Skip to main content
Erschienen in: Critical Care 1/2015

Open Access 01.12.2015 | Research

Preoperative intra-aortic balloon pump to reduce mortality in coronary artery bypass graft: a meta-analysis of randomized controlled trials

verfasst von: Alberto Zangrillo, Federico Pappalardo, Roberto Dossi, Ambra Licia Di Prima, Marta Eugenia Sassone, Teresa Greco, Fabrizio Monaco, Mario Musu, Gabriele Finco, Giovanni Landoni

Erschienen in: Critical Care | Ausgabe 1/2015

Abstract

Introduction

The intra-aortic balloon pump is routinely used in cardiac surgery; however, its impact on outcome is still a matter of debate and several randomized trials have been published recently. We perform an updated meta-analysis of randomized controlled trials that investigated the use of preoperative intra-aortic balloon pump in adult patients undergoing coronary artery bypass grafting.

Methods

Potentially eligible trials were identified by searching the Medline, Embase, Scopus, ISI Web of Knowledge and The Cochrane Library. Searches were not restricted by language or publication status and were updated in August 2014. Randomized controlled trials on preoperative intra-aortic balloon pump in patients undergoing coronary artery bypass grafting either with or without cardiopulmonary bypass were identified. The primary end point was mortality at the longest follow-up available and the secondary end point was 30-day mortality.

Results

The eight included randomized clinical trials enrolled 625 patients (312 to the intra-aortic balloon pump group and 313 to control). The use of intra-aortic balloon pump was associated with a significant reduction in the risk of mortality (11 of 312 (3.5%) versus 33 of 313 (11%), risk ratio = 0.38 (0.20 to 0.73), P for effect = 0.004, P for heterogeneity = 0.7, I-square = 0%, with eight studies included). The benefit on mortality reduction was confirmed restricting the analysis to trials with low risk of bias, to those reporting 30-day follow-up and to patients undergoing coronary artery bypass graft surgery with cardiopulmonary bypass.

Conclusions

Preoperative intra-aortic balloon pump reduces perioperative and 30-day mortality in high-risk patients undergoing elective coronary artery bypass grafting.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​s13054-014-0728-1) contains supplementary material, which is available to authorized users.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

AZ conceived the study, participated in its design and coordination, and critically revised the manuscript. FP participated in study design and coordination, helped to draft the manuscript, and critically revised it. RD did the data collection, helped with interpretation of data and to draft the manuscript. ALDP did the data collection and data entry. MES did the data collection and data entry. TG did the data collection and data entry, and did the analyses. FM helped with the data collection, interpretation of data and revising the manuscript. MM did the analyses, helped in interpretation of data and to draft the manuscript. GF conceived the study, participated in its design and coordination, helped in interpretation of data and to draft the manuscript. GL conceived the study, participated in its design and coordination, did the analyses, and drafted the manuscript. All authors read and approved the manuscript.

Introduction

The intra-aortic balloon pump is used in different clinical conditions where myocardial function is diminished, even if its effect on outcome is debated; indeed, it does not improve 30-day and one-year survival in patients with acute coronary syndrome complicated by cardiogenic shock undergoing revascularization [1,2].
Its beneficial physiological effects are well recognized: the intra-aortic balloon pump acts by increasing diastolic blood pressure [3,4] and improving diastolic coronary perfusion. Furthermore, it increases cardiac output and stroke volume by reducing afterload. The ability to act on diastolic pressure has a great importance in clinical practice since the augmented diastolic pressure results in a redistribution of coronary blood flow toward ischemic areas of the myocardium [5,6].
The perioperative use of intra-aortic balloon pump in cardiac surgery is widespread and supported by a large amount of data [7,8]. Indeed, intra-aortic balloon pump use is among the few topics with a documented improvement in survival according to randomized evidence as summarized in a recent international consensus conference [9].
A recent randomized trial on intra-aortic balloon pump use in coronary artery bypass graft surgery was underpowered to confirm the beneficial effects of intra-aortic balloon pump on survival and concluded that in patients undergoing nonemergent coronary operations, with a stable hemodynamic profile and a left ventricular ejection fraction less than 35%, the preincision (after anesthesia induction and before skin incision) insertion of intra-aortic balloon pump did not result in a better outcome [10].
We therefore decided to perform an updated meta-analysis of randomized trials studying the effect of preoperative intra-aortic balloon pump use in coronary artery bypass graft surgery to address the effect of this therapy on survival.

