Skip to main content
Erschienen in: Intensive Care Medicine 7/2007

01.07.2007 | Brief Report

Reproducibility of bladder pressure measurements in critically ill patients

verfasst von: Edward J. Kimball, Mary C. Mone, Timothy R. Wolfe, Gabriele K. Baraghoshi, Stephen C. Alder

Erschienen in: Intensive Care Medicine | Ausgabe 7/2007

Einloggen, um Zugang zu erhalten

Abstract

Objective

Intra-abdominal hypertension is an independent cause of multiorgan failure and directly effects other physiological measurements, making it an important factor in the management of critically ill patients, but no clinical studies have investigated the reproducibility of intra-abdominal pressure (IAP) measurement to ensure diagnostic accuracy. This study evaluated the intraobserver and interobserver variability of bladder pressure measurements.

Design and setting

Prospective, observational study in a university-based adult surgical intensive care unit.

Patients

Critically ill patients undergoing intra-abdominal pressure readings, measured by nursing staff.

Measurements and results

The study compared patient IAP measurements obtained by the same nurse (intraobserver variation) and between two different nurses (interobserver variation) in critical care patients with clinical indications for IAP monitoring. Data related to the nursing technique and performance were observed and collected for each IAP measurement obtained. Good correlation of bladder pressure measurements between the same and different individuals was found. Intraobserver and interobserver Pearson's correlations for measured IAP were 0.934 and 0.950, respectively. A unit protocol for IAP measurement standardization was modified based on observational data collected.

Conclusions

Intra-abdominal pressure can be accurately and reliably measured in critically ill patients by utilizing a standardized measurement device combined with a standardized clinical protocol.
Literatur
2.
Zurück zum Zitat Sugrue M (2002) Intra-abdominal pressure: time for clinical practice guidelines? Intensive Care Med 28:389–391CrossRefPubMed Sugrue M (2002) Intra-abdominal pressure: time for clinical practice guidelines? Intensive Care Med 28:389–391CrossRefPubMed
3.
Zurück zum Zitat Malbrain MLNG (2004) Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensive Care Med 30:357–371CrossRefPubMed Malbrain MLNG (2004) Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensive Care Med 30:357–371CrossRefPubMed
4.
Zurück zum Zitat Wolfe TR, Kimball EJ (2005) Inter- and intra-observer variability does not occur with a new intra-abdominal pressure monitoring kit. ANZ J Surg 75:A1CrossRef Wolfe TR, Kimball EJ (2005) Inter- and intra-observer variability does not occur with a new intra-abdominal pressure monitoring kit. ANZ J Surg 75:A1CrossRef
5.
Zurück zum Zitat Zar JH (1999) Biostatistical analyses. Prentice Hall, Upper Saddle River Zar JH (1999) Biostatistical analyses. Prentice Hall, Upper Saddle River
6.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRefPubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310CrossRefPubMed
7.
Zurück zum Zitat Darovic GO, Zbilut JB (2002) Fluid filled monitoring systems. In: Darovic GO (ed) Hemodynamic monitoring: invasive and noninvasive clinical applications. Saunders, Philadelphia, pp 113–131 Darovic GO, Zbilut JB (2002) Fluid filled monitoring systems. In: Darovic GO (ed) Hemodynamic monitoring: invasive and noninvasive clinical applications. Saunders, Philadelphia, pp 113–131
8.
Zurück zum Zitat DePotter TJ, Dits H, Malbrain MLNG (2005) Intra- and interobserver variability during in vitro validation of two novel methods for intra-abdominal pressure monitoring. Intensive Care Med 31:747–751CrossRef DePotter TJ, Dits H, Malbrain MLNG (2005) Intra- and interobserver variability during in vitro validation of two novel methods for intra-abdominal pressure monitoring. Intensive Care Med 31:747–751CrossRef
9.
Zurück zum Zitat Peters K, Jones F, Sugrue M, Bauman A, Parr M, Balogh Z (2005) How reliable is intra-abdominal pressure measurement in intensive care? ANZ J Surg 75:A10CrossRef Peters K, Jones F, Sugrue M, Bauman A, Parr M, Balogh Z (2005) How reliable is intra-abdominal pressure measurement in intensive care? ANZ J Surg 75:A10CrossRef
10.
Zurück zum Zitat Rizvi K, deBoisblanc BP, Truwit JD, Dhillon G, Arroliga A, Fuchs BD, Guntupalli KK, Hite D, Hayden D (2005) Effect of airway pressure display on interobserver agreement in the assessment of vascular pressures in patients with acute lung injury and acute respiratory distress syndrome. Crit Care Med 33:98–103CrossRefPubMed Rizvi K, deBoisblanc BP, Truwit JD, Dhillon G, Arroliga A, Fuchs BD, Guntupalli KK, Hite D, Hayden D (2005) Effect of airway pressure display on interobserver agreement in the assessment of vascular pressures in patients with acute lung injury and acute respiratory distress syndrome. Crit Care Med 33:98–103CrossRefPubMed
Metadaten
Titel
Reproducibility of bladder pressure measurements in critically ill patients
verfasst von
Edward J. Kimball
Mary C. Mone
Timothy R. Wolfe
Gabriele K. Baraghoshi
Stephen C. Alder
Publikationsdatum
01.07.2007
Verlag
Springer Berlin Heidelberg
Erschienen in
Intensive Care Medicine / Ausgabe 7/2007
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-007-0641-z

Weitere Artikel der Ausgabe 7/2007

Intensive Care Medicine 7/2007 Zur Ausgabe

Eingreifen von Umstehenden rettet vor Erstickungstod!

15.05.2024 Fremdkörperaspiration Nachrichten

Wer sich an einem Essensrest verschluckt und um Luft ringt, benötigt vor allem rasche Hilfe. Dass Umstehende nur in jedem zweiten Erstickungsnotfall bereit waren, diese zu leisten, ist das ernüchternde Ergebnis einer Beobachtungsstudie aus Japan. Doch es gibt auch eine gute Nachricht.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Häufigste Gründe für Brustschmerzen bei Kindern

06.05.2024 Pädiatrische Diagnostik Nachrichten

Akute Brustschmerzen sind ein Alarmsymptom par exellence, schließlich sind manche Auslöser lebensbedrohlich. Auch Kinder klagen oft über Schmerzen in der Brust. Ein Studienteam ist den Ursachen nachgegangen.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.