Abstract

An anesthesiologist must remain vigilant of the patient’s clinical status, incorporating many independent physiological measurements. Oxygen saturation and heart rate are represented by continuous audible tones generated by the pulse oximeter, a mandated monitoring device. Other important clinical parameters—notably blood pressure—lack any audible representation beyond arbitrarily-configured threshold alarms. Attempts to introduce further continuous audible tones have apparently foundered; the complexity and interaction of these tones have exceeded the ability of clinicians to interpret them. Instead, we manipulate the tonal and rhythmic structure of the accepted pulse oximeter tone pattern melodically. Three melodic algorithms were developed to apply tonal and rhythmic variations to the continuous pulse oximeter tone, dependent on the systolic blood pressure. The algorithms distort the original audible pattern minimally, to facilitate comprehension of both the underlying pattern and the applied variations. A panel of anesthesia practitioners (attending anesthesiologists, residents and nurse anesthetists) assessed these algorithms in characterizing perturbations in cardiopulmonary status. Twelve scenarios, incorporating combinations of oxygen desaturation, bradycardia, tachycardia, hypotension and hypertension, were tested. A rhythmic variation in which additional auditory information was conveyed only at halftime intervals, with every other “beat” of the pulse oximeter, was strongly favored. The respondents also strongly favored the use of musical chords over single tones. Given three algorithms of tones embedded in the pulse oximeter signal, anesthesiologists preferred a melodic tone to signal a significant change in blood pressure.
Literatur
1.
Zurück zum Zitat Craven RM, McIndoe AK. Continuous auditory monitoring—how much information do we register? Br J Anaesth. 1999;83:747–9.CrossRefPubMed Craven RM, McIndoe AK. Continuous auditory monitoring—how much information do we register? Br J Anaesth. 1999;83:747–9.CrossRefPubMed
2.
Zurück zum Zitat American Society of Anesthesiologists. Standards for basic anesthetic monitoring. Park Ridge, IL: American Society of Anesthesiologists; 2011. American Society of Anesthesiologists. Standards for basic anesthetic monitoring. Park Ridge, IL: American Society of Anesthesiologists; 2011.
3.
4.
Zurück zum Zitat Chandra D, Tessler MJ, Usher J. Audio spectrum and sound pressure levels vary between pulse oximeters. Can J Anaesth. 2006;53:26–32.CrossRefPubMed Chandra D, Tessler MJ, Usher J. Audio spectrum and sound pressure levels vary between pulse oximeters. Can J Anaesth. 2006;53:26–32.CrossRefPubMed
5.
Zurück zum Zitat Nazir T, Beatty PC. Anaesthetists’ attitudes to monitoring instrument design options. Br J Anaesth. 2000;85:781–4.CrossRefPubMed Nazir T, Beatty PC. Anaesthetists’ attitudes to monitoring instrument design options. Br J Anaesth. 2000;85:781–4.CrossRefPubMed
6.
Zurück zum Zitat Watson M, Sanderson P, Russell WJ. Tailoring reveals information requirements: the case of anaesthesia alarms. Interact Comput. 2004;16:271–93.CrossRef Watson M, Sanderson P, Russell WJ. Tailoring reveals information requirements: the case of anaesthesia alarms. Interact Comput. 2004;16:271–93.CrossRef
7.
Zurück zum Zitat Loeb RG, Fitch WT. A laboratory evaluation of an auditory display designed to enhance intraoperative monitoring. Anesth Analg. 2002;94:362–8 (table of contents).PubMed Loeb RG, Fitch WT. A laboratory evaluation of an auditory display designed to enhance intraoperative monitoring. Anesth Analg. 2002;94:362–8 (table of contents).PubMed
8.
Zurück zum Zitat de Man FR, Greuters S, Boer C, Veerman DP, Loer SA. Intra-operative monitoring—many alarms with minor impact. Anaesthesia 2013;68:804–10. de Man FR, Greuters S, Boer C, Veerman DP, Loer SA. Intra-operative monitoring—many alarms with minor impact. Anaesthesia 2013;68:804–10.
9.
Zurück zum Zitat Harrison MJ, Connor CW. Statistics-based alarms from sequential physiological measurements. Anaesthesia. 2007;62:1015–23.CrossRefPubMed Harrison MJ, Connor CW. Statistics-based alarms from sequential physiological measurements. Anaesthesia. 2007;62:1015–23.CrossRefPubMed
10.
Zurück zum Zitat Connor CW, Gohil B, Harrison MJ. Triggering of systolic arterial pressure alarms using statistics-based versus threshold alarms. Anaesthesia. 2009;64:131–5.CrossRefPubMed Connor CW, Gohil B, Harrison MJ. Triggering of systolic arterial pressure alarms using statistics-based versus threshold alarms. Anaesthesia. 2009;64:131–5.CrossRefPubMed
11.
Zurück zum Zitat IEC, editor. International Standard IEC60601-1-8 (2005–08): medical electrical equipment, part 1–8: general requirements for safety—collateral standard: general requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems. Geneva: International Electrotechnical Commission; 2005. IEC, editor. International Standard IEC60601-1-8 (2005–08): medical electrical equipment, part 1–8: general requirements for safety—collateral standard: general requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems. Geneva: International Electrotechnical Commission; 2005.
12.
Zurück zum Zitat Wee AN, Sanderson PM. Are melodic medical equipment alarms easily learned? Anesth Analg. 2008;106:501–8 (table of contents).CrossRefPubMed Wee AN, Sanderson PM. Are melodic medical equipment alarms easily learned? Anesth Analg. 2008;106:501–8 (table of contents).CrossRefPubMed
13.
Zurück zum Zitat Cage the Elephant (Musical group) and Copyright Collection (Library of Congress), [Cage the Elephant. Back against the wall—music video], 2009. Cage the Elephant (Musical group) and Copyright Collection (Library of Congress), [Cage the Elephant. Back against the wallmusic video], 2009.
Metadaten
Titel
Melodic algorithms for pulse oximetry to allow audible discrimination of abnormal systolic blood pressures
verfasst von
Ranjit S. Chima
Rafael Ortega
Christopher W. Connor
Publikationsdatum
01.12.2014
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2014
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9558-6

Weitere Artikel der Ausgabe 6/2014

Journal of Clinical Monitoring and Computing 6/2014 Zur Ausgabe

Häufigste Gründe für Brustschmerzen bei Kindern

06.05.2024 Pädiatrische Diagnostik Nachrichten

Akute Brustschmerzen sind ein Alarmsymptom par exellence, schließlich sind manche Auslöser lebensbedrohlich. Auch Kinder klagen oft über Schmerzen in der Brust. Ein Studienteam ist den Ursachen nachgegangen.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärzte und Psychotherapeuten.

Beutel versus Maschine: Beste Beatmungstechnik bei Herzstillstand gesucht

02.05.2024 Kardiopulmonale Reanimation Nachrichten

Stehen die Chancen auf eine Rückkehr der Spontanzirkulation nach Herz-Kreislauf-Stillstand bei manueller oder maschineller Beatmung besser? Und unterscheidet sich das neurologische Outcome nach der Reanimation? Das belgische Herzstillstand-Register liefert die Daten für einen direkten Vergleich zwischen Beutel und Beatmungsgerät.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.