M, Birke A, Nagerl H (2002) Robotically-milled bone cavities: a comparison with hand-broaching in different types of cementless hip stems. Acta Orthop Scand 73:379–385CrossRefPubMed
6.
Zurück zum Zitat Nogler M, Krismer M, Haid C, Ogon M, Bach C, Wimmer C (2001) Excessive heat generation during cutting of cement in the Robodoc hip-revision procedure. Acta Orthop Scand 72:595–599CrossRefPubMed Nogler M, Krismer M, Haid C, Ogon M, Bach C, Wimmer C (2001) Excessive heat generation during cutting of cement in the Robodoc hip-revision procedure. Acta Orthop Scand 72:595–599CrossRefPubMed
7.
Zurück zum Zitat Viceconti M, Testi D, Simeoni M, Zannoni C (2003) An automated method to position prosthetic components within multiple anatomical spaces. Comput Methods Programs Biomed 70:121–127CrossRefPubMed Viceconti M, Testi D, Simeoni M, Zannoni C (2003) An automated method to position prosthetic components within multiple anatomical spaces. Comput Methods Programs Biomed 70:121–127CrossRefPubMed
8.
Zurück zum Zitat Kepple TM, Sommer HJ 3rd, Lohmann Siegel K, Stanhope SJ (1998) A three-dimensional musculoskeletal database for the lower extremities. J Biomech 31:77–80CrossRefPubMed Kepple TM, Sommer HJ 3rd, Lohmann Siegel K, Stanhope SJ (1998) A three-dimensional musculoskeletal database for the lower extremities. J Biomech 31:77–80CrossRefPubMed
9.
Zurück zum Zitat Delp SL, Komattu AV, Wixson RL (1994) Superior displacement of the hip in total joint replacement: effects of prosthetic neck length, neck-stem angle, and anteversion angle on the moment-generating capacity of the muscles. J Orthop Res 12:860–870PubMed Delp SL, Komattu AV, Wixson RL (1994) Superior displacement of the hip in total joint replacement: effects of prosthetic neck length, neck-stem angle, and anteversion angle on the moment-generating capacity of the muscles. J Orthop Res 12:860–870PubMed
10.
Zurück zum Zitat Vasavada AN, Delp SL, Maloney WJ, Schurman DJ, Zajac FE (1994) Compensating for changes in muscle length in total hip arthroplasty. Effects on the moment generating capacity of the muscles. Clin Orthop 302:121–133PubMed Vasavada AN, Delp SL, Maloney WJ, Schurman DJ, Zajac FE (1994) Compensating for changes in muscle length in total hip arthroplasty. Effects on the moment generating capacity of the muscles. Clin Orthop 302:121–133PubMed
11.
Zurück zum Zitat McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME (1995) Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg Br 77:865–869PubMed McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME (1995) Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg Br 77:865–869PubMed
12.
Zurück zum Zitat Jerosch J, Steinbeck J, Stechmann J, Guth V (1997) Influence of a high hip centre on abductor muscle function. Arch Orthop Trauma Surg 116:385–389CrossRefPubMed Jerosch J, Steinbeck J, Stechmann J, Guth V (1997) Influence of a high hip centre on abductor muscle function. Arch Orthop Trauma Surg 116:385–389CrossRefPubMed
13.
Zurück zum Zitat Edwards BN, Tullos HS, Noble PC (1987) Contributory factors and etiology of sciatic nerve palsy in total hip arthroplasty. Clin Orthop 136–141 Edwards BN, Tullos HS, Noble PC (1987) Contributory factors and etiology of sciatic nerve palsy in total hip arthroplasty. Clin Orthop 136–141
14.
Zurück zum Zitat Dhillon MS, Nagi ON (1992) Sciatic nerve palsy associated with total hip arthroplasty. Ital J Orthop Traumatol 18:521–526PubMed Dhillon MS, Nagi ON (1992) Sciatic nerve palsy associated with total hip arthroplasty. Ital J Orthop Traumatol 18:521–526PubMed
15.
Zurück zum Zitat Friden J, Lieber RL (2002) Mechanical considerations in the design of surgical reconstructive procedures. J Biomech 35:1039–1045CrossRefPubMed Friden J, Lieber RL (2002) Mechanical considerations in the design of surgical reconstructive procedures. J Biomech 35:1039–1045CrossRefPubMed
16.
Zurück zum Zitat Lieber RL, Friden J (1997) Intraoperative measurement and biomechanical modeling of the flexor carpi ulnaris-to-extensor carpi radialis longus tendon transfer. J Biomech Eng 119:386–391PubMed Lieber RL, Friden J (1997) Intraoperative measurement and biomechanical modeling of the flexor carpi ulnaris-to-extensor carpi radialis longus tendon transfer. J Biomech Eng 119:386–391PubMed
17.
Zurück zum Zitat Lieber RL (1999) Skeletal muscle is a biological example of a linear electro-active actuator. Proceedings of the SPIE 6th Annual International Symposium on Smart Structures and Materials, San Diego, pp 3669–4003 Lieber RL (1999) Skeletal muscle is a biological example of a linear electro-active actuator. Proceedings of the SPIE 6th Annual International Symposium on Smart Structures and Materials, San Diego, pp 3669–4003
18.
Zurück zum Zitat Maganaris CN (2001) Force-length characteristics of in vivo human skeletal muscle. Acta Physiol Scand 172:279–285CrossRefPubMed Maganaris CN (2001) Force-length characteristics of in vivo human skeletal muscle. Acta Physiol Scand 172:279–285CrossRefPubMed
Metadaten
Titel
New aspects and approaches in pre-operative planning of hip reconstruction: a computer simulation
verfasst von
Marco Viceconti
Alessandro Chiarini
Debora Testi
Fulvia Taddei
Barbara Bordini
Francesco Traina
Aldo Toni
Publikationsdatum
01.10.2004
Verlag
Springer-Verlag
Erschienen in
Langenbeck's Archives of Surgery / Ausgabe 5/2004
Print ISSN: 1435-2443
Elektronische ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-003-0446-7

Weitere Artikel der Ausgabe 5/2004

Langenbeck's Archives of Surgery 5/2004 Zur Ausgabe

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.