Skip to main content
Erschienen in: Journal of Hand and Microsurgery 1/2015

01.06.2015 | Original Article

Functional Outcome and Complications at 2.5 Years Following Volar Locking Plate Fixation of Distal Radius Fractures

verfasst von: Robert J. MacFarlane, David Miller, Lynn Wilson, Carl Meyer, Cronan Kerin, David James Ford, Graham Cheung

Erschienen in: Journal of Hand and Microsurgery | Ausgabe 1/2015

Einloggen, um Zugang zu erhalten

Abstract

Distal radius fractures are increasingly treated by internal fixation, but there have been relatively few studies relating to functional outcome at 12 months or more. The aim of this study was to ascertain the patient reported function of the wrist at a minimum of 12 months following fixation of a distal radius fracture, the time taken to return to work, and the complication rate. We conducted a retrospective review of 187 consecutive patients treated by a specialist hand and wrist trauma team at a tertiary referral unit over a 5 year period. Mean age was 57.3 years (range 16–93). Median time to surgery was 4 days (interquartile range 2–9). Median follow up was 31 months (interquartile range 23–41 months). The median PRWE score was 3; (range 0–83). There was no difference in outcome in patients who had surgery delayed by greater than 2 weeks (p > 0.05). The median time to return to work was 5 weeks (interquartile range 1–8 weeks). There were 15 complications (8 %) including 3 tendon injuries. We have demonstrated an early return to work in patients who were employed, a low complication rate, and highly favourable functional outcomes at a mean of 30 months postoperatively. We recommend the use of the DVR plate and involvement of a dedicated hand and wrist trauma team for treatment of unstable fractures of the distal radius.
Literatur
1.
Zurück zum Zitat Court-Brown CM, Caesar B (2006) Epidemiology of adult fractures: a review. Injury 37:691–697PubMedCrossRef Court-Brown CM, Caesar B (2006) Epidemiology of adult fractures: a review. Injury 37:691–697PubMedCrossRef
2.
Zurück zum Zitat Handoll HH, Vaghela MV, Madhok R (2007) Percutaneous pinning for treating distal radial fractures in adults. Cochrane Database Syst Rev 18:CD006080 Handoll HH, Vaghela MV, Madhok R (2007) Percutaneous pinning for treating distal radial fractures in adults. Cochrane Database Syst Rev 18:CD006080
3.
Zurück zum Zitat Cui Z, Yu B, Hu Y, Lin Q, Wang B (2012) Dynamic versus static external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Injury 43:1006–1013PubMedCrossRef Cui Z, Yu B, Hu Y, Lin Q, Wang B (2012) Dynamic versus static external fixation for unstable distal radius fractures: an up-to-date meta-analysis. Injury 43:1006–1013PubMedCrossRef
4.
Zurück zum Zitat McQueen MM (2005) Non-spanning external fixation of the distal radius. Hand Clin 21:375–380PubMedCrossRef McQueen MM (2005) Non-spanning external fixation of the distal radius. Hand Clin 21:375–380PubMedCrossRef
5.
Zurück zum Zitat Hayes AJ, Duffy PJ, McQueen MM (2008) Bridging and non-bridging external fixation in the treatment of unstable fractures of the distal radius: a retrospective study of 588 patients. Acta Orthop 79:540–547PubMedCrossRef Hayes AJ, Duffy PJ, McQueen MM (2008) Bridging and non-bridging external fixation in the treatment of unstable fractures of the distal radius: a retrospective study of 588 patients. Acta Orthop 79:540–547PubMedCrossRef
6.
Zurück zum Zitat Figl M, Weninger P, Liska M, Hofbauer M, Leixnering M (2009) Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results. Arch Orthop Trauma Surg 129:661–669PubMedCrossRef Figl M, Weninger P, Liska M, Hofbauer M, Leixnering M (2009) Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results. Arch Orthop Trauma Surg 129:661–669PubMedCrossRef
7.
