Abstract

One of the primary goals of anaesthesia in neurosurgical procedures is prevention of cerebral hypoxia leading to secondary neurological injury. Cerebral oximetry detects periods of cerebral hypoxemia and allows intervention for prevention of secondary brain injury and its sequelae. This can be achieved by the use of Near Infrared Spectroscopy (NIRS). In this regard, we present two cases where erroneous values of NIRS were shown which hindered monitoring of cerebral oxygenation in the intraoperative setting. In a neurosurgical setting, the erroneous values on the operative side could be attributed to altered tissue boundary conditions resulting in a changed optical path, which is normally held as a constant in NIRS measurements. The altered tissue boundary conditions could be due to the presence of air or blood between the myocutaneous flapskull, skull-dura, dura-brain interphases. It could also be that the sensors’ penetrating depth was inadequate to compensate for the increased distance between sensor and brain tissue, thereby resulting in inaccurately higher values (> 80%).
Literatur
1.
Zurück zum Zitat Murkin JM, Arango M. Near-infrared spectroscopy as an index of brain and tissue oxygenation. Br J Anaesth. 2009;103(1):i3–13.CrossRefPubMed Murkin JM, Arango M. Near-infrared spectroscopy as an index of brain and tissue oxygenation. Br J Anaesth. 2009;103(1):i3–13.CrossRefPubMed
2.
Zurück zum Zitat Kurth CD, Uher BS. Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation. Anesth Analg. 1997;84:1297–305.CrossRefPubMed Kurth CD, Uher BS. Cerebral hemoglobin and optical pathlength influence near-infrared spectroscopy measurement of cerebral oxygen saturation. Anesth Analg. 1997;84:1297–305.CrossRefPubMed
3.
Zurück zum Zitat Yoshitani K, Kawaguchi M, Miura N, et al. Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements. Anesthesiology. 2007;106:458–62.CrossRefPubMed Yoshitani K, Kawaguchi M, Miura N, et al. Effects of hemoglobin concentration, skull thickness, and the area of the cerebrospinal fluid layer on near-infrared spectroscopy measurements. Anesthesiology. 2007;106:458–62.CrossRefPubMed
4.
Zurück zum Zitat Tobias JD. Cerebral oxygenation monitoring: near-infrared spectroscopy. Expert Rev Med Devices. 2006;3(2):235–43.CrossRefPubMed Tobias JD. Cerebral oxygenation monitoring: near-infrared spectroscopy. Expert Rev Med Devices. 2006;3(2):235–43.CrossRefPubMed
5.
Zurück zum Zitat Young AE, Germon TJ, Barnett NJ, Manara AR, Nelson RJ. Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy. Br J Anaesth. 2000;84:38–42.CrossRefPubMed Young AE, Germon TJ, Barnett NJ, Manara AR, Nelson RJ. Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy. Br J Anaesth. 2000;84:38–42.CrossRefPubMed
6.
Zurück zum Zitat Kim W, Taw B, Yokosako S, et al. The future of non-invasive cerebral oximetry in neurosurgical procedures: a systematic review. MNI Open Res. 2018;2:3.CrossRef Kim W, Taw B, Yokosako S, et al. The future of non-invasive cerebral oximetry in neurosurgical procedures: a systematic review. MNI Open Res. 2018;2:3.CrossRef
7.
Zurück zum Zitat Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012;26:279–87.CrossRefPubMedPubMedCentral Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012;26:279–87.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Scheeren TW, Saugel B. Journal of clinical monitoring and computing 2016 end of year summary: monitoring cerebral oxygenation and autoregulation. J Clin Monit Comput. 2017;31:241–6.CrossRefPubMedPubMedCentral Scheeren TW, Saugel B. Journal of clinical monitoring and computing 2016 end of year summary: monitoring cerebral oxygenation and autoregulation. J Clin Monit Comput. 2017;31:241–6.CrossRefPubMedPubMedCentral
Metadaten
Titel
Limitations of near infrared spectroscopy (NIRS) in neurosurgical setting: our case experience
verfasst von
Neeraja Ajayan
Keta Thakkar
Karen Ruby Lionel
Ajay Prasad Hrishi
Publikationsdatum
12.10.2018
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2019
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0209-1

Weitere Artikel der Ausgabe 4/2019

Journal of Clinical Monitoring and Computing 4/2019 Zur Ausgabe

Bei schweren Reaktionen auf Insektenstiche empfiehlt sich eine spezifische Immuntherapie

Insektenstiche sind bei Erwachsenen die häufigsten Auslöser einer Anaphylaxie. Einen wirksamen Schutz vor schweren anaphylaktischen Reaktionen bietet die allergenspezifische Immuntherapie. Jedoch kommt sie noch viel zu selten zum Einsatz.

Hinter dieser Appendizitis steckte ein Erreger

23.04.2024 Appendizitis Nachrichten

Schmerzen im Unterbauch, aber sonst nicht viel, was auf eine Appendizitis hindeutete: Ein junger Mann hatte Glück, dass trotzdem eine Laparoskopie mit Appendektomie durchgeführt und der Wurmfortsatz histologisch untersucht wurde.

Ärztliche Empathie hilft gegen Rückenschmerzen

23.04.2024 Leitsymptom Rückenschmerzen Nachrichten

Personen mit chronischen Rückenschmerzen, die von einfühlsamen Ärzten und Ärztinnen betreut werden, berichten über weniger Beschwerden und eine bessere Lebensqualität.

Mehr Schaden als Nutzen durch präoperatives Aussetzen von GLP-1-Agonisten?

23.04.2024 Operationsvorbereitung Nachrichten

Derzeit wird empfohlen, eine Therapie mit GLP-1-Rezeptoragonisten präoperativ zu unterbrechen. Eine neue Studie nährt jedoch Zweifel an der Notwendigkeit der Maßnahme.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.