Background

Although intra-operative neuromonitoring (IONM) is widely used in thyroid surgery, the validity of the received IONM signals are still unknown.

Method

Prospective collection of data forms in 29 hospitals from 8,534 patients with 15,403 nerves at risk, who underwent surgery for benign and malignant goitre disorders between August 1999 and January 2001. IONM was performed by indirect stimulation via the vagal nerve and by direct recurrent laryngeal nerve (RLN) stimulation in 12,486 cases. IONM signals were compared with early (<14 days) and late (6 months) postoperative vocal cord function findings.

Results

The transient and permanent RLN palsy rate was 2.8% and 0.7%, respectively. Monitoring of the RLN function was significantly more reliable via the indirect IONM stimulation route than via the direct IONM stimulation route (specificity P<0.05). IONM by indirect stimulation via the vagal nerve reliably excluded postoperative, permanent, vocal cord palsy (specificity 97.6%, negative predictive value 99.6%). However, a changed IONM was insufficient to predict permanent RLN palsy (sensitivity 45.9%, positive predictive value 11.6%). IONM was not associated with increased general morbidity.

Conclusions

For intra-operative neuromonitoring, indirect stimulation of the RLN is superior to direct stimulation. An intact acoustic IONM signal is highly predictive of intact postoperative RLN function. When the IONM signal is abnormal or absent, a one-stage extensive thyroid resection should be performed only if the surgeon is absolutely convinced that the first RLN is not harmed or a total thyroidectomy is mandatory.
Literatur
1.
Zurück zum Zitat Seiler C, Glaser C, Wagner HE (1996) Thyroid gland surgery in an endemic region. World J Surg 20:593–597CrossRefPubMed Seiler C, Glaser C, Wagner HE (1996) Thyroid gland surgery in an endemic region. World J Surg 20:593–597CrossRefPubMed
2.
Zurück zum Zitat Lahey FH (1938) Routine dissection and demonstration of the recurrent laryngeal nerve in subtotal thyroidectomy. Surg Gynecol Obstet 66:775 Lahey FH (1938) Routine dissection and demonstration of the recurrent laryngeal nerve in subtotal thyroidectomy. Surg Gynecol Obstet 66:775
3.
Zurück zum Zitat Hermann M, Alk G, Roka R, Glaser K, Freissmuth M (2002) Laryngeal recurrent nerve injury in surgery for benign thyroid disease: effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk. Ann Surg 235:261–268CrossRefPubMed Hermann M, Alk G, Roka R, Glaser K, Freissmuth M (2002) Laryngeal recurrent nerve injury in surgery for benign thyroid disease: effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk. Ann Surg 235:261–268CrossRefPubMed
4.
Zurück zum Zitat Zornig C, de Heer K, Koenecke S, et al (1989) Darstellung des Nervus recurrens bei Schilddrüsenoperationen—Standortbestimmung. Chirurg 60:44–48PubMed Zornig C, de Heer K, Koenecke S, et al (1989) Darstellung des Nervus recurrens bei Schilddrüsenoperationen—Standortbestimmung. Chirurg 60:44–48PubMed
5.
Zurück zum Zitat Reeve TS, Delbridge L, Cohen A, Crummer P (1987) Total thyroidectomy: the preferred option for multinodular goiter. Ann Surg 206:782–786PubMed Reeve TS, Delbridge L, Cohen A, Crummer P (1987) Total thyroidectomy: the preferred option for multinodular goiter. Ann Surg 206:782–786PubMed
6.
Zurück zum Zitat Thomusch O, Machens A, Sekulla C, et al (2000) Multivariate analysis of risk factors for postoperative complications in benign goiter surgery. World J Surg 24:1335–1341PubMed Thomusch O, Machens A, Sekulla C, et al (2000) Multivariate analysis of risk factors for postoperative complications in benign goiter surgery. World J Surg 24:1335–1341PubMed