Zurück zum Zitat Osada D, Kamei S, Masuzaki K, Takai M, Kameda M, Tamai K (2008) Prospective study of distal radius fractures treated with a volar locking plate system. J Hand Surg [Am] 33:691–700CrossRef Osada D, Kamei S, Masuzaki K, Takai M, Kameda M, Tamai K (2008) Prospective study of distal radius fractures treated with a volar locking plate system. J Hand Surg [Am] 33:691–700CrossRef
8.
Zurück zum Zitat Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg [Am] 31:359–365CrossRef Rozental TD, Blazar PE (2006) Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg [Am] 31:359–365CrossRef
9.
Zurück zum Zitat Rozental TD, Blazar PE, Franko OI, Chacko AT, Earp BE, Day CS (2009) Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am 91:1837–1846PubMedCrossRef Rozental TD, Blazar PE, Franko OI, Chacko AT, Earp BE, Day CS (2009) Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Joint Surg Am 91:1837–1846PubMedCrossRef
10.
Zurück zum Zitat Grewal R, MacDermaid JC, King GJ, Faber KJ (2011) Open reduction and internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand Surg [Am] 36:1899–1906CrossRef Grewal R, MacDermaid JC, King GJ, Faber KJ (2011) Open reduction and internal fixation versus percutaneous pinning with external fixation of distal radius fractures: a prospective, randomized clinical trial. J Hand Surg [Am] 36:1899–1906CrossRef
11.
Zurück zum Zitat Dahl WJ, Nassab PF, Burgess KM, Postak PD, Evans PJ, Seitz WH, Greenwald AS, Lawton JN (2012) Biomechanical properties of fixed-angle volar distal radius plates under dynamic loading. J Hand Surg [Am] 37:1381–1387CrossRef Dahl WJ, Nassab PF, Burgess KM, Postak PD, Evans PJ, Seitz WH, Greenwald AS, Lawton JN (2012) Biomechanical properties of fixed-angle volar distal radius plates under dynamic loading. J Hand Surg [Am] 37:1381–1387CrossRef
12.
Zurück zum Zitat Klos K, Rausch S, Loffler M, Frober R, Hofmeier K, Lenz M, Hofmann GO, Muckley T (2010) A biomechanical comparison of a biodegradable volar locked plate with two titanium volar locked plates in a distal radius fracture model. J Trauma 68:984–991PubMed Klos K, Rausch S, Loffler M, Frober R, Hofmeier K, Lenz M, Hofmann GO, Muckley T (2010) A biomechanical comparison of a biodegradable volar locked plate with two titanium volar locked plates in a distal radius fracture model. J Trauma 68:984–991PubMed
13.
Zurück zum Zitat Sobky K, Baldini T, Thomas K, Bach J et al (2007) Biomechanical comparison of different volar fracture fixation plates for distal radius fractures. Hand 3:96–101PubMedCentralPubMedCrossRef Sobky K, Baldini T, Thomas K, Bach J et al (2007) Biomechanical comparison of different volar fracture fixation plates for distal radius fractures. Hand 3:96–101PubMedCentralPubMedCrossRef
14.
Zurück zum Zitat Strauss EJ, Banerjee D, Kummer FJ, Tejwani NC (2008) Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate. J Trauma 64:975–981PubMedCrossRef Strauss EJ, Banerjee D, Kummer FJ, Tejwani NC (2008) Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: biomechanical comparison with a volar locking plate. J Trauma 64:975–981PubMedCrossRef
15.
Zurück zum Zitat Orbay JL, Badia A, Indriago IR, Infante A et al (2005) The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Upper Extrem Surg 5:204–211CrossRef Orbay JL, Badia A, Indriago IR, Infante A et al (2005) The extended flexor carpi radialis approach: a new perspective for the distal radius fracture. Tech Hand Upper Extrem Surg 5:204–211CrossRef
16.
Zurück zum Zitat Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg [Am] 27:205–215CrossRef Orbay JL, Fernandez DL (2002) Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg [Am] 27:205–215CrossRef
17.
Zurück zum Zitat Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg [Am] 29:96–102CrossRef Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg [Am] 29:96–102CrossRef
18.
