Skip to main content
Erschienen in: Annals of Intensive Care 1/2012

Open Access 01.12.2012 | Research

Non-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver

verfasst von: Manuel Ignacio Monge García, Anselmo Gil Cano, Manuel Gracia Romero, Rocío Monterroso Pintado, Virginia Pérez Madueño, Juan Carlos Díaz Monrové

Erschienen in: Annals of Intensive Care | Ausgabe 1/2012

Abstract

Background

The passive leg-raising (PLR) maneuver provides a dynamic assessment of fluid responsiveness inducing a reversible increase in cardiac preload. Since its effects are sudden and transitory, a continuous cardiac output (CO) monitoring is required to appropriately assess the hemodynamic response of PLR. On the other hand, changes in partial end-tidal CO2 pressure (PETCO2) have been demonstrated to be tightly correlated with changes in CO during constant ventilation and stable tissue CO2 production (VCO2). In this study we tested the hypothesis that, assuming a constant VCO2 and under fixed ventilation, PETCO2 can track changes in CO induced by PLR and can be used to predict fluid responsiveness.

Methods

Thirty-seven mechanically ventilated patients with acute circulatory failure were monitored with the CardioQ-ODM esophageal Doppler. A 2-minutes PLR maneuver was performed. Fluid responsiveness was defined according to CO increase (responders ≥ 15%) after volume expansion.

Results

PLR-induced increases in CO and PETCO2 were strongly correlated (R2 = 0.79; P < 0.0001). The areas under the receiver-operating characteristics (ROC) curve for a PLR-induced increase in CO and PETCO2 (0.97 ± 0.03 SE; CI 95%: 0.85 to 0.99 and 0.94 ± 0.04 SE; CI 95%: 0.82 to 0.99; respectively) were not significantly different. An increase ≥ 5% in PETCO2 or ≥ 12% in CO during PLR predicted fluid responsiveness with a sensitivity of 90.5% (95% CI: 69.9 to 98.8%) and 95.2% (95% CI: 76.2 to 99.9%), respectively, and a specificity of 93.7% (95% CI: 69.8 to 99.8%).

Conclusion

Induced changes in PETCO2 during a PLR maneuver could be used to track changes in CO for prediction of fluid responsiveness in mechanically ventilated patients with acute circulatory failure, under fixed minute ventilation and assuming a constant tissue CO2 production.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​2110-5820-2-9) contains supplementary material, which is available to authorized users.

Competing interests

MIMG has received consulting fees from Edwards Lifesciences. The other authors have no competing interests to disclose.

Authors' contributions

MIMG, AGC and JCDM conceived the study. MIMG designed the study, participated in the recruitment of patients, performed the statistical analysis, interpreted the data and drafted the manuscript. AGC participated in the study design, interpreted data and helped draft the manuscript. MGR, RMP and VPM participated in patient recruitment, data collection and technical support. All authors contributed to the critical review of the manuscript and approved the final manuscript.
Abkürzungen
ΔCOPLR
Passive leg raising-induced changes in cardiac output (%)
ΔPETCO2-PLR
Passive leg raising-induced changes in partial end-tidal CO2 pressure (%)
ΔPP-PLR
Passive leg raising-induced changes in arterial pulse pressure (%)
Acc
Mean acceleration of aortic blood velocity
ARDS
Acute respiratory distress syndrome
CE
Coefficient of error
CI
Confidence interval
CO
Cardiac output
CV
Coefficient of variation
FTc
Corrected flow time
GRI
Guyatt's Responsiveness Index
IQR
Interquartile range
LSC
Least significant change
MAP
Mean arterial pressure
PEEP
Positive end-expiratory pressure
PETCO2
Partial end-tidal CO2 pressure
PLR
Passive leg raising
PP
Arterial pulse pressure
SV
Stroke volume
VCO2
Metabolic CO2 production
VE
Volume expansion.

Background

The passive leg-raising (PLR) maneuver provides a dynamic assessment of preload dependence inducing a transient and reversible increase in cardiac preload. The abrupt transfer of blood contained in the venous reservoir of the legs and splanchnic compartment while moving the patient from a semirecumbent to supine position with legs elevated increases cardiac preload as a 'self-volume challenge' and, when both ventricles are operating in the steep part of the Frank-Starling curve, also improves cardiac output (CO) [1]. This maneuver has been demonstrated to predict fluid responsiveness in many studies over a wide population, including clinical situations in which other parameters of fluid responsiveness have failed, such as patients with cardiac arrhythmias or with spontaneous breathing [13]. However, since the hemodynamic effects of PLR are usually sudden and transient, a fast-response continuous CO monitor is required to detect these changes and to characterize fluid responder patients accurately [46]. In this regard, several monitoring techniques have been proposed for this purpose: echocardiography [2, 3, 7], arterial pulse contour analysis [8, 9], bioreactance [10], esophageal Doppler [1, 11, 12], and so on. Nevertheless, the need for measuring CO usually limits the widespread application of this test to a specific group of patients requiring expensive, burdensome or invasive hemodynamic monitoring systems.
The relationship between CO and partial end-tidal CO2 pressure (PETCO2) has been known for decades [13, 14], so measurement of PETCO2 has been proposed to confirm the restoration of spontaneous circulation in patients with cardiac arrest [15], but also as a quantitative indicator of hemodynamic effectiveness of precordial compression during cardiopulmonary resuscitation [16]. Moreover, since PETCO2 is mainly determined by tissue CO2 production (VCO2), alveolar ventilation and CO (that is, pulmonary blood flow) [17], when stable metabolic conditions are assumed and minute ventilation is kept constant, acute changes in PETCO2 have been shown to correlate strongly with changes in CO in experimental [1824] and clinical [25, 26] settings. Thus, PETCO2 has been suggested as a noninvasive alternative for continuous assessment of CO in different shock states [20].
The aim of the present study, therefore, was to assess whether PETCO2 monitoring can track changes in CO induced by PLR and can be used as a noninvasive surrogate for predicting fluid responsiveness in mechanically ventilated patients with acute circulatory failure requiring fluid administration.

Methods

This study was prospectively conducted in a 17-bed adult multidisciplinary Intensive Care Unit of the Hospital del SAS Jerez de la Frontera. The study protocol was approved by the Institutional Ethics Committee of the Hospital Jerez of the Andalusian Health Service and endorsed by the Scientific Committee of the Spanish Society of Intensive Care, Critical and Coronary Units (SEMICYUC). Written informed consent was obtained from each patient's next of kin.