7.
Zurück zum Zitat Lahey FH (1944) Exposure of the recurrent laryngeal nerve in thyroid operation. Surg Gynecol Obstet 78:239–244 Lahey FH (1944) Exposure of the recurrent laryngeal nerve in thyroid operation. Surg Gynecol Obstet 78:239–244
8.
Zurück zum Zitat Thomusch O, Dralle H (2000) Endocrine surgery and evidence-based surgery. Chirurg 71:635–645CrossRefPubMed Thomusch O, Dralle H (2000) Endocrine surgery and evidence-based surgery. Chirurg 71:635–645CrossRefPubMed
9.
Zurück zum Zitat Djohan RS, Rodriguez HE, Connolly MM, et al (2000) Intraoperative monitoring of recurrent laryngeal nerve function. Am Surg 66:595–597PubMed Djohan RS, Rodriguez HE, Connolly MM, et al (2000) Intraoperative monitoring of recurrent laryngeal nerve function. Am Surg 66:595–597PubMed
10.
Zurück zum Zitat Thomusch O, Sekulla C, Walls G, Machens A, Dralle H (2002) Intraoperative neuromonitoring in surgery for benign goiter: decreased rate of recurrent laryngeal nerve palsy after subtotal thyroidectomy. Am J Surg 183:674–679CrossRef Thomusch O, Sekulla C, Walls G, Machens A, Dralle H (2002) Intraoperative neuromonitoring in surgery for benign goiter: decreased rate of recurrent laryngeal nerve palsy after subtotal thyroidectomy. Am J Surg 183:674–679CrossRef
11.
Zurück zum Zitat Timmermann W, Dralle H, Hamelmann W, et al (2002) Does intraoperative nerve monitoring reduce the rate of recurrent laryngeal nerve palsies during thyroid surgery? Zentralbl Chir 127:395–399CrossRefPubMed Timmermann W, Dralle H, Hamelmann W, et al (2002) Does intraoperative nerve monitoring reduce the rate of recurrent laryngeal nerve palsies during thyroid surgery? Zentralbl Chir 127:395–399CrossRefPubMed
12.
Zurück zum Zitat Hamelmann W, Meyer T, Timm S, Timmermann W (2002) A critical estimation of intraoperative neuromonitoring (IONM) in thyroid surgery. Zentralbl Chir 127:409–413CrossRefPubMed Hamelmann W, Meyer T, Timm S, Timmermann W (2002) A critical estimation of intraoperative neuromonitoring (IONM) in thyroid surgery. Zentralbl Chir 127:409–413CrossRefPubMed
13.
Zurück zum Zitat Hvidegaard T, Vase P, Jorgensen K, Blichert-Toft M (1983) Identification and functional recording of the recurrent nerve by electrical stimulation during neck surgery. Laryngoscope 93:370–373PubMed Hvidegaard T, Vase P, Jorgensen K, Blichert-Toft M (1983) Identification and functional recording of the recurrent nerve by electrical stimulation during neck surgery. Laryngoscope 93:370–373PubMed
14.
Zurück zum Zitat Brennan J, Moore EJ, Shuler KJ (2001) Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy, and parotidectomy. Otolaryngol Head Neck Surg 124:537–543CrossRefPubMed Brennan J, Moore EJ, Shuler KJ (2001) Prospective analysis of the efficacy of continuous intraoperative nerve monitoring during thyroidectomy, parathyroidectomy, and parotidectomy. Otolaryngol Head Neck Surg 124:537–543CrossRefPubMed
15.
Zurück zum Zitat Flisberg K, Lindholm T (1970) Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol 263:63–67 Flisberg K, Lindholm T (1970) Electrical stimulation of the human recurrent laryngeal nerve during thyroid operation. Acta Otolaryngol 263:63–67
16.
Zurück zum Zitat Maloney RW, Murcek BW, Steehler KW, et al (1994) A new method for intraoperative recurrent laryngeal nerve monitoring. Ear Nose Throat 73:30–33 Maloney RW, Murcek BW, Steehler KW, et al (1994) A new method for intraoperative recurrent laryngeal nerve monitoring. Ear Nose Throat 73:30–33
17.
Zurück zum Zitat Rice DH, Cone-Wesson B (1991) Intraoperative recurrent laryngeal nerve monitoring. Otolaryngol Head Neck Surg 105:372–375PubMed Rice DH, Cone-Wesson B (1991) Intraoperative recurrent laryngeal nerve monitoring. Otolaryngol Head Neck Surg 105:372–375PubMed
