Abstract

Background: The aim of this study is to gain insight into the problems encountered by the medical team related to products used for minimally invasive surgery.Methods: An inventory was made of the problems encountered during 12 endoscopic operations performed in one city hospital (Eindhoven, the Netherlands). After the observation, a questionnaire was distributed to all medical staff involved. Results: All categories of personnel had physical, perceptional, and cognitive problems, especially surgeons, residents, and the sterile operation nurse. The main causes were the positioning of apparatus and staff, work clothing, and the limited reach of apparatus and/or instruments. Of the questionnaires, 80% were returned: 50% of the medical staff experienced perceptional problems and 63% had physical discomfort during the surgical procedure. Conclusion: The diversity of problems observed and/or reported by the staff during minimally invasive surgery decrease the comfort, efficiency, and safety of the operating-room work environment. Therefore, a new design approach is needed for MIS products in order to address the problems that occur with the current equipment.
Literatur
1.
Zurück zum Zitat Berguer, R 1997The application of ergonomics in the work environment of general surgeons.Rev Environ Health1299106PubMed Berguer, R 1997The application of ergonomics in the work environment of general surgeons.Rev Environ Health1299106PubMed
2.
Zurück zum Zitat Berguer, R 1998Surgical technology and the ergonomics of laparoscopic instruments.Surg Endosc12458462CrossRefPubMed Berguer, R 1998Surgical technology and the ergonomics of laparoscopic instruments.Surg Endosc12458462CrossRefPubMed
3.
Zurück zum Zitat Berguer, R, Gerber, S, Kilpatrick, G, Beckley, D 1998An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper.Surg Endosc12805808CrossRefPubMed Berguer, R, Gerber, S, Kilpatrick, G, Beckley, D 1998An ergonomic comparison of in-line vs pistol-grip handle configuration in a laparoscopic grasper.Surg Endosc12805808CrossRefPubMed
4.
Zurück zum Zitat Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgery.Surg Endosc13466468CrossRefPubMed Berguer, R, Forkey, DL, Smith, WD 1999Ergonomic problems associated with laparoscopic surgery.Surg Endosc13466468CrossRefPubMed
5.
Zurück zum Zitat Berguer, R, Gerber, S, Kilpatrick, G, Remler, M, Beckley, D 1999A comparison of forearm and thumb muscle electromyographic responses to the use of laparoscopic instruments with either a finger grasp or a palm grasp.Ergonomics4216341645CrossRefPubMed Berguer, R, Gerber, S, Kilpatrick, G, Remler, M, Beckley, D 1999A comparison of forearm and thumb muscle electromyographic responses to the use of laparoscopic instruments with either a finger grasp or a palm grasp.Ergonomics4216341645CrossRefPubMed
6.
Zurück zum Zitat den Boer, KT, de Jong, T, Dankelman, J, Gouma, DJ 2001Problems with laparoscopic instruments: opinion of experts.J Laparoendosc Adv Surg Tech A11149155CrossRefPubMed den Boer, KT, de Jong, T, Dankelman, J, Gouma, DJ 2001Problems with laparoscopic instruments: opinion of experts.J Laparoendosc Adv Surg Tech A11149155CrossRefPubMed
7.
Zurück zum Zitat Goossens, RHM, Van Veelen, MA 2001Assessment of ergonomics in laparoscopic surgery.Min Invas Ther Allied Technol10l75179CrossRef Goossens, RHM, Van Veelen, MA 2001Assessment of ergonomics in laparoscopic surgery.Min Invas Ther Allied Technol10l75179CrossRef
8.
Zurück zum Zitat Hanna, GB, Shimi, SM, Cuschieri, A 1998Task performance in endoscopic surgery is influenced by location of the image display.Ann Surg227481484CrossRefPubMed Hanna, GB, Shimi, SM, Cuschieri, A 1998Task performance in endoscopic surgery is influenced by location of the image display.Ann Surg227481484CrossRefPubMed
9.
Zurück zum Zitat Matern, U, Eichenlaub, M, Waller, P, Ruckauer, K 1999MIS instruments. An experimental comparison of various ergonomic handles and their design.Surg Endosc13756762CrossRefPubMed Matern, U, Eichenlaub, M, Waller, P, Ruckauer, K 1999MIS instruments. An experimental comparison of various ergonomic handles and their design.Surg Endosc13756762CrossRefPubMed