Patients

Inclusion criteria were patients with controlled mechanical ventilation and for whom the attending physician decided to give fluids due to the presence of at least one of the following signs of circulatory failure: systolic blood pressure ≤ 90 mmHg or a decrease ≥ 50 mmHg in a previously hypertensive patient; the need of vasopressor drugs; urine output ≤ 0.5 ml/kg/hr during at least two hours; heart rate > 100 beats/minute; and presence of skin mottling or delayed capillary refilling. Exclusion criteria were age < 18 years, pregnancy, any contraindication for the use of esophageal Doppler (recent esophageal surgery, malformation, varicose or tumor) or to perform PLR (intracranial hypertension, deep venous thrombosis, the use of venous elastic compression stockings, or limb and pelvic fractures).
To avoid changes in alveolar ventilation, patients were ventilated in volume control mode and spontaneous respiratory movements were temporally suppressed with a neuromuscular blockade agent (0.1 mg/kg vecuronium bromide) if detected in airway pressure trace in the respiratory monitor.

Measurements

Respiratory measurements

PETCO2 was continuously measured at the tip of the endotracheal tube using a sidestream infrared gas analyzer (compact airway module M-COVX, Datex-Ohmeda, Helsinki, Finland) integrated into the patient monitor (S/5, Datex-Ohmeda, Helsinki, Finland) and recorded online in a laptop computer every 10 seconds using proprietary data acquisition software (S/5 Collect software, version 4.0; Datex-Ohmeda, Helsinki, Finland). The validation of this compact modular metabolic monitor for use in mechanically ventilated patients in the ICU has been published elsewhere [27]. The precision of the gas analyzer module for PETCO2 measurements was calculated as twice its coefficient of variation (CV = SD/mean), determined in all studied patients at baseline during stable hemodynamic and respiratory conditions. The least significant change (LSC) was calculated as the precision × √2, which sets the minimum percentage change between successive measurements that can be considered not due to random error and therefore representing a real change in PETCO2 [28]. Since as the random error increases, larger effects are necessary to detect a real change, responsiveness of the gas analyzer for PETCO2 measurements was also calculated, which refers to the ability to detect a change over time, providing an estimation of the 'sensitivity to change' of a measurement tool [29]. We calculated the Guyatt's Responsiveness Index (GRI) as GRI = LSC divided by the standard deviation of the PLR-induced changes in PETCO2. A GRI value ≥ 0.8 is considered a high responsiveness [30].

Hemodynamic measurements

Hemodynamic monitoring was performed using the CardioQ-ODM™ esophageal Doppler monitor (Deltex Medical, Chicester, UK). This device allows minimally invasive real-time CO monitoring by measuring aortic blood flow velocity at the descending thoracic aorta, assuming a constant aortic diameter (obtained from a nomogram based on the patient's age, weight and height) and that a constant proportion of the CO flows through the descending aorta [31]. This monitor also provides other flow-related hemodynamic parameters: the corrected flow time (FTc), which is adjusted to the heart rate using Bazett's formula (FTc = the systolic blood flow time divided by the square root of the cycle time) and has been proposed as a gross estimation of the loading condition of the heart [32]; and the mean acceleration (Acc), which represents the mean acceleration of the aortic blood flow and has been suggested as an indicator of the left ventricular systolic function [33]. The Doppler probe was inserted into the esophagus via the nasal route and advanced until it achieved the maximal aortic blood flow velocity signal. The gain setting was then adjusted to obtain the optimum outline of the aortic velocity waveform. Hemodynamic parameters were continuously recorded every 10 seconds for further offline analysis.
All Doppler measurements were performed by the same observer (MIMG). The intraobserver reproducibility for CO measurements was determined using the Bland-Altman test analysis in ten randomly selected patients over a one-minute period and described as bias ± limits of agreements (1.96SD), and presented as percentages and absolute values (in brackets). We also calculated precision and LSC for Doppler CO measurements at pre-infusion and post-infusion stages. Since Doppler parameters were averaged during one minute before and after fluid administration, precision was determined by the coefficient of error (CE = CV/√N, where N = 6 is the number of measurements) and LSC as 2√2 × CE [28].

Study protocol

The study protocol was performed in four sequential stages (Figure 1). A first set of measurements was recorded with the patient in the semirecumbent position (baseline). Next the PLR maneuver was performed by setting the patient in the supine position and simultaneously raising the patient's leg to 45° to maximize the hemodynamic effect of the test (PLR) [9]. The patient was then returned to the semirecumbent position and, after five minutes, a new set of measurements was obtained before (pre-infusion) and immediately after fluid administration (post-infusion), which consisted of 500 ml of a synthetic colloid (Voluven 6% hydroxyethyl starch solution 130/0.4; Fresenius Kabi, Bad Homburg, Germany) administered over 30 minutes. The hemodynamic and PETCO2 measurements during each protocol period were expressed as an average of the measurements collected during one minute, except for the PLR stage, in which they were recorded at the moment at which they reached their maximum values [1].
Supportive therapies, ventilatory settings and vasopressor therapy were kept unchanged throughout the study period.

Statistical analysis

Normal distribution of data was tested using the D'Agostino-Pearson test. All variables except PETCO2 were normally distributed. The results are expressed as means ± SD or as median and the interquartile range (IQR), as appropriate. Sample size was calculated for detection of differences of 0.10 with known expected area under the ROC curve [34]. We selected a type I error of 0.05 and a type II error of 0.2, assuming that fluid responsiveness occurs in 50% of ICU patients [35]. Patients were classified according to CO increase after fluid administration as responders (≥ 15%) and non-responders, respectively [1, 11]. To validate this cutoff we determined that every responder patient increased CO above the individual LSC value [28]. Differences between responders and non-responders were compared by means of an independent sample t-test for hemodynamic parameters and by the Mann-Whitney U test for PETCO2 measurements. The effects of fluid administration on hemodynamic parameters were assessed using a paired Student's t-test and by Wilcoxon rank sum test for PETCO2 measurements. The relationships between variables were analyzed using a linear regression method. The ability of PETCO2 to track directional changes in CO (trending capability) during PLR and fluid administration was tested using a concordance analysis. Concordance was defined as the percentage of data in which the direction of change was in agreement [36]. The area under the ROC curves for PLR-induced changes in CO (ΔCOPLR) and PETCO2 (ΔPETCO2-PLR), and pre-infusion FTc according to volume expansion (VE) response were calculated and compared using the Hanley-McNeil test. ROC curves are presented as area ± SE (95% confidence interval). A P value < 0.05 was considered statistically significant. All statistical analyses were two-tailed and were performed using MedCalc software for Windows version 11.6.1.0 (MedCalc Software bvba, Mariakerke, Belgium).

