Abstract

Objective

To assess if digital breast tomosynthesis (DBT) is at least equal to digital spot compression view (DSCV).

Methods

Following institutional approval and written informed consent, both DBT and DSCV were obtained in women with a screening abnormality. The diagnostic accuracy of DBT and DSCV was evaluated by two radiologists of varying experience (Reader1 and Reader2).

Results

52 consecutive recalled women without calcification (mean age: 51 ± 12 years) underwent DSCV and DBT. Overall sensitivity was equal for both techniques (100% [95% CI, 91–100%] for DBT and 100% [95% CI, 91–100%] for DSCV). Overall specificity was higher for DBT (100% [95%CI, 91–100%]) than for DSCV (94% [95% CI, 91–100%]). Specificity for DSCV was higher for Reader1 (95% [95% CI, 91–100%]). Reader2 had lower values of specificity (92% [95% CI, 90–92%]). On DSCV, three and two false positives were recorded by Reader2 and Reader1, respectively. Overall, the area under the curve (AUC) was greater for DBT (AUC = 1) than for DSCV (AUC = 0.963). The mean difference between the two techniques was not significantly different (P = 0.43).

Conclusion

In this dataset, diagnostic accuracy of digital breast tomosynthesis is at least equal to that of digital spot compression.

Key Points

Digital spot compression views (DSCVs) are often needed in breast screening programmes.
Digital breast tomosynthesis (DBT) now offers an alternative to DSCV
In recalls without calcification, DBT was at least equally accurate as DSCVs
DBT has a lower mean glandular dose than DSCVs
Thus DBT has the potential to help reduce the recall rate.
Literatur
1.
Zurück zum Zitat Minog H, Tennant JC, Youker JE (1968) Coning and breast compression: an aid in mammographic diagnosis. Radiology 91:379–380 Minog H, Tennant JC, Youker JE (1968) Coning and breast compression: an aid in mammographic diagnosis. Radiology 91:379–380
2.
Zurück zum Zitat Berkowitz JE, Gatewood OM, Gayler BW (1989) Equivocal mammographic findings: evaluation with spot compression. Radiology 171:369–371PubMed Berkowitz JE, Gatewood OM, Gayler BW (1989) Equivocal mammographic findings: evaluation with spot compression. Radiology 171:369–371PubMed
3.
Zurück zum Zitat Sickles EA (1989) Combining spot-compression and other special views to maximize mammographic information. Radiology 173:571PubMed Sickles EA (1989) Combining spot-compression and other special views to maximize mammographic information. Radiology 173:571PubMed
4.
Zurück zum Zitat Heywang-Köbrunner SH, Dershaw DD, Schreer I (2001) Mammography. In: Diagnostic breast imaging: mammography, sonography, magnetic resonance imaging, and interventional procedures, 2nd enlarged and revised edn. Thieme, Stuttgart New York, pp 14–83. Heywang-Köbrunner SH, Dershaw DD, Schreer I (2001) Mammography. In: Diagnostic breast imaging: mammography, sonography, magnetic resonance imaging, and interventional procedures, 2nd enlarged and revised edn. Thieme, Stuttgart New York, pp 14–83.
5.
Zurück zum Zitat Harvey JA, Nicholson BT, Cohen MA (2008) Finding early invasive breast cancers: a practical approach. Radiology 248:61–76PubMedCrossRef Harvey JA, Nicholson BT, Cohen MA (2008) Finding early invasive breast cancers: a practical approach. Radiology 248:61–76PubMedCrossRef
6.
Zurück zum Zitat Gur D, Abrams GS, Chough DM et al (2009) Digital breast tomosynthesis: observer performance study. AJR Am J Roentgenol 193:586–591PubMedCrossRef Gur D, Abrams GS, Chough DM et al (2009) Digital breast tomosynthesis: observer performance study. AJR Am J Roentgenol 193:586–591PubMedCrossRef
7.
Zurück zum Zitat Poplack SP, Tosteson TD, Kogel CA, Nagy HM (2007) Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. Am J Roentgenol 189:616–623CrossRef Poplack SP, Tosteson TD, Kogel CA, Nagy HM (2007) Digital breast tomosynthesis: initial experience in 98 women with abnormal digital screening mammography. Am J Roentgenol 189:616–623CrossRef
8.
Zurück zum Zitat Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20:1545–1553PubMedCrossRef Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20:1545–1553PubMedCrossRef
9.
