Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an Emergency Department for drug or alcoholic poisoning

verfasst von: Youcef Guechi, Amélie Pichot, Denis Frasca, Fatima Rayeh-Pelardy, Jean-Yves Lardeur, Olivier Mimoz

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 6/2015

Einloggen, um Zugang zu erhalten

Abstract

To compare respiration rate measurement by an acoustic method and thoracic impedance to capnometry as the reference method, in patients at the Emergency Department after drug or alcoholic poisoning. In this observational study, 30 patients aged 18 or older, hospitalized at the Emergency Department for drug or alcoholic poisoning, without any contraindication to a face mask and/or a cervical acoustic sensor, were included in the study. They benefited from a simultaneous recording of their respiration rate by the acoustic method (RRa®, Masimo Corp., Irvine, CA, USA), by thoracic impedance (Philips Intellivue® MP2, Suresnes, France) and by capnometry (Capnostream® 20, Oridion, Jerusalem, Israël) through a face mask (Capnomask®, Mediplus Ltd, Raleigh, NC, USA) for 40–60 min. Of the 86,578 triplets collected, 77,155 (89.1 %) were exploitable. Median (range) respiration rate measured by capnometry was 18 (7–29) bpm. Compared to capnometry, bias and limits of agreement were 0.1 ± 3.8 bpm for the acoustic method and 0.3 ± 5.5 bpm for thoracic impedance. The proportions of RR values collected by acoustic method or by thoracic impedance which differed over 10 or 20 % during more than 15 s, compared to capnometry, were 8.3 versus 14.3, and 1.5 versus 3.8 %, respectively (p < 0.0001). The acoustic sensor had to be repositioned on three patients. For 11 patients, the Capnomask® was removed several times. In patients with drug or alcoholic poisoning, the acoustic method seems more accurate than thoracic impedance and better tolerated than face mask capnometry.
Literatur
1.
Zurück zum Zitat Pouyanne P, Haramburu F, Imbs JL, et al. Admissions to hospital caused by adverse drug reactions: cross sectional incidence study. BMJ. 2000;320:1036.PubMedCentralCrossRefPubMed Pouyanne P, Haramburu F, Imbs JL, et al. Admissions to hospital caused by adverse drug reactions: cross sectional incidence study. BMJ. 2000;320:1036.PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Bordet R, Gautier S, Le Louet H, et al. Analysis of the direct cost of adverse drug reactions in hospitalised patients. Eur J Clin Pharmacol. 2001;56:935–41.CrossRefPubMed Bordet R, Gautier S, Le Louet H, et al. Analysis of the direct cost of adverse drug reactions in hospitalised patients. Eur J Clin Pharmacol. 2001;56:935–41.CrossRefPubMed
3.
Zurück zum Zitat Folke M, Cernerud L, Ekström M, et al. Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput. 2003;41:377–83.CrossRefPubMed Folke M, Cernerud L, Ekström M, et al. Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput. 2003;41:377–83.CrossRefPubMed
4.
Zurück zum Zitat Keidan I, Gravenstein D, Berkenstadt H, et al. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008;122:293–8.CrossRefPubMed Keidan I, Gravenstein D, Berkenstadt H, et al. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008;122:293–8.CrossRefPubMed
5.
Zurück zum Zitat Fu ES, Downs JB, Schweiger JW, et al. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126:1552–8.CrossRefPubMed Fu ES, Downs JB, Schweiger JW, et al. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126:1552–8.CrossRefPubMed
6.
Zurück zum Zitat Petterson MT, Begnoche VL, Graybeal JM. The effect of motion on pulse oximetry and its clinical significance. Anesth Analg. 2007;105:S78–84.CrossRefPubMed Petterson MT, Begnoche VL, Graybeal JM. The effect of motion on pulse oximetry and its clinical significance. Anesth Analg. 2007;105:S78–84.CrossRefPubMed
7.
Zurück zum Zitat Wilkinson JN, Thanawala VU. Thoracic impedance monitoring of respiratory rate during sedation—Is it safe? Anaesthesia. 2009;64:455–6.CrossRefPubMed Wilkinson JN, Thanawala VU. Thoracic impedance monitoring of respiratory rate during sedation—Is it safe? Anaesthesia. 2009;64:455–6.CrossRefPubMed
8.
Zurück zum Zitat Cohen KP, Ladd WM, Beams DM, et al. Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction. IEEE Trans Biomed Eng. 1997;44:555–66.CrossRefPubMed Cohen KP, Ladd WM, Beams DM, et al. Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction. IEEE Trans Biomed Eng. 1997;44:555–66.CrossRefPubMed
9.
Zurück zum Zitat Drummond GB, Nimmo AF, Elton RA. Thoracic impedance used for measuring chest wall movement in postoperative patients. Br J Anaesth. 1996;77:327–32.CrossRefPubMed Drummond GB, Nimmo AF, Elton RA. Thoracic impedance used for measuring chest wall movement in postoperative patients. Br J Anaesth. 1996;77:327–32.CrossRefPubMed
10.
Zurück zum Zitat Brouillette RT, Morrow AS, Weese-Mayer DE, et al. Comparison of respiratory inductive plethysmography and thoracic impedance for apnea monitoring. J Pediatr. 1987;111:377–83.CrossRefPubMed Brouillette RT, Morrow AS, Weese-Mayer DE, et al. Comparison of respiratory inductive plethysmography and thoracic impedance for apnea monitoring. J Pediatr. 1987;111:377–83.CrossRefPubMed