Results

Patients' characteristics

From January to May 2011, 37 consecutive patients were included. Two patients were excluded because of inability to acquire an adequate Doppler signal. Patients' characteristics are summarized in Table 1, including 21 fluid responders (57%) and 16 non-responders. All the patients had sinus rhythm, although transient supraventricular extrasystoles were observed during the study in some patients (13%).
Table 1
Characteristics and demographic data of study population
Age (years)
64 ± 13
Gender (M/F)
16/21
Weight (kg)
77 ± 17.2
Height (cm)
166.9 ± 7.6
Body surface area (m 2 )
1.88 ± 0.21
Body mass index (Kg m -2 )
25.9 (23.4 to 31.2)
APACHE II score at admission
18.8 ± 7.3
ICU survival rate (%)
24 (65%)
Plasma lactate level, mmol/L
2.79 ± 1.82
Ventilator settings
 
Tidal volume, mL/Kg predicted body weight
8.1 ± 1.2
Respiratory rate, b.p.m.
20 (18 to 20)
Total PEEP, cm H 2 O
6.4 (4 to 8)
Mean airway pressure, cmH 2 O
12 (9.4 to 13)
Peak airway pressure, cmH 2 O
31.1 ± 6.2
FiO 2 ,%
0.73 ± 0.2
Vasoactive agents, n; dose (μg kg -1 min -1 )
 
Norepinephrine
22; 0.23 (0.08 to 0.33)
Dobutamine
6; 6.2 (3.3 to 9.5)
Analgesia and sedative drugs
 
Fentanyl, n; dose (μg kg -1 h -1 )
24; 1.58 ± 0.53
Remifentanyl, n; dose (μg kg -1 min -1 )
13; 0.14 ± 0.04
Midazolam, n; dose (mg kg -1 h -1 )
24; 0.09 ± 0.03
Propofol, n; dose (mg kg -1 min -1 )
2; 0.79 (0.7 to 0.89)
ARDS, n
3
Days on mechanical ventilation
1 (1 to 1)
ICU length of stay, days
8 (5 to 16)
Reason for fluid administration, n (%)
 
Hypotension
11 (30%)
Oliguria
30 (81%)
Decrease vasoactive dosage
19 (51%)
Sepsis/Septic shock
26 (70%)
Abdominal
11 (30%)
Pulmonary
10 (27%)
Urological
2 (7%)
Neurological
2 (7%)
Other
1 (3%)
APACHE, Acute Physiologic and Chronic Health Evaluation; ARDS, acute respiratory distress syndrome; F, female; FiO2, inspired oxygen fraction; ICU, intensive care unit; M, male; PEEP, positive end-expiratory pressure; SaO2, arterial oxygen saturation. Values are expressed as mean ± SD, median (25th to 75th percentile) or absolute numbers, as appropriate
The intraobserver variability for esophageal Doppler CO measurements was 0.6 ± 4.9% (-0.02 ± 0.21 L/min). At pre-infusion, the precision and mean LSC for Doppler CO measurements were 2.3% (IQR: 1.7 to 3%; 95% CI: 1.8 to 2.7%) and 3.2% (IQR: 2.4 to 4.2%; 95% IC: 2.5 to 3.8%), respectively; at post-infusion, these values were 1.9% (IQR: 1.3 to 3.9%; 95% CI: 1.5 to 2.6%) and 2.6% (IQR: 1.8 to 5.4%; 95% IC: 2.1 to 3.6%). For PETCO2 measurements, the precision and mean LSC were 1.3% (IQR: 1.04 to 1.7%; 95% CI: 1.09 to 1.57%) and 1.84% (IQR: 1.47 to 2.41%; 95% CI: 1.54 to 2.22%), respectively. The responsiveness of the gas analyzer according to Guyatt's Responsiveness Index was 1.58 (IQR: 1.26 to 2.07; 95% IC: 1.32 to 1.91).

Effects of passive leg-raising maneuver

Overall, the PLR maneuver increased CO by 15.9 ± 9.1% (95% CI: 12.9 to 18.9%; P < 0.0001), stroke volume (SV) by 15.5 ± 10.2% (95% CI: 12.1 to 18.9%; P < 0.0001), FTc by 8.4 ± 6% (95% CI: 6.4 to 10.4%; P < 0.0001), mean arterial pressure (MAP) by 5.4% (IQR: 1.3 to 10.2%; 95% CI: 1.8 to 7.6%; P < 0.0001), arterial pulse pressure (PP) by 10.1% (IQR: 2.3 to 21.8; P < 0.0001), and PETCO2 by 5.32 ± 3.09% (95% CI: 4.29 to 6.35%; P < 0.0001). Neither heart rate nor Acc changed during PLR.
In fluid-responder patients, ΔPETCO2-PLR was 7.34 ± 2.26% (95% CI: 6.32 to 8.37%) with an absolute increase of 2.54 ± 0.99 mmHg (95% CI: 2.09 to 2.99 mmHg), whereas in non-responders, this value was 2.66 ± 1.69% (95% CI: 1.76 to 3.56%), with an absolute increase of 0.92 ± 0.61 mmHg (95% CI: 0.59 to 1.24 mmHg). All volume responders showed a ΔPETCO2-PLR greater than their individual baseline LSCs.
The CO increase during PLR strongly correlated with ΔPETCO2-PLR (R2 = 0.79; P < 0.0001) but was weaker with PLR-induced changes in arterial PP (R2 = 0.29; P < 0.001) (Figure 2). The directional changes between ΔPETCO2-PLR and CO induced by PLR displayed a 97% concordance.
After the PLR maneuver, at the pre-infusion period, all the parameters returned to similar baseline values.

Effects of volume expansion

In the entire study population, VE increased CO by 18.9 ± 17.1% (95% CI: 13.1 to 24.6%; P < 0.0001), SV by 17.4% (IQR: 6.1 to 31.2%; 95% CI: 9.3 to 22.3; P < 0.0001); FTc by 8.4 ± 8.7% (95% CI: 5.5 to 11.3%; P < 0.0001), MAP by 4.7% (IQR: 1.2 to 13.4%; 95% CI: 2.3 to 10.6%; P = 0.0001); arterial PP by 12.5% (IQR: 1.6 to 25.9; P < 0.001); and PETCO2 by 1.69 ± 3.55% (95% CI: 0.51 to 2.88% mmHg; P < 0.01). All the VE-responder patients exhibited an increase in CO after VE greater than their individual LSC values for Doppler CO measurements.
The VE-induced increase in CO was correlated with changes in PETCO2, PP and FTc after fluid administration (R2 = 0.56, R2 = 0.45 and R2 = 0.7, respectively; P < 0.0001). Changes between VE-induced increases in PETCO2 and CO showed a 59% concordance. Furthermore, CO increase after fluid administration was also correlated with ΔCOPLR and ΔPETCO2-PLR (R2 = 0.7 and R2 = 0.55, respectively; P < 0.0001) (Figure 3). So, the greater the changes in CO and PETCO2 during the PLR maneuver, the greater the expected increase in CO after VE. No correlation between pre-infusion FTc values and VE-induced changes in CO was observed (R2 = 0.09; P: n.s.).
The hemodynamic and PETCO2 measurement throughout the four stages are summarized in Table 2.
Table 2
Effects of passive leg raising maneuver and volume expansion on hemodynamics and partial end-tidal CO2
 
Baseline
PLR
Preinfusion
After VE
CO, L/min
    
Responders
5.40 ± 2.25
6.54 ± 2.53b
5.33 ± 2.43
6.81 ± 2.81c
Non-responders
6.51 ± 2.47
7.03 ± 2.73b
6.48 ± 2.52
6.85 ± 2.89c
SV, mL
    
Responders
53.5 ± 26.3a
63.8 ± 26.5b
52.5 ± 26.9a
68.1 ± 27.5c
Non-responders
76.4 ± 31.3
82.7 ± 33.5b
76.3 ± 30.9
81.5 ± 33.1c
HR, b.p.m.
    