10.
Zurück zum Zitat Matern, U, Waller, P 1999Instruments for minimally invasive surgery: principles of ergonomic handles.Surg Endosc13174182CrossRefPubMed Matern, U, Waller, P 1999Instruments for minimally invasive surgery: principles of ergonomic handles.Surg Endosc13174182CrossRefPubMed
11.
Zurück zum Zitat Patkin, M 2000History of ergonomy in surgery.Bruch, HPKockerling, FBouchard, RSchuss-Pass, C eds. New aspects of high technology in medicine.Monduzzi EditoreHanover, Germany239246 Patkin, M 2000History of ergonomy in surgery.Bruch, HPKockerling, FBouchard, RSchuss-Pass, C eds. New aspects of high technology in medicine.Monduzzi EditoreHanover, Germany239246
12.
Zurück zum Zitat Sanders, MS, McCormick, EJ 1993Human Factors in Engineering and Design.McGraw-Hill Book CompanyNew York Sanders, MS, McCormick, EJ 1993Human Factors in Engineering and Design.McGraw-Hill Book CompanyNew York
13.
Zurück zum Zitat Schurr, MO, Buess, G 1995OREST II—ergonomic workplace and systems platform for endoscopic technologies.Endosc Surg Allied Technol4193198PubMed Schurr, MO, Buess, G 1995OREST II—ergonomic workplace and systems platform for endoscopic technologies.Endosc Surg Allied Technol4193198PubMed
14.
Zurück zum Zitat Schurr, MO, Buess, GF, Wieth, F, Saile, HJ, Botsch, M 1999Ergonomic surgeon’s chair for use during minimally invasive surgery.Surg Laparosc Endosc Percutan Tech9244247CrossRefPubMed Schurr, MO, Buess, GF, Wieth, F, Saile, HJ, Botsch, M 1999Ergonomic surgeon’s chair for use during minimally invasive surgery.Surg Laparosc Endosc Percutan Tech9244247CrossRefPubMed
15.
Zurück zum Zitat Van Veelen, MA, Meijer, DW 1999Ergonomics and design of laparoscopic instruments: results of a survey among laparoscopic surgeons.J Laparoendosc Adv Surg Tech A9481489PubMed Van Veelen, MA, Meijer, DW 1999Ergonomics and design of laparoscopic instruments: results of a survey among laparoscopic surgeons.J Laparoendosc Adv Surg Tech A9481489PubMed
16.
Zurück zum Zitat Van Veelen, MA, Meijer, DW, Goossens, RHM, Snijders, CJ 2001New ergonomic design criteria for handles of laparoscopic dissection forceps.J Laparoendosc Adv Surg Tech A111726CrossRefPubMed Van Veelen, MA, Meijer, DW, Goossens, RHM, Snijders, CJ 2001New ergonomic design criteria for handles of laparoscopic dissection forceps.J Laparoendosc Adv Surg Tech A111726CrossRefPubMed
17.
Zurück zum Zitat Van Veelen, MA, Kazemier, G, Koopman, J, Goossens, RH, Meijer, DW 2002Assessment of the ergonomically optimal operating surface height for laparoscopic surgery.J Laparoendosc Adv Surg Tech A124752CrossRefPubMed Van Veelen, MA, Kazemier, G, Koopman, J, Goossens, RH, Meijer, DW 2002Assessment of the ergonomically optimal operating surface height for laparoscopic surgery.J Laparoendosc Adv Surg Tech A124752CrossRefPubMed
18.
Zurück zum Zitat Van Veelen, MA, Jakimowicz, JJ, Goossens, RH, Meijer, DW, Bussmann, JB 2002Evaluation of the usability of two types of image display systems, during laparoscopy.Surg Endosc16674678CrossRefPubMed Van Veelen, MA, Jakimowicz, JJ, Goossens, RH, Meijer, DW, Bussmann, JB 2002Evaluation of the usability of two types of image display systems, during laparoscopy.Surg Endosc16674678CrossRefPubMed
19.
Zurück zum Zitat Van Veelen, MA, Meijer, DW, Goossens, RH, Snijders, CJ, Jakimowicz, JJ 2002Improved usability of a new handle design for laparoscopic dissection forceps.Surg Endosc16201207CrossRefPubMed Van Veelen, MA, Meijer, DW, Goossens, RH, Snijders, CJ, Jakimowicz, JJ 2002Improved usability of a new handle design for laparoscopic dissection forceps.Surg Endosc16201207CrossRefPubMed
Metadaten
Titel
Ergonomic problems encountered by the medical team related to products used for minimally invasive surgery
verfasst von
M. A. van Veelen
E. A. L. Nederlof
R. H. M. Goossens
C. J. Schot
J. J. Jakimowicz
Publikationsdatum
01.07.2003
Erschienen in
Surgical Endoscopy / Ausgabe 7/2003
Print ISSN: 0930-2794
Elektronische ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-002-9105-2

Weitere Artikel der Ausgabe 7/2003

Surgical Endoscopy 7/2003 Zur Ausgabe

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.