Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 1/2014

01.02.2014 | Original Research

A technical description of a novel pharmacological anesthesia robot

verfasst von: Mohamad Wehbe, Erik Arbeid, Shantale Cyr, Pierre A. Mathieu, Riccardo Taddei, Joshua Morse, Thomas M. Hemmerling

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

To control the three components of general anesthesia (hypnosis, analgesia, and neuromuscular blockade), an automated closed-loop, anesthesia-drug delivery system (McSleepy) was developed. Bispectral index was used as the control variable for hypnosis, the analgoscore for analgesia, and phonomyography for neuromuscular blockade. McSleepy can be used to control the induction, maintenance and emergence from general anesthesia. To do so, a large touch screen is used to provide a user friendly interface, permitting bidirectional communication: the user giving information about the different stages of anesthesia, and the system prompting the anesthesiologist to perform certain actions such as mask ventilation, intubation or waking-up the patient using audio clips with voice commands. Several safety features were implemented to provide a secure and reliable anesthesia. Preliminary results of 15 patients are presented in this paper. Evaluation of McSleepy was done through an assessment of its clinical performance and using Varvel’s performance indices. The system was found to be clinically useful by providing good precision in drug administration and reliable results for the duration of a general anesthesia.
Literatur
1.
Zurück zum Zitat Miller RD, Eriksson LI, Fleisher LA, Wiener-Kronish JP, Young WL. Miller’s anesthesia, volume 1. Churchill Livingstone/Elsevier, 2009. Miller RD, Eriksson LI, Fleisher LA, Wiener-Kronish JP, Young WL. Miller’s anesthesia, volume 1. Churchill Livingstone/Elsevier, 2009.
2.
Zurück zum Zitat Morley A, Derrick J, Mainland P, Lee BB, Short TG. Closed loop control of anaesthesia: an assessment of the bispectral index as the target of control. Anaesthesia 2000; 55(10): 953–959.PubMedCrossRef Morley A, Derrick J, Mainland P, Lee BB, Short TG. Closed loop control of anaesthesia: an assessment of the bispectral index as the target of control. Anaesthesia 2000; 55(10): 953–959.PubMedCrossRef
3.
Zurück zum Zitat Struys MM, De Smet T, Versichelen LF, Van De Velde S, Van den Broecke R, Mortier EP Comparison of closed-loop controlled administration of propofol using bispectral index as the controlled variable versus “standard practice” controlled administration. Anesthesiology, 2001; 95(1): 6–17, ISSN 0003-3022. Struys MM, De Smet T, Versichelen LF, Van De Velde S, Van den Broecke R, Mortier EP Comparison of closed-loop controlled administration of propofol using bispectral index as the controlled variable versus “standard practice” controlled administration. Anesthesiology, 2001; 95(1): 6–17, ISSN 0003-3022.
4.
Zurück zum Zitat Eleveld DJ, Proost JH, Wierda JM. Evaluation of a closed-loop muscle relaxation control system. Anesth Analg, 2005; 101(3): 758–64, ISSN 0003-2999. Eleveld DJ, Proost JH, Wierda JM. Evaluation of a closed-loop muscle relaxation control system. Anesth Analg, 2005; 101(3): 758–64, ISSN 0003-2999.
5.
Zurück zum Zitat Gentilini A, Schaniel C, Morari M, Bieniok C, Wymann R, Schnider T. A new paradigm for the closed-loop intraoperative administration of analgesics in humans. Biomed Eng IEEE Trans, 2002; 49(4): 289–299, ISSN 0018-9294. Gentilini A, Schaniel C, Morari M, Bieniok C, Wymann R, Schnider T. A new paradigm for the closed-loop intraoperative administration of analgesics in humans. Biomed Eng IEEE Trans, 2002; 49(4): 289–299, ISSN 0018-9294.
6.
Zurück zum Zitat Hemmerling TM, Charabati S, Salhab E, Bracco D, Mathieu PA. The analgoscore: A novel score to monitor intraoperative nociception and its use for closed-loop application of remifentanil. J Comput, 2009; 4(4): 311–318. Hemmerling TM, Charabati S, Salhab E, Bracco D, Mathieu PA. The analgoscore: A novel score to monitor intraoperative nociception and its use for closed-loop application of remifentanil. J Comput, 2009; 4(4): 311–318.
7.
Zurück zum Zitat Locher S, Stadler KS, Boehlen T, Bouillon T, Leibundgut D, Schumacher PM, Wymann R, Zbinden AM. A new closed-loop control system for isoflurane using bispectral index outperforms manual control. Anesthesiology 2004; 101(3): 591–602.PubMedCrossRef Locher S, Stadler KS, Boehlen T, Bouillon T, Leibundgut D, Schumacher PM, Wymann R, Zbinden AM. A new closed-loop control system for isoflurane using bispectral index outperforms manual control. Anesthesiology 2004; 101(3): 591–602.PubMedCrossRef
8.
Zurück zum Zitat Kelly SD. Monitoring level of consciousness during anesthesia and sedation. Aspect Medical Systems, Inc., Newton, MA, 2003. Kelly SD. Monitoring level of consciousness during anesthesia and sedation. Aspect Medical Systems, Inc., Newton, MA, 2003.