Responders
106 ± 25a
106 ± 24a
106 ± 26a
103 ± 24a
Non-responders
88 ± 20
87 ± 18
87 ± 20
86 ± 19
FTc, ms
    
Responders
292 ± 51a
323 ± 50b
291 ± 52a
327 ± 54c
Non-responders
343 ± 61
360 ± 74b
342 ± 62
355 ± 83
Acc, m/s 2
    
Responders
9.6 ± 4.5
9.7 ± 4.9
9.3 ± 4.6
10.4 ± 5.4c
Non-responders
10.3 ± 3.9
10.5 ± 4.1
10.3 ± 3.9
10.7 ± 4.7
SAP, mmHg
    
Responders
107 ± 21
120 ± 21b
108 ± 21
122 ± 25c
Non-responders
107 ± 14
111 ± 16b
105 ± 15
111 ± 18c
DAP, mmHg
    
Responders
61 ± 11
65 ± 12b
61 ± 12
64 ± 12c
Non-responders
63 ± 11
66 ± 10b
63 ± 10
65 ± 10c
MAP, mmHg
    
Responders
76 ± 14
83 ± 13b
75 ± 14
83 ± 15c
Non-responders
78 ± 12
82 ± 12b
77 ± 12
81 ± 13c
PP, mmHg
    
Responders
45.8 ± 15.7
55.3 ± 18.3b
46.9 ± 13.6
57.7 ± 19.7a, c
Non-responders
42.1 ± 10.1
45.2 ± 11.9b
42.1 ± 11.3
45.9 ± 12.9c
CPO, W
    
Responders
0.92 ± 0.44
1.22 ± 0.49b
0.91 ± 0.47
1.25 ± 0.51c
Non-responders
1.10 ± 0.38
1.26 ± 0.46b
1.11 ± 0.43
1.23 ± 0.53c
TSVR, dyn·s·cm -5
    
Responders
1264 ± 442
1143 ± 368b
1299 ± 481
1130 ± 451c
Non-responders
1124 ± 535
1091 ± 510
1119 ± 504
1133 ± 538
PETCO 2 , mmHg
    
Responders
35 (30 to 37)
38 (33 to 40)b
35 (29 to 37)
36 (30 to 38)c
Non-responders
34 (30 to 37)
35 (30 to 38)b
34 (29 to 37)
34 (28 to 37)
Acc, mean aortic blood flow acceleration; CO, cardiac output; CPO, cardiac power output (mean arterial pressure x cardiac output/451);, DAP, diastolic arterial pressure; HR, heart rate; FTc, aortic blood flow corrected time; MAP, mean arterial pressure; PETCO2, partial end-tidal CO2 pressure; PP, arterial pulse pressure (systolic minus diastolic pressure); SAP, systolic arterial pressure; SV, stroke volume; TSVR, total systemic vascular resistance
aP < 0.05 versus non-responders; bP < 0.05 versus baseline; cP < 0.05 versus preinfusion. Data are expressed as mean ± SD, except for PETCO2 as median (25th to 75th percentiles)

Prediction of fluid responsiveness

The area under the ROC curve for ΔCOPLR (0.97 ± 0.03; 95% CI: 0.85 to 0.99) and ΔPETCO2-PLR (0.94 ± 0.03; 95% CI: 0.82 to 0.99) was not significantly different but was higher than for pre-infusion FTc (0.75 ± 0.08; 95% CI: 0.58 to 0.88; P < 0.01) and baseline PP (0.73 ± 0.09; 95% CI: 0.55 to 0.86; P < 0.01) (Figures 4 and 5). An absolute increase in PETCO2 value ≥ 2 mmHg during PLR was associated with a positive response to fluid administration in all cases.
The comparison of predictive performance of different hemodynamic parameters and ΔPETCO2-PLR for detecting fluid responsiveness is given in Table 3.
Table 3
Predictive performance for detecting fluid responsiveness
 
Threshold
Sensitivity
Specificity
PV +
PV -
LR +
LR -
ΔCO PLR
12%
95.2%
93.7%
95.2%
93.7%
15.24
.05
[95% CI]
 
[76.2-99.9%]
[69.8-99.8%]
[75.5-99.9%]
[69.8-99.8%]
[13-17.9]
[0.003-0.8]
ΔPETCO 2-PLR
5%
90.5%
93.7%
95%
88.2%
14.48
.1
[95% CI]
 
[69.6-98.8%]
[69.8-99.8%]
[75.1-99.9%]
[62.6-98.7%]
[12-17.5]
[0.01-1]
FTc
300 ms
66.7%
81.2%
82.4%
65%
3.56
.41
[95% CI]
 
[43-85.4%]
[54.4-96%]
[55.6-96.5%]
[40.8-84.6%]
[2.4-5.2]
[0.1-1.3]
ΔPP PLR
11%
66.7%
81.2%
82.4%
65%
3.56
.41
[95% CI]
 
[43-85.4%]
[54.4-96%]
[55.6-96.5%]
[40.8-84.6%]
[2.4-5.2]
[0.1-1.3]
ΔCOPLR, passive leg raising induced-change in cardiac output; ΔPETCO2-PLR, passive leg raising-induced change in partial end-tidal CO2;, ΔPP-PLR, passive leg raising-induced change in arterial pulse pressure; FTc, aortic blood flow corrected time; PV+, positive predictive value; PV -, negative predictive value; LR+, positive likelihood ratio; LR-, negative likelihood ratio