Materials and methods

We performed a systematic review and meta-analysis of randomized trials in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines.

Data sources and study selection

We searched for all randomized controlled trials, of any size or length of follow-up that reported the use of preoperative (before surgery) intra-aortic balloon pump in adult high-risk patients undergoing cardiac surgery. We defined as high risk the patients with at least one among: left ventricular ejection fraction <40%, left main coronary artery stenosis equal or more than 70%, reoperation, unstable angina despite medical treatment, recent acute myocardial infarction, or left ventricular hypertrophy in patients with coronary artery disease undergoing coronary artery bypass graft. Potentially eligible trials were identified by searching the Medline, Embase, Scopus, ISI Web of Knowledge and The Cochrane Library (updated 1 August 2014) using a combination of subject headings and text words to identify randomized controlled trials of preoperative intra-aortic balloon pump use. The full Medline search strategies aimed to include any randomized controlled trials ever performed on humans using preoperative intra-aortic balloon pump in any cardiac surgery is presented in Additional file 1. Searches were not restricted by language or publication status. We also examined the reference lists of eligible trials and reviews together with the abstracts of international congresses. We excluded duplicate publications, studies without mortality data, abstracts older than three years (those that did not reach the full peer review publication status) and those comparing different timing of intra-aortic balloon pump positioning (for example all patients were assigned to receive an intra-aortic balloon pump before or after surgery). Two authors independently screened the search output to identify records of potentially eligible trials, the full texts of which were retrieved and assessed for inclusion.

Outcome data

The primary end point for the present meta-analysis was mortality at the longest follow-up as reported by authors (up to three months in these trials) and the secondary end point was 30-day mortality.

Data extraction and risk of bias assessment

We extracted data on setting, outcome and length of follow-up. If a trial reported multiple comparisons, the comparators were either aggregated as a single group or excluded depending on the type of treatment and the specific analysis performed. We assessed the risk of bias associated with the method of sequence generation, allocation concealment, blinding, and the completeness of outcome data. We rated the risk of bias as being low, unclear, or high according to established criteria.

Statistical analysis

To analyze the binary outcome we calculated the natural logarithms of risk ratios and its standard deviation. We pooled these using the inverse variance method and a fixed effect model [11]. To assess heterogeneity in results of individual studies, we used Cochran’s Q statistic and the I-square statistic (I-square >25% was used as a threshold indicating significant heterogeneity). Publication bias was assessed by visually inspecting funnel plots of the primary outcome, by analytical appraisal based on the Begg adjusted-rank correlation test and on Egger’s linear regression test (a two-sided P value of 0.10 or less was regarded as significant).
Sensitivity analyses were done to quantify the effect of intra-aortic balloon pump when restricted to trials with low risk of bias, to trials that report the 30-day mortality, and divided by on- and off-pump setting. We also investigated the influence of a single study on the overall risk estimate by sequentially removing a study to test the robustness of the main results.
Statistical significance was set at the two-tailed 0.05 level for hypothesis testing. Data analysis was performed using STATA 11.0 Software (StataCorp LP, College Station, TX, USA).

