Skip to main content
Erschienen in: Acta Neurochirurgica 12/2009

01.12.2009 | Technical Note

Universal Clamp system in thoracolumbar spinal fixation: technical note

verfasst von: Roberto Gazzeri, Andrea Faiola, Marcelo Galarza, Marco Tamorri

Erschienen in: Acta Neurochirurgica | Ausgabe 12/2009

Einloggen, um Zugang zu erhalten

Abstract

Background

The Universal Clamp is a polyester band passed under the lamina and connected to a rod by a titanium clamp that has been recently reported as an alternative for replacing screws and hooks for thoracolumbar spinal diseases. To date, there is no report of an evaluation of the effectiveness and safety of posterior fixation and fusion using this technique.

Methods

This study was a prospective evaluation of a cohort of 18 patients with thoracolumbar disorders that were surgically treated between November 2006 and June 2007 with Universal Clamps for spinal fixation. Fifteen cases were traumatic fractures with others two with degenerative severe stenosis and one kyphotic stenosis. Levels treated were thoracolumbar in 15 cases, thoracic in two cases, and lumbar in one case. Seventeen patients underwent correction and instrumentation using a hybrid construct of screws and clamps, while one patient underwent fixation using Universal Clamps only. Intraoperative evoked potentials were monitored in all cases. One patient had infection that resolved after antibiotic therapy without implant removal. No neurological adverse event was seen. There was no rod breakage or clamp loosening during a follow-up of 12 months.