Discussion

The main finding of this study is that, under fixed minute ventilation and assuming a constant tissue CO2 production, acute changes in partial end-tidal CO2 pressure during the passive leg-raising maneuver are strongly correlated with changes in cardiac output measured by an esophageal Doppler and could provide a reliable and non-invasive method for predicting fluid responsiveness in mechanically ventilated patients with acute circulatory failure.
Although intravascular volume therapy remains a keystone in the treatment of patients with acute circulatory failure, the benefits of fluid administration seem to be defined within relatively narrow boundaries: on the one hand, excessive fluid therapy appears to be associated with higher morbimortality in critical ill patients and, on the other hand, inadequate fluid resuscitation could aggravate tissue hypoperfusion and organ dysfunction [37]. Furthermore, for physiological reasons, the hemodynamic response to a fluid challenge is not easily predictable, since the expected improvement in CO is only observed in half the patients [35]. In this regard, the PLR maneuver has been proposed as a reliable method for predicting fluid responsiveness, challenging the cardiovascular system to a reversible and transient increase in cardiac preload by mobilizing venous blood contained in the lower limbs and abdominal compartment toward the intrathoracic vessels. Only if both ventricles are operating in the steep part of the cardiac function curve will this increment in preload result in a significant increase in CO and, therefore, in a similar response after volume administration [6].
Our results confirm the ability of the PLR maneuver to detect preload dependence and the strong relationship between changes induced by PLR and VE-induced increases in CO [6, 34]. Moreover, the ΔCOPLR cutoff for predicting fluid responsiveness is also consistent with previous studies in which esophageal Doppler was employed [1, 11] and similar to the recommended threshold value for interpretation of PLR maneuver effects [6, 34]. Accordingly, when CO increased above 12%, 95% of the studied patients increased their CO after fluid administration.
Exhaled or end-tidal CO2 is mainly determined by pulmonary blood flow (that is, CO), metabolic CO2 production (VCO2) and alveolar ventilation; so PETCO2 varies directly with VCO2 and CO and inversely with alveolar ventilation [17]. Therefore, assuming that during PLR the systemic metabolic rate remained relatively constant (and minute ventilation was kept unchanged), then changes in PETCO2 should predominantly reflect variations in pulmonary blood flow and thus, indirectly, changes in CO. The strong relationship observed between changes in PETCO2 and CO during PLR supports this hypothesis and it is also in agreement with numerous studies performed under similar conditions [1826]. For this reason, the measurement of PETCO2 has been advocated as a simple and noninvasive parameter of the circulatory status for monitoring the resumption of spontaneous circulation and the efficacy of chest compressions during cardiac arrest [15] but also as a prognostic indicator in cardiopulmonary resuscitation [38] and emergency trauma surgery [39].
According to previous observations [22, 25], the increase in PETCO2 induced by PLR could be explained at least by two mechanisms. First, if PLR increases venous return and pulmonary blood flow, then CO2 delivery to the lungs (that is, pulmonary arterial CO2 content) and CO2 removal should be increased. Second, by increasing pulmonary perfusion pressure, PLR could recruit previous collapsed pulmonary vessels and reduce alveolar spaces with high ventilation-to-perfusion mismatch or alveolar dead space. This latter phenomenon could be particularly striking in patients with severely impaired pulmonary perfusion pressure, as seen in deep hemorrhagic shock [18, 19, 21, 23] or patients with alveolar overdistension due to high levels of PEEP [40]. In this latter regard, a recent study by Fougéres et al. [41] demonstrated that in patients with ARDS who were ventilated with high levels of PEEP, the PLR maneuver improved the cardiac index but also was associated with a decrease in pulmonary vascular resistance, which suggested that by increasing central blood volume, PLR decreased PEEP-induced West zones 1 with subsequent decrease in alveolar dead space. Unfortunately, since we did not measure arterial CO2 pressure, we cannot estimate the relative influence of changes in dead space during PLR. In any case, according to the above explanation, whatever the underlying mechanism, the increase in PETCO2 is determined ultimately to an effective increase in pulmonary blood flow and improved efficiency of alveolar CO2 excretion [22, 25].
Although the relationship between CO and PETCO2 was initially described as linear [14, 22, 24, 25], other authors have suggested that a logarithmic function better defines this association [18, 20, 21]. According to the latter, in low-flow states (as during cardiac arrest or severe hemorrhagic shock), for a given change in CO a larger variation in PETCO2 should be expected [18, 20, 21]. This marked reduction in PETCO2 at low CO values might be attributed not only to limited CO2 elimination, but also to changes in metabolic CO2 production during oxygen supply dependency [2123]. In contrast, at high CO values, pulmonary blood flow would not be the limiting factor for PETCO2, and thus, changes in PETCO2 would not reflect its variations but mainly the adequacy of alveolar ventilation [18, 20]. Although our study was not designed to address this specific issue, the strong association observed during PLR between fractional changes in CO and PETCO2 suggests that, under the conditions described by the study protocol, this relationship remains valid over the wide range of studied CO values. Furthermore, the moderate magnitude of transient changes in CO produced by PLR (in contrast with marked and sustained decreases induced in some studies [1821]) and the timing between PETCO2 and CO measurements [25] may also have contributed to the observed findings in our study. When perturbations in CO were produced over a brief period of time and PETCO2 measurements were performed within a relatively short time frame, similar results have been observed in previous studies [22, 25].
Before drawing conclusions from our results, some considerations should be mentioned. First, the assessment of fluid responsiveness using PETCO2 variations should potentially share the same limitations as interpreting CO changes during PLR, since in this context the former is in essence just a surrogate for the latter. Therefore, any condition that could affect the ability of PLR to predict fluid responsiveness (for example, intraabdominal hypertension) [12] should also be considered when analyzing PETCO2 changes. Second, to prevent fluctuations in minute ventilation, all the patients were mechanically ventilated in volume control mode, deeply sedated and fully adapted to the ventilator with no inspiratory efforts. Consequently, in spontaneously breathing patients, the unpredictable variations in alveolar ventilation could make the analysis of changes in PETCO2 more difficult. For this reason, this population was deliberately excluded from the study and extrapolation of our results to this clinical condition cannot be recommended. Third, the assessment of PETCO2 variations is also based in the assumption that no significant changes in metabolic CO2 production have been produced while performing the PLR maneuver. If the metabolic rate varies considerably (for example, during shivering, fever, and so on), the observed changes in PETCO2 could not be attributed solely to modifications in CO and thus the ability of PETCO2 variations to predict fluid responsiveness could be diminished. However, the maximum hemodynamic effects of PLR take place primarily during the first minute [6], so it is very unlikely that this phenomenon will occur in such a short period of time. By contrast, since infusion time was significantly longer, this assumption is more difficult to sustain and could be one of the reasons for the weaker relationship between changes in CO and PETCO2 after fluid administration. However, even under these circumstances, the VE-induced increase in CO still accounted for more than 50% of the observed changes in PETCO2. Finally, the 5% cutoff found for changes in PETCO2 represents an increase of no more than 2 mmHg, which a priori could be attributed to a low signal-to-noise ratio and easily interpreted as a measurement error. Nonetheless, we effectively confirmed that this value is almost three times the LSC for PETCO2 measurement, so under the same conditions, an increase above this threshold should represent an actual increase in PETCO2 and the presence of fluid responsiveness. Despite these considerations, PETCO2 measurement could offer an easily available, totally noninvasive method for the assessment of fluid responsiveness with similar performance as measuring CO, but without the need of any hemodynamic monitoring device, when similar clinical conditions are present (uniform alveolar ventilation and constant VCO2).

Conclusions

In our study we demonstrated that PETCO2 effectively tracked changes in CO during the PLR maneuver and predicted fluid responsiveness in patients with acute circulatory failure with fixed minute ventilation, assuming a constant tissue CO2 production.

Acknowledgements

The authors thank the nursing staff at the Intensive Care Unit of the Hospital de SAS Jerez de la Frontera for their assistance with this study.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 2.0 International License (https://​creativecommons.​org/​licenses/​by/​2.​0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Competing interests

MIMG has received consulting fees from Edwards Lifesciences. The other authors have no competing interests to disclose.