Results

Characteristics of the included individual studies

Out of 238 publications we selected eight randomized trials [10,12-18] meeting the inclusion/exclusion criteria (Figure 1) while another eight manuscripts were considered major exclusions [1,19-24] because all patients had received intra-aortic balloon pump support [19,20,24], the trial was not performed only in a cardiac surgery setting [1], the abstract was published before 2011 [23], the intra-aortic balloon pump was inserted postoperatively [22] and because of overlapping population [21,2].
The eight included trials randomized 625 patients (312 to the intra-aortic balloon pump group and 313 to the control group). Table 1 shows the clinical data on setting, type of comparator, outcome data and length of follow-up. Study quality appraisal indicated that the eight included studies were of variable quality (Table S1 in Additional file 1) and that only four of them had a low risk of bias.
Table 1
Description of the eight randomized studies included in the meta-analysis
Author
Year
Journal
Setting
Time of insertion
Crossover
Complications
IABP patients
Control patients
Longest follow-up
Ranucci et al. [8]
2013
Crit Care Med
CABG
After anesthesia induction and before skin incision
7/55
4 in IABP group
55
55
30 days
Lomivorotov et al. [15]
2012
J Cardiothorac Vasc Anesth
CABG
16 to 18 hours before surgery (in the ICU)
Not reported
Not reported
30
30
30 days
Shi et al. [16]
2011
J Int Med Res
OPCABG
1 hour before surgery
Not reported
Not reported
107
125
Hospital stay
Christenson et al. [14]
2003
J Card Surg
REDO-OPCABG
After anesthesia induction and before skin incision
7/15
0
15
15
2 months
Christenson et al. [13]
1999
Ann Thorac Surg
CABG
3 different groups:
23/30
2 in IABP group
30
30
Hospital stay
−24 hours before surgery (in the ICU)
3 in crossovers
−12 hours before surgery (in the ICU)
−before anesthesia induction
Christenson et al. [10]
1997
Ann Thorac Surg
REDO-CABG
Before anesthesia induction in theatre (4 patients had insertion in the ICU before transfer to the operating room)
9/24
1 in IABP group
24
24
3 months
1 in crossover
Christenson et al. [11]
1997
Eur J Cardiothorac Surg
CABG
2 different groups
11/20
0
32
20
Hospital stay
−24 hours before surgery (in the ICU)
− preoperatively in the operating room, On average 1.5 hours before surgery
Christenson et al. [12]
1997
Thorac Cardiovasc Surg
CABG
On average 2 h before surgery
Not reported
Not reported
19
14
3 months
Crossover: number of patients assigned to the no-IABP group who received postoperative IABP insertion because of low cardiac output syndrome. CABG: coronary artery bypass graft surgery; ICU: intensive care unit; OPCABG: off-pump coronary artery bypass graft surgery; IABP: intra-aortic balloon pump; REDO: a patient who had already undergone sternotomy for cardiac surgery once in the past.

Quantitative data synthesis

The principal analysis (Figure 2) showed that the use of intra-aortic balloon pump was associated with a significant reduction in the risk of overall mortality (11 of 312 (3.5%) in the intra-aortic balloon pump group versus 33 of 313 (11%) in the control group, risk ratio = 0.38 (0.20 to 0.73), P for effect = 0.004, P for heterogeneity = 0.7, I-square = 0%, with eight studies included). Visual inspection of funnel plots did not identify a skewed or asymmetrical shape (Figure 3) and quantitative evaluation did not suggest a presence of publication bias, as measured by Egger test (P = 0.6) and Begg test (P = 0.5). Sensitivity analyses considering only data from the four studies with low risk of bias (Figure 4) confirmed the reduction in the risk of mortality (7 of 141 (5.0%) in the intra-aortic balloon pump group versus 23 of 129 (18%) in the control group, risk ratio = 0.31, (0.14 to 0.70), P for effect = 0.005, P for heterogeneity = 0.7, I-square = 0%, with four studies included). The overall result was also confirmed restricting the analysis to trials that reported the 30-day mortality (Figure 5) (11 of 254 (4.3%) in the intra-aortic balloon pump group versus 25 of 260 (9.6%) in the control group, risk ratio = 0.42 (0.21 to 0.86), P for effect = 0.02, P for heterogeneity = 0.6, I-square = 0%, with six studies included) and in surgeries performed with cardiopulmonary bypass (9 of 190 (4.7%) in the intra-aortic balloon pump group versus 27 of 173 (16%) in the control group, risk ratio = 0.36 (0.17 to 0.74), P for effect = 0.01, P for heterogeneity = 0.5, I-square = 0%, with six studies included) (Additional file 2: Figure S1).
Moreover, sensitivity analyses performed by removing each single study from the meta-analysis to determine the influence of individual data sets to the pooled risk ratios (Additional file 3: Figure S2), did not determine major changes in direction or magnitude of statistical findings, confirming for each analysis the pooled effect (risk ratio <1) and the statistical significance (P <0.05).

