Abstract

In coronary CT angiography (CTA), both high-grade stenoses and total occlusions of a coronary artery may appear as a complete interruption of the contrast-enhanced lumen. Parameters to differentiate between occlusions and stenoses have not been systematically assessed. We evaluated 40 consecutive patients with a lesion demonstrating complete interruption of the contrast-enhanced lumen in coronary CTA and in whom invasive coronary angiography was available. Length of the vessel segment without luminal contrast enhancement; luminal enhancement proximal, in and distal to the lesion; degree of coronary remodelling; and the degree of lesion calcification were assessed by a blinded observer unaware of the invasive angiogram. Mean length of complete occlusions (n = 20; range 4–54 mm; mean 16.6 ± 3.5 mm) was significantly longer than for high-grade stenoses (n = 20; 2–8 mm; mean 4.6 ± 1.7 mm, p < 0.001). A lesion length ≥ 9 mm was 100% specific and 70% sensitive for an occlusion. No significant differences were found for vessel enhancement in or distal to the lesion, remodelling index or degree of calcification. Lesion length is the only parameter that may differentiate complete occlusions and high-grade stenoses in coronary CTA. For lesions ≥ 9 mm, an occlusion is very likely.
Literatur
1.
Zurück zum Zitat Achenbach S (2007) Cardiac CT: state of the art for the detection of coronary arterial stenosis. JCCT 1:3–20 Achenbach S (2007) Cardiac CT: state of the art for the detection of coronary arterial stenosis. JCCT 1:3–20
2.
Zurück zum Zitat Ferencik M, Ropers D, Abbara S et al (2007) Diagnostic accuracy of image postprocessing methods for the detection of coronary artery stenoses by using multidetector CT. Radiology 243:696–702PubMedCrossRef Ferencik M, Ropers D, Abbara S et al (2007) Diagnostic accuracy of image postprocessing methods for the detection of coronary artery stenoses by using multidetector CT. Radiology 243:696–702PubMedCrossRef
3.
Zurück zum Zitat Raff GL, Gallagher MJ, O’Neill WW et al (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef Raff GL, Gallagher MJ, O’Neill WW et al (2005) Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 46:552–557PubMedCrossRef
4.
Zurück zum Zitat Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography. A comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef Leber AW, Knez A, von Ziegler F et al (2005) Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography. A comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 46:147–154PubMedCrossRef
5.
Zurück zum Zitat Hoffmann MHK, Shi H, Schmitz BL et al (2005) Noninvasive coronary angiography with multislice computed tomography. JAMA 293:2471–2478PubMedCrossRef Hoffmann MHK, Shi H, Schmitz BL et al (2005) Noninvasive coronary angiography with multislice computed tomography. JAMA 293:2471–2478PubMedCrossRef
6.
Zurück zum Zitat Cury RC, Pomerantsev EV, Ferencik M et al (2005) Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography. Am J Cardiol 96:784–787PubMedCrossRef Cury RC, Pomerantsev EV, Ferencik M et al (2005) Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography. Am J Cardiol 96:784–787PubMedCrossRef
7.
Zurück zum Zitat Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268, Epub 2005 Dec 10PubMedCrossRef Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268, Epub 2005 Dec 10PubMedCrossRef
8.
Zurück zum Zitat Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Fortschr Röntgenstr 178:600–604CrossRef Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Fortschr Röntgenstr 178:600–604CrossRef
9.
Zurück zum Zitat Achenbach S, Ulzheimer S, Baum U et al (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed Achenbach S, Ulzheimer S, Baum U et al (2000) Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT. Circulation 102:2823–2828PubMed
10.
Zurück zum Zitat Jakobs TF, Becker CR, Ohnesorge B et al (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef Jakobs TF, Becker CR, Ohnesorge B et al (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef
11.
Zurück zum Zitat Hausleitner J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305–1310CrossRef Hausleitner J, Meyer T, Hadamitzky M et al (2006) Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 113:1305–1310CrossRef
12.
Zurück zum Zitat Poll LW, Cohne M, Brachten S et al (2002) Dose reduction in multislice CT of the heart by use of ECG-controlled tube current modulation (“ECG-pulsing”): phantom measurements. Rofo 174:1500–1505PubMed Poll LW, Cohne M, Brachten S et al (2002) Dose reduction in multislice CT of the heart by use of ECG-controlled tube current modulation (“ECG-pulsing”): phantom measurements. Rofo 174:1500–1505PubMed
13.
Zurück zum Zitat Jakobs TF, Becker CR, Ohnesorge B et al (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef Jakobs TF, Becker CR, Ohnesorge B et al (2002) Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG controlled tube current modulation. Eur Radiol 12:1081–1086PubMedCrossRef
14.
Zurück zum Zitat Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experiance. Eur Heart J 26:1482–1487PubMedCrossRef Leschka S, Alkadhi H, Plass A et al (2005) Accuracy of MSCT coronary angiography with 64-slice technology: first experiance. Eur Heart J 26:1482–1487PubMedCrossRef
15.
Zurück zum Zitat Ropers D, Rixe J, Anders K et al (2006) Usefulness of multi-detector row spiral computed tomography with 64 × 0.6 mm collimation and 330 ms rotation fort he non-invasive detection of significant coronary artery stenoses. Am J Cardiol 97:343–348PubMedCrossRef Ropers D, Rixe J, Anders K et al (2006) Usefulness of multi-detector row spiral computed tomography with 64 × 0.6 mm collimation and 330 ms rotation fort he non-invasive detection of significant coronary artery stenoses. Am J Cardiol 97:343–348PubMedCrossRef
16.
Zurück zum Zitat Leschka S, Husmann L, Desbiolles LM et al (2006) Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT. Eur Radiol 16:1964–1972PubMedCrossRef Leschka S, Husmann L, Desbiolles LM et al (2006) Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT. Eur Radiol 16:1964–1972PubMedCrossRef
17.
Zurück zum Zitat Achenbach S, Ropers D, Kuettner A et al (2006) Contrast-enhanced coronray artery visualization by dual-source computed tomography—initial experience. Eur J Radiol 57:331–335PubMedCrossRef Achenbach S, Ropers D, Kuettner A et al (2006) Contrast-enhanced coronray artery visualization by dual-source computed tomography—initial experience. Eur J Radiol 57:331–335PubMedCrossRef
18.
Zurück zum Zitat Schmid M, Pflederer T, Jang IK et al (2008) Relationship between degree of remodeling and CT attenuation of plaque in coronary atherosclerotic lesions: an in-vivo analysis by multi-detector computed tomography. Atherosclerosis 197:457–464PubMedCrossRef Schmid M, Pflederer T, Jang IK et al (2008) Relationship between degree of remodeling and CT attenuation of plaque in coronary atherosclerotic lesions: an in-vivo analysis by multi-detector computed tomography. Atherosclerosis 197:457–464PubMedCrossRef
19.
Zurück zum Zitat Mollet NR, Hoye A, Lemos PA et al (2005) Value of preprocedure multislice computed tomographic coronary angiography to predict the outcome of percutaneous recanalization of chronic total occlusions. Am J Cardiol 95:240–243PubMedCrossRef Mollet NR, Hoye A, Lemos PA et al (2005) Value of preprocedure multislice computed tomographic coronary angiography to predict the outcome of percutaneous recanalization of chronic total occlusions. Am J Cardiol 95:240–243PubMedCrossRef
Metadaten
Titel
Differentiation of total occlusion and high-grade stenosis in coronary CT angiography
verfasst von
J. von Erffa
D. Ropers
T. Pflederer
M. Schmid
M. Marwan
W. G. Daniel
S. Achenbach
Publikationsdatum
01.12.2008
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2008
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-008-1068-9

Weitere Artikel der Ausgabe 12/2008

European Radiology 12/2008 Zur Ausgabe

Musculoskeletal

Shoulder arthroplasty

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.