Authors' contributions

MIMG, AGC and JCDM conceived the study. MIMG designed the study, participated in the recruitment of patients, performed the statistical analysis, interpreted the data and drafted the manuscript. AGC participated in the study design, interpreted data and helped draft the manuscript. MGR, RMP and VPM participated in patient recruitment, data collection and technical support. All authors contributed to the critical review of the manuscript and approved the final manuscript.
Literatur
1.
Zurück zum Zitat Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006, 34: 1402–1407. 10.1097/01.CCM.0000215453.11735.06PubMedCrossRef Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006, 34: 1402–1407. 10.1097/01.CCM.0000215453.11735.06PubMedCrossRef
2.
Zurück zum Zitat Maizel J, Airapetian N, Lorne E, Tribouilloy C, Massy Z, Slama M: Diagnosis of central hypovolemia by using passive leg raising. Intensive Care Med 2007, 33: 1133–1138. 10.1007/s00134-007-0642-yPubMedCrossRef Maizel J, Airapetian N, Lorne E, Tribouilloy C, Massy Z, Slama M: Diagnosis of central hypovolemia by using passive leg raising. Intensive Care Med 2007, 33: 1133–1138. 10.1007/s00134-007-0642-yPubMedCrossRef
3.
Zurück zum Zitat Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL: Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med 2007, 33: 1125–1132. 10.1007/s00134-007-0646-7PubMedCrossRef Lamia B, Ochagavia A, Monnet X, Chemla D, Richard C, Teboul JL: Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity. Intensive Care Med 2007, 33: 1125–1132. 10.1007/s00134-007-0646-7PubMedCrossRef
4.
Zurück zum Zitat Monnet X, Teboul JL: Passive leg raising: keep it easy! Intensive Care Med 2010, 36: 1445. 10.1007/s00134-010-1900-yPubMedCrossRef Monnet X, Teboul JL: Passive leg raising: keep it easy! Intensive Care Med 2010, 36: 1445. 10.1007/s00134-010-1900-yPubMedCrossRef
6.
Zurück zum Zitat Monnet X, Teboul JL: Passive leg raising. Intensive Care Med 2008, 34: 659–663. 10.1007/s00134-008-0994-yPubMedCrossRef Monnet X, Teboul JL: Passive leg raising. Intensive Care Med 2008, 34: 659–663. 10.1007/s00134-008-0994-yPubMedCrossRef
7.
Zurück zum Zitat Preau S, Saulnier F, Dewavrin F, Durocher A, Chagnon JL: Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med 2010, 38: 819–825. 10.1097/CCM.0b013e3181c8fe7aPubMedCrossRef Preau S, Saulnier F, Dewavrin F, Durocher A, Chagnon JL: Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med 2010, 38: 819–825. 10.1097/CCM.0b013e3181c8fe7aPubMedCrossRef
8.
Zurück zum Zitat Biais M, Vidil L, Sarrabay P, Cottenceau V, Revel P, Sztark F: Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo/FloTrac device. Crit Care 2009, 13: R195. 10.1186/cc8195PubMedCentralPubMedCrossRef Biais M, Vidil L, Sarrabay P, Cottenceau V, Revel P, Sztark F: Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo/FloTrac device. Crit Care 2009, 13: R195. 10.1186/cc8195PubMedCentralPubMedCrossRef
9.
Zurück zum Zitat Jabot J, Teboul JL, Richard C, Monnet X: Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med 2009, 35: 85–90. 10.1007/s00134-008-1293-3PubMedCrossRef Jabot J, Teboul JL, Richard C, Monnet X: Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med 2009, 35: 85–90. 10.1007/s00134-008-1293-3PubMedCrossRef
10.
Zurück zum Zitat Benomar B, Ouattara A, Estagnasie P, Brusset A, Squara P: Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med 2010, 36: 1875–1881. 10.1007/s00134-010-1990-6PubMedCrossRef Benomar B, Ouattara A, Estagnasie P, Brusset A, Squara P: Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med 2010, 36: 1875–1881. 10.1007/s00134-010-1990-6PubMedCrossRef
11.
Zurück zum Zitat Lafanechere A, Pene F, Goulenok C, Delahaye A, Mallet V, Choukroun G, Chiche JD, Mira JP, Cariou A: Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients. Crit Care 2006, 10: R132. 10.1186/cc5044PubMedCentralPubMedCrossRef Lafanechere A, Pene F, Goulenok C, Delahaye A, Mallet V, Choukroun G, Chiche JD, Mira JP, Cariou A: Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients. Crit Care 2006, 10: R132. 10.1186/cc5044PubMedCentralPubMedCrossRef
12.
Zurück zum Zitat Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H: The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med 2010, 38: 1824–1829. 10.1097/CCM.0b013e3181eb3c21PubMedCrossRef Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H: The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med 2010, 38: 1824–1829. 10.1097/CCM.0b013e3181eb3c21PubMedCrossRef
13.
Zurück zum Zitat Leigh MD, Jenkins LC, Belton MK, Lewis GB Jr: Continuous alveolar carbon dioxide analysis as a monitor of pulmonary blood flow. Anesthesiology 1957, 18: 878–882. 10.1097/00000542-195711000-00009PubMedCrossRef Leigh MD, Jenkins LC, Belton MK, Lewis GB Jr: Continuous alveolar carbon dioxide analysis as a monitor of pulmonary blood flow. Anesthesiology 1957, 18: 878–882. 10.1097/00000542-195711000-00009PubMedCrossRef
14.
Zurück zum Zitat Weil MH, Bisera J, Trevino RP, Rackow EC: Cardiac output and end-tidal carbon dioxide. Crit Care Med 1985, 13: 907–909. 10.1097/00003246-198511000-00011PubMedCrossRef Weil MH, Bisera J, Trevino RP, Rackow EC: Cardiac output and end-tidal carbon dioxide. Crit Care Med 1985, 13: 907–909. 10.1097/00003246-198511000-00011PubMedCrossRef
15.
Zurück zum Zitat Kolar M, Krizmaric M, Klemen P, Grmec S: Partial pressure of end-tidal carbon dioxide successful predicts cardiopulmonary resuscitation in the field: a prospective observational study. Crit Care 2008, 12: R115. 10.1186/cc7009PubMedCentralPubMedCrossRef Kolar M, Krizmaric M, Klemen P, Grmec S: Partial pressure of end-tidal carbon dioxide successful predicts cardiopulmonary resuscitation in the field: a prospective observational study. Crit Care 2008, 12: R115. 10.1186/cc7009PubMedCentralPubMedCrossRef
16.