Zurück zum Zitat Giess CS, Keating DM, Osborne MP, Ng YY, Rosenblatt R (1998) Retroareolar breast carcinoma: clinical, imaging, and histopathologic features. Radiology 207:669–673PubMed Giess CS, Keating DM, Osborne MP, Ng YY, Rosenblatt R (1998) Retroareolar breast carcinoma: clinical, imaging, and histopathologic features. Radiology 207:669–673PubMed
10.
Zurück zum Zitat Spangler ML, Zuley ML, Sumkin JH et al (2011) Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. AJR Am J Roentgenol 196:320–324PubMedCrossRef Spangler ML, Zuley ML, Sumkin JH et al (2011) Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison. AJR Am J Roentgenol 196:320–324PubMedCrossRef
11.
Zurück zum Zitat Park JM, Franken EA Jr, Garg M, Fajardo LL, Niklason LT (2007) Breast tomosynthesis: present considerations and future applications. Radiographics 27:S231–S240PubMedCrossRef Park JM, Franken EA Jr, Garg M, Fajardo LL, Niklason LT (2007) Breast tomosynthesis: present considerations and future applications. Radiographics 27:S231–S240PubMedCrossRef
13.
Zurück zum Zitat Dance DR, Young KC, van Engen RE (2011) Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols. Phys Med Biol 56:453–471PubMedCrossRef Dance DR, Young KC, van Engen RE (2011) Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols. Phys Med Biol 56:453–471PubMedCrossRef
14.
Zurück zum Zitat Cavagnetto F, Bampi R, Calabrese M, Orlando B, Villa A, Taccini G (2011) Comparison of dose in digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM). Poster at ECR 2011. doi:10.1594/ecr2011/C-1997 Cavagnetto F, Bampi R, Calabrese M, Orlando B, Villa A, Taccini G (2011) Comparison of dose in digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM). Poster at ECR 2011. doi:10.​1594/​ecr2011/​C-1997
15.
Zurück zum Zitat Cavagnetto F, Bampi R, Calabrese M, Chiesa F, Taccini G (2011) The use of metal oxide semiconductor field effect transistor (MOSFET) in digital breast tomosynthesis. Poster at ECR 2011. doi:10.1594/ecr2011/C-1963 Cavagnetto F, Bampi R, Calabrese M, Chiesa F, Taccini G (2011) The use of metal oxide semiconductor field effect transistor (MOSFET) in digital breast tomosynthesis. Poster at ECR 2011. doi:10.​1594/​ecr2011/​C-1963
16.
Zurück zum Zitat American College of Radiology (2003) BI-RADS: mammography, 4th edn. In: Breast imaging reporting and data system: BI-RADS atlas. American College of Radiology, Reston American College of Radiology (2003) BI-RADS: mammography, 4th edn. In: Breast imaging reporting and data system: BI-RADS atlas. American College of Radiology, Reston
17.
Zurück zum Zitat American College of Radiology (2003) BI-RADS: ultrasound, 1st edn. In: Breast imaging reporting and data system: BI-RADS atlas. American College of Radiology, Reston, VA, USA American College of Radiology (2003) BI-RADS: ultrasound, 1st edn. In: Breast imaging reporting and data system: BI-RADS atlas. American College of Radiology, Reston, VA, USA
18.
Zurück zum Zitat Hakim CM, Chough DM, Ganott MA, Sumkin JH, Zuley ML, Gur D (2010) Digital breast tomosynthesis in the diagnostic environment: a subjective side-by-side review. AJR Am J Roentgenol 195:W172–176PubMedCrossRef Hakim CM, Chough DM, Ganott MA, Sumkin JH, Zuley ML, Gur D (2010) Digital breast tomosynthesis in the diagnostic environment: a subjective side-by-side review. AJR Am J Roentgenol 195:W172–176PubMedCrossRef
19.
Zurück zum Zitat Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20:1545–1553PubMedCrossRef Gennaro G, Toledano A, di Maggio C et al (2010) Digital breast tomosynthesis versus digital mammography: a clinical performance study. Eur Radiol 20:1545–1553PubMedCrossRef
20.
Zurück zum Zitat Teertstra HJ, Loo CE, van den Bosch MA et al (2010) Breast tomosynthesis in clinical practice: initial results. Eur Radiol 20:16–24PubMedCrossRef Teertstra HJ, Loo CE, van den Bosch MA et al (2010) Breast tomosynthesis in clinical practice: initial results. Eur Radiol 20:16–24PubMedCrossRef
Metadaten
Titel
One-to-one comparison between digital spot compression view and digital breast tomosynthesis
verfasst von
Alberto Tagliafico
Davide Astengo
Francesca Cavagnetto
Raffaella Rosasco
Giuseppe Rescinito
Francesco Monetti
Massimo Calabrese
Publikationsdatum
01.03.2012
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 3/2012
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-011-2305-1

Weitere Artikel der Ausgabe 3/2012

European Radiology 3/2012 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.