Zurück zum Zitat Ibrahim I, Alsey K, Naqui SZ, Pendlebury G, Warner J (2012) Short term outcomes following distal volar radial (DVR) plating of distal radius fractures. J Bone Joint Surg Br 94; SUPPIV: 142 Ibrahim I, Alsey K, Naqui SZ, Pendlebury G, Warner J (2012) Short term outcomes following distal volar radial (DVR) plating of distal radius fractures. J Bone Joint Surg Br 94; SUPPIV: 142
19.
Zurück zum Zitat Lazano-Calderon SA, Souer S, Mudgal C, Jupiter J, Ring D (2008) Wrist mobilization following volar plate fixation of fractures of the distal part of the radius. J Bone Joint Surg Am 90:1297–1304CrossRef Lazano-Calderon SA, Souer S, Mudgal C, Jupiter J, Ring D (2008) Wrist mobilization following volar plate fixation of fractures of the distal part of the radius. J Bone Joint Surg Am 90:1297–1304CrossRef
20.
Zurück zum Zitat Tarallo L, Adani R, Mugnai R, Catani F (2011) The treatment of distal radius articular fractures of C1-C2 type with DVR plate: analysis of 40 cases. Musculoskelet Surg 95:225–230PubMedCrossRef Tarallo L, Adani R, Mugnai R, Catani F (2011) The treatment of distal radius articular fractures of C1-C2 type with DVR plate: analysis of 40 cases. Musculoskelet Surg 95:225–230PubMedCrossRef
21.
Zurück zum Zitat Marcheix PS, Dotzis A, Benko PE, Siegler J, Arnaud JP, Charissoux JL (2010) Extension fractures of the distal radius in patients older than 50: a prospective randomized study comparing fixation using mixed pins or a palmar fixed-angle plate. J Hand Surg Eur 35:646–651CrossRef Marcheix PS, Dotzis A, Benko PE, Siegler J, Arnaud JP, Charissoux JL (2010) Extension fractures of the distal radius in patients older than 50: a prospective randomized study comparing fixation using mixed pins or a palmar fixed-angle plate. J Hand Surg Eur 35:646–651CrossRef
22.
Zurück zum Zitat Pino S, Bonilla JC, BOrras JE, Punet E, Vila J, Hernandez JA (2011) Comparative study of distal radius fracture treated with volar plate or external fixation. J Bone Joint Surg Br 93; SUPPII: 169 Pino S, Bonilla JC, BOrras JE, Punet E, Vila J, Hernandez JA (2011) Comparative study of distal radius fracture treated with volar plate or external fixation. J Bone Joint Surg Br 93; SUPPII: 169
23.
Zurück zum Zitat Wilcke M, Abbaszadegan H, Adolphson P (2011) Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year. Acta Orthop 82:76–81PubMedCentralPubMedCrossRef Wilcke M, Abbaszadegan H, Adolphson P (2011) Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year. Acta Orthop 82:76–81PubMedCentralPubMedCrossRef
24.
Zurück zum Zitat Arora R, Lutz M, Deml C, Krappinger D et al (2011) A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am 93:2146–2153PubMed Arora R, Lutz M, Deml C, Krappinger D et al (2011) A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J Bone Joint Surg Am 93:2146–2153PubMed
25.
Zurück zum Zitat Bentohami A, de Burlet K, de Korte N, van den Bekerom MP, Goslings JC, Schep NW (2013) Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur Bentohami A, de Burlet K, de Korte N, van den Bekerom MP, Goslings JC, Schep NW (2013) Complications following volar locking plate fixation for distal radial fractures: a systematic review. J Hand Surg Eur
26.
Zurück zum Zitat Valbuena SE, Cogswell LK, Baraziol R, Vealenti P (2010) Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases. Chir Main 29:109–113PubMedCrossRef Valbuena SE, Cogswell LK, Baraziol R, Vealenti P (2010) Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases. Chir Main 29:109–113PubMedCrossRef
27.
Zurück zum Zitat Casaletto JA, Machin D, Leung R, Brown DJ (2009) Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur 34:471–474CrossRef Casaletto JA, Machin D, Leung R, Brown DJ (2009) Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur 34:471–474CrossRef
28.