9.
Zurück zum Zitat Viby-Mogensen J. Clinical assessment of neuromuscular transmission. Br J Anaesth 1982; 54(2): 209–223.PubMedCrossRef Viby-Mogensen J. Clinical assessment of neuromuscular transmission. Br J Anaesth 1982; 54(2): 209–223.PubMedCrossRef
10.
Zurück zum Zitat Hemmerling TM, Arbeid E, Tang L, Cyr S, Wehbe M, Giunta F, Zaouter C. Transcontinental anesthesia. Anesth Analg, 2011:A36. Hemmerling TM, Arbeid E, Tang L, Cyr S, Wehbe M, Giunta F, Zaouter C. Transcontinental anesthesia. Anesth Analg, 2011:A36.
11.
Zurück zum Zitat Hemmerling TM, Charabati S. Mcsleepy – a completely automatic anesthesia delivery system. Anesthesiology, 2009:A460. Hemmerling TM, Charabati S. Mcsleepy – a completely automatic anesthesia delivery system. Anesthesiology, 2009:A460.
12.
Zurück zum Zitat Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Pharmacodyn 1992; 20(1): 63–94.CrossRef Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Pharmacodyn 1992; 20(1): 63–94.CrossRef
13.
Zurück zum Zitat Puri GD, Kumar B, Aveek J Closed-loop anaesthesia delivery system (clads) using bispectral index: a performance assessment study. Anaesth Intensive Care 2007; 35(3): 357 – 362.PubMed Puri GD, Kumar B, Aveek J Closed-loop anaesthesia delivery system (clads) using bispectral index: a performance assessment study. Anaesth Intensive Care 2007; 35(3): 357 – 362.PubMed
14.
Zurück zum Zitat Sethu MJ, Puri GD, Mathew PJ. Closed-loop isoflurane administration with bispectral index in open heart surgery: Randomized controlled trial with manual control. Acta Anaesthesiol Taiwan, 2011; 49(4): 130–135.CrossRef Sethu MJ, Puri GD, Mathew PJ. Closed-loop isoflurane administration with bispectral index in open heart surgery: Randomized controlled trial with manual control. Acta Anaesthesiol Taiwan, 2011; 49(4): 130–135.CrossRef
15.
Zurück zum Zitat Liu N, Chazot T, Hamada S, Landais A, Boichut N, Dussaussoy C, Trillat B, Beydon L, Samain E, Sessler DI, Fischler M. Closed-loop coadministration of propofol and remifentanil guided by bispectral index: A randomized multicenter study. Anesth Analg 2011; 112(3): 546–557.PubMedCrossRef Liu N, Chazot T, Hamada S, Landais A, Boichut N, Dussaussoy C, Trillat B, Beydon L, Samain E, Sessler DI, Fischler M. Closed-loop coadministration of propofol and remifentanil guided by bispectral index: A randomized multicenter study. Anesth Analg 2011; 112(3): 546–557.PubMedCrossRef
16.
Zurück zum Zitat Iselin-Chaves IA, Flaishon R, Sebel PS, Howell S, Gan TJ, Sigl J, Ginsberg B, Glass PS. The effect of the interaction of propofol and alfentanil on recall, loss of consciousness, and the bispectral index. Anesth Analg 1998; 87(4): 949–955.PubMed Iselin-Chaves IA, Flaishon R, Sebel PS, Howell S, Gan TJ, Sigl J, Ginsberg B, Glass PS. The effect of the interaction of propofol and alfentanil on recall, loss of consciousness, and the bispectral index. Anesth Analg 1998; 87(4): 949–955.PubMed
17.
Zurück zum Zitat Guignard B, Menigaux C, Dupont X, Fletcher D, Chauvin M. The effect of remifentanil on the bispectral index change and hemodynamic responses after orotracheal intubation. Anesth Analg 2000; 90(1): 161.PubMedCrossRef Guignard B, Menigaux C, Dupont X, Fletcher D, Chauvin M. The effect of remifentanil on the bispectral index change and hemodynamic responses after orotracheal intubation. Anesth Analg 2000; 90(1): 161.PubMedCrossRef
18.
Zurück zum Zitat Liu N, Chazot T, Trillat B, Michel-Cherqui M, Marandon JY, Law-Koune JD, Rives B, Fischler M. Closed-loop control of consciousness during lung transplantation: an observational study. J Cardiothorac Vasc Anesth 2008; 22(4): 611–615.PubMedCrossRef Liu N, Chazot T, Trillat B, Michel-Cherqui M, Marandon JY, Law-Koune JD, Rives B, Fischler M. Closed-loop control of consciousness during lung transplantation: an observational study. J Cardiothorac Vasc Anesth 2008; 22(4): 611–615.PubMedCrossRef
19.
Zurück zum Zitat Carregal A, Lorenzo A, Taboada JA, Barreiro JL. Intraoperative control of mean arterial pressure and heart rate with alfentanyl with fuzzy logic. Rev Esp Anestesiol Reanim 2000; 47(3): 108.PubMed Carregal A, Lorenzo A, Taboada JA, Barreiro JL. Intraoperative control of mean arterial pressure and heart rate with alfentanyl with fuzzy logic. Rev Esp Anestesiol Reanim 2000; 47(3): 108.PubMed
Metadaten
Titel
A technical description of a novel pharmacological anesthesia robot
verfasst von
Mohamad Wehbe
Erik Arbeid
Shantale Cyr
Pierre A. Mathieu
Riccardo Taddei
Joshua Morse
Thomas M. Hemmerling
Publikationsdatum
01.02.2014
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 1/2014
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-013-9451-8

