Background

The Echelon circular™ powered stapler (ECP stapler) obviates the need for manual firing of conventional circular staplers during the construction of a colorectal anastomosis, but has not been evaluated clinically. The aim of this study was to perform a clinical evaluation of this stapler.

Methods

A retrospective review of the initial clinical experience of a single surgeon using the ECP stapler for left-sided colorectal anastomosis construction during elective colorectal resections for benign and malignant disease was conducted by analyzing results from a prospectively maintained study database. Additionally, four attending colorectal and/or general surgeons who had performed ≥ 5 colorectal operations with the ECP stapler were invited to complete an anonymous online survey to subjectively assess the user experience with the device. Statistical analysis was conducted using Microsoft Excel Version 15.33.

Results

Seventeen patients underwent left-sided anastomotic reconstruction using the ECP stapler. All donuts (proximal and distal) were intact. Anastomotic integrity was evaluated using the air-leak test utilizing flexible video sigmoidoscopy. No leaks were observed, although one patient (5.9%) developed a postoperative pelvic abscess. The anonymous survey was completed by all four surgeons. Subjective evaluation of the ECP stapler suggests that the overall stapling quality, overall device ease-of-use, and the overall perception of anastomotic quality as above average when compared to manual ‘end-to-end anastomosis’ (EEA) stapling devices.

Conclusions

In an initial clinical evaluation of the ECP stapler, the safety and ease-of-use of the device appears to be satisfactory. Powered stapling and the design of ‘3D stapling’ may provide advantages over manual systems, and may improve the construction quality of left-sided colorectal anastomosis.
Literatur
1.
Zurück zum Zitat Ravitch MM, Brown IW, Daviglus GF (1959) Experimental and clinical use of the Soviet bronchus stapling instrument. Surgery 46:97–108PubMed Ravitch MM, Brown IW, Daviglus GF (1959) Experimental and clinical use of the Soviet bronchus stapling instrument. Surgery 46:97–108PubMed
2.
Zurück zum Zitat Ravitch MM, Steichen FM, Fishbein RH (1964) Clinical experiences with the Soviet mechanical bronchus stapler (UKB-25). J Thorac Cardiovasc Surg 47:446–454CrossRef Ravitch MM, Steichen FM, Fishbein RH (1964) Clinical experiences with the Soviet mechanical bronchus stapler (UKB-25). J Thorac Cardiovasc Surg 47:446–454CrossRef
4.
Zurück zum Zitat Ravitch MM, Steichen FM (1972) Technics of staple suturing in the gastrointestinal tract. Ann Surg 175:815–836CrossRef Ravitch MM, Steichen FM (1972) Technics of staple suturing in the gastrointestinal tract. Ann Surg 175:815–836CrossRef
5.
Zurück zum Zitat Fain S, Patin CS, Morgenstern L (1975) Use of a mechanical suturing apparatus in low colorectal anastomosis. Arch Surg 110:1079–1082CrossRef Fain S, Patin CS, Morgenstern L (1975) Use of a mechanical suturing apparatus in low colorectal anastomosis. Arch Surg 110:1079–1082CrossRef
6.
Zurück zum Zitat Ravitch MM, Steichen FM (1979) A stapling instrument for end to- end inverting anastomoses in the gastrointestinal tract. Ann Surg 189:791–797CrossRef Ravitch MM, Steichen FM (1979) A stapling instrument for end to- end inverting anastomoses in the gastrointestinal tract. Ann Surg 189:791–797CrossRef
8.
Zurück zum Zitat Rojatkar P, Henderson CE, Hall S, Jenkins SA, Paulin-Curlee GG, Clymer JW, Nagle DA (2017) A novel powered circular stapler designed for creating secure anastomoses. Med Devices Diagn Eng 2:94–100CrossRef Rojatkar P, Henderson CE, Hall S, Jenkins SA, Paulin-Curlee GG, Clymer JW, Nagle DA (2017) A novel powered circular stapler designed for creating secure anastomoses. Med Devices Diagn Eng 2:94–100CrossRef
11.
Zurück zum Zitat Berguer R, Hreljac A (2004) The relationship between hand size and difficulty using surgical instruments: a survey of 726 laparoscopic surgeons. Surg Endosc 18(3):508–512CrossRef Berguer R, Hreljac A (2004) The relationship between hand size and difficulty using surgical instruments: a survey of 726 laparoscopic surgeons. Surg Endosc 18(3):508–512CrossRef
12.
Zurück zum Zitat Adams DM, Fenton SJ, Schirmer BD et al (2008) One size does not fit all: current disposable laparoscopic devices do not fit the needs of female laparoscopic surgeons. Surg Endosc 22(10):2310–2313CrossRef Adams DM, Fenton SJ, Schirmer BD et al (2008) One size does not fit all: current disposable laparoscopic devices do not fit the needs of female laparoscopic surgeons. Surg Endosc 22(10):2310–2313CrossRef
13.
Zurück zum Zitat Sutton E, Irvin M, Zeigler C et al (2014) The ergonomics of women in surgery. Surg Endosc 28(4):1051–1055CrossRef Sutton E, Irvin M, Zeigler C et al (2014) The ergonomics of women in surgery. Surg Endosc 28(4):1051–1055CrossRef
14.
Zurück zum Zitat Aitchison LP, Cui CK, Arnold A et al (2016) The ergonomics of laparoscopic surgery: a quantitative study of the time and motion of laparoscopic surgeons in live surgical environments. Surg Endosc 30(11):5068–5076CrossRef Aitchison LP, Cui CK, Arnold A et al (2016) The ergonomics of laparoscopic surgery: a quantitative study of the time and motion of laparoscopic surgeons in live surgical environments. Surg Endosc 30(11):5068–5076CrossRef
15.
Zurück zum Zitat Miller DL, Roy S, Kassis ES, Yadalam S, Ramisetti S, Johnston SS (2018) Impact of powered and tissue-specific endoscopic stapling technology on clinical and economic outcomes of video-assisted thoracic surgery lobectomy procedures: a retrospective, observational study. Adv Ther 35(5):707–723CrossRef Miller DL, Roy S, Kassis ES, Yadalam S, Ramisetti S, Johnston SS (2018) Impact of powered and tissue-specific endoscopic stapling technology on clinical and economic outcomes of video-assisted thoracic surgery lobectomy procedures: a retrospective, observational study. Adv Ther 35(5):707–723CrossRef
Metadaten
Titel
Initial clinical experience with a powered circular stapler for colorectal anastomosis
verfasst von
S. Atallah
S. Kural
N. Banda
A. Banda
F. Bawaney
F. Cabral
V. Neychev
C. Patel
S. Larach
Publikationsdatum
19.03.2020
Verlag
Springer International Publishing
Erschienen in
Techniques in Coloproctology / Ausgabe 5/2020
Print ISSN: 1123-6337
Elektronische ISSN: 1128-045X
DOI
https://doi.org/10.1007/s10151-020-02162-4

Weitere Artikel der Ausgabe 5/2020

Techniques in Coloproctology 5/2020 Zur Ausgabe

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.