Discussion

The most important finding of this meta-analysis is that preoperative insertion of intra-aortic balloon pump reduces mortality in elective high-risk coronary artery bypass graft patients. This finding was already suggested by previous meta-analyses [7,8,25] but they were challenged by a recent large randomized controlled trial that concluded that the intra-aortic balloon pump was not useful in this context even if it showed a trend toward improved clinically relevant outcomes (major morbidity: 22 (40%) in the intra-aortic balloon pump group versus 17 (31%) in the control group, odds ratio =1.49 (0.68 to 3.33), P = 0.3, operative mortality: 4 (7.3%) in the intra-aortic balloon pump group versus 8 (14%) in the control group, odds ratio = 0.46 (0.13 to 1.43), P = 0.2).
When compared with other meta-analyses our work includes three recent articles for a total of 402 new patients. We also included sensitivity analyses, almost double the number of patients with respect to previous meta-analyses and, most importantly, our meta-analysis includes articles from four different research groups from four different countries.
The role of the intra-aortic balloon pump has been recently challenged by Thiele’s study [1] that showed no difference in short- and long-term survival in patients randomized to intra-aortic balloon pump versus standard treatment (risk ratio = 2.60 (0.95 to 7.10), P = 0.05), recurrent revascularization (risk ratio = 0.91 (0.58 to 1.41), P = 0.77), or stroke (risk ratio = 1.50 (0.25 to 8.84), P = 1.00) in acute coronary syndrome complicated by cardiogenic shock and planned for revascularization. It should be noted that that study is not included in this meta-analysis because only six patients underwent surgical revascularization.
The intra-aortic balloon pump acts by increasing diastolic blood pressure [3], directly improving diastolic coronary perfusion and increasing cardiac output and stroke volume by reducing afterload. The ability to act on diastolic pressure has a great importance in clinical practice because previous studies have demonstrated that the augmented diastolic pressure results in a redistribution of coronary blood flow toward ischemic areas of the myocardium [5,6].
The value of some trials is to be questioned in the light of the unacceptably high rate of intra-aortic balloon pump-related complications [26,27]. The most recent trial [10] reported two patients in the intra-aortic balloon pump study group who did not receive the balloon due to technical difficulties and four patients suffering from vascular complications (12%). Strikingly, both in the surgical [10] and nonsurgical [2] population of previously published studies there was a systematic need for crossover from the control group to the intra-aortic balloon pump group (approximately 13 to 17%), which assumes a reproducible methodological bias.

Limitations

The main limitation of the present meta-analysis is that four out of the eight included randomized controlled trials were of suboptimal quality (but the results were confirmed when analyzing only the trials with low risk of bias). Furthermore, traditional limitations of meta-analyses due to variations in the treatment regimens, in populations or major subgroups within trials, and in the conduct of the trials apply to this study [28,29]. The possibility of the beneficial effect of intra-aortic balloon pump in non-isolated coronary operations is still to be investigated since worldwide there is an increased percentage of associated procedures and some trials [10] do not specify this surgical data.

Conclusions

Prophylactic intra-aortic balloon pump use reduces perioperative mortality in high-risk patients undergoing cardiac surgery according to the most updated evidence-based medicine.