Zurück zum Zitat Imatani J, Akita K, Yamaguchi K, Shimizu H, Kondou H, Ozaki T (2012) An anatomical study of the watershed line on the volar distal aspect of the radius: implications for plate placement and avoidance of tendon ruptures. J Hand Surg [Am] 37:1550–1554CrossRef Imatani J, Akita K, Yamaguchi K, Shimizu H, Kondou H, Ozaki T (2012) An anatomical study of the watershed line on the volar distal aspect of the radius: implications for plate placement and avoidance of tendon ruptures. J Hand Surg [Am] 37:1550–1554CrossRef
29.
Zurück zum Zitat Matityahu AM, Lapalme SN, Seth A, Marmor MT, Buckley JM, Lattanza LL (2013) How placement affects force and contact pressure between a volar plate of the distal radius and the flexor pollicis longus tendon: a biomechanical investigation. J Hand Surg Eur 38:144–150CrossRef Matityahu AM, Lapalme SN, Seth A, Marmor MT, Buckley JM, Lattanza LL (2013) How placement affects force and contact pressure between a volar plate of the distal radius and the flexor pollicis longus tendon: a biomechanical investigation. J Hand Surg Eur 38:144–150CrossRef
30.
Zurück zum Zitat Soong M, van Leerdam R, Guitton TG, Got C, Katarincic J, Ring D (2011) Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg [Am] 36:3–9CrossRef Soong M, van Leerdam R, Guitton TG, Got C, Katarincic J, Ring D (2011) Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg [Am] 36:3–9CrossRef
31.
Zurück zum Zitat Al-Rashid M, Theivandran K, Craigen MAC (2006) Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radius fractures. J Bone Joint Surg (Br) 88:1610–1612CrossRef Al-Rashid M, Theivandran K, Craigen MAC (2006) Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radius fractures. J Bone Joint Surg (Br) 88:1610–1612CrossRef
32.
Zurück zum Zitat Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabi M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322PubMedCrossRef Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabi M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322PubMedCrossRef
33.
Zurück zum Zitat Benson EC, DeCarvalho A, Mikola EA, Veith JM, Moneim MS (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218–222PubMedCrossRef Benson EC, DeCarvalho A, Mikola EA, Veith JM, Moneim MS (2006) Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res 451:218–222PubMedCrossRef
34.
Zurück zum Zitat Falla JM, Koniuch MP, Moed BR (1993) Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases. J Hand Surg [Am] 18:648–651CrossRef Falla JM, Koniuch MP, Moed BR (1993) Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases. J Hand Surg [Am] 18:648–651CrossRef
35.
Zurück zum Zitat Perry DC, Machin DM, Casaletto JA, Brown DJ (2011) Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: a cadaveric study. Ann R Coll Surg Engl 93:57–60PubMedCentralPubMedCrossRef Perry DC, Machin DM, Casaletto JA, Brown DJ (2011) Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: a cadaveric study. Ann R Coll Surg Engl 93:57–60PubMedCentralPubMedCrossRef
36.
Zurück zum Zitat Roth KM, Blazar PE, Earp BE, Han R, Leung A (2012) Incidence of extensor pollicis longus tendon rupture after nondisplaced distal radius fractures. J Hand Surg [Am] 37:942–947CrossRef Roth KM, Blazar PE, Earp BE, Han R, Leung A (2012) Incidence of extensor pollicis longus tendon rupture after nondisplaced distal radius fractures. J Hand Surg [Am] 37:942–947CrossRef
Metadaten
Titel
Functional Outcome and Complications at 2.5 Years Following Volar Locking Plate Fixation of Distal Radius Fractures
verfasst von
Robert J. MacFarlane
David Miller
Lynn Wilson
Carl Meyer
Cronan Kerin
David James Ford
Graham Cheung
Publikationsdatum
01.06.2015
Verlag
Springer India
Erschienen in
Journal of Hand and Microsurgery / Ausgabe 1/2015
Print ISSN: 0974-3227
Elektronische ISSN: 0974-6897
DOI
https://doi.org/10.1007/s12593-014-0155-1

Weitere Artikel der Ausgabe 1/2015

Journal of Hand and Microsurgery 1/2015 Zur Ausgabe

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.