11.
Zurück zum Zitat Mimoz O, Benard T, Gaucher A, et al. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia. Br J Anaesth. 2012;108:872–5.CrossRefPubMed Mimoz O, Benard T, Gaucher A, et al. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia. Br J Anaesth. 2012;108:872–5.CrossRefPubMed
12.
Zurück zum Zitat Ramsay MAE, Usman M, Lagow E, et al. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013;117:69–75.CrossRefPubMed Ramsay MAE, Usman M, Lagow E, et al. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013;117:69–75.CrossRefPubMed
13.
Zurück zum Zitat Autet L, Frasca D, Pinsard M, et al. Evaluation of acoustic respiration rate monitoring following extubation in ICU patients. Br J Anaesth. 2014;113:195–7.CrossRefPubMed Autet L, Frasca D, Pinsard M, et al. Evaluation of acoustic respiration rate monitoring following extubation in ICU patients. Br J Anaesth. 2014;113:195–7.CrossRefPubMed
14.
Zurück zum Zitat Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed
15.
Zurück zum Zitat Critchley LA, Lee A, Ho AM-H. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180–92.CrossRefPubMed Critchley LA, Lee A, Ho AM-H. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180–92.CrossRefPubMed
16.
Zurück zum Zitat Gaucher A, Frasca D, Mimoz O, et al. Accuracy of respiratory rate monitoring by capnometry using the Capnomask® in extubated patients receiving supplemental oxygen after surgery. Br J Anaesth. 2012;108:316–20.CrossRefPubMed Gaucher A, Frasca D, Mimoz O, et al. Accuracy of respiratory rate monitoring by capnometry using the Capnomask® in extubated patients receiving supplemental oxygen after surgery. Br J Anaesth. 2012;108:316–20.CrossRefPubMed
17.
Zurück zum Zitat Sesay M, Tauzin-Fin P, Verdonck O, et al. Clinical evaluation of the Capnomask in the supine vs. prone position during monitored anaesthesia care. Eur J Anaesthesiol. 2008;25:769–71.CrossRefPubMed Sesay M, Tauzin-Fin P, Verdonck O, et al. Clinical evaluation of the Capnomask in the supine vs. prone position during monitored anaesthesia care. Eur J Anaesthesiol. 2008;25:769–71.CrossRefPubMed
18.
Zurück zum Zitat Maddox RR, Williams CK, Oglesby H, et al. Clinical experience with patient-controlled analgesia using continuous respiratory monitoring and a smart infusion system. Am J Health Syst Pharm. 2006;63:157–64.CrossRefPubMed Maddox RR, Williams CK, Oglesby H, et al. Clinical experience with patient-controlled analgesia using continuous respiratory monitoring and a smart infusion system. Am J Health Syst Pharm. 2006;63:157–64.CrossRefPubMed
19.
Zurück zum Zitat Friesen RH, Alswang M. End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error. J Clin Monit. 1996;12:155–9.CrossRefPubMed Friesen RH, Alswang M. End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: accuracy and sources of error. J Clin Monit. 1996;12:155–9.CrossRefPubMed
20.
Zurück zum Zitat Goudra B, Penugonda L, Speck R, et al. Comparison of acoustic respiration rate, impedance pneumography and capnometry monitors for respiration rate accuracy and apnea detection during GI endoscopy anesthesia. Open J Anesthesiol. 2013;3:74–9.CrossRef Goudra B, Penugonda L, Speck R, et al. Comparison of acoustic respiration rate, impedance pneumography and capnometry monitors for respiration rate accuracy and apnea detection during GI endoscopy anesthesia. Open J Anesthesiol. 2013;3:74–9.CrossRef
21.
Zurück zum Zitat Voscopoulos CJ, MacNabb CM, Freeman J, et al. Continuous noninvasive respiratory volume monitoring for the identification of patients at risk for opioid-induced respiratory depression and obstructive breathing patterns. J Trauma Acute Care Surg. 2014;77:S208–15.CrossRefPubMed Voscopoulos CJ, MacNabb CM, Freeman J, et al. Continuous noninvasive respiratory volume monitoring for the identification of patients at risk for opioid-induced respiratory depression and obstructive breathing patterns. J Trauma Acute Care Surg. 2014;77:S208–15.CrossRefPubMed
22.
Zurück zum Zitat Voscopoulos CJ, MacNabb CM, Brayanov J, et al. The evaluation of a non-invasive respiratory volume monitor in surgical patients undergoing elective surgery with general anesthesia. J Clin Monit Comput. 2014. doi:10.1007/s10877-014-9596-0. Voscopoulos CJ, MacNabb CM, Brayanov J, et al. The evaluation of a non-invasive respiratory volume monitor in surgical patients undergoing elective surgery with general anesthesia. J Clin Monit Comput. 2014. doi:10.​1007/​s10877-014-9596-0.
Metadaten
Titel
Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an Emergency Department for drug or alcoholic poisoning
verfasst von
Youcef Guechi
Amélie Pichot
Denis Frasca
Fatima Rayeh-Pelardy
Jean-Yves Lardeur
Olivier Mimoz
Publikationsdatum
01.12.2015
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2015
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9658-y

Weitere Artikel der Ausgabe 6/2015

Journal of Clinical Monitoring and Computing 6/2015 Zur Ausgabe

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.