Key messages

  • Intra-aortic balloon pump is used in different clinical conditions where myocardial function is diminished.
  • Intra-aortic balloon pump acts by increasing diastolic blood pressure with consequent redistribution of coronary blood flow toward ischemic areas of the myocardium.
  • Intra-aortic balloon pump increases cardiac output and stroke volume by reducing afterload.
  • Recent evidence challenges the use of intra-aortic balloon pump after myocardial infarction.
  • Preoperative insertion of intra-aortic balloon pump reduces mortality in elective high-risk coronary artery bypass graft patients.
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

AZ conceived the study, participated in its design and coordination, and critically revised the manuscript. FP participated in study design and coordination, helped to draft the manuscript, and critically revised it. RD did the data collection, helped with interpretation of data and to draft the manuscript. ALDP did the data collection and data entry. MES did the data collection and data entry. TG did the data collection and data entry, and did the analyses. FM helped with the data collection, interpretation of data and revising the manuscript. MM did the analyses, helped in interpretation of data and to draft the manuscript. GF conceived the study, participated in its design and coordination, helped in interpretation of data and to draft the manuscript. GL conceived the study, participated in its design and coordination, did the analyses, and drafted the manuscript. All authors read and approved the manuscript.
Literatur
1.
Zurück zum Zitat Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic Balloon Pump in cardiogenic shock II (IABP-SHOCK II) trial investigators. Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial. Lancet. 2013;382:1638–45.CrossRef Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic Balloon Pump in cardiogenic shock II (IABP-SHOCK II) trial investigators. Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial. Lancet. 2013;382:1638–45.CrossRef
2.
Zurück zum Zitat Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic balloon support for myocardial infarction with cardiogenic shock. N Engl J Med. 2012;367:1287–96.CrossRef Thiele H, Zeymer U, Neumann FJ, Ferenc M, Olbrich HG, Hausleiter J, et al. Intraaortic balloon support for myocardial infarction with cardiogenic shock. N Engl J Med. 2012;367:1287–96.CrossRef
3.
Zurück zum Zitat Bolooki H. Clinical of intra-aortic balloon pump. New York: Futura Publishing Company; 1984. Bolooki H. Clinical of intra-aortic balloon pump. New York: Futura Publishing Company; 1984.
4.
Zurück zum Zitat Weber KT, Janicki JS. Intra-aortic balloon counterpulsation – a review of physiological principles, clinical results, and device safety. Ann Thorac Surg. 1974;17:602–36.CrossRef Weber KT, Janicki JS. Intra-aortic balloon counterpulsation – a review of physiological principles, clinical results, and device safety. Ann Thorac Surg. 1974;17:602–36.CrossRef
5.
Zurück zum Zitat Gill C, Wechsler A, Newman G, Oldham H. Augmentation and redistribution of myocardial blood flow during acute ischemia by intra-aortic balloon pumping. Ann ThoracSurg. 1975;16:445–53.CrossRef Gill C, Wechsler A, Newman G, Oldham H. Augmentation and redistribution of myocardial blood flow during acute ischemia by intra-aortic balloon pumping. Ann ThoracSurg. 1975;16:445–53.CrossRef
6.