18.
Zurück zum Zitat Horn D, Rötzscher VM (1999) Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: experience with an intralaryngeal surface electrode. Langenbecks Arch Surg 384:392–395CrossRefPubMed Horn D, Rötzscher VM (1999) Intraoperative electromyogram monitoring of the recurrent laryngeal nerve: experience with an intralaryngeal surface electrode. Langenbecks Arch Surg 384:392–395CrossRefPubMed
19.
Zurück zum Zitat Kienast A, Richter C, Neumann HJ (1998) Intraoperative neuromonitoring of the recurrent laryngeal nerve—a routine procedure during thyroid surgery. Langenbecks Arch Chir Suppl II:1058–1060 Kienast A, Richter C, Neumann HJ (1998) Intraoperative neuromonitoring of the recurrent laryngeal nerve—a routine procedure during thyroid surgery. Langenbecks Arch Chir Suppl II:1058–1060
20.
Zurück zum Zitat Tschopp K, Probst R (1994) New aspects in the surgery of the thyroid gland with intraoperative neuromonitoring of the recurrent laryngeal nerve. Laryngorhinootologie 73:568–572PubMed Tschopp K, Probst R (1994) New aspects in the surgery of the thyroid gland with intraoperative neuromonitoring of the recurrent laryngeal nerve. Laryngorhinootologie 73:568–572PubMed
21.
Zurück zum Zitat Kunath M, Hussock J, Marusch F, Horschig P, Gastinger I (1999) Identification of the recurrent laryngeal nerve by intraoperative neuromonitoring. Zentralbl Chir 124:641–645PubMed Kunath M, Hussock J, Marusch F, Horschig P, Gastinger I (1999) Identification of the recurrent laryngeal nerve by intraoperative neuromonitoring. Zentralbl Chir 124:641–645PubMed
22.
Zurück zum Zitat Mishra A, Agarwal A, Agarwal G, Mishra SK (2001) Total thyroidectomy for benign thyroid disorders in an endemic region. World J Surg 25:307–310PubMed Mishra A, Agarwal A, Agarwal G, Mishra SK (2001) Total thyroidectomy for benign thyroid disorders in an endemic region. World J Surg 25:307–310PubMed
23.
Zurück zum Zitat Al-Suliman NN, Ryttov NF, Qvist N, Blichert-Toft M, Graversen HP (1997) Experience in a specialist thyroid surgery unit: a demographic study, surgical complications, and outcome. Eur J Surg 163:13–20PubMed Al-Suliman NN, Ryttov NF, Qvist N, Blichert-Toft M, Graversen HP (1997) Experience in a specialist thyroid surgery unit: a demographic study, surgical complications, and outcome. Eur J Surg 163:13–20PubMed
24.
Zurück zum Zitat Nielsen TR, Andreassen UK, Brown CL, Balle VH, Thomsen J (1998) Microsurgical technique in thyroid surgery—a 10 year experience. J Laryngol Otol 112:556–560PubMed Nielsen TR, Andreassen UK, Brown CL, Balle VH, Thomsen J (1998) Microsurgical technique in thyroid surgery—a 10 year experience. J Laryngol Otol 112:556–560PubMed
25.
Zurück zum Zitat Jatzko GR, Lisborg PH, Müller MG, Wette VM (1994) Recurrent nerve palsy after thyroid operations—principal nerve identification and literature review. Surgery 115:139–144PubMed Jatzko GR, Lisborg PH, Müller MG, Wette VM (1994) Recurrent nerve palsy after thyroid operations—principal nerve identification and literature review. Surgery 115:139–144PubMed
Metadaten
Titel
Validity of intra-operative neuromonitoring signals in thyroid surgery
verfasst von
Oliver Thomusch
Carsten Sekulla
Andreas Machens
Hans-Jürgen Neumann
Wolfgang Timmermann
Henning Dralle
Publikationsdatum
01.11.2004
Verlag
Springer-Verlag
Erschienen in
Langenbeck's Archives of Surgery / Ausgabe 6/2004
Print ISSN: 1435-2443
Elektronische ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-003-0444-9

Weitere Artikel der Ausgabe 6/2004

Langenbeck's Archives of Surgery 6/2004 Zur Ausgabe

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.