Conclusions

The polyester band is soft and flexible, and the anterior-posterior spinal canal space occupied by the band is less than by sublaminar wire steel cable, thus avoiding direct spinal cord trauma during sublaminar passage. The flat configuration of the cable distributes the load over a larger contact area under the lamina compared to metal wires without producing imaging artefacts in postoperative imaging. This preliminary report demonstrates the efficacy and safety of this technique for the stabilization of thoracolumbar spinal disorders.
Literatur
1.
Zurück zum Zitat Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 1;25(5):606–614CrossRef Amiot LP, Lang K, Putzier M, Zippel H, Labelle H (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 1;25(5):606–614CrossRef
2.
Zurück zum Zitat American Spinal Injury Association (1984) Standards for neurological classification for spinal injury patients. ASIA, Chicago American Spinal Injury Association (1984) Standards for neurological classification for spinal injury patients. ASIA, Chicago
3.
Zurück zum Zitat Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr (2001) In vivo accuracy of thoracic pedicle screws. Spine 1;26(21):2340–2346CrossRef Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr (2001) In vivo accuracy of thoracic pedicle screws. Spine 1;26(21):2340–2346CrossRef
4.
Zurück zum Zitat Ben-David B (1988) Spinal cord monitoring. Orthop Clinics North Am 19:427–448 Ben-David B (1988) Spinal cord monitoring. Orthop Clinics North Am 19:427–448
5.
Zurück zum Zitat Brown CA, Lenke LG, Bridwell KH, Geideman WM, Hasan SA, Blanke K (1998) Complications of pedicle thoracolumbar and lumbar pedicle screws. Spine 23:1566–1571CrossRefPubMed Brown CA, Lenke LG, Bridwell KH, Geideman WM, Hasan SA, Blanke K (1998) Complications of pedicle thoracolumbar and lumbar pedicle screws. Spine 23:1566–1571CrossRefPubMed
6.
Zurück zum Zitat Carbone JJ, Tortolani PJ, Quartararo LG (2003) Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications. Spine 1;28(1):91–97CrossRef Carbone JJ, Tortolani PJ, Quartararo LG (2003) Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications. Spine 1;28(1):91–97CrossRef
7.
Zurück zum Zitat Carlioz H, Quaknine M (1994) Neurologic complications of surgery of the spine in children. Chirurgie 120:26–30PubMed Carlioz H, Quaknine M (1994) Neurologic complications of surgery of the spine in children. Chirurgie 120:26–30PubMed
8.
Zurück zum Zitat Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1553–1557CrossRefPubMed Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1553–1557CrossRefPubMed
9.
Zurück zum Zitat Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231–2239PubMedCrossRef Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231–2239PubMedCrossRef
10.
Zurück zum Zitat Dickman CA, Papadopoulos SM, Crawford NR, Brantley AG, Gealer RL (1997) Comparative mechanical properties of spinal cable and wire fixation systems. Spine 1522(6):596–604CrossRef Dickman CA, Papadopoulos SM, Crawford NR, Brantley AG, Gealer RL (1997) Comparative mechanical properties of spinal cable and wire fixation systems. Spine 1522(6):596–604CrossRef
11.
12.
Zurück zum Zitat Geremia GK, Kim KS, Cerullo L, Calenoff L (1985) Complications of sublaminar wiring. Surg Neurol 23(6):629–635CrossRefPubMed Geremia GK, Kim KS, Cerullo L, Calenoff L (1985) Complications of sublaminar wiring. Surg Neurol 23(6):629–635CrossRefPubMed
13.
Zurück zum Zitat Grobler LJ, Gaines RW, Kempff PG (1997) Comparing Mersilene tape and stainless steel wire as sublaminar spinal fixation in the Chagma baboon (Papio ursinus). Iowa Orthop J 17:20–31PubMed Grobler LJ, Gaines RW, Kempff PG (1997) Comparing Mersilene tape and stainless steel wire as sublaminar spinal fixation in the Chagma baboon (Papio ursinus). Iowa Orthop J 17:20–31PubMed
14.
Zurück zum Zitat Gunnarsson T, Krassioukov AV, Sarjeant R, Fehlings MG (2004) Real-time continuous intraoperative electromyographic and somatosensory evoked potential recordings in spinal surgery: correlation of clinical and electrophysiologic findings in a prospective, consecutive series of 213 cases. Spine 15;29(6):677–684CrossRef Gunnarsson T, Krassioukov AV, Sarjeant R, Fehlings MG (2004) Real-time continuous intraoperative electromyographic and somatosensory evoked potential recordings in spinal surgery: correlation of clinical and electrophysiologic findings in a prospective, consecutive series of 213 cases. Spine 15;29(6):677–684CrossRef
15.
Zurück zum Zitat Harrell RM, Tong J, Weinhold PS, Dahners LE (2003) Comparison of the mechanical properties of different tension band materials and suture techniques. J Orthop Trauma 17(2):119–122CrossRefPubMed Harrell RM, Tong J, Weinhold PS, Dahners LE (2003) Comparison of the mechanical properties of different tension band materials and suture techniques. J Orthop Trauma 17(2):119–122CrossRefPubMed
16.
Zurück zum Zitat Heini P, Scholl E, Wyler D, Eggli S (1998) Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report. Spine 23:2226–2230CrossRefPubMed Heini P, Scholl E, Wyler D, Eggli S (1998) Fatal cardiac tamponade associated with posterior spinal instrumentation. A case report. Spine 23:2226–2230CrossRefPubMed
17.
Zurück zum Zitat Ilharreborde B, Hongo M, Gay RE, An KN, Mazda K (2007) Universal Clamp: A new method of fixation compared to pedicle screw in human lumbar vertebra. ISSLS Meeting, Hong Kong Ilharreborde B, Hongo M, Gay RE, An KN, Mazda K (2007) Universal Clamp: A new method of fixation compared to pedicle screw in human lumbar vertebra. ISSLS Meeting, Hong Kong
18.
Zurück zum Zitat Johnston CE 2nd, Happel LT Jr, Norris R, Burke SW, King AG, Roberts JM (1986) Delayed paraplegia complicating segmental spinal instrumentation. J Bone Joint Surg [Am] 68:556–563 Johnston CE 2nd, Happel LT Jr, Norris R, Burke SW, King AG, Roberts JM (1986) Delayed paraplegia complicating segmental spinal instrumentation. J Bone Joint Surg [Am] 68:556–563