Zurück zum Zitat Watson JT, Willerson JT, DE Fixler DE, Sugg NL. Temporal changes in collateral coronary blood flow in ischemic myocardium during intra-aortic balloon pumping. Circulation. 1974;50:249–54. Watson JT, Willerson JT, DE Fixler DE, Sugg NL. Temporal changes in collateral coronary blood flow in ischemic myocardium during intra-aortic balloon pumping. Circulation. 1974;50:249–54.
7.
Zurück zum Zitat Theologou T, Bashir M, Rengarajan A, Khan O, Spyt T, Richens D, et al. Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting. Cochrane Database Syst Rev. 2011; Art. No.: CD004472. Theologou T, Bashir M, Rengarajan A, Khan O, Spyt T, Richens D, et al. Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting. Cochrane Database Syst Rev. 2011; Art. No.: CD004472.
8.
Zurück zum Zitat Dyub AM, Whitlock RP, Abouzahr LL, Cinà CS. Preoperative intra-aortic balloon pump in patients undergoing coronary bypass surgery: a systematic review and meta-analysis. J Card Surg. 2008;23:79–86.CrossRef Dyub AM, Whitlock RP, Abouzahr LL, Cinà CS. Preoperative intra-aortic balloon pump in patients undergoing coronary bypass surgery: a systematic review and meta-analysis. J Card Surg. 2008;23:79–86.CrossRef
9.
Zurück zum Zitat Landoni G, Rodseth RN, Santini F, Ponschab M, Ruggeri L, Székely A, et al. Randomized evidence for reduction of perioperative mortality. J Cardiothorac Vasc Anesth. 2012;26:764–72.CrossRef Landoni G, Rodseth RN, Santini F, Ponschab M, Ruggeri L, Székely A, et al. Randomized evidence for reduction of perioperative mortality. J Cardiothorac Vasc Anesth. 2012;26:764–72.CrossRef
10.
Zurück zum Zitat Ranucci M, Castelvecchio S, Biondi A, de Vincentiis C, Ballotta A, Varrica A, et al. A randomized controlled trial of preoperative intra-aortic balloon pump in coronary patients with poor left ventricular function undergoing coronary artery bypass surgery. Crit Care Med. 2013;41:2476–83.CrossRef Ranucci M, Castelvecchio S, Biondi A, de Vincentiis C, Ballotta A, Varrica A, et al. A randomized controlled trial of preoperative intra-aortic balloon pump in coronary patients with poor left ventricular function undergoing coronary artery bypass surgery. Crit Care Med. 2013;41:2476–83.CrossRef
12.
Zurück zum Zitat Christenson JT, Badel P, Simonet F, Schmuziger M. Preoperative intraaortic balloon pump enhances cardiac performance and improves the outcome of redo CABG. Ann Thorac Surg. 1997;64:1237–44.CrossRef Christenson JT, Badel P, Simonet F, Schmuziger M. Preoperative intraaortic balloon pump enhances cardiac performance and improves the outcome of redo CABG. Ann Thorac Surg. 1997;64:1237–44.CrossRef
13.
Zurück zum Zitat Christenson JT, Simonet F, Badel P, Schmuziger M. Evaluation of preoperative intra-aortic balloon pump support in high risk coronary patients. Eur J Cardiothorac Surg. 1997;11:1097–103.CrossRef Christenson JT, Simonet F, Badel P, Schmuziger M. Evaluation of preoperative intra-aortic balloon pump support in high risk coronary patients. Eur J Cardiothorac Surg. 1997;11:1097–103.CrossRef
14.
Zurück zum Zitat Christenson JT, Simonet F, Badel P, Schmuziger M. The effect of preoperative intra-aortic balloon pump support in patients with coronary artery disease, poor left-ventricular function (LVEF < 40%), and hypertensive LV hypertrophy. Thorac Cardiovasc Surg. 1997;45:60–4.CrossRef Christenson JT, Simonet F, Badel P, Schmuziger M. The effect of preoperative intra-aortic balloon pump support in patients with coronary artery disease, poor left-ventricular function (LVEF < 40%), and hypertensive LV hypertrophy. Thorac Cardiovasc Surg. 1997;45:60–4.CrossRef