Weitere Artikel der Ausgabe 1/2014

Journal of Clinical Monitoring and Computing 1/2014 Zur Ausgabe

Mit dem Seitenschneider gegen das Reißverschluss-Malheur

03.06.2024 Urologische Notfallmedizin Nachrichten

Wer ihn je erlebt hat, wird ihn nicht vergessen: den Schmerz, den die beim Öffnen oder Schließen des Reißverschlusses am Hosenschlitz eingeklemmte Haut am Penis oder Skrotum verursacht. Eine neue Methode für rasche Abhilfe hat ein US-Team getestet.

Schlaganfall: frühzeitige Blutdrucksenkung im Krankenwagen ohne Nutzen

31.05.2024 Apoplex Nachrichten

Der optimale Ansatz für die Blutdruckkontrolle bei Patientinnen und Patienten mit akutem Schlaganfall ist noch nicht gefunden. Ob sich eine frühzeitige Therapie der Hypertonie noch während des Transports in die Klinik lohnt, hat jetzt eine Studie aus China untersucht.

Reanimation bei Kindern – besser vor Ort oder während Transport?

29.05.2024 Reanimation im Kindesalter Nachrichten

Zwar scheint es laut einer Studie aus den USA und Kanada bei der Reanimation von Kindern außerhalb einer Klinik keinen Unterschied für das Überleben zu machen, ob die Wiederbelebungsmaßnahmen während des Transports in die Klinik stattfinden oder vor Ort ausgeführt werden. Jedoch gibt es dabei einige Einschränkungen und eine wichtige Ausnahme.

Nicht Creutzfeldt Jakob, sondern Abführtee-Vergiftung

29.05.2024 Hyponatriämie Nachrichten

Eine ältere Frau trinkt regelmäßig Sennesblättertee gegen ihre Verstopfung. Der scheint plötzlich gut zu wirken. Auf Durchfall und Erbrechen folgt allerdings eine Hyponatriämie. Nach deren Korrektur kommt es plötzlich zu progredienten Kognitions- und Verhaltensstörungen.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.