19.
Zurück zum Zitat Kim KD, Patrick Johnson J, Bloch BS O, Masciopinto JE (2001) Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine 15;26(4):360–364CrossRef Kim KD, Patrick Johnson J, Bloch BS O, Masciopinto JE (2001) Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine 15;26(4):360–364CrossRef
20.
Zurück zum Zitat Krag MH, Beynnon BD, Pope MH, Frymoyer JW, Haugh LD, Weaver DL (1986) An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing. Clin Orthop Relat Res 203:75–98PubMed Krag MH, Beynnon BD, Pope MH, Frymoyer JW, Haugh LD, Weaver DL (1986) An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing. Clin Orthop Relat Res 203:75–98PubMed
21.
Zurück zum Zitat Krag MH, Weaver DL, Beynonn BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13(1):27–32CrossRefPubMed Krag MH, Weaver DL, Beynonn BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13(1):27–32CrossRefPubMed
22.
Zurück zum Zitat Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed Lonstein JE, Denis F, Perra JH, Pinto MR, Smith MD, Winter RB (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528PubMed
23.
Zurück zum Zitat Lowe T (1987) Morbidity and Mortality Committee Report. Annual Meeting of the Scoliosis Research Society, Vancouver, British Columbia, Canada Lowe T (1987) Morbidity and Mortality Committee Report. Annual Meeting of the Scoliosis Research Society, Vancouver, British Columbia, Canada
24.
Zurück zum Zitat Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 163:192–198PubMed Luque ER (1982) Segmental spinal instrumentation for correction of scoliosis. Clin Orthop Relat Res 163:192–198PubMed
25.
Zurück zum Zitat MacEwen GD, Bunnell WP, Sriram K (1975) Acute neurological complications in the treatment of scoliosis. A report of the Scoliosis Research Society. J Bone Joint Surg Am 57:404–408PubMed MacEwen GD, Bunnell WP, Sriram K (1975) Acute neurological complications in the treatment of scoliosis. A report of the Scoliosis Research Society. J Bone Joint Surg Am 57:404–408PubMed
26.
Zurück zum Zitat Masferrer R, Gomez CH, Karahalios DG, Sonntag VK (1998) Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: a 5-year review. J Neurosurg 89:371–377CrossRefPubMed Masferrer R, Gomez CH, Karahalios DG, Sonntag VK (1998) Efficacy of pedicle screw fixation in the treatment of spinal instability and failed back surgery: a 5-year review. J Neurosurg 89:371–377CrossRefPubMed
27.
Zurück zum Zitat Mazda K, Ilharreborde B, Even J, Lefevre Y, Fitoussi F, Penneçot GF (2009) Efficacy and safety of posteromedial translation for correction of thoracic curves in adolescent idiopathic scoliosis using a new connection to the spine: the Universal Clamp. Eur Spine J 18:158–169CrossRefPubMed Mazda K, Ilharreborde B, Even J, Lefevre Y, Fitoussi F, Penneçot GF (2009) Efficacy and safety of posteromedial translation for correction of thoracic curves in adolescent idiopathic scoliosis using a new connection to the spine: the Universal Clamp. Eur Spine J 18:158–169CrossRefPubMed
28.
Zurück zum Zitat Minor ME, Morrissey NJ, Peress R, Carroccio A, Ellozy S, Agarwal G, Teodorescu V, Hollier LH, Marin ML (2004) Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg 39(4):893–896CrossRefPubMed Minor ME, Morrissey NJ, Peress R, Carroccio A, Ellozy S, Agarwal G, Teodorescu V, Hollier LH, Marin ML (2004) Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg 39(4):893–896CrossRefPubMed
29.
Zurück zum Zitat Morgenstern W, Ferguson SJ, Berey S, Orr TE, Nolte LP (2003) Posterior thoracic extrapedicular fixation: a biomechanical study. Spine 15;28(16):1829–1835CrossRef Morgenstern W, Ferguson SJ, Berey S, Orr TE, Nolte LP (2003) Posterior thoracic extrapedicular fixation: a biomechanical study. Spine 15;28(16):1829–1835CrossRef
30.
Zurück zum Zitat Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156–159CrossRefPubMed Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156–159CrossRefPubMed
31.
Zurück zum Zitat Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA (2001) Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Joint Surg Br 83(7):1009–1014CrossRefPubMed Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA (2001) Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Joint Surg Br 83(7):1009–1014CrossRefPubMed
32.
Zurück zum Zitat Schrader WC, Bethem D, Scerbin V (1988) The chronic local effects of sublaminar wires. An animal model. Spine 13(5):499–502CrossRefPubMed Schrader WC, Bethem D, Scerbin V (1988) The chronic local effects of sublaminar wires. An animal model. Spine 13(5):499–502CrossRefPubMed
33.
Zurück zum Zitat Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed Vaccaro AR, Rizzolo SJ, Allardyce TJ, Ramsey M, Salvo J, Balderston RA (1995) Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J Bone Joint Surg Am 77:1193–1199PubMed
34.
Zurück zum Zitat West JL, Ogilvie JW, Bradford DS (1991) Complications of variable screw plate pedicle screw fixation. Spine 16:577–579CrossRef West JL, Ogilvie JW, Bradford DS (1991) Complications of variable screw plate pedicle screw fixation. Spine 16:577–579CrossRef
35.
Zurück zum Zitat Zindrick MR, Knight GW, Bunch WH, Miller MC, Butler DM, Lorenz M, Behal R (1989) Factors influencing the penetration of wires into the neural canal during segmental wiring. J Bone Joint Surg Am 71(5):742–750PubMed Zindrick MR, Knight GW, Bunch WH, Miller MC, Butler DM, Lorenz M, Behal R (1989) Factors influencing the penetration of wires into the neural canal during segmental wiring. J Bone Joint Surg Am 71(5):742–750PubMed
Metadaten
Titel
Universal Clamp system in thoracolumbar spinal fixation: technical note
verfasst von
Roberto Gazzeri
Andrea Faiola
Marcelo Galarza
Marco Tamorri
Publikationsdatum
01.12.2009
Verlag
Springer Vienna
Erschienen in
Acta Neurochirurgica / Ausgabe 12/2009
Print ISSN: 0001-6268
Elektronische ISSN: 0942-0940
DOI
https://doi.org/10.1007/s00701-009-0495-y