Zurück zum Zitat Pernat A, Weil MH, Sun S, Tang W: Stroke volumes and end-tidal carbon dioxide generated by precordial compression during ventricular fibrillation. Crit Care Med 2003, 31: 1819–1823. 10.1097/01.CCM.0000069538.12447.82PubMedCrossRef Pernat A, Weil MH, Sun S, Tang W: Stroke volumes and end-tidal carbon dioxide generated by precordial compression during ventricular fibrillation. Crit Care Med 2003, 31: 1819–1823. 10.1097/01.CCM.0000069538.12447.82PubMedCrossRef
17.
Zurück zum Zitat West JB: State of the art: ventilation-perfusion relationships. Am Rev Respir Dis 1977, 116: 919–943.PubMed West JB: State of the art: ventilation-perfusion relationships. Am Rev Respir Dis 1977, 116: 919–943.PubMed
18.
Zurück zum Zitat Ornato JP, Garnett AR, Glauser FL: Relationship between cardiac output and the end-tidal carbon dioxide tension. Ann Emerg Med 1990, 19: 1104–1106. 10.1016/S0196-0644(05)81512-4PubMedCrossRef Ornato JP, Garnett AR, Glauser FL: Relationship between cardiac output and the end-tidal carbon dioxide tension. Ann Emerg Med 1990, 19: 1104–1106. 10.1016/S0196-0644(05)81512-4PubMedCrossRef
19.
Zurück zum Zitat Dubin A, Silva CGC, Valli J, Faruna O, Estenssoro E, Mordujovich P: End-tidal CO2 pressure in the monitoring of cardiac output during canine hemorrhagic shock. J Crit Care 1990, 5: 42–46. 10.1016/0883-9441(90)90008-WCrossRef Dubin A, Silva CGC, Valli J, Faruna O, Estenssoro E, Mordujovich P: End-tidal CO2 pressure in the monitoring of cardiac output during canine hemorrhagic shock. J Crit Care 1990, 5: 42–46. 10.1016/0883-9441(90)90008-WCrossRef
20.
Zurück zum Zitat Jin X, Weil MH, Tang W, Povoas H, Pernat A, Xie J, Bisera J: End-tidal carbon dioxide as a noninvasive indicator of cardiac index during circulatory shock. Crit Care Med 2000, 28: 2415–2419.PubMedCrossRef Jin X, Weil MH, Tang W, Povoas H, Pernat A, Xie J, Bisera J: End-tidal carbon dioxide as a noninvasive indicator of cardiac index during circulatory shock. Crit Care Med 2000, 28: 2415–2419.PubMedCrossRef
21.
Zurück zum Zitat Dubin A, Murias G, Estenssoro E, Canales H, Sottile P, Badie J, Baran M, Rossi S, Laporte M, Palizas F, Giampieri J, Mediavilla D, Vacca E, Botta D: End-tidal CO2 pressure determinants during hemorrhagic shock. Intensive Care Med 2000, 26: 1619–1623. 10.1007/s001340000669PubMedCrossRef Dubin A, Murias G, Estenssoro E, Canales H, Sottile P, Badie J, Baran M, Rossi S, Laporte M, Palizas F, Giampieri J, Mediavilla D, Vacca E, Botta D: End-tidal CO2 pressure determinants during hemorrhagic shock. Intensive Care Med 2000, 26: 1619–1623. 10.1007/s001340000669PubMedCrossRef
22.
Zurück zum Zitat Isserles SA, Breen PH: Can changes in end-tidal PCO2 measure changes in cardiac output? Anesth Analg 1991, 73: 808–814.PubMedCrossRef Isserles SA, Breen PH: Can changes in end-tidal PCO2 measure changes in cardiac output? Anesth Analg 1991, 73: 808–814.PubMedCrossRef
23.
Zurück zum Zitat Guzman JA, Lacoma FJ, Najar A, Kruse JA: End-tidal partial pressure of carbon dioxide as a noninvasive indicator of systemic oxygen supply dependency during hemorrhagic shock and resuscitation. Shock 1997, 8: 427–431. 10.1097/00024382-199712000-00006PubMedCrossRef Guzman JA, Lacoma FJ, Najar A, Kruse JA: End-tidal partial pressure of carbon dioxide as a noninvasive indicator of systemic oxygen supply dependency during hemorrhagic shock and resuscitation. Shock 1997, 8: 427–431. 10.1097/00024382-199712000-00006PubMedCrossRef
24.
Zurück zum Zitat Idris AH, Staples ED, O'Brien DJ, Melker RJ, Rush WJ, Del Duca KD, Falk JL: End-tidal carbon dioxide during extremely low cardiac output. Ann Emerg Med 1994, 23: 568–572. 10.1016/S0196-0644(94)70080-XPubMedCrossRef Idris AH, Staples ED, O'Brien DJ, Melker RJ, Rush WJ, Del Duca KD, Falk JL: End-tidal carbon dioxide during extremely low cardiac output. Ann Emerg Med 1994, 23: 568–572. 10.1016/S0196-0644(94)70080-XPubMedCrossRef
25.
Zurück zum Zitat Shibutani K, Muraoka M, Shirasaki S, Kubal K, Sanchala VT, Gupte P: Do changes in end-tidal PCO2 quantitatively reflect changes in cardiac output? Anesth Analg 1994, 79: 829–833.PubMedCrossRef Shibutani K, Muraoka M, Shirasaki S, Kubal K, Sanchala VT, Gupte P: Do changes in end-tidal PCO2 quantitatively reflect changes in cardiac output? Anesth Analg 1994, 79: 829–833.PubMedCrossRef
26.
Zurück zum Zitat Wahba RW, Tessler MJ, Beique F, Kleiman SJ: Changes in PCO2 with acute changes in cardiac index. Can J Anaesth 1996, 43: 243–245. 10.1007/BF03011742PubMedCrossRef Wahba RW, Tessler MJ, Beique F, Kleiman SJ: Changes in PCO2 with acute changes in cardiac index. Can J Anaesth 1996, 43: 243–245. 10.1007/BF03011742PubMedCrossRef
27.
Zurück zum Zitat McLellan S, Walsh T, Burdess A, Lee A: Comparison between the Datex-Ohmeda M-COVX metabolic monitor and the Deltatrac II in mechanically ventilated patients. Intensive Care Med 2002, 28: 870–876. 10.1007/s00134-002-1323-5PubMedCrossRef McLellan S, Walsh T, Burdess A, Lee A: Comparison between the Datex-Ohmeda M-COVX metabolic monitor and the Deltatrac II in mechanically ventilated patients. Intensive Care Med 2002, 28: 870–876. 10.1007/s00134-002-1323-5PubMedCrossRef
28.
Zurück zum Zitat Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM: Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies--with specific reference to the measurement of cardiac output. Crit Care 2009, 13: 201. 10.1186/cc7129PubMedCentralPubMedCrossRef Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM: Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies--with specific reference to the measurement of cardiac output. Crit Care 2009, 13: 201. 10.1186/cc7129PubMedCentralPubMedCrossRef
29.
Zurück zum Zitat Husted JA, Cook RJ, Farewell VT, Gladman DD: Methods for assessing responsiveness: a critical review and recommendations. J Clin Epidemiol 2000, 53: 459–468. 10.1016/S0895-4356(99)00206-1PubMedCrossRef Husted JA, Cook RJ, Farewell VT, Gladman DD: Methods for assessing responsiveness: a critical review and recommendations. J Clin Epidemiol 2000, 53: 459–468. 10.1016/S0895-4356(99)00206-1PubMedCrossRef