15.
Zurück zum Zitat Christenson JT, Simonet F, Badel P, Schmuziger M. Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients. Ann Thorac Surg. 1999;68:934–9.CrossRef Christenson JT, Simonet F, Badel P, Schmuziger M. Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients. Ann Thorac Surg. 1999;68:934–9.CrossRef
16.
Zurück zum Zitat Christenson JT, Licker M, Kalangos A. The role of intra-aortic counterpulsation in high-risk OPCAB surgery: a prospective randomized study. J Card Surg. 2003;18:286–94.CrossRef Christenson JT, Licker M, Kalangos A. The role of intra-aortic counterpulsation in high-risk OPCAB surgery: a prospective randomized study. J Card Surg. 2003;18:286–94.CrossRef
17.
Zurück zum Zitat Lomivorotov VV, Boboshko VA, Efremov SM, Kornilov IA, Chernyavskiy AM, Lomivorotov VN, et al. Levosimendan versus an intra-aortic balloon pump in high-risk cardiac patients. J Cardiothorac Vasc Anesth. 2012;26:596–603.CrossRef Lomivorotov VV, Boboshko VA, Efremov SM, Kornilov IA, Chernyavskiy AM, Lomivorotov VN, et al. Levosimendan versus an intra-aortic balloon pump in high-risk cardiac patients. J Cardiothorac Vasc Anesth. 2012;26:596–603.CrossRef
18.
Zurück zum Zitat Shi M, Huang J, Pang L, Wang Y. Preoperative insertion of an intra-aortic balloon pump improved the prognosis of high-risk patients undergoing off-pump coronary artery bypass grafting. J Int Med Res. 2011;39:1163–8.CrossRef Shi M, Huang J, Pang L, Wang Y. Preoperative insertion of an intra-aortic balloon pump improved the prognosis of high-risk patients undergoing off-pump coronary artery bypass grafting. J Int Med Res. 2011;39:1163–8.CrossRef
19.
Zurück zum Zitat Böning A, Buschbeck S, Roth P, Scheibelhut C, Bödeker RH, Brück M, et al. IABP before cardiac surgery: clinical benefit compared to intraoperative implantation. Perfusion. 2013;28:103–8.CrossRef Böning A, Buschbeck S, Roth P, Scheibelhut C, Bödeker RH, Brück M, et al. IABP before cardiac surgery: clinical benefit compared to intraoperative implantation. Perfusion. 2013;28:103–8.CrossRef
20.
Zurück zum Zitat Hashemzadeh K, Hashemzadeh S. Early outcomes of intra-aortic balloon pump in cardiac surgery. J Cardiovasc Surg (Torino). 2012;53:387–92. Hashemzadeh K, Hashemzadeh S. Early outcomes of intra-aortic balloon pump in cardiac surgery. J Cardiovasc Surg (Torino). 2012;53:387–92.
21.
Zurück zum Zitat Lomivorotov VV, Cherniavskiy AM, Boboshko VA, Kornilov IA, Lomivorotov VN, Karaskov AM. Levosimendan vs. intra-aortic balloon pump in high-risk cardiac surgery. Asian Cardiovasc Thorac Ann. 2011;19:154–9.CrossRef Lomivorotov VV, Cherniavskiy AM, Boboshko VA, Kornilov IA, Lomivorotov VN, Karaskov AM. Levosimendan vs. intra-aortic balloon pump in high-risk cardiac surgery. Asian Cardiovasc Thorac Ann. 2011;19:154–9.CrossRef
22.
Zurück zum Zitat Madershahian N, Wippermann J, Liakopoulos O, Wittwer T, Kuhn E, Er F, et al. The acute effect of IABP-induced pulsatility on coronary vascular resistance and graft flow in critical ill patients during ECMO. J Cardiovasc Surg (Torino). 2011;52:411–8. Madershahian N, Wippermann J, Liakopoulos O, Wittwer T, Kuhn E, Er F, et al. The acute effect of IABP-induced pulsatility on coronary vascular resistance and graft flow in critical ill patients during ECMO. J Cardiovasc Surg (Torino). 2011;52:411–8.
23.