Weitere Artikel der Ausgabe 12/2009

Acta Neurochirurgica 12/2009 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Nicht Creutzfeldt Jakob, sondern Abführtee-Vergiftung

29.05.2024 Hyponatriämie Nachrichten

Eine ältere Frau trinkt regelmäßig Sennesblättertee gegen ihre Verstopfung. Der scheint plötzlich gut zu wirken. Auf Durchfall und Erbrechen folgt allerdings eine Hyponatriämie. Nach deren Korrektur kommt es plötzlich zu progredienten Kognitions- und Verhaltensstörungen.

Schutz der Synapsen bei Alzheimer

29.05.2024 Morbus Alzheimer Nachrichten

Mit einem Neurotrophin-Rezeptor-Modulator lässt sich möglicherweise eine bestehende Alzheimerdemenz etwas abschwächen: Erste Phase-2-Daten deuten auf einen verbesserten Synapsenschutz.

Sozialer Aufstieg verringert Demenzgefahr

24.05.2024 Demenz Nachrichten

Ein hohes soziales Niveau ist mit die beste Versicherung gegen eine Demenz. Noch geringer ist das Demenzrisiko für Menschen, die sozial aufsteigen: Sie gewinnen fast zwei demenzfreie Lebensjahre. Umgekehrt steigt die Demenzgefahr beim sozialen Abstieg.

Hirnblutung unter DOAK und VKA ähnlich bedrohlich

17.05.2024 Direkte orale Antikoagulanzien Nachrichten

Kommt es zu einer nichttraumatischen Hirnblutung, spielt es keine große Rolle, ob die Betroffenen zuvor direkt wirksame orale Antikoagulanzien oder Marcumar bekommen haben: Die Prognose ist ähnlich schlecht.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.