30.
Zurück zum Zitat Guyatt G, Walter S, Norman G: Measuring change over time: assessing the usefulness of evaluative instruments. J Chron Dis 1987, 40: 171–178. 10.1016/0021-9681(87)90069-5PubMedCrossRef Guyatt G, Walter S, Norman G: Measuring change over time: assessing the usefulness of evaluative instruments. J Chron Dis 1987, 40: 171–178. 10.1016/0021-9681(87)90069-5PubMedCrossRef
31.
Zurück zum Zitat King SL, Lim MS: The use of the oesophageal Doppler monitor in the intensive care unit. Crit Care Resusc 2004, 6: 113–122.PubMed King SL, Lim MS: The use of the oesophageal Doppler monitor in the intensive care unit. Crit Care Resusc 2004, 6: 113–122.PubMed
32.
Zurück zum Zitat Madan AK, UyBarreta VV, Aliabadi-Wahle S, Jesperson R, Hartz RS, Flint LM, Steinberg SM: Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients. J Trauma 1999, 46: 607–611. discussion 611–602 10.1097/00005373-199904000-00008PubMedCrossRef Madan AK, UyBarreta VV, Aliabadi-Wahle S, Jesperson R, Hartz RS, Flint LM, Steinberg SM: Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients. J Trauma 1999, 46: 607–611. discussion 611–602 10.1097/00005373-199904000-00008PubMedCrossRef
33.
Zurück zum Zitat Singer M, Allen MJ, Webb AR, Bennett ED: Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med 1991, 19: 1138–1145. 10.1097/00003246-199109000-00008PubMedCrossRef Singer M, Allen MJ, Webb AR, Bennett ED: Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects. Crit Care Med 1991, 19: 1138–1145. 10.1097/00003246-199109000-00008PubMedCrossRef
34.
Zurück zum Zitat Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M: Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010, 36: 1475–1483. 10.1007/s00134-010-1929-yPubMedCrossRef Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M: Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010, 36: 1475–1483. 10.1007/s00134-010-1929-yPubMedCrossRef
35.
Zurück zum Zitat Michard F, Teboul JL: Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002, 121: 2000–2008. 10.1378/chest.121.6.2000PubMedCrossRef Michard F, Teboul JL: Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002, 121: 2000–2008. 10.1378/chest.121.6.2000PubMedCrossRef
36.
Zurück zum Zitat Critchley LA, Lee A, Ho AM: A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010, 111: 1180–1192. 10.1213/ANE.0b013e3181f08a5bPubMedCrossRef Critchley LA, Lee A, Ho AM: A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010, 111: 1180–1192. 10.1213/ANE.0b013e3181f08a5bPubMedCrossRef
38.
Zurück zum Zitat Callaham M, Barton C: Prediction of outcome of cardiopulmonary resuscitation from end-tidal carbon dioxide concentration. Crit Care Med 1990, 18: 358–362. 10.1097/00003246-199004000-00002PubMedCrossRef Callaham M, Barton C: Prediction of outcome of cardiopulmonary resuscitation from end-tidal carbon dioxide concentration. Crit Care Med 1990, 18: 358–362. 10.1097/00003246-199004000-00002PubMedCrossRef
39.
Zurück zum Zitat Tyburski JG, Collinge JD, Wilson RF, Carlin AM, Albaran RG, Steffes CP: End-tidal CO2-derived values during emergency trauma surgery correlated with outcome: a prospective study. J Trauma 2002, 53: 738–743. 10.1097/00005373-200210000-00020PubMedCrossRef Tyburski JG, Collinge JD, Wilson RF, Carlin AM, Albaran RG, Steffes CP: End-tidal CO2-derived values during emergency trauma surgery correlated with outcome: a prospective study. J Trauma 2002, 53: 738–743. 10.1097/00005373-200210000-00020PubMedCrossRef
40.
Zurück zum Zitat Lucangelo U, Blanch L: Dead space. Intensive Care Med 2004, 30: 576–579. 10.1007/s00134-004-2194-8PubMedCrossRef Lucangelo U, Blanch L: Dead space. Intensive Care Med 2004, 30: 576–579. 10.1007/s00134-004-2194-8PubMedCrossRef
41.
Zurück zum Zitat Fougeres E, Teboul JL, Richard C, Osman D, Chemla D, Monnet X: Hemodynamic impact of a positive end-expiratory pressure setting in acute respiratory distress syndrome: Importance of the volume status. Crit Care Med 2010, 38: 802–807. 10.1097/CCM.0b013e3181c587fdPubMedCrossRef Fougeres E, Teboul JL, Richard C, Osman D, Chemla D, Monnet X: Hemodynamic impact of a positive end-expiratory pressure setting in acute respiratory distress syndrome: Importance of the volume status. Crit Care Med 2010, 38: 802–807. 10.1097/CCM.0b013e3181c587fdPubMedCrossRef
Metadaten
Titel
Non-invasive assessment of fluid responsiveness by changes in partial end-tidal CO2 pressure during a passive leg-raising maneuver
verfasst von
Manuel Ignacio Monge García
Anselmo Gil Cano
Manuel Gracia Romero
Rocío Monterroso Pintado
Virginia Pérez Madueño
Juan Carlos Díaz Monrové
Publikationsdatum
01.12.2012
Verlag
Springer Paris
Erschienen in
Annals of Intensive Care / Ausgabe 1/2012
Elektronische ISSN: 2110-5820
DOI
https://doi.org/10.1186/2110-5820-2-9

Weitere Artikel der Ausgabe 1/2012

Annals of Intensive Care 1/2012 Zur Ausgabe

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Delir bei kritisch Kranken – Antipsychotika versus Placebo

16.05.2024 Delir Nachrichten

Um die Langzeitfolgen eines Delirs bei kritisch Kranken zu mildern, wird vielerorts auf eine Akuttherapie mit Antipsychotika gesetzt. Eine US-amerikanische Forschungsgruppe äußert jetzt erhebliche Vorbehalte gegen dieses Vorgehen. Denn es gibt neue Daten zum Langzeiteffekt von Haloperidol bzw. Ziprasidon versus Placebo.

Eingreifen von Umstehenden rettet vor Erstickungstod

15.05.2024 Fremdkörperaspiration Nachrichten

Wer sich an einem Essensrest verschluckt und um Luft ringt, benötigt vor allem rasche Hilfe. Dass Umstehende nur in jedem zweiten Erstickungsnotfall bereit waren, diese zu leisten, ist das ernüchternde Ergebnis einer Beobachtungsstudie aus Japan. Doch es gibt auch eine gute Nachricht.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.