Zurück zum Zitat Oberhoffer M, Weis M, Eifert S, Rassoulian D, Meiser B, Schmoeckel M, et al. Prospective randomized study of preoperative intraaortic balloon counterpulsation in high risk coronary artery bypass grafting patients, 542. Ottawa, Canada: 16th World Congress of the World Society of Cardio-Thoracic Surgeons; 2006. p. 191–2. Oberhoffer M, Weis M, Eifert S, Rassoulian D, Meiser B, Schmoeckel M, et al. Prospective randomized study of preoperative intraaortic balloon counterpulsation in high risk coronary artery bypass grafting patients, 542. Ottawa, Canada: 16th World Congress of the World Society of Cardio-Thoracic Surgeons; 2006. p. 191–2.
24.
Zurück zum Zitat Serraino GF, Marsico R, Musolino G, Ventura V, Gulletta E, Santè P, et al. Pulsatile cardiopulmonary bypass with intra-aortic balloon pump improves organ function and reduces endothelial activation. Circ J. 2012;76:1121–9.CrossRef Serraino GF, Marsico R, Musolino G, Ventura V, Gulletta E, Santè P, et al. Pulsatile cardiopulmonary bypass with intra-aortic balloon pump improves organ function and reduces endothelial activation. Circ J. 2012;76:1121–9.CrossRef
25.
Zurück zum Zitat Sá MP, Ferraz PE, Escobar RR, Martins WN, Nunes EO, Vasconcelos FP, et al. Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass surgery: a meta-analysis of randomized controlled trials. Coron Artery Dis. 2012;23:480–6.CrossRef Sá MP, Ferraz PE, Escobar RR, Martins WN, Nunes EO, Vasconcelos FP, et al. Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass surgery: a meta-analysis of randomized controlled trials. Coron Artery Dis. 2012;23:480–6.CrossRef
26.
Zurück zum Zitat Bignami E, Tritapepe L, Pasin L, Meroni R, Corno L, Testa V, et al. A survey on the use of intra-aortic balloon pump in cardiac surgery. Ann Card Anaesth. 2012;15:274–7.CrossRef Bignami E, Tritapepe L, Pasin L, Meroni R, Corno L, Testa V, et al. A survey on the use of intra-aortic balloon pump in cardiac surgery. Ann Card Anaesth. 2012;15:274–7.CrossRef
27.
Zurück zum Zitat Severi L, Vaccaro P, Covotta M, Landoni G, Lembo R, Menichetti A. Severe intra-aortic balloon pump complications: a single-center 12-year experience. J Cardiothorac Vasc Anesth. 2012;26:604–7.CrossRef Severi L, Vaccaro P, Covotta M, Landoni G, Lembo R, Menichetti A. Severe intra-aortic balloon pump complications: a single-center 12-year experience. J Cardiothorac Vasc Anesth. 2012;26:604–7.CrossRef
28.
Zurück zum Zitat Greco T, Zangrillo A, Biondi-Zoccai G, Landoni G. Meta-analysis: pitfalls and hints. Heart Lung Vessel. 2013;5:219–25.PubMedPubMedCentral Greco T, Zangrillo A, Biondi-Zoccai G, Landoni G. Meta-analysis: pitfalls and hints. Heart Lung Vessel. 2013;5:219–25.PubMedPubMedCentral
29.
Zurück zum Zitat Biondi-Zoccai G, Lotrionte M, Landoni G, Modena MG. The rough guide to systematic reviews and meta-analyses. HSR Proc Intensive Care Cardiovasc Anesth. 2011;3:161–73.PubMedPubMedCentral Biondi-Zoccai G, Lotrionte M, Landoni G, Modena MG. The rough guide to systematic reviews and meta-analyses. HSR Proc Intensive Care Cardiovasc Anesth. 2011;3:161–73.PubMedPubMedCentral
Metadaten
Titel
Preoperative intra-aortic balloon pump to reduce mortality in coronary artery bypass graft: a meta-analysis of randomized controlled trials
verfasst von
Alberto Zangrillo
Federico Pappalardo
Roberto Dossi
Ambra Licia Di Prima
Marta Eugenia Sassone
Teresa Greco
Fabrizio Monaco
Mario Musu
Gabriele Finco
Giovanni Landoni
Publikationsdatum
01.12.2015
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2015
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-014-0728-1

Weitere Artikel der Ausgabe 1/2015

Critical Care 1/2015 Zur Ausgabe

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.